HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LICAUSI RESIDENCE LOT 4
Builder Name:
Street: 4905 RIVER PLACE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner. STEVE AND MARILYN LICAUSI
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1968.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1832.50 ft2
b. Frame - Wood, Adjacent
R=11.0 136.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1644.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1644.00 ft2
6. Conditioned floor area above grade (ft2) 1644
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows (202.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Garage
6 140
a. U-Factor: Sgl, U=0.34 139.00 ft2
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.33 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.16
a. Central Unit
30.0 SEER:16.00
c. U-Factor: Sgl, U=0.28 23.00 ft2
SHGC: SHGC=0.18
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
27.0 COPA.00
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.204
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (1644.0 sqft.) Insulation Area
EF: 0.990
a. Slab -On -Grade Edge Insulation R=0.0 1644.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None
Glass/Floor Area: 0.123 Total Proposed Modified Loads: 53.66
P p c c
Total Baseline Loads: 61.68
R-%%a 7
I hereby certify that the plans and specifications covered by
Review of the plans and
&IIHE ST,q?'
this calculation are in compliance with the Florida Energy
specifications covered by this
- 0 g ; FO
Code
calculation indicates compliance
M .{l,
`,.-'��.��
�'
with the Florida Energy Code.
PREPARED Y:
Before construction is completed
DATE:0$4*
this building will be inspected for
compliance with Section 553.908
hereby certify that this buil i as des' n , is in compliance
Florida Statutes.
with the Florida Energy C Co
WE
OWNE�A N
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
File cony
11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2014
PROJECT
Title:
LICAUSI RESIDENCE LOT 4
Bedrooms:
3
Address Type:
Street Address
Building Type:
User
Conditioned Area:
1644
Lot #
Owner:
STEVE AND MARILYN LICAU
Total Stories:
1
Block/SubDivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
Rotate Angle:
0
Street:
4905 RIVER PLACE
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
Zone
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
1644
16440
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1
M BATH
84
840 No
0
1
Yes
Yes
Yes
2
M TOILET
36
360 No
0
1
Yes
Yes
Yes
3
MASTER BEDROO
228
2280 No
0
1
1
Yes
Yes
Yes
4
M WIC 1
60
600 No
0
1
Yes
Yes
Yes
5
M WIC 2
28
280 No
0
1
No
Yes
Yes
6
STORAGE
28
280 No
0
1
Yes
Yes
Yes
7
UTILITY
66
660 No
0
1
Yes
Yes
Yes
8
LAUNDRY
48
480 No
0
1
Yes
Yes
Yes
9
FOYER
70
700 No
0
1
Yes
Yes
Yes
10
BEDROOM 3
166
1660 No
0
1
1
Yes
Yes
Yes
11
KITCHEN
165
1650 No
0
1
No
Yes
Yes
12
CAFE
130
1300 No
0
1
Yes
Yes
Yes
13
FAMILY ROOM
267
2670 No
0
1
Yes
Yes
Yes
14
HALL
32
320 No
0
1
Yes
Yes
Yes
15
BATH 2
56
560 No
0
1
Yes
Yes
Yes
16
CLST 2
16
160 No
0
1
Yes
Yes
Yes
17
BEDROOM 2
164
1640 No
0
1
1
Yes
Yes
Yes
11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
M BATH
19 ft
0
84 ft2
___-
1
0
0
2 Slab -On -Grade Edge Insulation
M TOILET
4 ft
0
36 ft2
1
0
0
3 Slab -On -Grade Edge Insulation
MASTER BEDRO 14 ft
0
228 ft2
____
1
0
0
4 Slab -On -Grade Edge Insulation
M W IC 1
loft
0
60 ft2
____
1
0
0
5 Slab -On -Grade Edge Insulation
M W IC 2
1 ft
0
28 ft2
-___
1
0
0
6 Slab -On -Grade Edge Insulation
STORAGE
4ft
0
28 ft2
1
0
0
7 Slab -On -Grade Edge Insulation
UTILITY
6 ft
0
66 ft2
____
1
0
0
8 Slab -On -Grade Edge Insulation
LAUNDRY
lift
0
48 ft2
1
0
0
9 Slab -On -Grade Edge Insulation
FOYER
5 ft
0
70 ft2
1
0
0
10SIab-On-Grade Edge Insulation
BEDROOM 3
17 ft
0
166 ft2
____
1
0
0
11Slab-On-Grade Edge Insulation
KITCHEN
1 ft
0
165 ft2
__-_
1 .
