HomeMy WebLinkAboutEPL DISPLAY CARDz
FORM R405-2014
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
7, m ESTIMATED ENERGY PERFORMANCE INDEX* = 96
I k The lower the
EnergyPerformance Index, the more efficient the home.
t DEC 2 8
DYER ROAD, FORT PIERCE FL
3Yi- New-aonstruction,orexisting
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Ext lnsul, Exterior
R=4.1
2784.40 ftx
b. Frame- Wood, Adjacent
R=11.0
280.00 ftx
3. Number of units, If multiple family
1 c. N/A
R=
ftx
4. Number of Bedrooms
4 d. N/A
R=
ftx
5. Is this a worst case?
No 10. Ceiling Types
Insulation
Area
a. Roof Deck (Unvented)
R=20.0
2436.00 ftx
6. Conditioned floor area (ftx)
2436 b. N/A
R=
ftx
7. Windows"" Description
Area
R
fx
a. U-Factor: Sgl, U=0.65
11 Ducts
236.33 ftx a. Sup: Attic, Rat Attic, AH: AHU
R ftx
6 175
SHGC: SHGC=0:25
b. 0-Factor.- Sgl, U=0.65
192.00 ftx
SHGC: SHGC=0.30
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Sgl, U=0.65
49.00 ftx a. Central Unit
42.0 SEER:16.00
SHGC: SHGC=0.32
d. U-Factor: N/A
ftx
SHGC:
13. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
2.000 ft. a. Electric Strip Heat
27.0
COP:1.00
Area Weighted Average SHGC:
0.277
8. Floor Types Insulation Area 14. Hot water systems
a. Slab -On -Grade Edge Insulation R=0.0 2436.00 ftx a. Electric
Cap: 50 gallons
b. N/A R=
ftx
EF: 0.98
c. N/A R=
ftx b. Conservation features
None
15. Credits
None
I c rtify that this home has
C nstruction through the a
in this home before final in
on installed 'r<
Address of New Home:
with the Florida Energy Efficiency Code for Building
gy saving features which will be installed (or exceedec
rwise, a new EPL Display Card will be co pleted
tur
s
Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/31 /201711:59 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1
File Copy
FORM R405-2014
FLORIDA ENERGY EFFICIENCY( CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name:
MAY RESIDENCE
Street:
DYER ROAD
City, State, Zip:
FORT PIERCE, FL,
Owner.
Design Location:
FL, Fort Pierce
Builder Name: GEM BUILDERS
Permit Office: ST LUCIE COUNTY
Permit Number:
Jurisdiction:
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (3064.4 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - EXt Insul, Exterior
R=4.1 2784AO ft2
3. Number of units, if multiple family
1
b. Frame -Wood, Adjacent
c. N/A
R=11.0 280.00 ft2
R= ft2
4. Number of Bedrooms
4
d. NIA
R= ft2
5. Is this a worst case?
No
10. Ceiling Types (2436.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2436.00 ft2
6. Conditioned floor area above grade (ft2)
2436
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
°• A
R= ft2
7. Windows (477.3 sqft.) Description
Area
11. Ducts
a. Sup: Attic, Ret: Attic, AH: AHU
R ft2
6 175
a: U-Factor: Sgl, U=0.65
236.33 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65
192.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
42.0 SEER:16.00
c. U-Factor: Sgl, U=0.65
49.00 fN
SHGC: SHGC=0.32
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft.
Area Weighted Average SHGC:
0.277
14. Hot water systems
8. Floor Types (2436.0 sqft.)
Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 2436.00 ft2
b. Conservation features
EF: 0.980
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
None
Glass/Floor Area: 0.196
Total Proposed Modified Loads: 88.66
�c
PASS
®�Ss
Total Baseline
! oads: 92.20
I hereby certify that the plans and specifications covered by
this calculation are in compliance with the Florida Energy
Code, t'1' _ >� r-z/'1 ^
PR
I kereby certify that this ° ui g, as designed, is in compliance
wWL.the Florida E e.
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- Compliance requires ce fication Ify the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed 16 accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
this project requires an envelope.leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
10/31/2017 11:59 AM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 7
FORM R405-2014
PROJECT
Title:
MAY RESIDENCE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2436
Lot #
Owner.
