Loading...
HomeMy WebLinkAboutBLOWER DOOR TEST FORM 8-22-18Date: I= Contractor: Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM AUG 2 2 2018 House Infiltration Test Certification [!r Prescriptive and Performance Method r�fitting Department t. Lucie C®untY FL Permit #: �-7 / Z 19 jj -7J— Job Address: °Z_ _ o 3 Construction: (X) New Construction — Complete House Infiltration Test Results SLC Climate Zone 2 CFM (50) = d Volume = 2 7 9Y, 0 ACH (50) = CFM (50) x 60 / Volume = 0 Passing results must be & ACH (50) or less Test Date: f/ (vC ( ) Existing — After Addition r- Za-/";— McFhanical Ventilation required less than 5 ACH nA Pass ( ) Fail FBC, (Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC, Residential Where the air infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in accordance with Section M1507.3. Testing Company Company Name: Pro Duct Services Address: 1915 Rio Vista dr., Fort Pierce, fl. I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: Michael Faurot License/Certification #: 5059122 Planning & Development Services Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 772462-2165 Fax 772462-6443 FBC ENERGY CONSERVATION CODE Duct Sealing Certification Prescriptive and Performance Method Date: Z, C) Permit #: f / 2 — 67 S Lot #: Contractor. Address: Z 5'--(53 6A u Construction: Ast Construction Test ❑ Rough4n Test Test Conditions: Date: Z a - /r Floor Area (ft2): 2 y3� Time: 8 .3 D Primary Location of Supply Ductwork�� Indoor Temperature (F): %.- Primary Location of Return Ductwork Outdoor Temperature (F): Duct Leakage: j4ie—�ult ❑ Prop. Leak Free Test Pressure: 7 A �rPa) Baseline Duct Pressure (optional) O ! (Pa) Duct Press. (Pa) Flow Ring Fan !0llow s Installed Pa 0 Z —7 •� Testing Company Company Name: Pro Duct Services ❑ Proposed On = nu rass ❑ fail Total Leakage (cfm): _o Total Leakage per 100 sgft: 01 CFM25 x 100 divided by the CFA = Duct Leakage CFM/100 sgft. Address: 1915 Rio Vista Dr., Fort Pierce, FI. I hereby certify that the above Duct Sealing Leakage results demonstrate compliance with 5u, Edition FBC Energy Conservation requirements in accordance with Section R403.2.2. Signature: Printed Name: Michael Faurot License/Certificate #: 5059122 AUG 22MM Permittingr St. Lucie County, FL BUILDING PERFORMANCE INSTITUTE, INC 107 Hermes Road, Suite 210 Malta, NY 12020 `- (877) 274-1274 www.bpi.org, _ BPI Michael Faurot BPI ID#: 5059122 CERTIFIED PROFESSIONAL o'> (SEE REVERSE SIDE FOR DESIGNATIONS AND EXPIRATION DATES) 4