0
0
12SIab-On-Grade Edge Insulation
CAFE
20 ft
0
130 ft2
____
1
0
0
13SIab-On-Grade Edge Insulation
FAMILY ROOM 26.2 ft
0
267 ft2
__e
1
0
0
14SIab-On-Grade Edge Insulation
HALL
4ft
0
32 1112
__e
1
0
0
15SIab-On-Grade Edge Insulation
BATH 2
16 ft
0
56 ft2
____
1
0
0
16SIab-On-Grade Edge Insulation
CLST 2
2 ft
0
16 ft2
____
1
0
0
17SIab-On-Grade Edge Insulation
BEDROOM 2
25 ft
0
164 ft2
1
0
0
ROOF
v
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
# Type Materials
Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip Metal 1839 ft2
0 ft2
Light
0.6
No 0.9
No
20
26.6
ATTIC
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Unvented
0
1644 ft2
N N
11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2014
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) M BATH
20
Blown
84 ft2
0.1
Wood
2
Under Attic (Unvented) M TOILET
20
Blown
36 ft2
0.1
Wood
3
Under Attic (Unvented) MASTER BEDRO
20
Blown
228 ft2
0.1
Wood
4
Under Attic (Unvented) M WIC 1
20
Blown
60ft2
0.1
Wood
5
Under Attic (Unvented) M WIC 2
20
Blown
28 ft2
0.1
Wood
6
Under Attic (Unvented) STORAGE
20
Blown
28ft2
0.1
Wood
7
Under Attic (Unvented) UTILITY
20
Blown
66 ft2
0.1
Wood
8
Under Attic (Unvented) LAUNDRY
20
Blown
48 ft2
0.1
Wood
9
Under Attic (Unvented) FOYER
20
Blown
70 ft2
0.1
Wood
10
Under Attic (Unvented) BEDROOM 3
20
Blown
166 ft2
0.1
Wood
11
Under Attic (Unvented) KITCHEN
20
Blown
165 ft2
0.1
Wood
12
Under Attic (U nvented) CAFE
20
Blown
130ft2
0.1
Wood
13
Under Attic (Unvented) FAMILY ROOM
20
Blown
267 ft2
0.1
Wood
14
Under Attic (U nvented) HALL
20
Blown
32ft2
0.1
Wood
15
Under Attic (Unvented) BATH 2
20
Blown
56 ft2
0.1
Wood
16
Under Attic (Unvented) CLST 2
20
Blown
16 ft2
0.1
Wood
17
Under Attic (Unvented) BEDROOM 2
20
Blown
164 ft2
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing Solar
Below
Space
1
N
Exterior Concrete Block - Ext Insul M BATH
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
2
W
Exterior Concrete Block - Ext Insul M BATH
4.1
7
0 10
0
70.0 ft2
0
0
0.6
0
3
N
Exterior Concrete Block - Ext InsulM TOILET
4.1
4
0 10
0
40.0 ft2
0
0
0.6
0
4
W
Exterior Concrete Block - Ext InsLW1ASTER BE
4.1
14
0 10
0
140.0 ft2
0
0
0.6
0
5
W
Exterior Concrete Block - Ext Insul M W IC 1
4.1
10
0 10
0
100.0 ft2
0
0
0.6
0
6
S
Exterior Concrete Block - Ext InsuISTORAGE
4.1
4
0 10
0
40.0 ft2
0
0
0.6
0
7
S
Exterior Concrete Block - Ext Insul UTILITY
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
8
S
Exterior Concrete Block - Ext InsuILAUNDRY
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
9
W
Exterior Concrete Block - Ext InsuILAUNDRY
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
10
S
Exterior Concrete Block - Ext Insul FOYER
4.1
5
0 10
0
50.0 ft2
0
0
0.6
0
11
S
Exterior Concrete Block - Ext InstBEDROOM 3
4.1
11
0 10
0
110.0 ft2
0
0
0.6
0
12
W
Exterior Concrete Block - Ext InstSEDROOM 3
4.1
6
0 10
0
60.0 ft2
0
0
0.6
0
13
N
Exterior Concrete Block - Ext Insul CAFE
4.1
10
0 10
0
100.0 ft2
0
0
0.6
0
14
E
Exterior Concrete Block- Ext Insul CAFE
4.1
10
0 10
0
100.0 ft2
0
0
0.6
0
15
N
Exterior Concrete Block - Ext InsdHAMILY ROO
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
16
NE
Exterior Concrete Block - Ext Ins81AMILY ROO
4.1
4
3 10
0
42.5 ft2
0
0
0.6
0
17
E
Exterior Concrete Block - Ext InsSAMILY ROO
4.1
10
0 10
0
100.0 ft2
0
0
0.6
0
18
N
Exterior Concrete Block- Ext Insul HALL
4.1
4
0 10
0
40.0 ft2
0
0
0.6
0
19
N
Exterior Concrete Block - Ext Insul BATH 2
4.1
8
0 10
0
80.0 ft2
0
0
0.6
0
20
E
Exterior Concrete Block - Ext Insul BATH 2
4.1
8
0 10
0
80.0 ft2
0
0
0.6
0
21
E
Exterior Concrete Block - Ext Insul CLST 2
4.1
2
0 10
0
20.0 ft2
0
0
0.6
0
_ 22
E
Exterior Concrete Block - Ext InstBEDROOM 2
4.1
13
0 10
0
130.0 ft2
0
0
0.6
0
23
S
Exterior Concrete Block - Ext InsMEDROOM 2
4.1
12
0 10
0
120.0 ft2
0
0
0.6
0
11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2014
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
24 N
Garage Frame - Wood
M W IC 1
11 8 8
64.0 ft2
0
0 0.600000 0
_ 25 W
Garage Frame - Wood
M W IC 1
11 3 8
24.0 ft2
0
0 0.600000 0
_ 26 E
Garage Frame - Wood
STORAGE 11 6 8
48.0 ft2
0
0 0.600000 0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Insulated
FOYER
None
.39
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
V
Wall
Overhang
#
Omt ID Frame
Panes
NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