Total Stories:
1
Block/SubDivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
GEM BUILDERS
Rotate Angle:
0
Street:
DYER ROAD
Permit Office:
ST LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/E)dsting:
New (From Plans)
Comment:
CLIMATE
/
IECC
Design Temp
Int Design Temp
Heating
Design Daily Temp
v Design Location
TMY Site
Zone
97.5 %
2.5 %
Winter
Summer Degree Days. Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2436
27990
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
Infii ID
Finished Cooled
Heated
1
BEDROOM 2
156
1560 No
0
1
1
Yes
Yes
Yes
2
CLST 2
18
180 No
0
1
Yes
Yes
Yes
3
BATH 2
45
450 No
0
1
Yes
Yes
Yes
4
CLST 3
18
180 No
0
1
Yes
Yes
Yes
5
BEDROOM 3
143
1430 No
0
1
1
Yes
Yes
Yes
6
BATH 3
72
720 No
0
1
Yes
Yes
Yes
f 7
BEDROOM 4
168
1680 No
1
1
1
Yes
Yes
Yes
8
CLST 4
14
140 No
0
1
Yes
Yes
Yes
9
HALL 3
40
400 No
0
1
No
Yes
Yes
10
HALL 2
28
280 No
0
1
Yes
Yes
Yes
11
FAMILY
224
2464 No
0
1
Yes
Yes
Yes
12
CAFE
161
2254 No
0
1
Yes
Yes
Yes
13
KITCHEN
192
2688 Yes
0
1
No
Yes
Yes
14
LAUNDRY RM
44
440 No
0
1
No
Yes
Yes
15
AHU
12
120 No
0
1
No
Yes
Yes
16
DINING
156
2184 No
0
1
Yes
Yes
Yes
17
FOYER
73
1022 No
0
1
Yes
Yes
Yes
18
M WIC 2
56
560 No
0
1
No
Yes
Yes
19
MASTER BEDROO
290
3190 No
0
1
1
Yes
Yes
Yes
20
M WIC 1
64
640 No
0
1
Yes
Yes
Yes
21
MASTER BATH
235
2350 No
0
1
Yes
Yes
Yes
22
M TOILET
30
300 No
0
1
Yes
Yes
Yes
10/31/2017 11:59 AM EnergyGaugew) USA r v5.1 - Section R405.4.1 Compliant Software Page 2 of 7
. FORM R405-2014
SPACES
Number Name Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
23 LIVING ROOM 197 2758
No 0
1 Yes
Yes
Yes
FLOORS
4 Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 2
37 ft
0
156 ft2
__ 1
0
0
2 Slab -On -Grade Edge Insulation
CLST 2
2 ft
0
18 ft2
1
0
0
3 Slab -On -Grade Edge Insulation
BATH 2
5 ft
0
45 ft2
___ 1
0
0
4SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
18 ft2
1
0
0
5SIab-On-Grade Edge Insulation
BEDROOM 3
lift
0
143 ft2
____ 1
0
0
6 Slab -On -Grade Edge Insulation
BATH 3
8 ft
0
72 ft2
1
0
0
7 Slab -On -Grade Edge Insulation
BEDROOM 4
12 ft
0
168 ft2
__ 1
0
0
8 Slab -On -Grade Edge Insulation
CLST 4
2 ft
0
14 ft2
___ 1
0
0
9 Slab -On -Grade Edge Insulation
I
HALL 3
1 ft
0
40 ft2
__ 1
0
0
10SIab-On-Grade Edge Insulation
HALL 2
3 ft
0
28 ft2
___ 1
0
0
i 11SIab-On-Grade Edge Insulation
I
FAMILY
30 ft
0
224 ft2
___ 1
0
0
I 12SIab-On-Grade Edge Insulation
CAFE
16 ft
0
161 ft2
___ 1
0
0
13SIab-On-Grade Edge Insulation
KITCHEN
1 ft
0
192 ft2
___ 1
0
0
14SIab-On-Grade Edge Insulation
LAUNDRY RM
1 ft
0
44 ft2
1
0
0
IIII, 15SIab-On-Grade Edge Insulation
AHU
1 ft
0
12 ft2
___ 1
0
0
i
16SIab-On-Grade Edge Insulation
DINING
14 ft
0
156 ft2
___ 1
0
0
17SIab-On-Grade Edge Insulation
FOYER
8 ft
0
73 ft2
____ 1
0
0
18SIab-On-Gr2de Edge Insulation
i
M W IC 2
1 ft
0
56 ft2
1
0
0
19SIab-On-Grade Edge Insulation
MASTER BEDRO
36.6 ft
0
290 ft2
____ 1
0
0
20SIab-On-Grade Edge Insulation
M W IC 1
10 ft
0
64 ft2
1
0
0
21SIab-On-Grade Edge Insulation
MASTER BATH
35 ft
0
235 112
__-_ 1
0
0
22SIab-On-Grade Edge Insulation
i
M TOILET
lift
0
30 ft2
____ 1
0
0
` 23Slab-On-Grade Edge Insulation
LIVING ROOM
10 ft
0
197 ft2
----1
0
0
101311201711:59 AM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 7
FORM R405-2014
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type
Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Hip
Metal 2724 ft2
0 ft2
Light
0.6
No
0.9
No
20
26.6
ATTIC
1 V
#
Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Unvented
0
2436 ft2
N
N
II
I!
