Loading...
HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION & FINAL APPROVAL 2-8-19APPLICATION #:AP1362506 l 56 SF 1633398 " STATE OF FLORIDA PERMIT # : - - DEPARTMENT OF HEALTH DOCUMENT # : F 11265199 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM 08/31/2018 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID: FEE PAID:300.00 RECEIPT #:56-PID-3683698 APPLICANT: Steve LICauSI AGENT: PROPERTY ADDRESS: 4905 River Place Port Saint Lucie FL 34983 M LOT: BLOCK: FEB 1 1 ?�1�, SUBDIVISION: River Place ID#: 3404-601-0006-000-9 PC 9 V-�— CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORREC7�Dljk26.prnuM'1 TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 1020.00 [21 1050.00 1: 1 [27] SURFACE WATER 93 FT [ ] [021 TANK MATERIAL Concrete [ ] (281 DITCHES PT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS FT [ ] [04] MULTI -CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER [ ] [311 IRRIGATION WELLS FT [ ] 1063 LEGEND 1, 01-011-AK8C3 2. 01-011-09DC3 [ ] [321 POTABLE WATER FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS $ FT [ ] [08] LEVEL [ ] [341 PROPERTY LINES 5 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] (101 AREA [1] 400 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER x [ l [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 4.00 2. [ ] [381 SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 02/08/2019 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 13.00 [ ] [401 UNOBSTRUCTED AREA [ ] 1171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS 1.00 [ ] [421 ALARMS [ ] [19] AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [451 LOCATION CONFORMS WITH SITE PLAN [ ] [211 AGGREGATE DEPTH [ ] [461 FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ 7 [47] CONTRACTOR David Whiteside (Accurate Se [ ] [22] AMOUNTS FILL AMOUNT [ l [48] OTHER Drip Irrigation - Netafim [ ] [23] FILL [ ] [241 EXCAVATION DEPTH ABANDONMENT I ] [253 AREA REPLACED [ l [49] TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] 150] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / St. Lucie CHD DATE: 12/28/2018 DISAPPROVED ] ° Environmental Specialis rian J gram (ENVIRONMENTAL HEALTH) 1 FINAL SYSTEM [ APPROVED / DISAPPROVED ] : St. Lucie CHD DATE: 02/08/2019 Environmental Specialist II Br J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Page 2 of 3 Incorporated: 64E-6.003, PAC EH Database v 1.0.1 AP1362506 EID1633396 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment —4.a APPLICATION #:AP1362506 PERMIT #:56-SF-1633398 DocuMENT # : FI 1265199 DATE PAID : 08/31 /2018 FEE PAID:300.00 RECEIPT #:56-PID-3683698 The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd. New 1020 gal 800GPD 01-011-AK8-C3 ATU, 1050 Gal DT, Netafim ArKL 130 micron filter, achaefer 20LE05PA-2W115.5HP pump, and 200 linear feat of Netafim drip line installed as trench. No violations, system ok to cover. Contractor notified onsite. Needs final inspection potable well inspection and setback, potable water line setback, mound system, alarm check, maintenance agreement, final site grading, ATU operating permit, and written notice of ATU. Final system approved. Contractor and building department emailed final approval. DU 4016, 08/09 (obsoletes all previous editions which may not be used) Page 2 of 3 Incorporated: 64E-6.003, PAC EH Database v 1.0.1 AP1362506 EID1633398