Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL WINDOW HORIZONTAL SLIDERComments Archived Product Manufacturer OT ndustrie'' Address/Phone/Email 1070 Technology Drive North Venice, FL 34275 (941)486-0100 Ext22318 druark@pgtindustries.com Authorized Signature Jens Rosowski jrosowski@pgtindustries.com Technical Representative Jens Rosowski Address/Phone/Email 1070 Technology Drive Nokomis, FL 34275 (941)486-0100 Ext21140 jrosowski@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By �2'5 E 1. s 0 �ye• t N:� �i;.iiiiM� C •.f'., �.% 0 izontal-Slider;-_�---- Certification Mark or Listing Miami -Dade BCCO - CER Miami -Dade BCCO - VAL Standard TAS 201, 202, 203 Product Approval Method Method 1 Option A • Date Submitted 09/07/2016 Date Validated 10/17/2016 e Date Pending FBC Approval Year 1994 Date Approved Date Revised Summary of Prod 10/17/2016 09/25/2017 FL # Model, Number or Name 2421 H�1-0'(NiIinpa'ct) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Please see the Miami -Dade County Notice of Acceptance (NOA) for product performance information, anchorage details, and anchor type, size, and spacing information. Description Aluminum Horizontal Roller Window Certification Agency Certificate FL242 R21 C CAC 16-0629.02.pdf Quality Assurance Contract Expiration Date 04/05/2022 Installation Instructions FL242 R21 II 16-0629.02.pdf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.2 HR - 510 (Impact) WinGuard Vinyl Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 15-0612.14.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 02/17/2021 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 II 15-0612.14.pdf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.3 HR - 610 (Non -Impact) WinGuard Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 16-0714,14.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/27/2021 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 11 16-0714.14.pdf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.4 HR - 710 (Impact) WinGuard Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 16-0714.13.ndf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/21/2021 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 II 16-0714,13.pdf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.5 HR - 810 (Large Missile Impact) Multi -Story Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 16-0714.10.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 11/O1/2017 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 II 16-0714.10.pdf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.6 HR - 810 (Small Missile Impact) Multi -Story Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 16-0714.15.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 11/01/2017 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 II 16-0714.15.odf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.7 1 HR-2710M (Impact) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Please see the Miami -Dade County Notice of Acceptance (NOA) for product performance information, anchorage details, and anchor type, size, and spacing information. (2-lite XX only) 2LT HR-2710M PVC Horizontal Rolling Window Certification Agency Certificate FL242 R21 C CAC 15-0528.23 M.Ddf Quality Assurance Contract Expiration Date 12/23/2020 Installation Instructions FL242 R21 II 15-0528.23 M.Ddf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 242.8 HR-2710MI (Impact) 2/3 LT HR2710MI PVC HORIZONTAL ROLLER LMI Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 13-1125.03 MI.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/23/2020 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 II 13-1125.03 MI.pdf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. (2-lite XX & 3-lite XOX) Evaluation Reports Created by Independent Third Party: 242.9 HR-5410 (Non -Impact) Vinyl Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 16-0714.18.