Loading...
HomeMy WebLinkAboutSEWAGE SITE EVALUATION & SYSTEM SPECIFICATIONSo1F � s STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM %p SITE EVALUATION AND SYSTEM SPECIFICATIONS APPLICANT: Steve LiCausi AGENT: '//y / 1 (,gc) PERMIT # LOT: 3 BLOCK: -- SUBDIVISION: River Place (4509 River Place) PROPERTY ID #: 3404-6n1-nnns-nnn_o [Section/Township/Parcel No. or Tax ID Number] TO BE COMPLETED BY ENGINEER, HEALTH DEPARTEMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: TOTAL ESTIMATED SEWAGE FLOW: 300 AUTHORIZED SEWAGE FLOW: 630 UNOBSTRUCTED AREA AVAILABLE: >700 [X] YES [ ] NO NET USABLE AREA AVAILABLE: 0.42 ACRES _GALLONS PER DAY [RESIDENCES -TABLE 1/OTHER-TABLE21 _GALLONS PER DAY [XXXX GPD/ACRE OR 1500 GPD/ACRE] _SQFT UNOBSTRUCTED AREA REQUIRED: 563 SQFT BENCHMARK/REFERENCE POINT LOCATION: survey pin w/Yellow cap center of cul-de-sac (Elev. 5.541 NAVD) ELEVATION OF PROPOSED SYSTEM SITE IS 8 [INCHES] [ABOVE]. BENCHMARK THE MINIMUM SETBACK THAT CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: 111 FT DITCHES/SWALES: n/a FT NORMALLY WET? WELLS: PUBLIC: n/a FT LIMITED USE: n/a FT PRIVATE: 87 FT NON -POTABLES 81?3 -OFT BUILDING FOUNDATIONS: 7.9 FT PROPERTY LINES. 5.2 FT POTABLE WATER LINES: 84.4 FT SITE SUBJECT TO FREQUENT FLOODING: 10 YEAR FLOOD ELEVATION FOR SITE: [ ] YES '[X] NO -- FT MSL/NGVD SOIL PROFILE INFORMATION SITE 1- 8" above IMUN6ELL #/COLOR TEXTURE DEPTH 10YR 2/1,4/2,3/PFSISC-fill 0 TO 16 10YR 4/2 16 TO 23 7.5YR 3/1 23 TO 27 10YR 4/2 2/5/4 27 TO 34 10YR 5/4 34 TO 39 l0YR 6/2 FS 39 TO 41 Refusal- GW Mapped As: Ankona & Farmton Unable to determine series 10 YEAR FLOODING? [ ] YES [X] NO SITE ELEVATION: -- FT MSL/NGVD SOTT, PRnFTT.V TAIL-nnnnnmr��� /COLOR L TEXTURE v ajjvvc DEPTH 4/2.,3/1 FS/SC-fill 0 TO 28 WilOYR6/3 FS- t org's 28 TO 43 FS 43 TO 48 FS 48 TO 50 Refusal- GW Mapped AsT Ankona & Farmton Unable to determine series OBSERVED WATER TABLE:_ 33 INCHES [xxxx/ BELOW] EXISTING GRADE. TYPE:[xxxxxxx/ APPARENT]I ESTIMATED WET SEASON WATER TABLE ELEVATION: 27 INCHES [xxxx /BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: [ ] YES [X] NO MOTTLING: [X] YES . [ ] NO DEPTH: 27 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: FS/0.8 DEP)jk"b'FoEXCAVATION: 43 INCHES DRAINFIELD CONFIGURATION: [X ] TRENCH �-� [ 7 BED [ ] OTHER\ (SPECI'IFY)''�, REMARKS/ADDITIONAL CRITERIA:_ common fine prominent 5YR 5/6,re�-ox':'ccncen•tr�tions at 27" in boring 1, stripped matrix (lOYR 5/4 & 5/4+) startin at,,34";ei,i 1I.nie bo ' organics gf t orq' s- w/high SITE EVALUATED BY:�, Scott M. Franz, CPSs- Soil Scientist (Cert. #25044) (407) 38 6 6 ' , DATE: 14 Jan 16 DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorp6 d: 64E-6.00.1, FAC Page 3 of 4