Loading...
HomeMy WebLinkAboutPROJECT INFORMATION�... Right J@ Mobile Report RECEIVED JuD Dale: 7/12/2018 By JUL 13 2018 � r ,SM,�gcle_QuntY, Permitting Project,• • For: Whigham 5802 Hickory Drive Fort Pierce, FL 34982 (Rear Addition) r ®e• • • • Location: Indoor: Heating Coo ing St Lucie Co nt , FL, US ndoor temperature (°F) 70 75 E evation: 26 ft Design TD (°F) 29 15 Latitude: 28 °N Re ative humidity (%} 30 50 Outdoor: Heating Coo ing Moisture difference (gr/ b) 24 569 Drybu b (°F) 41 90 Infi tration: Dai yrange (°F) 15 (I. ) Method Simp ified Wetbu b (°F) 77 Construction qua ity Average Wind speed (mph) 150 75 Firep aces 0 l Component Btuh/ft' Btuh % of load Walls 2.6 3659 30.9 Glazing 16.5 2617 22.1 Doors 11.3 238 2.0 Ceilings 1.4 1222 10.3 Floors 2.3 1945 16.4 Infiltration 1.4 2158 18.2 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 1 11839 100.0 Component Btuh/ft2 Btuh % of load Walls 1.3 1868 13.2 Glazing 41.1 6501 45.9 Doors 11.4 240 1.7 Ceilings 2.6 2225 15.7 Floors 1.0 859 6.1 Infiltration 0.4 586 4.1 Ducts 0 0 Ventilation 0 0 Internal gains 1890 13.3 Blower 0 0 Adjustments 0 Tota 1 14167 100.0 Latent Coo ing Load = 1937 Btuh Overa U va ue = 0 102 Btuh/ftz 'F Data entries checked vwe ightmafR- �'� --• ---- Right Suite0 oniversa 201818 020 Right J® Mobia lwstmp169e6c252 1a71 406d a011 eb9b5ec15fe6 rup Ca c = MJ8 Front Door faces: N Ifiltr�ia� MIS Flans Gajrg D� 7irgs V1JIs Intend Coins Infiltration Roos Calirxls aaar 2018 Ju 12 11.24:29 s I ._JUD AL Project Summary For: ;Proi'ect In#ormatiort. 5802 Hickory Drive, Fort Pierce, FL 34982 Deli n' inform ti , Weather: St Lucie Co nt , FL, US Winter Design Conditions Outside db 41 °F nside db 70 T Design TD 29 T Heating Summary Structure 11839 Btuh Ducts 0 Btuh Centra vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment oad 11839 Btuh Infiltration Method Construction qua ity Firep aces Simp ified Average 0 Heating Coo g Area (ft') 1003 100in3 Vo ume (ft') 9027 9027 Air changes/hour 045 023 Equiv AVF (cfm) 68 35 Heating Equipment Summary Job: Date: 7/12/2018 By: Summer Design Conditions Outside db 90 °F nside db 75 °F Design TD 15 T Dai y range L Re ative humidity 50 % Moisture difference 57 gr/ b Sensible Cooling Equipment Load Sizing Structure 14167 Btuh Ducts 0 Btuh Centra vent (0 cfm) 0 Btuh (none) B ower 0 Btuh Use manufacturer's data y Rate/swing mu tip ier 1 00 Equipment sensib a oad 14167 Btuh Latent Cooling Equipment Load Sizing Structure 1937 Btuh Ducts 0 Btuh Centra vent (0 cfm) 0 Btuh (none) Equipment atent oad 1937 Btuh Equipment Tota Load (Sen+Lat) 16105 Btuh Req tota capacity at 0 70 SHR 1 7 ton Cooling Equipment Summary Make n/a Make Trade n/a Trade Mode n/a Cond AHR ref n/a Coi AHR ref ' Efficiency n/a Efficiency 0 SEER Heating input 0 Btuh