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 09/24/2020 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 11 16-0714.18.Ddf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.10 HR-5510 (Impact) Vinyl Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 16-0714.17.pcif Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 09/24/2020 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 II 16-0714.17.Ddf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.11 SGD - 770 Window (Impact) Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 16-0629.09 pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 02/12/2020 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 II 16-0629.09.12df Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.12 SGD-2500 Window (Non -Impact) Aluminum Horizontal Roller Window Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL242 R21 C CAC 15-0609.09 WDW.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/22/2018 Design Pressure: N/A Installation Instructions Other: Please see the Miami -Dade County Notice of FL242 R21 II 15-0609.09 WDW.odf Acceptance (NOA) for product performance information, Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: 242.13 1 SGD-5570 Window (Impact) Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Vinyl Horizontal Roller Window Certification Agency Certificate FL242 R21 C CAC 16-0505.Ol.odf Quality Assurance Contract Expiration Date 08/04/2021 Installation Instructions Other: Please see the Miami -Dade County Notice of Acceptance (NOA) for product performance information, FL242 R21 II 16-0505.0l.gdf Verified By: Miami -Dade BCCO - CER anchorage details, and anchor type, size, and spacing Created by Independent Third Party: information. Evaluation Reports Created by Independent Third Party: Back tdext Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here_. Product Approval Accepts: Crediti Safe securitym RrRici MIAMI•DADE MLA M-DADS COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) wrvw.miamidade.gov/economy PGT Industries, Inc. 1070 Technology Drive LLE North Venice, FL 34275 SCOPE: COPY This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami —Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. - DESCRIPTION: Series 11HR-210" Aluminum Horizontal Rolling Window - N.I. APPROVAL DOCUMENT: Drawing No. MD-IIR210-01 titled "Horizontal Roller Window Details", sheets 1 through 8 of 8, dated 12/01/11, with revision B dated 05105115, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E., bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: None. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, ' and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises and renews NOA# 15-0609.05 and consists of this page 1 and evidence pages E-1 and E-2, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. NOA No. 16-0629.02 Expiration Date: April 05, 2022 Approval Date: August 04, 2016 cP J Page 1 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No.11-1201.04) 2. Drawing No. MD-HR210-01 titled "Horizontal Roller Window Details", sheets 1 through 8 of 8, dated 12/01/11, with revision B dated 05105115, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 along with marked -up drawings and installation diagram of a PVC sliding glass door, a PVC fixed window and an aluminum sliding glass door, using: Kodispace 4SG TPS spacer system, Durasealo spacer system, Super Spacer® NXTTM spacer system and XL EdgeTM spacer system at insulated glass, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-8717, FTL-8968 and FTL-8970, dated 11116115, 06/07/16 and 06/02/16 respectively, all signed and sealed by Idalmis Ortega, P.E. 2. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Forced Entry Test, per FBC 2411.3.2.1, and TAS 202-94 along with marked -up drawings and installation diagram of an aluminum horizontal sliding window, prepared by Fenestration Testing Laboratory, Inc., Test Reports No. FTL-6657 and FTL-6658, dated 10/17/11 and 10/18/11 respectively, and addendum letters for each dated 03/22/12, all signed and sealed by Marlin D. Brinson, P.E. (Submitted under NOA No.11-1201.04) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC-5th Edition (2014), dated 05/29/15, prepared by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under previous NOA No. 15-0609.05) 2. Glazing complies with ASTM E1300-04 D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. None. E-1 Manuel P ez, P.E. Product Contro E aminer NOA No. 0629.02 Expiration Date: April 05, 2022 Approval Date: August 04, 2016 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, complying with FBC-2010 and FBC-5' Edition (2014), dated May 26, 2015, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted underprevious NOA No. 15-0609. 05) 2. Statement letter of no financial interest, dated May 26, 2015, issued by manufacturer, signed and sealed by Anthony Lynn Miller, P.E. (Submitted under previous NOA No.15-0609.05) 3. Laboratory compliance letter for Test Reports No. FTL-6657 and FTL-6658, issued by Fenestration Testing Laboratory, Inc., dated 10/17/11 and 10/18/11 respectively, both signed and sealed by Marlin D. Brinson, P.E. (Submitted under NOA No. 11 -12 01.04) 4. Proposal No.16-0125 issued by the Product Control Section, dated March 09, 2016, signed by Ishaq Chanda, P.E. G. OTHERS 1. Notice of Acceptance No. 15-0609.05, issued to PGT Industries, Inc. for their Series "HR-210" Aluminum Horizontal Sliding Window - N.I., approved on 08/13/15 and expiring on 04/05/17. Manuel Pere r.E. Product Control Exdohner NOA No, 16-0629.02 Expiration Date: April 05, 2022 Approval Date: August 04, 2016 E-2 GENERAL NOTES: SERIES 210 NON -IMPACT HORIZONTAL ROLLER WINDOW 1) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2) SHUTTERS ARE REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. 3) FOR MASONRY APPLICATIONS IN MIAMI-DADE COUNTY, USE ONLY MIAMI-DADS COUNTY APPROVED MASONRY ANCHORS, MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN. KSI PER ANCHOR TYPE, SEE TABLE 1, SHEET 1. 4) ALL WOOD BUCKS LESS THAN 1-1/2'THICK ARE TO BE CONSIDERED 1X INSTALLATIONS. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLYTO SUBSTRATE. WOOD BUCKS DEPICTED AS 2X ARE 1-1/2' THICK OR GREATER. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE. WOOD BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD. 5) ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO. USE ANCHORS OF SUFFICIENT EMBEDMENT AS SPECIFIED ON TABLE 1, SHEET 1. NARROW JOINT SEALANT IS USED ON ALL FOUR CORNERS OF THE FRAME. INSTALLATION ANCHORS SHOULD BE SEALED. OVERALL SEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. 6) SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE - PRODUCT IS NOT FLUSH TO THE SUBSTRATE USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. SHIM TO BE NO MORE THAN 1/4' THICK. WOOD BUCKS, BY OTHERS, MUST BE SUFFICIENTLY ANCHORED TO RESIST LOADS IMPOSED ON THEM BY THE WINDOW. 7) DESIGN PRESSURES: A) NEGATIVE DESIGN LOADS BASED ON STRUCTURAL TEST 7 PRESSURE, FRAME ANALYSIS AND GLASS PER ASTM E1300. HE[ B) POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE. STRUCTURAL TEST PRESSURE, FRAME ANALYSIS AND GLASS PER ASTM E1300. 8) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDING TO THE REQUIRED DESIGN PRESSURE. THE 33 113%STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD. ANCHORS THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. - 9) REFERENCES: TEST REPORTS FTL-6657 & 6658; ELCO ULTRACON NOA; ELCO CRETEFLEX NOA; ANSVAFSPA NDS FOR WOOD CONSTRUCTION AND ADM ALUMINUM DESIGN MANUAL. 