CEILING
1 V
#
Ceiling Type
Space
R-Value.
Ins Type
Area
Framing Frac Truss Type
I
1
Under Attic (Unvented)
BEDROOM 2
20
Blown
156ft2
0.1
Wood
2
Under Attic (Unvented)
CLST 2
20
Blown
18 ft2
0.1
Wood
j
3
Under Attic (Unvented)
BATH 2
20
Blown
45 ft2
0.1
Wood
i
4
Under Attic (Unvented)
CLST 3
20
Blown
18 ft2
0.1
Wood
jj
5
Under Attic (Unvented)
BEDROOM 3
20
Blown
143 ft2
0.1
Wood
6
Under Attic (Unvented)
BATH 3
20
Blown
72 ft2
0.1
Wood
I
7
Under Attic (Unvented)
BEDROOM 4
20
Blown
168 ft2
0.1
Wood
8
Under Attic (Unvented)
CLST 4
20
Blown
14 ft2
0.1
Wood
I
9
Under Attic (Unvented)
HALL 3
20
Blown
40 ft2
0.1
Wood
10
Under Attic (Unvented)
HALL 2
20
Blown
28 ft2
0.1
Wood
11
Under Attic (U nvented)
FAMILY
20
Blown
224ft2
0.1
Wood
�!
12
Under Attic (Unvented)
CAFE
20
Blown
161 ft2
0.1
Wood
13
Under Attic (U nvented)
KITCHEN
20
Blown
192ft2
0.1
Wood
i
14
Under Attic (Unvented)
LAUNDRY RM
20
Blown
44 ft2
0.1
Wood
l
15
Under Attic (Unvented)
AHU
20
Blown
12 ft2
0.1
Wood
16
Under Attic (Unvented)
DINING
20
Blown
156ft2
0.1
Wood
17
Under Attic (Unvented)
FOYER
20
Blown
73 ft2
0.1
Wood
18
Under Attic (Unvented)
M WIC 2
20
Blown
56 ft2
0.1
Wood
s
19
Under Attic (Unvented)
MASTER BEDRO 20
Blown
290 ft2
0.1
Wood
20
Under Attic (Unvented)
M WIC 1
20
Blown
64 ft2
0.1
Wood
21
Under Attic (Unvented)
MASTER BATH
20
Blown
235 ft2
0.1
Wood
22
Under Attic (Unvented)
M TOILET
20
Blown
30 ft2
0.1
Wood
' I
23
Under Attic (Unvented)
LIVING ROOM
20
Blown
197 ft2
0.1
Wood
I
WALLS
/
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar
Below
V22
C11111.
1 T i Pa
-P In
-
o
l _ 1
N
Exterior Concrete Block - Ext Ins1BEDROOM 2
4.1 12
0 10
0
120.0 ft2
0
0
0.6
0
2
N
S
Exterior Concrete 5lock - Ext InsLBEDROOM 2
4.1 12
0 10
0
120.0 ft2
0
0
0.6
0
" 3
-
W
Exterior Concrete Block - Ext Insd9EDROOM.2
4.1 13
0 10
0
130.0 ft2
0
0
0.6
0
- 4
S
Exterior Concrete Block - Ext Insul CLST 2
4.1 2
0, 10
0
20.0 ft2
0
0
0.6
0
- 5
S
Exterior Concrete Block - Ext Insul BATH 2
4.1 5
0' 10
0
50.0 ft2
0
0
0.6
0
- 6
S
Exterior Concrete Block - Ext Insul CLST 3
4.1 2
0 10
0
20.0 ft2
0
0
0.6
0
10/31/2017 11:59 AM EnergyGauga USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 7
FORM R405-2014
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar
Below
o
_ 7
S
Exterior
Concrete Block - Ext InstBEDROOM 3
4.1
11
0
10
0
110.0 ft2
0
0
0.6
0
8
S
Exterior
Concrete Block - Ext Insul BATH 3
4.1
8
0
10
0
80.0 ft2
0
0
0.6
0
_ 9
S
Exterior
Concrete Block - Ext InsSEDROOM 4
4.1
12
0
10
0
120.0 ftz
0
0
0.6
0
_ 10
S
Exterior
Concrete Block - Ext Insul CLST 4
4.1
2
0
10
0
20.0 ft2
0
.0
0.6
0
11
N
Exterior
Concrete Block - Ext Insul HALL 2
4.1
3
0
10
0
30.0 ft2
0
0
0.6
0
_ 12
N
Exterior
Concrete Block - Ext Insul FAMILY
