Loading...
HomeMy WebLinkAboutEPL DISPLAY CARDz FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD 7, m ESTIMATED ENERGY PERFORMANCE INDEX* = 96 I k The lower the EnergyPerformance Index, the more efficient the home. t DEC 2 8 DYER ROAD, FORT PIERCE FL 3Yi- New-aonstruction,orexisting New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext lnsul, Exterior R=4.1 2784.40 ftx b. Frame- Wood, Adjacent R=11.0 280.00 ftx 3. Number of units, If multiple family 1 c. N/A R= ftx 4. Number of Bedrooms 4 d. N/A R= ftx 5. Is this a worst case? No 10. Ceiling Types Insulation Area a. Roof Deck (Unvented) R=20.0 2436.00 ftx 6. Conditioned floor area (ftx) 2436 b. N/A R= ftx 7. Windows"" Description Area R fx a. U-Factor: Sgl, U=0.65 11 Ducts 236.33 ftx a. Sup: Attic, Rat Attic, AH: AHU R ftx 6 175 SHGC: SHGC=0:25 b. 0-Factor.- Sgl, U=0.65 192.00 ftx SHGC: SHGC=0.30 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.65 49.00 ftx a. Central Unit 42.0 SEER:16.00 SHGC: SHGC=0.32 d. U-Factor: N/A ftx SHGC: 13. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 2.000 ft. a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average SHGC: 0.277 8. Floor Types Insulation Area 14. Hot water systems a. Slab -On -Grade Edge Insulation R=0.0 2436.00 ftx a. Electric Cap: 50 gallons b. N/A R= ftx EF: 0.98 c. N/A R= ftx b. Conservation features None 15. Credits None I c rtify that this home has C nstruction through the a in this home before final in on installed 'r< Address of New Home: with the Florida Energy Efficiency Code for Building gy saving features which will be installed (or exceedec rwise, a new EPL Display Card will be co pleted tur s Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/31 /201711:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1 File Copy FORM R405-2014 FLORIDA ENERGY EFFICIENCY( CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: MAY RESIDENCE Street: DYER ROAD City, State, Zip: FORT PIERCE, FL, Owner. Design Location: FL, Fort Pierce Builder Name: GEM BUILDERS Permit Office: ST LUCIE COUNTY Permit Number: Jurisdiction: County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3064.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - EXt Insul, Exterior R=4.1 2784AO ft2 3. Number of units, if multiple family 1 b. Frame -Wood, Adjacent c. N/A R=11.0 280.00 ft2 R= ft2 4. Number of Bedrooms 4 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types (2436.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2436.00 ft2 6. Conditioned floor area above grade (ft2) 2436 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 °• A R= ft2 7. Windows (477.3 sqft.) Description Area 11. Ducts a. Sup: Attic, Ret: Attic, AH: AHU R ft2 6 175 a: U-Factor: Sgl, U=0.65 236.33 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.65 192.