10) THE 210 SERIES HORIZONTAL ROLLER WINDOW WAS FORMERLY KNOWN AS THE 201 SERIES. DESIGN PRESSURE RATING IMPACT RATING VARIES, SEE SHEETS 3 & 4 NOT RATED FOR IMPACT RESISTANCE STANDARDS USED: •2014 FLORIDA BUILDING CODE (FBC), 5TH EDITION - ASTM E1300-04 •ANSI/AF&PA NDS-2012 FOR WOOD CONSTRUCTION •ALUMINUM DESIGN MANUAL, ADM-2010 • AI S I-S 100-07/S2-2010 120• WIDTH A 63' HEIGHT 62' BUCK HEIGHT I t A SHEETS 5&6 ALWAYS SEE NOTE A. SEE NOTES B & C. B 1I 3'y16' REQUIRED THIS SHEET THIS SHEET I'� 3' @ CORNERS TYP. XOX (1/4-1/2-1/4) ELEVATION ��y aV••a ,n��n JB SHEETS 586 58-1/8• —_—_L—_ SASH VISIBLE FIXED VISIBLE LIGHT "��// LIGHT i 28-9/18' SASH VISIBLE 56.3116" FIXED VISIBLE LIGHT LIGHT I 74' WIDTH 73' BUCK WIDTH B SHEETS 586 QL 2' 3HTT1' BUCK HEIGHT I 67-1/8' FIXED VISIBLE LIGHT FIXED VISIBLE ILIGHT PCSHEETS 586 TABLE 1: 6 HEI 90•WIDTH 89' BUCK WIDTH 6 I—�B SHEETS I 5& - --- I 283/B' I --- FIXED q SIBLE LIGHT 3' 3HT 62" 56-7/8" SASH VISIBLE LIGHT VVV 58-1/8" FIXED VISIBLE LIGHT- A BUCK HEIGHT 26-7116" SASH VISIBLE LIGHT i PA SHEETS 5&6 ALWAYS SEE NOTE A, .I- �BI �� —�I'�— 33116• REQUIRED THIS SHEET --_d 3' @ CORNERS SEE NOTES B & C. THIS SHEET TYP. XOX (1/3-1/3-1/3) ELEVATION Anchor Group Anchor Substrate Min. Edge Distance Min. Embedment A 1Steel Uli Ultracon Hollow Block, (ASTM C90) 2-1/2• 1-1/4• - 'ftf2 Steel` SMS (G5) a C12 410 SS___ SMS P.T. Southern Pine (SG = .55) 9/16" 1-3/8• A36 Steel, .125" min 318" Min. of 3 threads beyond metal substrate _A653 Stud, _Gr-33 0,0340"-min: (20,Ga) 318" ,- lglilminurn; 6063-75, r125"•min---F 318" 1/4' Steel Ullmctxl `-'^--' Concrete (min. 2.9 ksi) 1" 1-3/8' Grouted -filled Block, (ASTM C90) 2-1/2' 1-3/4' L 114" 410 SS CreteFlex Concrete (min. 3.4 ksi) 1" 1-3/4' Ftdlow Block. (ASTM ('I 1-a 1-1/4' ALWAYS &' —�I I` L`B --�-r �- 3-3/16" REQUIRED SEE NOTE D. THIS SHEET @ CORNEA.-. TYP`XO-ELEVATI.QN'(OX4SII1? lltltlrlrl/,,, '­ CMI LYAIA, ELEVATIONS ........... .................... ._ 1 ANCHOR SPECIFICATIONS._......... 1 ANCHOR SPACING/QUANTITIES... 2 DESIGN PRESSURES, XO/OX......_ 3 DESIGN PRESSURES, XOX...._._._ 4 INSTALLATION, STD MR ............ _._ 5 INSTALLATION, HO MR .. ............... _ 0 GLAZING DETAILS ...................... ... 7 CORNER ASSEMBLY ...................... 7 EXTRUSION PROFILES ...... .......... 8 PARTS LIST.._ .................. ........ .... 8 ~�• ••1.ICENS. •-�/� lltr No.58705 •.13 •, p F s A LYNN MILLER RE P.EJf 58705 WEEPHOLE NOTES. (SEE WEEPHOLE DETAILS. SHEET 7 OF 8): A. REQUIRED IF WINDOW WIDTH IS OVER 67'. B. REOU RED F WINDOW WIDTH S OVER 45' AND UP TO 67". C. REQUIRED IF WINDOW WIDTH IS OVER 89". D. REQU RED IF WINDOW WIDTH IS OVER 45". Revised 9y: Drt•: Revielon: JR 05/05/16 B) ADDED SPACERS TO SHEET 8. Revised W. Date: Revision: ® Dwerfptfon: GENERAL NOTES & ELEVATION PRODUCT REVISED w conrylying with dw Florida ;� � i6-oGrLq.p2 P 2 'moan Date MB iarnl Pr Om4al J ROSOWSKI 1070 TECHNOLOGY DRIVE Rtle: tHIlc. N. VENICE, Fl. 34275 HORIZONTAL ROLLER WINDOW DETAILS 12/01/11 P.O. BOX 1529 NOKOMIS: FL 34274 Sarim/Nodeh Scab: Sheet Drawing No. R• CFRT. OF AUTH. #29296 HR-210 NTS 1 OF 8 MD-HR210-01 1 ANCHOR ON 1 ANCHOR AT EACH SIDE OF CORNER THE MEETING RAIL MIN.3 ANCHORS IN JAMB FOR WINDOWS UP TO 44'. MIN, 4 ANCHORS IN JAMB FOR WINDOWS OVER 44' 1 ANCHOR AT CORNER 6' MAX. SEE TABLE 2, 1 ANCHOR ON THIS SHEET, FOR 1 ANCHOR ON EACH SIDE OF ANCHOR EACH SIDE OF 1 ANCHOR AT QUANTITIES' 1 ANCHOR AT CORNER THE MEETING THE MEETING CORNER 1 RAn —_---- RAn MI ANCHORS IN JAMB FOR 17' MAX. O.C. FOR WINDOWS UP WINDOWS UP T063' TO 44', MINA TALL, 20' MAX. O.C. ANCHORS IN FOR WINDOWS OVER 63' JAMB FOR WINDOWS OVER 44' G MAX. 6- MAX. —� r— 6' MAX. FROM �— CENTER OF MEETING RAIL (X2) ANCHORAGE FOR AEt XO/OX CONFIGURAO 1 1ANCH0RON ANCHOR IANCHORON 1 ANCHOR AT EACH SIDE OF AT EACH SIDE OF 1 ANCHOR AT CORNER THE MEETING FIXED THE MEETING CORNER 1 RAn . RC RAn MIN. 3 ANCHORS IN JAMB FOR WINDOWS UP TO 44', MIN.4 ANCHORS IN JAMB FOR WINDOWS OVER 44' J_ 6' MAX �1 170 C rL _L 6' MAX W MAX 6 MAX. FROM MEETING RAIL (X2) ANCHORAGE FOR ALL XOX (1/3-1/3-1/3) CONFIGURATIONS 6' MAX. — X R / 1T O.C a ,_----------. 