4.1
14
0
11
0
164.0 ft2
0
0
0.6
0
_ 13
W
Exterior
Concrete Block - Ext Insul FAMILY
4.1
16
0
11
0
176.0 ft2
0
0
0.6
0
14
N
Exterior
Concrete Block - Ext Insul CAFE
4.1
11
0
14
0
154.0 ft2
0
0
0.6
0
_ 15
W
Exterior
Concrete Block -.Ext Insul CAFE
4:1
5
0
14
0
70.0 ft2
0
0
0.6
0
16
N
Exterior
Concrete Block - Ext Insul DINING
4.1
1
0
14
0
14.0 ft2
0
0
0.6
0
_ 17
E
Exterior
Concrete Block - Ext Insul DINING
4.1
13
0
14
0
182 0 ft2
0
0
0.6
0
_ 18
E
Exterior
Concrete Block - Ext Insul FOYER
4.1
8
0
14
0
112.0 ft2
0
0
0.6
0
_ 19
N
Exterior
Concrete Block - Ext InsLKIASTER BE
4.1
18
0
11
0
198.0 ft2
0
0
0.6
0
20
SW
Exterior
Concrete Block - Ext InsMASTER BE
4.1
8
7
11
0
94.4 ft2
0
0
0.6
0
_ 21
I
W
Exterior
Concrete Block - Ext InsiMASTER BE
4.1
10
0
11
0
110.0 ft2
0
0
0.6
0
22
N
Exterior
Concrete Block - Ext Insul M W IC 1
4.1
8
0
10
0
80.0 ft2
0
0
0.6
0
23
W
Exterior
Concrete Block - Ext Insul M W IC 1
4.1
2
0
10
0
20.0 ft2
0
0
0.6
0
24
N
Exterior
Concrete Block - Ext InstMASTER BA
4.1
9
0
10
0
90.0 ft2
0
0
0.6
0
25
E
Exterior
Concrete Block - Ext InsLMASTER BA
4.1
14
0
10
0
140:0 ft2
0
0
0.6
0
26
S
Exterior
Concrete Block - Ext InsdAASTER BA
4.1
12
0
10
0
120.0 ft2
0
0
0.6
0
li = 27
N
Exterior
Concrete Block - Ext InsulM TOILET
4.1
6
0
10
0
60.0 ft2
0
0
0.6
0
28
E
Exterior
Concrete Block - Ext InsulM TOILET
4.1
5
0
10
0
50.0 ft2
0
0
0.6
0
_ 29
W
Exterior
Concrete Block - Ext InsWIVING ROO
4.1
10
0
14
0
140.0 ft2
0.
0
0.6
0
i- 30
E
Garage
Frame - Wood LAUNDRY R
11
20
10
200.0 ft2
0
0 0.600000 0
-31
S
Garage
Frame -Wood DINING
11
8
10
80.0 ft2
0
0 0.600000 0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width,
Height
Area
Ft
in
Ft In
i
1
E
Insulated FOYER
None
A
6
8
48 ft2
'
WINDOWS
Orientation shown is the entered, Pro osed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
N 1
Metal Low-E Single Yes
0.65
0.25
15.0 ft2
2 ft 0 in
1 ft 4 In
None
None
2
W 3
Metal Low-E Single Yes
0.65
0.25
15.0 ft2
2 ft 0 in
1 ft 4 In
None
None
I
3
S 5
Metal Low-E Single Yes
0.65
0.25
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
4
S 7
Metal ' Low-E Single Yes
0.65
0.25
15.0 ft2
2 ft 0 in
1 ft 4 in
None
None
5
S 8
Metal Low-E Single Yes
0.65
0.25
6.0 ft2
2 ft 0 in
1 ft 4 in
None
None
6
S 9
Metal Low-E Single Yes
0.65
0.25
16.0 ft2
2 ft 0 in
1 ft 4 In
None
None
7
N 11
Metal Low-E Single Yes
0.65
0.2-
21.3 ft2
2 ft 0 in
1 ft 4 in
None
None
8
N 12
Metal Low-E Single Yes
0.65
0.3
72.0 ftz
2 ft 0 in
1 ft 4 In
None
None
9
W 13
Metal Low-E Single Yes
0.65
0.25
24.0 ft2
2 ft 0 in
1 ft 4 in
None
None
10/31/2017 11:59 AM , EnergyGauga USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 7
FORM R405-2014
WINDOWS
Orientation shown is the entered, Proposed orientation.