N 1 Metal
Low-E Single
Yes
0.34 0.22
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
2
W 4 Metal
Low-E Single
Yes
0.34 0.22
8.0 ft2
1 ft 0 in
1 ft 4 in
None
None
3
S 8 Metal
Low-E Single
Yes
0.34 0.22
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
4
S 10 Metal
Low-E Single
Yes
0.34 0.22
3.0 ft2
1 ft 0 in
1 ft 4 in
None
None
5
S 11 Metal
Low-E Single
Yes
0.34 0.22
8.0 ft2
1 ft 0 in
1 ft 4 in
None
None
6
N 13 Metal
Low-E Single
Yes
0.34 0.22
12.0 ft2
1 ft 0 in
1 ft 4 in
None
None
7
E 14 Metal
Low-E Single
Yes
0.28 0.18
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
8
N 15 Metal
Low-E Single
Yes
0.34 0.22
45.0 ft2
1 ft 0 in
1 ft 4 in
None
None
9
NE 16 Metal
Low-E Single
Yes
0.33 0.16
20.0 ft2
1 ft 0 in
1 ft 4 in
None
None
10
E 17 Metal
Low-E Single
Yes
0.34 0.22
45.0 ft2
1 ft 0 in
1 ft 4 in
None
None
11
N 18 Metal
Low-E Single
Yes
0.33 0.16
20.0 ft2
1 ft 0 in
1 ft 4 in
None
None
12
E 20 Metal
Low-E Single
Yes
0.34 0.22
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
13
S 23 Metal
Low-E Single
Yes
0.28 0.18
8.0 ft2
1 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
576 ft2
384 ft2
17 ft
8 ft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000445
1918 105.3 198.02
.3247
7
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat
None
COP:1
27 kBtu/hr
1
sys#1
11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2014
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit
Split
SEER: 16
30 kBtu/hr
900 cfm
0.8
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
Tankless
Garage
0.99 1 gal
55.1 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model # Area
Volume
FEF
None None
ft2
DUCTS
— Supply —
V
— Return —
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 140 ft2
Attic
14 ft2 Default Leakage
Garage
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
CoolingJan Feb
HeatinJan Feb
Mar
Mar
Apr
Apr
Me Jun Jul
May Jun Jul
Au
4 AuSep
Se
f
Oct
Oct
[ ] Nov
[X] Nov
[ ] Dec
[X] Dec
Vent in Jan Feb
Mar
Apr
[ May Jun Jul
l
[ Aug
Se [Xj
Oct
[X] Nov
[ ]Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8 9
10
11
12
Cooling (W D) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 80
80 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78 80
80
80
80
PM
80
80 80
80 78 78
78
78 78
78
78
78
Heating (WD) AM
65
65 65
65 65 65
65
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
68
68
Heating (WEH) AM
65
65 65
65 65 65
65
68 68
68
68
68
PM
68
68 68
68 68 68
68
68 68
68
68
68
11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: LICAUSI RESIDENCE LOT 4 Builder Name:
Street: 4905 RIVER PLACE Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: STEVE AND MARILYN LICAUSI Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
11/16/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 87
The lower the EnergyPerformance Index, the more efficient the home.
i
4905 RIVER PLACE, FORT PIERCE, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext Insul, Exterior
R=4.1
1832.50 ft2
b. Frame - Wood, Adjacent
R=11.0
136.00 ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
3 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No a. Roof Deck (Unvented)
R=20.0
1644.00 ftZ
6. Conditioned floor area (ftZ)
1644 b. N/A
R=
ft2
7. Windows" Description
Area c. N/A
R=
ft2
a. U-Factor: Sgl, U=0.34
139.00 ft2 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ft2
6 140
SHGC: SHGC=0.22
b. U-Factor: Sgl, U=0.33
40.00 ft2
SHGC: SHGC=0.16
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Sgl, U=0.28
23.00 ft2 a. Central Unit
30.0 SEER:16.00
SHGC: SHGC=0.18
d. U-Factor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Strip Heat
27.0
COP:1.00
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.204
8. Floor Types Insulation Area 14. Hot water systems
Cap:
1 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1644.00 ft2 a. Electric
EF: 0.99
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
None
15. Credits
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building.
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final in�pe tion. Otherwis , a new EPL Display Card will be completed
based on installed Code co iant fea es GAL
s
Builder Signature: Date: ZZ
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/16/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1