Sensib e coo ing 0 Btuh Heating output 0 Btuh Latent coo ing 0 Btuh Temperature rise 0 °F Tota cooing 0 Btuh Actua air f ow 645 cfm Actua air f ow 645 cfm Air f ow factor 0 054 cfm/Btuh Air f ow factor 0 045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensib a heat ratio 088 N • Bold/italic values have been manually overridden Ca cu ations approved by ACCA to meet a requirements of Manua J 8th Ed 1 lfe/B•1ga1C�®¢�-- �-•- —. Right Suite®Universa 2018 18 0 20 Right JO Mobie 2018 Ju 12 11:24:29 ,6& kvvs1mpt69e6c252 la71 406d a011 eb9b5ec15fe6 rup Car, = NUB Front Door faces: N Right-JO Worksheet Job: Date: 7/1212018 By: 1 Room name Entire House First F oor 2 Exposed wa 174 O ft 58 O ft 3 Room height 90 ft d 90 ft heat/coo 4 Room dimensions 11 0 x 180 ft 5 Room area 1003 0 f t2 1980 f t' Ty Construction U va ue or HTM Area (w) Load I Area (ft.) I I Loaa j number (Btuhift, .F) (Bt-MV) or perimeter (ft) (Btuh) or perimeter (ft) I (Btuh) Heat Co. Gross N/PIS Heat Coo Gross N/P/S Heat Coo 6 V)I L 12C-Obw 0.091 n 2.64 1.35 414 372 983 501 99 89 235 120 1 D-c2ow 0.570 n 16.53 20.52 42 0 689 855 10 0 165 205 —G Vv L—G 12C Obw 0 091 e 2 64 135 369 332 875 446 162 145 384 196 1 D c2ow 0 570 e 1653 6259 38 0 620 2347 17 0 276 1043 Vl—G 11 12C-Obw 0.091 s 2.64 1.35 414 372 983 601 99 89 235 120 1D-c2ow 0.570 s 16.53 22.84 42 0 689 951 10 0 165 228 ✓ 12C Obw 0 091 w 264 1 35 369 311 819 418 162 124 328 167 1D c2ow 0 570 w 1653 6259 38 D 620 2347 17 0 276 1043 11D0 0 390 w 11 31 1143 21 21 238 240 21 21 238 240 C 16B-19ad 0.049 1.42 2.59 850 860 1222 2225 55 55 78 142 F 20P 11t 0 078 2 26 1 00 198 198 448 198 198 198 448 198 F 20P-11 t 0.078 2.26 1.00 662 662 1497 661 0 0 0 0 6 c) AED excursion 01 1 0 Enve ope oss/gain 1 9682 11692 1 1 2827 3703 12 a) nfi tration 215B 586 719 195 b) Room venti ation 0 0 0 0 13 nterna gains: Occupants @ 230 3 690 3 590 App iances/other 1200 1200 Subtota ( ines 6 to 13) 11839 14167 3546 5788 Less externa oad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtola 11839 14167 3546 5788 15 Duct Dads 0% 0% 0 0 0% 0% 0 0 Tota room oad I li8391 141671 31461 5788 Air required (cfm) I ` I 645 645 193 263 Ca cu ations approved by ACCA to meet a requirements of Manua J 8th Ed wi�Igtalrso8t- .�A. --�-• -•-�—•--- Right SuileOUniversa 2018 ?8 0 20 Right JOMobie 2018 Ju 12 11:24:29 lwstmpt69e6c252 1 a71 406d a011 eb9b5ec15fe6 rup Ca c = MJS Front Door faces: N night-J@ Worksheet Job: Date: 711=018 By: 1 Room name Second F oor 2 Exposed we 1160 ft 3 Room height 90 ft heat/coo 4 Room dimensions 35 0 x 230 ft 5 Room area 805 0 f t2 Ty Construction Uvaue Or HTM I i Area (ft') Load I Area Load number (Btuhlft2 °F) (Btuh/W) I or perimeter (ft) (Biuh) of perimeter Heat Coo Gross NIP/S Heat Coo Gross N/PIS Heat Coo 6 W 