Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LICAUSI RESIDENCE LOT 4 Builder Name: Street: 4905 RIVER PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner. STEVE AND MARILYN LICAUSI Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1968.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1832.50 ft2 b. Frame - Wood, Adjacent R=11.0 136.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (1644.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1644.00 ft2 6. Conditioned floor area above grade (ft2) 1644 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows (202.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Garage 6 140 a. U-Factor: Sgl, U=0.34 139.00 ft2 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.33 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.16 a. Central Unit 30.0 SEER:16.00 c. U-Factor: Sgl, U=0.28 23.00 ft2 SHGC: SHGC=0.18 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.204 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1644.0 sqft.) Insulation Area EF: 0.990 a. Slab -On -Grade Edge Insulation R=0.0 1644.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.123 Total Proposed Modified Loads: 53.66 P p c c Total Baseline Loads: 61.68 R-%%a 7 I hereby certify that the plans and specifications covered by Review of the plans and &IIHE ST,q?' this calculation are in compliance with the Florida Energy specifications covered by this - 0 g ; FO Code calculation indicates compliance M .{l, `,.-'��.�� �' with the Florida Energy Code. PREPARED Y: Before construction is completed DATE:0$4* this building will be inspected for compliance with Section 553.908 hereby certify that this buil i as des' n , is in compliance Florida Statutes. with the Florida Energy C Co WE OWNE�A N BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). File cony 11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: LICAUSI RESIDENCE LOT 4 Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1644 Lot # Owner: STEVE AND MARILYN LICAU Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4905 RIVER PLACE Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1644 16440 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 M BATH 84 840 No 0 1 Yes Yes Yes 2 M TOILET 36 360 No 0 1 Yes Yes Yes 3 MASTER BEDROO 228 2280 No 0 1 1 Yes Yes Yes 4 M WIC 1 60 600 No 0 1 Yes Yes Yes 5 M WIC 2 28 280 No 0 1 No Yes Yes 6 STORAGE 28 280 No 0 1 Yes Yes Yes 7 UTILITY 66 660 No 0 1 Yes Yes Yes 8 LAUNDRY 48 480 No 0 1 Yes Yes Yes 9 FOYER 70 700 No 0 1 Yes Yes Yes 10 BEDROOM 3 166 1660 No 0 1 1 Yes Yes Yes 11 KITCHEN 165 1650 No 0 1 No Yes Yes 12 CAFE 130 1300 No 0 1 Yes Yes Yes 13 FAMILY ROOM 267 2670 No 0 1 Yes Yes Yes 14 HALL 32 320 No 0 1 Yes Yes Yes 15 BATH 2 56 560 No 0 1 Yes Yes Yes 16 CLST 2 16 160 No 0 1 Yes Yes Yes 17 BEDROOM 2 164 1640 No 0 1 1 Yes Yes Yes 11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation M BATH 19 ft 0 84 ft2 ___- 1 0 0 2 Slab -On -Grade Edge Insulation M TOILET 4 ft 0 36 ft2 1 0 0 3 Slab -On -Grade Edge Insulation MASTER BEDRO 14 ft 0 228 ft2 ____ 1 0 0 4 Slab -On -Grade Edge Insulation M W IC 1 loft 0 60 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation M W IC 2 1 ft 0 28 ft2 -___ 1 0 0 6 Slab -On -Grade Edge Insulation STORAGE 4ft 0 28 ft2 1 0 0 7 Slab -On -Grade Edge Insulation UTILITY 6 ft 0 66 ft2 ____ 1 0 0 8 Slab -On -Grade Edge Insulation LAUNDRY lift 0 48 ft2 1 0 0 9 Slab -On -Grade Edge Insulation FOYER 5 ft 0 70 ft2 1 0 0 10SIab-On-Grade Edge Insulation BEDROOM 3 17 ft 0 166 ft2 ____ 1 0 0 11Slab-On-Grade Edge Insulation KITCHEN 1 ft 0 165 ft2 __-_ 1 . 