HomeMy WebLinkAboutSEWAGE TREATMENT & DISPOSAL 8-22-185
4" STATE OF FLORIDA
DEPARTMENT OF HEALTH
s 'tfQ ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
. EIS
APPLICATION #:AP1317930
PERMIT #:!56-SF-1806718`
DOCUMENT #::F11203896
DATE PAID:.01/03/2018
FEE PAID.:80•00
---[ RECEIPT #:56-PIp-3460:670
APPLICANT: John & Kaylin May I 1 r Q
AGENT.: BIII Hyatt (Know it Now Inc)
PROPERTY ADDRESS: 2503 Dyer Rd Port Saint Lucie FL 34952
LOT: 6 BLOCK: 2
SUBDIVISION:
St. Lucie :Gardens ID#:
3414-501-1406400-2
CHECKED [X] ITEMS ARE NOT' IN .COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED,
TANK INSTALLATION
SETBACKS
[
] [01]
TANK SIZE [1] 1090.00 [21
[
] [27]
SURFACE WATER
FT
[
] [02]
TANK MATERIAL POlyothylehe
[
] [28.1
DITCHES
FT
[
] -[03]
OUTLET DEVICE
[
] [29]
PRIVATE WELLS 100
FT
[
] [041
MULTI_CHAMBERED [ Y N ]
[
] [301
PUBLIC WELLS
FT
[
] [05]
OUTLET FILTER Polylok PL-68
[
] [31]
IRRIGATION WELLS
FT
[
] [ 0 6]
LEGEND 1. 70-143-11 DC3 2.
[
] [ 32 ]
POTABLE WATER 60
FT
[
] [071
WATERTIGHT
[
] [33]
BUILDING FOUNDATIONS' 7
FT
[
] [081
LEVEL
[
] [34]
PROPERTY LINES 55
FT
[
] [09]
DEPTH TO LID
[
] [351
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[
] [101
AREA [1] 679.2 [2.]
SOFT [
] [361
DRAINFIELD COVER
[
] [11]
DISTRIBUTION BOX HEADER
X [
] [37]
SHOULDERS
[
] [121
'NUMBER OF DRAINLINES 1. 6.00 2.
[
] [381
SLOPES
[
] [13]
DRAINLINE SEPARATION
[
] [39]
STABILIZATION 08/2.2/2018
[
] [141
DRAINLI:NE SLOPE
[
] [15]
DEPTH OF COVER
ADDITIONAL INFORMATION.
[
] [16]
ELEVATION [ ABOVE / BELOW ]BM
0.0-0 [
]. [401
UNOBSTRUCTED AREA
[
] [171
SYSTEM LOCATION
[
] [411
STORMWATER RUNOFF
[
] [18]
DOSING PUMPS
[
] [42]
ALARMS
[
] [191
AGGREGATE SIZE
[
] [43]
MAINTENANCE AGREEMENT
[
] [201
AGGREGATE EXCESSIVE FINES
[
] [44]
'BUILDING AREA.
[
] [21]
AGGREGATE DEPTH
[
] [451
LOCATION CONFORM$ WITH :SITE PLAN
r
'] ['46]
FINAL SITE GRADING
FILL / EXCAVATION MATERIAL
[
]
[47]
CONTRACTOR MICHAEL W-STUHR (ASHTO
[ ]
[22]
FILL AMOUNT.
[
]
[48]
OTHER INFILTRATOR'Quick4 Plus'EQ36 LP
[ ]
[231
FILL TEXTURE
[ ]
[241
EXCAVATION DEPTH
ABANDONMENT
j ]
[25]
AREA REPLACED
[
]
[49]
TANK PUMPED
[ ]
[26-1
REPLACEMENT MATERIAL
[
]
[50]
TANK CRUSHED & FILLED'
Comments:
Comments are on page 2.
CONSTRUCTION [ APPROVED Fa R. St. Lucie. CHD DATE'.: 07/20/2018
DISAPPROVED. ° Environmenfal Specialist rian J Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED / DISAPPROVED 1: � %`^'"'� ' St.. Lucie CHD DATE: ''08/22/2018,
Environmental Specialist l DI nna S May' (Florida Department of: Health
(Explanation of Violations on. following -page)
DH 4016, 08/09 (Obsoletes all previous editions which may not.be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database. v 1.0.1 AP1317930 EID1806718
STATE OF FLORIDA
DEPARTMENT .OF HEALTH
ONSITE SEWAGE :TREATMENT. AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
• �u WE
Violation Number Comment
r ,nme-ta
APpticmioii' #j: AP131.7930
PERMIT
DocumENT #: F1120.3896
DATE PAID . 01 /0312018
FEE PAID:80M.
RECEIPT #;56'P.ID-346Q670
The system is sized for 4'bedrooms with a maximum -occupancy of i8 persons (2 per bedroom), for a total estimated flow of 40.0
3Pd. New ST, filter, and 6x1'0 long DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final
nspection for mound system and final site grading. Well inspected .at construction inspection.
Vo violations observed at final: inspection, Final approval etnailed. to.contractor and:building department..
DH 4o16, 0.8/09 (obsoletes all previous. editions which may not be used)
Incorporated: 64E-6.,003,.FAC Page 2..of 3
EH Database v 1.0.1 AP13179310 EID1806718