HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION & FINAL APPROVAL 8-31-18/600r, t:SCr' APPLICATION #:AP1362506. STATE OF FLORIDA PERMIT #:56=SF-1633.398 DEPARTMENT OF HEALTH DISPOSAL SYSTEM DOCUMENT #:F1126.5199 ONSITE SEWAGE TREATMENT AND DATE PAID_ /2018 CONSTRUCTION INSPECTION AND FINAL APPROVAL who p FEE PAID:300.00, SCANNED RECEIPT #:56-PID-3683698 By APPLICANT: Steve Licausi 3 P I Ai;tt" v I� AGENT: PROPERTY ADDRESS: 4905 River Place Port Saint Lucie, FL 34983 LOT: BLOCK: SUBDIVISION: River Place ID#: '3404-601-0005-000-9 CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH, STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] (01] TANK SIZE [1] 1020.00 [21 1050.00 [. ] [271 SURFACE. WATER 93 FT [ ] [021 TANK MATERIAL Concrete [ ] [201 DITCHES FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS, FT [ ] [041 MULTI -CHAMBERED [ Y N ] [, ] [30]' PUBLIC WELLS FT [ ] [051 OUTLET FILTER [. ] [311' IRRIGATION WELLS FT [ ] [061 LEGEND 1. 01-011-AK8C3 2. 01-011-09DC3 [ ] 132] POTABLE WATER FT [. ] [071. WATERTIGHT [ .1 [33] BUILDING. FOUNDATIONS, $ FT [ ] [081 LEVEL [ ] [341 PROPERTY LINES 5 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER. FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] 1191 AREA [1] 400 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1, 4.00. 2. [ ] [363 SLOPES ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 02/08/2019 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL -INFORMATION ( ] [161 ELEVATION [ AHOVE / 5,ELOW ]BM 13,00 [ ]' [401 UNOBSTRUCTED AREA [ ] [17] SYSTEM,LOCATION [ ] [41.1 STORMWATER RUNOFF [ ] [181 DOSING PUMPS' 1.00 [ ] [42]. ALARMS. [ ] [19,1 AGGREGATE SIZE [ ] [43'] MAINTENANCE AGREEMENT [ J [201 AGGREGATE EXCESSIVE FINES [ ] [44'] BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN [ ] [4'6] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [47] CONTRACTOR Davin Whiteside, (Accurate Se [ ] [22] FILL AMOUNT [ ] [48] OTHER nfim Drip Irrigatio-Neta [ ] [231 FILL TEXTURE [ J [241 EXCAVATION DEPTH ABANDONMENT I ] [251 AREA REPLACED [ ] [49.1 TANK PUMPED [ ] [2.6] REPLACEMENT MATERIAL [' ] [50] TANK CRUSHED 6 FILLED Comments: Comments are on page 2. I APPROVED / St. Lucie CHD DATE: 12/28/2018 CONSTRUCTION DISA-PPROVED ] ' Envlrbnmefital SpeclWis flan J gram (ENVIRONMENTAL HEALTH) -1_ FINAL SYSTEM [ APPROVED / DISAPPROVED 1: St. Lucie CHD DATE,: 02/08/2019 Environmental` Specialist 11 Br J Ingram '(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page). DH 4016, 00/09 (Obsoletes all. previous editions which may not be used) Page 2 0£ 3 Incorporated: 64E-6.003, FAC EH Database v 1.0.1 A01362506 EID1633398 1 Ky(E n i 7l. STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT' AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL we Violation Number Comment APPLICATION #:API.362506 PERMIT #:56-SF=1633398 DOWMENT #:: F11265199 DATE PAID:08/31/2018, FEE PAID.:300.00 RECEIPT. #:56-PID-:3683.698 The system is sized for 3 bedrooms with a maximum occupancy�of 6 persons (2 per bedroom), for a total estimated flow of 300 gpd• New 10Mgal 800GPD 01-011-AK8-C3 ATU, 105.0 Gal DT, Netafim ArKL 150 micron filter, achaefer20LE05PA-2W115..5HP pump, and 200 linear feat of Netafim drip line installed as french. 'Nd violations, system ok to. cover. Contractor' notified onsite. Needs final inspection potable well inspection and setback, potable waterline setback„mound system; alarm check, maintenance agreement, final site grading, ATU. operating permit, and written notice of'ATU. Final system approved. Contractor and building department emailed final approval.. DH 4016, 06/09 (Obsoletes all previous editions which.may not be used) Incorporated: 64E-6.063, FAC Page 2 of .3 EH Database v 1.0.1 AP1362506 EID1633398