0 0 12SIab-On-Grade Edge Insulation CAFE 20 ft 0 130 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation FAMILY ROOM 26.2 ft 0 267 ft2 __e 1 0 0 14SIab-On-Grade Edge Insulation HALL 4ft 0 32 1112 __e 1 0 0 15SIab-On-Grade Edge Insulation BATH 2 16 ft 0 56 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation CLST 2 2 ft 0 16 ft2 ____ 1 0 0 17SIab-On-Grade Edge Insulation BEDROOM 2 25 ft 0 164 ft2 1 0 0 ROOF v Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1839 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1644 ft2 N N 11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) M BATH 20 Blown 84 ft2 0.1 Wood 2 Under Attic (Unvented) M TOILET 20 Blown 36 ft2 0.1 Wood 3 Under Attic (Unvented) MASTER BEDRO 20 Blown 228 ft2 0.1 Wood 4 Under Attic (Unvented) M WIC 1 20 Blown 60ft2 0.1 Wood 5 Under Attic (Unvented) M WIC 2 20 Blown 28 ft2 0.1 Wood 6 Under Attic (Unvented) STORAGE 20 Blown 28ft2 0.1 Wood 7 Under Attic (Unvented) UTILITY 20 Blown 66 ft2 0.1 Wood 8 Under Attic (Unvented) LAUNDRY 20 Blown 48 ft2 0.1 Wood 9 Under Attic (Unvented) FOYER 20 Blown 70 ft2 0.1 Wood 10 Under Attic (Unvented) BEDROOM 3 20 Blown 166 ft2 0.1 Wood 11 Under Attic (Unvented) KITCHEN 20 Blown 165 ft2 0.1 Wood 12 Under Attic (U nvented) CAFE 20 Blown 130ft2 0.1 Wood 13 Under Attic (Unvented) FAMILY ROOM 20 Blown 267 ft2 0.1 Wood 14 Under Attic (U nvented) HALL 20 Blown 32ft2 0.1 Wood 15 Under Attic (Unvented) BATH 2 20 Blown 56 ft2 0.1 Wood 16 Under Attic (Unvented) CLST 2 20 Blown 16 ft2 0.1 Wood 17 Under Attic (Unvented) BEDROOM 2 20 Blown 164 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block - Ext Insul M BATH 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 2 W Exterior Concrete Block - Ext Insul M BATH 4.1 7 0 10 0 70.0 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Ext InsulM TOILET 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Ext InsLW1ASTER BE 4.1 14 0 10 0 140.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Ext Insul M W IC 1 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 6 S Exterior Concrete Block - Ext InsuISTORAGE 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 7 S Exterior Concrete Block - Ext Insul UTILITY 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 8 S Exterior Concrete Block - Ext InsuILAUNDRY 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 9 W Exterior Concrete Block - Ext InsuILAUNDRY 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 10 S Exterior Concrete Block - Ext Insul FOYER 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 11 S Exterior Concrete Block - Ext InstBEDROOM 3 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 12 W Exterior Concrete Block - Ext InstSEDROOM 3 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 13 N Exterior Concrete Block - Ext Insul CAFE 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 14 E Exterior Concrete Block- Ext Insul CAFE 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 15 N Exterior Concrete Block - Ext InsdHAMILY ROO 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 16 NE Exterior Concrete Block - Ext Ins81AMILY ROO 4.1 4 3 10 0 42.5 ft2 0 0 0.6 0 17 E Exterior Concrete Block - Ext InsSAMILY ROO 4.1 10 0 10 0 100.0 ft2 0 0 0.6 0 18 N Exterior Concrete Block- Ext Insul HALL 4.1 4 0 10 0 40.0 ft2 0 0 0.6 0 19 N Exterior Concrete Block - Ext Insul BATH 2 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 20 E Exterior Concrete Block - Ext Insul BATH 2 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 21 E Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 _ 22 E Exterior Concrete Block - Ext InstBEDROOM 2 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 23 S Exterior Concrete Block - Ext InsMEDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 