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 42.0 SEER:16.00 c. U-Factor: Sgl, U=0.65 49.00 fN SHGC: SHGC=0.32 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.277 14. Hot water systems 8. Floor Types (2436.0 sqft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 2436.00 ft2 b. Conservation features EF: 0.980 b. N/A R= ft2 None c. N/A R= ft2 15. Credits None Glass/Floor Area: 0.196 Total Proposed Modified Loads: 88.66 �c PASS ®�Ss Total Baseline ! oads: 92.20 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code, t'1' _ >� r-z/'1 ^ PR I kereby certify that this ° ui g, as designed, is in compliance wWL.the Florida E e. DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: - Compliance requires ce fication Ify the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed 16 accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 this project requires an envelope.leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2). 10/31/2017 11:59 AM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 7 FORM R405-2014 PROJECT Title: MAY RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2436 Lot # Owner. Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: GEM BUILDERS Rotate Angle: 0 Street: DYER ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/E)dsting: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days. Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2436 27990 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infii ID Finished Cooled Heated 1 BEDROOM 2 156 1560 No 0 1 1 Yes Yes Yes 2 CLST 2 18 180 No 0 1 Yes Yes Yes 3 BATH 2 45 450 No 0 1 Yes Yes Yes 4 CLST 3 18 180 No 0 1 Yes Yes Yes 5 BEDROOM 3 143 1430 No 0 1 1 Yes Yes Yes 6 BATH 3 72 720 No 0 1 Yes Yes Yes f 7 BEDROOM 4 168 1680 No 1 1 1 Yes Yes Yes 8 CLST 4 14 140 No 0 1 Yes Yes Yes 9 HALL 3 40 400 No 0 1 No Yes Yes 10 HALL 2 28 280 No 0 1 Yes Yes Yes 11 FAMILY 224 2464 No 0 1 Yes Yes Yes 12 CAFE 161 2254 No 0 1 Yes Yes Yes 13 KITCHEN 192 2688 Yes 0 1 No Yes Yes 14 LAUNDRY RM 44 440 No 0 1 No Yes Yes 15 AHU 12 120 No 0 1 No Yes Yes 16 DINING 156 2184 No 0 1 Yes Yes Yes 17 FOYER 73 1022 No 0 1 Yes Yes Yes 18 M WIC 2 56 560 No 0 1 No Yes Yes 19 MASTER BEDROO 290 3190 No 0 1 1 Yes Yes Yes 20 M WIC 1 64 640 No 0 1 Yes Yes Yes 21 MASTER BATH 235 2350 No 0 1 Yes Yes Yes 22 M TOILET 30 300 No 0 1 Yes Yes Yes 10/31/2017 11:59 AM EnergyGaugew) USA r v5.1 - Section R405.4.1 Compliant Software Page 2 of 7 . FORM R405-2014 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 23 LIVING ROOM 197 2758 No 0 1 Yes Yes Yes FLOORS 4 Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 2 37 ft 0 156 ft2 __ 1 0 0 2 Slab -On -Grade Edge Insulation CLST 2 2 ft 0 18 ft2 1 0 0 3 Slab -On -Grade Edge Insulation BATH 2 5 ft 0 45 ft2 ___ 1 0 0 4SIab-On-Grade Edge Insulation CLST 3 2 ft 0 18 ft2 1 0 0 5SIab-On-Grade Edge Insulation BEDROOM 3 lift 0 143 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation BATH 3 8 ft 0 72 ft2 1 0 0 7 Slab -On -Grade Edge Insulation BEDROOM 4 12 ft 0 168 ft2 __ 1 0 0 8 Slab -On -Grade Edge Insulation CLST 4 2 ft 0 14 ft2 ___ 1 0 0 9 Slab -On -Grade Edge Insulation I HALL 3 1 ft 0 40 ft2 __ 1 0 0 10SIab-On-Grade Edge Insulation HALL 2 3 ft 0 28 ft2 ___ 1 0 0 i 11SIab-On-Grade Edge Insulation I FAMILY 30 ft 0 224 ft2 ___ 1 0 0 I 12SIab-On-Grade Edge Insulation CAFE 16 ft 0 161 ft2 ___ 1 0 0 13SIab-On-Grade Edge Insulation KITCHEN 1 ft 0 192 ft2 ___ 1 0 0 14SIab-On-Grade Edge