6' MAX 1 22-3/4' 1 _ — ]MAX. U.CJ MEETING RAIL ()(2) ANCHORAGE FOR ALL XOX (1/4-1/2-1/4) CONFIGURATIONS TARLE 2- FRAME TYPE FRAME WIDTH FRAME HEIGHT 383/B' ANCHOR GROUP 44' ANCHOR GROUP 50b/B' ANCHOR GROUP 63" ANCHOR'GROUP A B C A B C A B C A IS? C 53=V8' 1 1 1 1 1 1 1 1 1 1 t IIF74j 2 2 1 1 2 1 1 1 1 1 1� 1 STANDA D 1. 2 2 2 2 _ 2 1 1 2 1 1 1 1 MEETING RAIL 97- 0 2 3 2 2 2 2 2 2 t 1 1 1 10g' 3 3 2 2 3 2 2 2 2 1 2 1 120' 3 3 3 3 3 2 2 2 2 2 2 1 531/B' 1 1 1 1 1 1 1 1 1 1 1 1 HEAVY 74' 2 2 1 2 2 1 2 2 1 1 1 1 DUTY 85' 2 2 2 2 2 2 2 2 2 2 2 1 MEETING 97' 2 3 2 2 3 2 2 2 2 2 2 2 RAIL 10g' 3 3 2 3 3 3 3 3 2 2 2 2 120' 3 4 3 3 4 3 3 3 3 2 2 2 XO, OX & XOX: EGRESS HEIGHT: (WH - 4-5/8 XO & OX: EGRESS WIDTH: (WW/2-3-12) XOX (1/4-12.1/4): EGRESSWIDTH: (WW/4-2-5/16) XOX (1/3-1/3-1/3): EGRESS WIDTH: (WW/3-6) X. XO, OX 8 XOX: SASH VISIBLE LIGHT HEIGHT: (WH - 6A18) FIXED VISIBLE LIGHT HEIGHT: -4-7/8 XO & OX SASH B FIXED VISIBLE LIGHT WIDTH: 12-3-7116 XOX (1/4-12-1/4): SASH VISIBLE LIGHT WIDTH: (WW/4-3-7/16) FIXED VISIBLE LIGHTWIDTH: (WW2-3-13/16) XOX (113-1/3.1/3): SASH & FIXED VISIBLE LIGHT WIDTH: (WW13. 3-9/16) PRODUCT REVISED SEE TABLE 1, SHEET 1 FOR ANCHOR GROUP DESCRIPTIONS. as complying with the Florida Duild,g Code ... Aoceptanco too I.6-��•�i� Ezpim]' Date �. Raviead By: Dole: Reriaion: Dy - N!i Dade Pro�et Revfaed Ry: Data R�vialon: - ® D—viptlan: Drvrn BY: 6.I .[C ANCHOR SPACING & QUANTITIES J ROSOWSKI 1070 TECHNOLOGY DRIVE Lee: Data N. vENICE, FL 34275 HORIZONTAL ROLLER WINDOW DETAILS 12/01/11 P.O. BOX 1529 • `...`^ ,'" -' NOK0MIS: FL 34274 SWdslModel: Scab: Shoal: A LYNMILLERP.ECENT. OF H R-210 NTS 2 OF 8 1MryDq-HNoR. 21 O-01 PEp 58705 ReBr. AUlH a • a TART F A- XD oR OX CONFIGURATIONS MAXIMUM DESIGN PRESSURE RATING s (P FRAME WIDTH GLASS 'TYPE = v^STANDARD'MEETING RAIL) HEAVY DUTY MEETING RAIL "FRAME-FiEIGHT— FRAME HEIGHT 383/8" 44" 50-51W f,-63"-1 383/8" 44" 50518" 63" 72" Glass 1 +55.01-96.0 +55.01.90.0 +55.01-86.9 + 5-OA67.9 +55.0/-90.0 +55.0/-90.0 +55.0/56.9 +55.0/•67.9 N/A 26-1/2" Glass 2 & 3 +55.01-90.0 +55.01-90.0 +55.0/ 90.0 +55.01-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/50.0 +55.01-90.0 Glass 4 & 5 +55.01-90.0 +55.01-90.0 +55.0/50.0 +55.0I-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/30.0 +55.01-90.0 Glass 1 +55.01-73.5 +55.01-61.2 +55.0156.0 +49.71.49.7 +55.01-73.5 +55.01-61.2 +55.0/56.0 +49.71-49.7 N/A 37" Glass 2 & 3 +55.0/-90.0 +55.01-90.0 +55.0/-87.2 +55.0/57.2 +55.01-90.0 +55.0/-90.0 +55.01-90.0 +55.01.90.0 +55.01-77.9 Glass 4 & 5 +55.01.90.0 +55.0150-0 +55.0/-90.0 +55.01-84.0 +55.0/-90.0 +55.01-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/-78.1 Glass 1 +55.0/57.5 +53-7153.7 +44.6/-44.6 +35.5135.5 +55.0/-67.5 +53.71.53.7 +44.6/-44.6 +35.5/-35.5 WA 45" Glass 2 +55.01-90.0 +55.01.90.0 +55.0/ 75.0 +55.0157.1 +55.0/-90.0 +55.0/30.0 +55.0/-89.2 +55.0/ 77.2 +55.01.65.6 Glass 3 +55.0/-90.0 +55.0190.0 +55.01-75.0 +55.0157.1 +55.0/-90.0 +55.0/-90.0 +55.0/-80.3 +55.0/-63.9 +55.01-57.1 Glass 4 & 5 +55.0/-90.0 +55.01-90.0 +55.0/-90.0 +55.0/-71.4 +55.01-90.0 +55.0/50.0 +55.01-90.0 +55.0/-77.4 +55.01-66.0 Glass 1 +55.0/56.0 +53.1/53.1 +43.6143.6 +32.31-32.3 +55.0/-66.0 +53.1/53.1 +43.6/-43.6 +32.3/32.3 WA 49" Glass 2 +55.01-90.0 +55.01.85.1 +55.01-70.5 +53.41-53.4 +55.01-90.0 +55.0/58.9 +55.0/-79.9 +55.0/58.0 +55.0/-61.3 Glass 3 +55.01-90.0 +55.01-85.1 +55.01-70.5 +53.4153.4 +55.01-90.0 +55.0/-90.0 +55.0/-78.5 +55.0/58.1 +50.6/50.6 Glass 4 & 5 +55.0l-90.0 +55.01-90.0 +55.01-88.1 +55.01-66.7 +55.01-90.0 +55.0/50.0 +55.01-90.0 +55.0/ 72.3 +55.01-61.5 Glass 1 +55.01-63.7 +52.4/52.4 +43.51.43.5 +31.21-31.2 +55.0/-63.7 +52.4/52.4 +43.5/-43.5 +31.2131.2 NIA 53-1/8" Glass 2 +55.01-90.0 +55.01-81.0 +55.01.66.7 +50.21-50.2 +55.0/-90.0 +55.0/-85-0 +55.0/-73.8 +55.0/59.4 +54.0/-54.0 J F—Glass 3 ) +55.01-90.0 +55.0/-81.0 +55.01-66.7 5�M21502 a+55.0/-90.0 +55.0/-90.0 +55.0/-78.3 +55.0/56.2 +46.8/46.8 `Glas"s 4-& 5 +55.0/-90.0 +55.01-90.0 +55.0/53.4 +55.0/-62.7 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.0/-68.0 +55.0/-57.4 Glass 1 +55.0/59.2 +50.4150.4 +42.81-42.8 +31.8/-31.8 +55.0/59.2 +50.4/50.4 +42.8/-42.8 +31.8/31.8 WA 61" Glass 2 +55.01-89.2 +55.0/ 75.1 +55.01-61.1 +45.41-45.4 +55.0/59.2 +55.01-79.3 +55.0/-67.2 +51.0/51.0 +44.0/-04.0 (;Gla`ss 3) +55.01-90.0 +55.01-75.1 +55.01-61.1 F45X:45-4' ^+55.0/-90.0 +55.0/-90.0 +55.0/-77.0 +55.0/57.2 +46A/•46.4 Glass 4 & 5 +55.0/-90.0 +55.0/30.0 +55.01-76.4 +55:0f-56:T ° -+55.0/-90.0 +55.0/-90.0 +55.0/-82.9 +55.0/-61.5 +51.81-51.8 Glass 1 +55.0/56.3 +48.5/-08.5 +41.6141.6 +32.0/32.0 +55.0/-56.3 +48.51.48.5 +41.6/-41.6 +32.0/32.0 NIA Glass 2 +55.01-79.7 +55.0/-72.5 +55.0158.5 +43.0/-43.0 +55.0/-79.7 +55.0/-77.1 +55.01-65.2 +49.3/-49.3 +41.2/41.2 65, Glass 3 +55.01-79.7 +55.0/ 72.5 +55.0/-58.5 +43.01-43.0 +55.0/-79.7 +55.01-79.7 +55.0/-74.9 +55.0157.6 +47.0/•47.0 Glass 4 & 5 +55.01-79.7 +55.01-79.7 +55.01-73.1 +53.8153.8 +55.01-79.7 +55.0/-79.7 +55.0/-79.3 +55.0/58.3 +48.9/-48.9 Glass 1 +51.1/-51.1 +44.2/-44.2 +38.9138.9 +30.0130.0 +51.11-51.1 +44.2/-44.2 +38.9/38.9 +30.0130.0 WA Glass 2 +55.01-63.5 +55.0/53.5 +55.0155.3 +40.0140.0 +55.01-63.5 +55.0/-63.5 +55.0/-62.0 +47.9/-47.9 +39.8/39.8 74" Glass 3 +55.0/-63.5 +55.01.63.5 +55.0/55.3 +40.0/40.0 +55.0/-63.5 +55.0/-63.5 +55.01-63.5 +54.1/54.1 +45.0/-05.0 Glass 4 & 5 +55.01-63.5 +55.0/53.5 +55.01-63.5 +50.01-50.0 +55.0/53.5 +55.0/-63.5 +55.0/53.5 +54.2154.2 +45.1/-45.1 TARI F 4- Glass Types 1 1/8" Annealed 1/B" Tempered 2 3/15' Annealed 1/4' Annealed 3 118'Annealed-1/4" Airspactl/8" Annealed 3 3116%AnnealR:3916" Airspace-1/8" Annealed 4 3/16" Tempered 1/4" Tempered 6 118" Tempered-1/4' Airspace-1/8" Tempered 2116" Tempered-V16" Airspace-1/8" Tempered NOTES: 1) USE THIS TABLE FOR ALL XO1OX WINDOWS PER THE ELEVATION ON SHEET 1. DIMENSIONS SHOWN ARE TIP -TO -TIP. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) DESIGN PRESSURES MAY BE INTERPOLATED BETWEEN SIZES. CONFIGURATIONS APPLICABLE TO THIS SHEET: XO a OX FRODUC REV)SED . eamptyi"B %61th aee Fimi a Bdldrng Cale Aa.ep im, 1� 9 2 >:,�t 1 � Date de Pduct Dy m o r. p o (J) `N- U O O� E 04 o 02 O X Z Ll- O �' OM X LU LU J U) F- CC �z W Q d Z Z O .. CV e� N J 8��2 ® ONPN m r�>,�j'yJ'vNi n l°pV o�xc' Mo Q 0;cim o E g o= U h, A. LYNN MILLER. P - P.E.# 53705 TABLE 5: XOXCONFIGURATION MAXIMUM DESIGN PRESSURE RATING (psi) FRAME WIDTH GLASS TYPE STANDARD MEETING RAIL HEAVY DUTY MEETING RAIL FRAME HEIGHT FRAME HEIGHT 38.3/B" 44" 5D-5/8" 63' 383/8" 44" 50-5/8" 63" 49„ Glass 2 & 3 +55.01-90.0 +55.0/-90.0 +55.0/-76.3 +65.0/-59.2 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +55.01-78.9 Z p Glass 4 & 5 +55.0/-90.0 +55.0/-90.0 +55.0/-89.1 +55.0/-69.1 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.0/-90.0 53-1/8" Glass 2 & 3 +55.01-90.0 +55.01-84.7 +55.0/-71.4 +55.01-55.1 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.01-73.5 Glass 4 & 5 +55.01-90.0 +55.0/-90.0 +55.0/-83.2 +55.0/-64.3 +55.01-90.0 +55.0/-90.0 +55.01-90.0 +55.01-90.0 O LL 61" Glass 2 & 3 +55.0/-90.0 +55.01-76.3 +55.0/-63.9 +49.0/49.0 +55.0/-90.0 +55.0/-90.0 +55.01.85.1 +55.0/-65.3 Z Glass 4 & 5 +55.01-90.0 +55.01-89.0 +55.0/-74.5 +55.01-57.1 +55.0/-90.0 +55.0/-90.0 +55.01-90.0 +55.01-84.5 U 74" Glass 2 & 3 +55.0/-81.0 +55.0/56.8 +55.0/-55.3 +41.9/41.9 +55.0/-90.0 +55.0/-88.9 +55.01-73.7 +55.0/55.8 Glass 4 & 5 +55.01-90.0 +55.0/-77.9 +55.0/-64-5 +48.8/-48.8 +55.0/-90.0 +55.01-90.0 +55.01-90.0 +55.0/-72.2 85" Glass 2 & 3 +55.01-75.6 +55.0/-61.5 +50.4/-50.4 +37.7137.7 +55.0/-90.0 +55.01-81.8 +55.01.67.2 +50.3/-50.3 Glass 4 & 5 +55.0/-88.2 +55.0/-71.7 +55.0/-58.8 +44.0/-44.0 +55.0/-90.0 +55.0/-90,0 +55.01.86.9 +55.01.65.0 90 Glass 2 & 3 +55.0/-73.8 +55.01-59.6 448.61 48.6 +36.21-36.2 +55.0/-90.0 +55.0/-79.5 +55.0lE4.8 +48.2148.2 Glass 4 & 5 +55.01-86.1 +55.01-69.6 +55.0/-56.7 +42.2/-42.2 1 +55.0/-90.0 1 +55.0/-90.0 +55.0/-83.9 +55.0/52.4 Glass 2 +55.01-90.0 +55.01-79.5 +55.0/-66.4 +50.8/50.8 +55.0/-90.0 +55.0/-85.0 +55.0/-73.8 +55.0/-59.4 53-1/8" Glass 3 +55.01-90.0 +55.01-79.5 +55.01-66.4 +50.8/-50.8 +55.0/-90.0 +55.01-90.0 +55.01-78.3 +55.0155.2 Glass 4 & 5 +55.01-90.0 +55.0/-90.0 +55.01-77.5 +55.01-59.2 +55.0/-90.0 +55.0/-90.0 +55.0/-90.0 +55.0/-87.5 Glass 2 +55.0/-80.4 +55.0/-64.9 +52.9/-52.9 +39.3/-39.3 +55.0%83.1 +55.0/-72.8 +55.01-62.0 +47.9/47.9 0 74" Glass 3 +55.01-80.4 +55.0/-64.9 +52.91-52.9 +39.31-39.3 +55.01-90.0 +55.0/-79.6 +55.01-70.0 +52.5152.5 F- Glass 4 & 5 +55.0/-90.0 +55.01-75.8 +55.0/-61.8 445.9/-45.9 +55 0/-90.0 +55.0/-90.0 +55.01-90.0 +55.0/57.8 Glass 2 +55.0/-74.7 +55.01.61.2 +49.1/-49.1 +35.8/-35.8 +55.01-74.7 +55.0/-67.2 +55.0/58.9 +46.8146.8 85" Glass 3 +55.01-77.2 +55.01-61.2 +49.1/-49.1 +35.805.8 +55.0/-81.9 +55.0/-71.1 +55.0/52.8 +47.8/47.8 zGlass 4 & 5 +55.01-90.0 +55.01-71.4 +55.0/-57.3 +41.81-41.8 +55.0/-90.0 +55.0/-90.0 +55.0/-84.6 +55.0/51.8 U Glass 2 +55.0/-65.3 +55.01-58.8 +46.3/-46.3 +33.1/-33.1 +55,01-65.3 +55.0/-60.0 +53.7/53.7 +43.9/-43.9 97" Glass 3 +55.01-72.5 +55.0/-58.8 +46.3/-46.3 +33.1/-33.1 +55.0/-72.5 +55.0/-63.7 +54.7/-54.7 +44.2/-44.2 al Glass 4 & 5 +55.01-87.0 +55.01.68.6 +54.1/-54.1 +38.7/-38.7 +55.0/-90.0 +55.0/-90.0 +55.0/-79.9 +55.0157.1 Glass 2 +55.01-56.7 +53.41-53.4 +44.7/-44.7 +31.2/-31.2 +55.0/-56.7 +53.4/-53.4 +48.4/-48.4 +40.51-40.5 109' Glass 3 +55.0/-64.8 +55.0/-55.8 +44.7/-44.7 +31.21-31.2 +55.0/-64.8 +55.0/-55.8 +48.21.48.2 +39.6139.6 Glass 4 & 5 +55.01-84.7 +55.0/56.5 +52.21-52.2 +36.4/-36.4 +55.0/-90.0 +55.0/-90.0 +55.01-77.1 +53.8153.8 Glass 2 +49.7149.7 +47.91-47.9 +43.61 43.6 +30.0/-30.0 +49.71-49.7 +47.9/47.9 +44.3/-44.3 +37.5/-37.5 120" Glass 3 +55.01-57.6 +51.11-51.1 +43.6/-43.6 +30.0/-30.0 +55.0/57.6 +51.1/-51.1 +44.11-44.1 +35.8135.8 Glass 4 & 5 +55.01-83.2 +55.0/-65.0 +50.9/-50.9 +35.0/-35.D +55.0/-90.0 +55.0/-90.0 +55.01-75.2 +51.7/-51.7 TARLE e- Glass Types 2 3/16' Annealed 1/4" Annealed 3 1/8" Annealed-1/4" Airspace-1/8" Annealed 3/16' Annealed3/16" Airspace-1/8" Annealed 4 3116' Tempered 1/4" Tempered 6 1!8" Tempered-1/4" Airspace-1/8" Tempered 3116' Tempered-3116" Airspace-1/8" Tempered NOTES: 1) USE THIS TABLE FOR ALL XOX WINDOWS PER THE ELEVATIONS ON SHEET 1. DIMENSIONS SHOWN ARE TIP -TO -TIP. 2) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE WIDTH OR HEIGHT DIMENSION SHOWN ON THE TABLE. 3) DESIGN PRESSURES MAY BE INTERPOLATED BETWEEN SIZES. CONFIGURATIONS APPLICABLE TO THIS SHEET: XOX 0/3-1/3-1/3) � a XOX(114-1/2-114) PRonuCC REVISED u rnmplpog with the Merida Quildidg Coda Expimi 1Date By Mi Uade Pr act O o 0 9.0 „ U -1 d Q. pp Q N o 5 Q g= O o X Z LL A H O 00 W to H co NON LL Az Y, W J Q $ a Z o Z O _N 5W i3O rc a oO �= X b OJ^�J J�KLL O =Vmm zax Sax 0 00Z z U ..... A. LYNN MILLER P.E. P. =.d 58705 INSTALLATION OPTION 1 CONCRETE/CMU INSTALLATION ANCHORS INTO 2% WOOD. PERANCHORREQUIREMENT OPTIONAL EDGE EMBEDMENT 8D ADDON 2X WOOD DISTANCE FLANGE Q 114MAX HEAD, SHIM SILL & JAMBS EDGE EMBED- DISTANCE ° MENT T}NT I TYP. ANCHOR ' 1 TYPE, EMBEDMENT AND EDGE "• jI I� DISTANCE PER Ij li SUBSTRATE, SEE II it TADLE 1, SHEET 1. I I I I� 21 �I INSTALLATION it it 1' OPTION 2 FIXED VISIBLE I I INSTALLATION II HT II II ANCHORS DIRECTLY HEIGHT II II II INTO MASONRY. II II II SASH TIPTO-TIP II II �I VISIBLE HEIGHT !LIGHT I II li HEIGHT STANDARD MEETING RAIL 06 X 1X WOOD TYP. ANCHOR TYPE, BUCKSTRIP, , EMBEDMENT AND EDGE SEE NOTE 2, CONCRE DISTANCE PER SUBSTRATE, THIS SHEET. OR CMU PER SEE TABLE 1, SHEET 1. . ANCHOF REQUIRI 10 MENT X SASH VISIBLE O VISIBLE LIGHT LIGHT WIDTH r _ — �._Un)i]( WIDTH EDGE DISTANCE 76 I FIXED I I�J 74 25 24 VISIBLE I I ��^'711 70 5 ' STANDARD 6 WIDTH EXTERIOR STANDARD 6 1X WOOD EMBED- MENT MEETING RAIL MEETING RAIL BUCK 15 INSTALLATION OPTION 3 BUCK WIDTH TIP -TO -TIP WIDTH INSTALLATION ANCHORS THROUGH 1X BUCKSTRIP HORIZONTAL SECTION A -A INTO MASONRY. 