Loading...
HomeMy WebLinkAboutSEWAGE TREATMENT & DISPOSALSTATE OF FLORIDA APPLICATION # AP1317930 DEPARTMENT OF HEALTH PERMIT # 56-SF-1806718 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION DOCUMENT # SE1056239 APPLICANT: John & Kaylin May CONTRACTOR / AGENT: Know it Now, Inc LOT: 6 BLOCK: 2 SUBDIVISION: St. Lucie Gardens ID#: 3414-501-1406-100-2 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: (X]YES [ ]NO NET USABLE AREA AVAILABLE: 1.31 ACRES TOTAL ESTIMATED SEWAGE FLOW: 400 GALLONS PER DAY [ RESIDENCES-TABLEI / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 1965.01 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 1000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1000.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Site BM Orange survevors disk in road. Elevation 15.41 4.00 [ ELEVATION OF PROPOSED SYSTEM SITE / FT ] [ ABOVE /I BELOW I] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: 15 FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 100 FT NON -POTABLE: FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 40 FT POTABLE WATER LINES: 75 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X ]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD SOIL PROFILE INFORMATION SITE 1 SOIL PROFILE INFORMATION SITE 2 USDA SOIL SERIES:Waveland fine sand Munsell #/Color Texture Depth 1 OYR 411 Sand 0 To 11 1 OYR 5/1 Sand 11 To 25 1 OYR 6/1 Sand 19 To 33 1 OYR 211 Spodic Material 33 To 48 1 OYR 3/2 Sand 48 To 57 HOLE CAVING Refusal 57 To 72 USDA SOIL SERIES:Waveland fine sand Munsell #/Color Texture Depth 1 OYR 4/1 Sand 0 To 13 10YR 5/1 Sand 13 To 26 1OYR 611 Sand 21 To 35 10YR 211 Spodic Material 35 To 45 1OYR 3/2 Fine Sand' 45 To 57 HOLE CAVING Refusal 57 To 72 OBSERVED WATER TABLE: 26.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: ESTIMATED WET SEASON WATER TABLE ELEVATION: 20 INCHES ( ABOVE / BELOW ] HIGH WATER TABLE VEGETATION: [ ]YES [X]NO MOTTLING: [X]YES [ ]NO SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DRAINFIELD CONFIGURATION: [ ] TRENCH [XI BED r REMARKS/ADDITIONAL CRITERIA [ PERCHED / APPARENT ] EXISTING GRADE DEPTH: 20.00 INCHES Sand/0.60 DEPTH OF EXCAVATION: 48 INCHES [ ] OTHER (SPECIFY) VSWT determined using USDA WSS and soil borings. . OYR6/1 stripping in 10YR5/1 matrix > 10% with diffuse boundaries starting at 20" In SB1. 81 15" below BM. S6212" below BM. SITE EVALUATED BY: Ingram, Brian (Tine: Environmental Specialist II) (ENVIRONMENTAL HEALTH) DH 4015, 08109 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC DATE: 12/07/2017 G-t- A 4 File AP1317930 EID1806718 v 1.0.2 STATE OF FLORIDA PERMIT NO. I DEPARTMENT OF HEALTH DATE PAID: IZ F l 4r7 ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID: SYSTEM RECEIPT # : APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: [✓] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary [ ] APPLICANT: JOHN MAY AND KAYLIN MAY AGENT: BILL HYATT TELEPHONE: 772-925-2250 MAILING ADDRESS: 5220 US HIGHWAY 1, #140 VERO BEACH, FL 32967 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: 6 BLOCK: 2 SUBDIVISION: ST. LUCIE GARDENS PLATTED: Y PROPERTY ID #: 3414-501-1406-100-2 ZONING: AG-5 I/M OR EQUIVALENT: [ No ] PROPERTY SIZE: 1.31 ACRES WATER SUPPLY: [ ✓] PRIVATE PUBLIC [ ]<=2000GPD [ ]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ No ] DISTANCE TO SEWER: NA FT PROPERTY ADDRESS: XXXX DYER ROAD, PORT ST. LUCIE, FL 34952 DIRECTIONS TO PROPERTY: FROM US-1 AND DYER ROAD HEAD EAST 1.1 MILES +/-, THENCE HEAD EAST ON CARTLON ADAMS ROAD 0.57 MILES +/- TO DYER ROAD, THEN MEANDER .69 MILES +/- TO THE PROPERTY (LOCATED ON THE WEST SIDE OF ROAD) BUILDING INFORMATION