Insulation LAUNDRY RM 1 ft 0 44 ft2 1 0 0 IIII, 15SIab-On-Grade Edge Insulation AHU 1 ft 0 12 ft2 ___ 1 0 0 i 16SIab-On-Grade Edge Insulation DINING 14 ft 0 156 ft2 ___ 1 0 0 17SIab-On-Grade Edge Insulation FOYER 8 ft 0 73 ft2 ____ 1 0 0 18SIab-On-Gr2de Edge Insulation i M W IC 2 1 ft 0 56 ft2 1 0 0 19SIab-On-Grade Edge Insulation MASTER BEDRO 36.6 ft 0 290 ft2 ____ 1 0 0 20SIab-On-Grade Edge Insulation M W IC 1 10 ft 0 64 ft2 1 0 0 21SIab-On-Grade Edge Insulation MASTER BATH 35 ft 0 235 112 __-_ 1 0 0 22SIab-On-Grade Edge Insulation i M TOILET lift 0 30 ft2 ____ 1 0 0 ` 23Slab-On-Grade Edge Insulation LIVING ROOM 10 ft 0 197 ft2 ----1 0 0 101311201711:59 AM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 7 FORM R405-2014 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2724 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC 1 V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2436 ft2 N N II I! CEILING 1 V # Ceiling Type Space R-Value. Ins Type Area Framing Frac Truss Type I 1 Under Attic (Unvented) BEDROOM 2 20 Blown 156ft2 0.1 Wood 2 Under Attic (Unvented) CLST 2 20 Blown 18 ft2 0.1 Wood j 3 Under Attic (Unvented) BATH 2 20 Blown 45 ft2 0.1 Wood i 4 Under Attic (Unvented) CLST 3 20 Blown 18 ft2 0.1 Wood jj 5 Under Attic (Unvented) BEDROOM 3 20 Blown 143 ft2 0.1 Wood 6 Under Attic (Unvented) BATH 3 20 Blown 72 ft2 0.1 Wood I 7 Under Attic (Unvented) BEDROOM 4 20 Blown 168 ft2 0.1 Wood 8 Under Attic (Unvented) CLST 4 20 Blown 14 ft2 0.1 Wood I 9 Under Attic (Unvented) HALL 3 20 Blown 40 ft2 0.1 Wood 10 Under Attic (Unvented) HALL 2 20 Blown 28 ft2 0.1 Wood 11 Under Attic (U nvented) FAMILY 20 Blown 224ft2 0.1 Wood �! 12 Under Attic (Unvented) CAFE 20 Blown 161 ft2 0.1 Wood 13 Under Attic (U nvented) KITCHEN 20 Blown 192ft2 0.1 Wood i 14 Under Attic (Unvented) LAUNDRY RM 20 Blown 44 ft2 0.1 Wood l 15 Under Attic (Unvented) AHU 20 Blown 12 ft2 0.1 Wood 16 Under Attic (Unvented) DINING 20 Blown 156ft2 0.1 Wood 17 Under Attic (Unvented) FOYER 20 Blown 73 ft2 0.1 Wood 18 Under Attic (Unvented) M WIC 2 20 Blown 56 ft2 0.1 Wood s 19 Under Attic (Unvented) MASTER BEDRO 20 Blown 290 ft2 0.1 Wood 20 Under Attic (Unvented) M WIC 1 20 Blown 64 ft2 0.1 Wood 21 Under Attic (Unvented) MASTER BATH 20 Blown 235 ft2 0.1 Wood 22 Under Attic (Unvented) M TOILET 20 Blown 30 ft2 0.1 Wood ' I 23 Under Attic (Unvented) LIVING ROOM 20 Blown 197 ft2 0.1 Wood I WALLS / Adjacent Space Cavity Width Height Sheathing Framing Solar Below V22 C11111. 1 T i Pa -P In - o l _ 1 N Exterior Concrete Block - Ext Ins1BEDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 2 N S Exterior Concrete 5lock - Ext InsLBEDROOM 2 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 " 3 - W Exterior Concrete Block - Ext Insd9EDROOM.2 4.1 13 0 10 0 130.0 ft2 0 0 0.6 0 - 4 S Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0, 10 0 20.0 ft2 0 0 0.6 0 - 5 S Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0' 10 0 50.0 ft2 0 0 0.6 0 - 6 S Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 10/31/2017 11:59 AM EnergyGauga USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 7 