J
Wall
Overhang
#
Ornt
ID
Frame
Panes NFRC
U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
10
N
14
Metal
Low-E Single
Yes
0.65 0.25
20.0 ft'
2 ft 0 in
1 ft 4 in
None
None
11
W
15
Metal
Low-E Single
Yes
0.65 025
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
12
E
17
Metal
Low-E Single
Yes
0.65 0.25
30.0 ft'
2 ft 0 in
1 ft 4 in
None
None
j 13
N
19
Metal
Low-E Single
Yes
0.65 0.25
20.0 ft2
2 ft 0 in
1 ft 4 in
None
None
14
SW
20
Metal
Low-E Single
Yes
0.65 0.3
48.0 ft'
2 ft 0 in
1 ft 4 In
None
None
15
W
21
Metal
Low-E Single
Yes
0.65 0.25
20.0 ft2
2 ft0 in
1 ft 4 in
None
None
16
E.
25
Metal
Low-E Single
Yes
0.65 0.32
49.0 ft2
2 ft 0 in
1 ft 4 in
None
None
j 17
N
27
Metal
Low-E Single
Yes
0.65 0.25
9.0 ft2
2 ft 0 in
1 ft 4 in
None
None
18
i
W
29
Metal
Low-E Single
Yes
0.65 0.3
72.0 ft2
2 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
�i 1
400
ft2
384 ft'
28 ft
loft
11
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA
EgLA
ACH
ACH 50
i
1 Wholehouse
ProposedACH(50) .000511
3265.5 179.27
337.15
.3731
7
HEATING SYSTEM
••
1
-�...•.••. . yr�
Electric Strip Heat
..u...yw
None
unw--y �.aPac Ly
COP:1 27 kBtu/hr
DI[AAl
1
UULAb
sys#1
#
System Type
Subtype
COOLING SYSTEM
Efficiency Capacity Air Flow
SHR Block
Ducts
�f 1
Central Unit
Split
SEER: 16 42 kBtu/hr 1260 cfm
0.8 1
sys#1
HOT WATER SYSTEM
\ #
System Type SubType
Location
EF Cap Use SetPnt
Conservation
1
Electric None
Garage
0.98 50 gal 60.9 gal 120 deg
None
FSEC
Cert # Company Name
SOLAR HOT WATER SYSTEM
Collector
System Model /: Collector Model # Area
Storage.
Volume
FEF
None
None
ft2
10/31/2017 11:59 AM EnergyGauga USA - v5.1 - Section R405.4.1 Compliant Software Page 6 of 7
FORM R405-2014
DUCTS
/
-- Supply—
— Return —
Air
CFM 25
CFM25
HVAC #
V m
Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
?
Attic
6 175 ft2
Attic
18 ft'
Default Leakage
AHU
(Default) c(Default) c
1 1
I
TEMPERATURES
j Programable Thermostat: N
Ceiling Fans:
!1 Cooling Jan
i Heating an
Venting
Feb
Feb
Mar
�Cj Mar
f
Apr
Apr f
May
May
Jun Jul
Jun Jul
Auge
Aug
Sep
E
Oct
Oct f
Nov
X} Nov
Dec
Dec
H
i Jan
i
Feb
[[�Xl] Mar
(X7
A r [
Ma
Jun Jul
Au
Se
[Xl
Oct [X]
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
j Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
78
78
78 78
78
78
80
80
80
80
80
80
80
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
80
80
80
80
1
PM
80
80
80
80
78 78
78
78
78
78
78
78
i Heating (VdD)
68
68
PAM M
68
68
68
68
68
68
68
68
68
68
I Heating (WEH)
AM
65
65
65
65
65 65
65
68
68
68
68
68
p
PM
68
68
68
68
68 68
68
68
68
68
68
68
10/31/2017 11:59 AM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 7 of 7
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: MAY RESIDENCE Builder Name: GEM BUILDERS
Street: DYER ROAD Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned -with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers. shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawispace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to
available space shall extend behind piping and wiring.
Showerltub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots I
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
i vw uw: i i »:oa Am EnergyGauge® USA - v5.1 -Section R405.4.1 Compliant Software Page 1 of 1