Unit Type of No Establishment 1 PROPOSED RESIDENCE 2 3 4 [%/] RESIDENTIAL [ ] CObMRCIAL No. of Building Commercial/Institutional System Design Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 4 NA 2NIb [ ] Floor/Equipment Drains [ ] Other (Specify) SIGNATURE :�L/DATE DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated 64E-6.001, FAC Page 1 of 4 St. Lucie County Health Department 5150 NW Milner Dr Port Saint Lucie, FL 34983 PAYING ON: PERMIT #: 56-SF-1806718 BILL Doc #:56-BID-3637819 CONSTRUCTION APPLICATION #: AP1317930 RECEIVED FROM: Know it Now, Inc AMOUNT PAID: $ 515.00 PAYMENT FORM: CHECK 12370 PAYMENT DATE: 12/05/2017 MAIL TO: John & Kaylin May 060j g AAA-9`1 tJ Slnc� C.� W r�7 FACILITY NAME.: PROPERTY LOCATION: TBD Dyer Rd Port Saint Lucie, FL 34952 Lot: 6 Block: 2 Property ID: 3414-501-1406-100-2 EXPLANATION or DESCRIPTION: QUANTITY FEE 128 - OSTDS Construction System Inspection Research Fee 1 $ 5.00 -1 - Surcharge (All) 1 $ 15.00 -1 - OSTDS New Permit Surcharge 1 $ 100.00 -1 - OSTDS Construction Application and Plan Review,New 1 $ 100.00 123 - OSTDS Construction Site Evaluation 1 $ 115.00 126 - OSTDS Construction Permit (New or Mod, Amendment) 1 $ 55.00 127 - OSTDS Construction System Inspection 1 $ 75.00 133 - OSTDS Construction Reinspection 1 $ 50.00 RECEIVED BY: VanceMH AUDIT CONTROL NO. 56-PID-3446587 :....:.,.. ,: St. Lucie County Health Department u 5150 NW Milner Dr Port Saint Lucie, FL 34983 HEALTH PAYING ON: PERMIT#:56-SF-1806718 1311-Looc#:56-BID-3650027 CONSTRUCTION APPLICATION #: AP1 317930 RECEIVED FROM: Know it Now, Inc AMOUNT PAID: $ 80.00 PAYMENT FORM: CREDIT CARD PAYMENT DATE: 01/03/2018 MAIL TO: John & Kaylin May FACILITY NAME: PROPERTY LOCATION: TBD Dyer Rd Port Saint Lucie, FL 34952 Lot: i Property ID: 3414-501-1406-100-2 EXPLANATION or DESCRIPTION: -1 - OSTDS Revision 2 Block: 126 - OSTDS Construction Permit (New or Mod, Amendment) QUANTITY FEE 1 $ 25.00 1 $ 55.00 RECEIVED BY: VanceMH AUDIT CONTROL NO. 56-PID-3460670 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120,569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a'final order'. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT SYSTEM CONSTRUCTION PERMIT FOR: OSTDS New AND DISPOSAL APPLICANT: John & Kaylin May PROPERTY ADDRESS: TBD Dyer Rd Port Saint Lucie, FL 34952 LOT: 6 BLOCK: 2 PROPERTY ID #: 3414-501-1406-100-2 SUBDIVISION: St. Lucie Gardens PERMIT #:56-SF-1806718 APPLICATION #:AP1317930 DATE PAID: FEE PAID: RECEIPT #: DOCUMENT #: PR1084981 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T ( 1,050 ] GALLONS / GPD Septic New CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ ] D [ 667 ] SQUARE FEET R [ ] SQUARE FEET A TYPE SYSTEM: [ ] I CONFIGURATION: [ ] N F LOCATION OF BENCHMARK: Drainfield New SYSTEM N/A SYSTEM STANDARD [ ] FILLED DQ MOUND [ ] TRENCH [XI BED [ ] Site BM - disk in road. Elevation 15.41 I ELEVATION OF PROPOSED SYSTEM SITE [ 4.00 ][INCHES FT ][ABOVE BELOW BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 0.00 ][ INCBES FT ][ABOVE BELOW] BENCHMARK/REFERENCE POINT L D ] 0 T H E R %L" Mf2waimu: L LL.UU] INCHES EXCAVATION REQUIRED: [ 48.UU ]. INCHES The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with s. 64E-6.013(3)(0, FAC. Original permit modified to reference the site benchmark not available at time of initial site evaluation. SPECIFICATIONS BY: Brian J Ingram TITLE: Environmental Specialist II APPROVED BY: � "-"r /�Ni TITLE: Environmental Specialist I St. Lucie CHD Dianna S M DATE ISSUED: 01/03/2018 DR 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, PAC v 1.1.4 AP1317930 EXPIRATION DATE: 06/07/2019 SE1056239 Page 1 of 3 1