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below o _ 7 S Exterior Concrete Block - Ext InstBEDROOM 3 4.1 11 0 10 0 110.0 ft2 0 0 0.6 0 8 S Exterior Concrete Block - Ext Insul BATH 3 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 _ 9 S Exterior Concrete Block - Ext InsSEDROOM 4 4.1 12 0 10 0 120.0 ftz 0 0 0.6 0 _ 10 S Exterior Concrete Block - Ext Insul CLST 4 4.1 2 0 10 0 20.0 ft2 0 .0 0.6 0 11 N Exterior Concrete Block - Ext Insul HALL 2 4.1 3 0 10 0 30.0 ft2 0 0 0.6 0 _ 12 N Exterior Concrete Block - Ext Insul FAMILY 4.1 14 0 11 0 164.0 ft2 0 0 0.6 0 _ 13 W Exterior Concrete Block - Ext Insul FAMILY 4.1 16 0 11 0 176.0 ft2 0 0 0.6 0 14 N Exterior Concrete Block - Ext Insul CAFE 4.1 11 0 14 0 154.0 ft2 0 0 0.6 0 _ 15 W Exterior Concrete Block -.Ext Insul CAFE 4:1 5 0 14 0 70.0 ft2 0 0 0.6 0 16 N Exterior Concrete Block - Ext Insul DINING 4.1 1 0 14 0 14.0 ft2 0 0 0.6 0 _ 17 E Exterior Concrete Block - Ext Insul DINING 4.1 13 0 14 0 182 0 ft2 0 0 0.6 0 _ 18 E Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 14 0 112.0 ft2 0 0 0.6 0 _ 19 N Exterior Concrete Block - Ext InsLKIASTER BE 4.1 18 0 11 0 198.0 ft2 0 0 0.6 0 20 SW Exterior Concrete Block - Ext InsMASTER BE 4.1 8 7 11 0 94.4 ft2 0 0 0.6 0 _ 21 I W Exterior Concrete Block - Ext InsiMASTER BE 4.1 10 0 11 0 110.0 ft2 0 0 0.6 0 22 N Exterior Concrete Block - Ext Insul M W IC 1 4.1 8 0 10 0 80.0 ft2 0 0 0.6 0 23 W Exterior Concrete Block - Ext Insul M W IC 1 4.1 2 0 10 0 20.0 ft2 0 0 0.6 0 24 N Exterior Concrete Block - Ext InstMASTER BA 4.1 9 0 10 0 90.0 ft2 0 0 0.6 0 25 E Exterior Concrete Block - Ext InsLMASTER BA 4.1 14 0 10 0 140:0 ft2 0 0 0.6 0 26 S Exterior Concrete Block - Ext InsdAASTER BA 4.1 12 0 10 0 120.0 ft2 0 0 0.6 0 li = 27 N Exterior Concrete Block - Ext InsulM TOILET 4.1 6 0 10 0 60.0 ft2 0 0 0.6 0 28 E Exterior Concrete Block - Ext InsulM TOILET 4.1 5 0 10 0 50.0 ft2 0 0 0.6 0 _ 29 W Exterior Concrete Block - Ext InsWIVING ROO 4.1 10 0 14 0 140.0 ft2 0. 0 0.6 0 i- 30 E Garage Frame - Wood LAUNDRY R 11 20 10 200.0 ft2 0 0 0.600000 0 -31 S Garage Frame -Wood DINING 11 8 10 80.0 ft2 0 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width, Height Area Ft in Ft In i 1 E Insulated FOYER None A 6 8 48 ft2 ' WINDOWS Orientation shown is the entered, Pro osed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.65 0.25 15.0 ft2 2 ft 0 in 1 ft 4 In None None 2 W 3 Metal Low-E Single Yes 0.65 0.25 15.0 ft2 2 ft 0 in 1 ft 4 In None None I 3 S 5 Metal Low-E Single Yes 0.65 0.25 6.0 ft2 2 ft 0 in 1 ft 4 in None None 4 S 7 Metal ' Low-E Single Yes 0.65 0.25 15.0 ft2 2 ft 0 in 1 ft 4 in None None 5 S 8 Metal Low-E Single Yes 0.65 0.25 6.0 ft2 2 ft 0 in 1 ft 4 in None None 6 S 9 Metal Low-E Single Yes 0.65 0.25 16.0 ft2 2 ft 0 in 1 ft 4 In None None 7 N 11 Metal Low-E Single Yes 0.65 0.2- 21.3 ft2 2 ft 0 in 1 ft 4 in None None 8 N 12 Metal Low-E Single Yes 0.65 0.3 72.0 ftz 2 ft 0 in 1 ft 4 In None None 9 W 13 Metal Low-E Single Yes 0.65 0.25 24.0 ft2 2 ft 0 in 1 ft 4 in None None 10/31/2017 11:59 AM , EnergyGauga USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 7 FORM R405-2014 