Loading...
HomeMy WebLinkAboutREPORT OF FOUNDATION PAD COMPACTIONEAMT�,;P -' A. M. ENGINEERING ANL,ZSTING, INC. 3504 INDUSTRIAL 33RDSTREET v `� FT. PIERCE, FLORIDA 349461 :.v -y LOCAL OFFICE: (772) 461-7508 FAX: (77 1-8880 2006 REPORT OF FOUNDATION PAD COMPACTION Client: Richard Jones Construction Report Date: 12/20/05 Project No: Report No: 7829 Site: 9329 Scarborough Court, Lot 21 Permit No: St. Lucie County, Florida Foundation Pad Density tests and Hand Cone Penetrometer (HCP) readings were made at a minimum of three locations in the building pad. Density tests were performed in the upper one foot of fill. HCP readings were taken in hand auger boreholes at one foot intervals from slab grade through the depth of fill. The density tests were performed in general compliance with ASTM D 2922. The HCP test, in conjunction with information about the soil type, is empirically correlated to the relative density of subsurface soils. Density Test No. Date Tested Location Elevation (feet) Dry Densi (cf) Percent Compaction In Place Proctor 7829 12/19/05 NE Corner 0-1 111.0 114.0 97.4 Center 0-1 112.1 114.0 98.3 SW Comer 0-1 109.3 114.0: 95.9 * All elevations are below slab grade. The depth of the fill was approximately one to three feet. The fill should extend at least five feet beyond the building perimeter. At the time of our testing no information was available regarding the foundation pad setbacks. 4 In the locations and depths that Were tested, the •fill has been compacted to a minimum of 95 percent of the modified Proctor maximum dry'density (ASTM D 1557). No soil borings were performed below the recently placed fill. Distribution: Client — 1 Client (Fax) 466-6572 Submitted by: A. M. ENGINEERING AND TESTING, INC. V Richard $ovette, P.E: � ,V Florida Registration No. 42485 S. IF&t Pierce OfceWetAppsVTTLE LOG BOOKWouse JobsUflsc. House JobslSaint Lucie CounryUonesRichard(7829)9329 Scarborough Cf., Lot 2f.doc, SG