HomeMy WebLinkAboutREVISED ELEVATION CERTIFICATE 2-13-19• r
U.S. DEPARTMENT OF HOMELAND SEi`,,__-JTY '� %� (CANNED OMB No. 1660-0008
Federal Emergency Management Agency National Flood Insurance Program BY�I Expiration Date: November 30; 2018
ELEVATION CERT�F�l& E
Important: Follow the instructions on pages 1-9.
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
SECTION A — PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
Al. Building Owner's Name
Policy Number:
STEVE AND MARILYN LICAUSI
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Company NAIC Number:
Box No.
.4905 RIVER PLACE
City State ZIP Code
FORT PIERCE Florida 34982
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
LOT 4 OF RIVER PLACE
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL
A5. Latitude/Longitude: Lat. 22-22-30 NORTH Long. 80-20-32 WEST Horizontal Datum: 0 NAD 1927 Fx� NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is -being used to obtain flood insurance.
A7. Building Diagram Number 1A s3
A8. For a building with a crawlspace or enclosure(s):
a) Square footage of crawlspace or enclosure(s) sq ft
b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade
c) Total net area of flood openings in A8.b sq in
d) Engineered flood openings? ❑ Yes ❑ No
A9. For a building with an attached garage:
a) Square footage of attached garage 373 sq ft
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade
c) Total net area of flood openings in A9.b sq in
d) Engineered flood openings? Yes ❑ No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
B2. County Name
B3. State
UNINCORPORATED 120285
ST. LUCIE
Florida =;
B4. Map/Panel
Number
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s)
Date
Effective/
Zone(s)
(Zone AO, use Base Flood Depth)
Revised Date
12111 CO 189
J
2/16/2012
2/16/2012
"AE"
7-
810. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item 139:
❑ FIS Profile 0 FIRM ❑ Community Determined Other/Source:
' B11. Indicate elevation datum used for BFE in Item 69: ❑ NGVD 1929 0 NAVD 1988 ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? Yes 0 No
Designation Date: F1 CBRS ❑ OPA
FEMA Form,086-0-33 (7115) Replaces all previous editions. Form Page 1 of 6
ELEVATION CERTIFICATE
-_`OMB No. 1660-0008
Expiration Date: November•30, 2018
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
4905 RIVER PLACE
City State ZIP Code
Company NAIC Number
FORT PIERCE FLORIDA W 34982
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ❑X Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations — Zones Al—A30, AE, AH, A (with BFE), VE, VI—V30, V (with BFE), AR, AR/A, AR/AE, AR/A1—A30, AR/AH, AR/AO.
Complete Items C2.a—h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters.
Benchmark Utilized: COUNTY BENCHMARK "BRIDGE" Vertical Datum: N.A.V.D.-88, ELEVATION=13.61'
Indicate elevation datum used for the elevations in items a) through h) below.
❑ NGVD 1929 ❑X NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 9.03 ❑X feet ❑ meters
b) Top of the next higher floor NA ❑ feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only) NA ❑ feet ❑ meters
d) Attached garage (top of slab) 8.49 ❑X feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building g 65' feet ❑meters
(Describe type of equipment and location in Comments)
f) Lowest adjacent (finished) grade next to building (LAG) 8.3 ❑x feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG) 8.6 ❑x feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including
structural support NA ❑ feet ❑ meters
SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
I certify that the information on this Certificate represents my best efforts to interpret the data available. ! understand that any false
statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by a licensed land surveyor? ❑X Yes ❑ No ❑ Check here if attac ents.
Certifier's Name License Number
CLINTON A. MITCHELL, R.L.S. LS3541
Title
REGISTERED LAND SURVEYOR AND MAPPER
Company Name
C.A. MITCHELL AND ASSOCIATES, INC. LB4276
re
Address
759 S.W. SOUTH MACEDO BOULEVARD
City State ZIP Code
PORT T. IE Florida 34983
Sign Date Telephone
FEB.4,2019 772-878-7547
opy all s "f t is Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
Comments (including type of equipment and location, per C2(e), if applicable)
A9(a) IS ACTUALLY AN OPEN CARPORT
C2(e) IS THE OUTDOOR A.C. SLAB AND UTILITY ROOM ACCESSIBLE FROM REAR OF CARPORT.
C2(d) IS THE LOWER EDGE OF THE CARPORT ENTRY.(CAR PORT -NO INCLOSED GARAGE)
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6