24 N Garage Frame - Wood M W IC 1 11 8 8 64.0 ft2 0 0 0.600000 0 _ 25 W Garage Frame - Wood M W IC 1 11 3 8 24.0 ft2 0 0 0.600000 0 _ 26 E Garage Frame - Wood STORAGE 11 6 8 48.0 ft2 0 0 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated FOYER None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.34 0.22 6.0 ft2 1 ft 0 in 1 ft 4 in None None 2 W 4 Metal Low-E Single Yes 0.34 0.22 8.0 ft2 1 ft 0 in 1 ft 4 in None None 3 S 8 Metal Low-E Single Yes 0.34 0.22 6.0 ft2 1 ft 0 in 1 ft 4 in None None 4 S 10 Metal Low-E Single Yes 0.34 0.22 3.0 ft2 1 ft 0 in 1 ft 4 in None None 5 S 11 Metal Low-E Single Yes 0.34 0.22 8.0 ft2 1 ft 0 in 1 ft 4 in None None 6 N 13 Metal Low-E Single Yes 0.34 0.22 12.0 ft2 1 ft 0 in 1 ft 4 in None None 7 E 14 Metal Low-E Single Yes 0.28 0.18 15.0 ft2 1 ft 0 in 1 ft 4 in None None 8 N 15 Metal Low-E Single Yes 0.34 0.22 45.0 ft2 1 ft 0 in 1 ft 4 in None None 9 NE 16 Metal Low-E Single Yes 0.33 0.16 20.0 ft2 1 ft 0 in 1 ft 4 in None None 10 E 17 Metal Low-E Single Yes 0.34 0.22 45.0 ft2 1 ft 0 in 1 ft 4 in None None 11 N 18 Metal Low-E Single Yes 0.33 0.16 20.0 ft2 1 ft 0 in 1 ft 4 in None None 12 E 20 Metal Low-E Single Yes 0.34 0.22 6.0 ft2 1 ft 0 in 1 ft 4 in None None 13 S 23 Metal Low-E Single Yes 0.28 0.18 8.0 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 576 ft2 384 ft2 17 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000445 1918 105.3 198.02 .3247 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COP:1 27 kBtu/hr 1 sys#1 11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 30 kBtu/hr 900 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.99 1 gal 55.1 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS — Supply — V — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage Garage (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: CoolingJan Feb HeatinJan Feb Mar Mar Apr Apr Me Jun Jul May Jun Jul Au 4 AuSep Se f Oct Oct [ ] Nov [X] Nov [ ] Dec [X] Dec Vent in Jan Feb Mar Apr [ May Jun Jul l [ Aug Se [Xj Oct [X] Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 11/16/201711:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: LICAUSI RESIDENCE LOT 4 Builder Name: Street: 4905 RIVER PLACE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: STEVE AND MARILYN LICAUSI Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/16/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 87 The lower the EnergyPerformance Index, the more efficient the home. i 4905 RIVER PLACE, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1832.50 ft2 b. Frame - Wood, Adjacent R=11.0 136.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1644.00 ftZ 6. Conditioned floor area (ftZ) 1644 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=0.34 139.00 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Garage R ft2 6 140 SHGC: SHGC=0.22 b. U-Factor: Sgl, U=0.33 40.00 ft2 SHGC: SHGC=0.16 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.28 23.00 ft2 a. Central Unit 30.0 SEER:16.00 SHGC: SHGC=0.18 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.204 8. Floor Types Insulation Area 14. Hot water systems Cap: 1 gallons a. Slab -On -Grade Edge Insulation R=0.0 1644.00 ft2 a. Electric EF: 0.99 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building. Construction through the above energy saving features which will be installed (or exceeded) in this home before final in�pe tion. Otherwis , a new EPL Display Card will be completed based on installed Code co iant fea es GAL s Builder Signature: Date: ZZ Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/16/2017 11:50 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1