WINDOWS Orientation shown is the entered, Proposed orientation. J Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 10 N 14 Metal Low-E Single Yes 0.65 0.25 20.0 ft' 2 ft 0 in 1 ft 4 in None None 11 W 15 Metal Low-E Single Yes 0.65 025 20.0 ft2 2 ft 0 in 1 ft 4 in None None 12 E 17 Metal Low-E Single Yes 0.65 0.25 30.0 ft' 2 ft 0 in 1 ft 4 in None None j 13 N 19 Metal Low-E Single Yes 0.65 0.25 20.0 ft2 2 ft 0 in 1 ft 4 in None None 14 SW 20 Metal Low-E Single Yes 0.65 0.3 48.0 ft' 2 ft 0 in 1 ft 4 In None None 15 W 21 Metal Low-E Single Yes 0.65 0.25 20.0 ft2 2 ft0 in 1 ft 4 in None None 16 E. 25 Metal Low-E Single Yes 0.65 0.32 49.0 ft2 2 ft 0 in 1 ft 4 in None None j 17 N 27 Metal Low-E Single Yes 0.65 0.25 9.0 ft2 2 ft 0 in 1 ft 4 in None None 18 i W 29 Metal Low-E Single Yes 0.65 0.3 72.0 ft2 2 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation �i 1 400 ft2 384 ft' 28 ft loft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 i 1 Wholehouse ProposedACH(50) .000511 3265.5 179.27 337.15 .3731 7 HEATING SYSTEM •• 1 -�...•.••. . yr� Electric Strip Heat ..u...yw None unw--y �.aPac Ly COP:1 27 kBtu/hr DI[AAl 1 UULAb sys#1 # System Type Subtype COOLING SYSTEM Efficiency Capacity Air Flow SHR Block Ducts �f 1 Central Unit Split SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 HOT WATER SYSTEM \ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 60.9 gal 120 deg None FSEC Cert # Company Name SOLAR HOT WATER SYSTEM Collector System Model /: Collector Model # Area Storage. Volume FEF None None ft2 10/31/2017 11:59 AM EnergyGauga USA - v5.1 - Section R405.4.1 Compliant Software Page 6 of 7 FORM R405-2014 DUCTS / -- Supply— — Return — Air CFM 25 CFM25 HVAC # V m Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool ? Attic 6 175 ft2 Attic 18 ft' Default Leakage AHU (Default) c(Default) c 1 1 I TEMPERATURES j Programable Thermostat: N Ceiling Fans: !1 Cooling Jan i Heating an Venting Feb Feb Mar �Cj Mar f Apr Apr f May May Jun Jul Jun Jul Auge Aug Sep E Oct Oct f Nov X} Nov Dec Dec H i Jan i Feb [[�Xl] Mar (X7 A r [ Ma Jun Jul Au Se [Xl Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours j Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 78 78 78 78 78 78 80 80 80 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 1 PM 80 80 80 80 78 78 78 78 78 78 78 78 i Heating (VdD) 68 68 PAM M 68 68 68 68 68 68 68 68 68 68 I Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 p PM 68 68 68 68 68 68 68 68 68 68 68 68 10/31/2017 11:59 AM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 7 of 7 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MAY RESIDENCE Builder Name: GEM BUILDERS Street: DYER ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned -with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers. shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawispace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Showerltub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots I HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors i vw uw: i i »:oa Am EnergyGauge® USA - v5.1 -Section R405.4.1 Compliant Software Page 1 of 1