12C-Obw 0.091 n 2.64 1.35 315 283 748 382 �G 1D-c2ow 0.570 n 16.53 20.52 32 0 523 650 vt/ mil"• 12C Obw 0 091 e 264 135 207 186 491 251 1 D c2ow 0 570 a 16 53 6259 21 0 344 1304 C 11 12C-Obw 0.091 s 2.64 1.35 315 283 748 362 1D-c2ow 0.570 s 16.53 22.84 32 0 523 723 Vy 12C Obw 0 091 w 2 64 1 35 207 186 491 251 1 D c2ow 0 570 w 16 53 6259 21 0 344 1304 11 DO 0 390 w 11 31 1143 0 0 0 0 C 16B-19ad 0.049 - 1.42 2.59 805 805 1144 2083 F 20P 11 t 0 078 226 100 0 0 0 0 F 20P-11t 0.078 2.26 1.00 662 662 1497 661 6 c) AED excursion 0 Enve ope oss/gain 6855 7989 12 a) nfi tration 1438 390 b) Room vend ation 0 0 13 nterna gains: Occupants @ 230 0 0 Appiances/other 0 Subtota ( ines 6 to 13) 8293 8379 Less externa oad 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtota 8293 8379 15 Duct oads 0% 0% 0 0 8452I 8381 3791 I II Air requomd (cdn) I I Ca cu ations approved by ACCA to meet a 'requirements of Manua J 8th Ed y -rid- 2018 Ju 1211:24:29 .�7i. ••••�-•—^•�• Right Suited Universe 2018 18 0 20 Right JO Mobi e \wstmp\69e6c252 1.71 406d a011 eb9b5ecl5fe6 rup Ca c = MJ8 Front Door faces: N HL For: 5802 Hickory Drive, Fort Pierce, FL 34982 Job: Date: 7/12/2018 By: Location: Indoor: Heating Coo ing St Lucie Co nt , FL, US ndoor temperature (T) 70 75 E evation: 26 ft Design TD (T) 29 15 Latitude: 28'N Re ative humidity (%) 30 50 Outdoor: Heating Coo ing Moisture difference (gr/ b) 24 569 Drybu b (T) 41 90 Infi tration: Dai yrange (T) 15 ( L ) Method Simp ified Wet bu b (T) 77 Construction qua ity Average Wind speed (mph) 150 75 Firep aces 0 Construction descriptions Or Area U va ue nsu R Htg HTM Loss C g HTM Gain ft, Btuh/ft"F ft' 'F/Btuh Bluh/W Btuh BMW Btuh Wa s 12C Obw: Frm wa , brk 4" ext, r 13 cav ins, 1/2" gypsum board int n 372 0 091 130 264 983 1 35 501 fnsh, 2"x4" wood frm, 16" o c stud e 332 0 091 130 264 875 1 35 446 s 372 0 091 130 264 983 1 35 501 w 311 0091 130 264 819 135 418 { a 1387 0 091 130 264 3659 1 35 1868 Partitions (none) Windows 1 D c2ow: 2 g azing, c r outr, air gas, wd frm mat, c r innr, 1/4" gap 1/8" thk; 6 67 ft head ht Doors 11 DO: Door, wd sc type Cei ings 16B 19ad: Attic cei ing, aspha t shing es roof mat, r-19 cei ins, 1/2" gypsum board int fnsh F oors • 20P 11 t: F r f oor, wd f r, 1" thkns, ti e f r fnsh, r-11 ext ins, amb ovr n 42 ' 0 570 0 165 689 205 855 e 38 0 570 0 165 620 626 2347 s 42 0 570 0 165 689 228 951 w 38 0 570 0 165 620 626 2347 a 158 0 570 0 165 2617 41 1 6501 w 21 0 390 0 11 3 238 114 240 860 0 049 190 1 42 1222 259 2225 198 0 078 11 0 226 448 1 OD 198 662 0 07B 11 0 226 1497 1 00 661 a 860 0 07B 11 0 226 1945 1 00 859 t wrights®f - 2018 Ju 12 11:24:30 Right Suite@ Universa 2018 18 0 20 Right JO Mobie 'ACC;N lwstmp169e6c252 1a71 406d a0l l eb9b5ec15fe6 rup Ca c = MJ8 Front Door faces: N I