114' MAX. SHIM II �I II TYP.ANCHORTYPE, BUCK O I II X B12 STEEL 4 2X WOOD EMBEDMENT AND EDGE HEIGHT I SELF -DRILLING _ 10 X 11 II i t I� SMS (GS), SEE TABLE \ S E TABLE 1, SHEET 1. II it II 1, SHEET 1. 24 II �I II DADEAPPROVED —_--' II II II 32 MULLION. ALUMINUM, II i' �31 STEEL FRAMING OR STEEL SASH VISIBLE O 57 II STUD. SEE SUBSTRATE ^ LIGHT WIDTH Illffff" __ .___ II II PROPERTIES, TABLE 1. 4' CUT LENGTH SHEET 1. 12 Q EACH 3 MEETING RAIL EXTERIOR 25 , ll�� I FIXED VISIBLE INSTALLATION fl STANDARDLIGHT WIDTH INSTALLATION TYP. ANCHOR TYPE, OPTION 4 V MEETING RAIL 8 EMBEDMENT AND EDGE INSTALLATION OPTION 1 BUCK WIDTH 2 DISTANCE PER ANCHORS INSTALLATION SUBSTRATE, BEE TIP -TO -TIP WIDTH ANCHORS INTO 2X 29 TABLEI,SHEETI. DIRECTLYINTO WOOD. METAL. HORIZONTAL SECTION C-C 1X WOOD BUCKSTRIP, NOTES: PRODUCT REVISED SEE NOTE 2, 1) USE ONLY SUBSTRATE -APPROPRIATE ANCHORS LISTED ON TABLE 1 OF SHEET 1. FOLLOW EMBEDMENT AND EDGE a complying with the FtorMa THIS SHEET. DISTANCE LIMITS. ANY INSTALLATION OPTION SHOWN MAYBE USED ON ANYSIDE OF THE WINDOW. Building Code 1/4•MAX SHIM Accepam x6-O6�i. 0z 2) ALL WOOD BUCKS LESS THAN 1-1/2- -�• 2oZ�L. THICK ARE TO BE CONSIDERED 1X ReNsed By: Data: Revlsfon: INSTALLATIONS. 1X WOOD BUCKS ARE - - By 1X WOOD CONCRETE PER OPTIONAL. UNIT MAY BE INSTALLED •� a3e ��'� mot BUCK ° • ,"° * ° ANCHOR DIRECTLY TO SUBSTRATE. WOOD BUCKS _ RoNsod t7y: Dote: ReW1on: EXTERIOR REQUIREMENT DEPICTED AS 2X ARE 1.1/2' THICK OR . • •� GREATER. IXAND 2X BUCKS (WHEN • • • ° • ' USED) SHALL BE DESIGNED TO PROPERLY r _ O Dexripfion: Drawn BY: nn INSTALLATION TRANSFER LOADS TO THE STRUCTURE. P�j`I �.� ? INSTALLATION DETAILS, STD MR J ROSOWSKI OPTION 3 WOOD BUCK DESIGN AND INSTALLATION _ VERTICAL SECTION B-B INSTALLAT ON ANCHORS IS THE RESPONSIBILITY OF THE 1070 TECHNOLOGY DRIVE 7itte: Date: THROUGH IX BUCKSTRIP ENGINEER OR ARCHITECT OF RECORD. N. vENICE, FL 34275 HORIZONTAL ROLLER WINDOW DETAILS 12/01/11 MAXIMUM SHIM THICKNESS TO BE 1/4'. P.O. BOX 1529 INTO MASONRY. •''rf,'.��; NOKOMIS; FL 34274 Serfes/Modef. Smle: e4• Draning No. SheRev: A. LYNN MILLER, P.E.CERT. OF AUTH. #29298 HR-210 NTS 5 OF 8 MD-HR210-01 e RE4 56705 . 1 J INSTALLATION OPTION 1 CONCRETE/CMU PERANCHOR INSTALLATION ANCHORS INTO 2X WOOD. REQUIREMENT OPTIONAL 2X WOOD EDGE EMBEDMENT 80 ADDON DISTANCE -_ FLANGE @ _ 114' MAX HEAD, SHIM SILL & JAMBS EDGE EMBED- DISTANCE MENT ! ". f . TYP. ANCHOR I TYPE. EMBEDMENT , AND EDGE DISTANCE PEP. Ij II SUBSTRATE, SEE II II TABLE 1, SHEET 1. II I I II 21 INSTALLATION I� OPTION 2 FIXED VISIBLE II II II II �I INSTALLATION LIGHT !j II II ANCHORSDIRECTLY umrt-m I' Ij jl INTO MASONRY. TIP -TO -TIP HEIGHT BUCK HEIGHT HEAVY DUTY MEETING RAIL x f SASH I ` VISIBLE II'F LIGHT EXTERIOR 15 II II II SASH II II II VISIBLE II l l LIGHTE--�{ 1/4'MAX.SHIM HEIGHT 812STEEL O II II I x SELF -DRILLING it �I SIAS(G5), SEE TABLE 5.ElIll 1, SHEET I. DADE APPROVED 32 MULLION, ALUMINUM, 31STEEL FRAMING OR STEEL STUD. SEE SUBSTRATE 4'CUTLENGTHPROPERTIES, TABLE 1, 12 @ EACH SHEET1. MEETING RAIL INSTALLATION n TYP. ANCHOR TYPE, OPTION 4 V EMBEDMENT AND EDGE INSTALLATION DISTANCE PER ANCHORS SUBSTRATE, SEE DIRECTLY INTO TABLE 1, SHEET 1. METAL. 1X WDOD NOTES: BUCKSTRIP, 1) USE ONLY SUBSTRATE -APPROPRIATE SEE NOTE 2, ANCHORS LISTED ON TABLE I -OF SHEET 1. THIS SHEET. FOLLOW EMBEDMENT AND EDGE DISTANCE 1/4' MAX SHIM LIMITS. ANY INSTALLATION OPTION SHOWN MAY BE USED ON ANY SIDE OF THE WINDOW. IX WOOD • • 2) ALL WOOD BUCKS LESS THAN 1-12' THICK BUCK CONCRETE PER ,' ARE TO BE CONSIDERED IX INSTALLATIONS. IX ANCHOR _• WOOD BUCKS ARE OPTIONAL UNIT MAY BE EXTERIOR REQUIREMENT a • INSTALLED DIRECTLY TO SUBSTRATE. WOOD ' 1 • ., BUCKS DEPICTED AS 2X ARE I.12' THICK OR INSTALLATION GREATER. IX AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED TO PROPERLYTRANSFER OPTION 3 LOADS TO THE STRUCTURE. WOOD BUCK VERTICAL SECTION B-B INSTALLATION ANCHORS DESIGN AND INSTALLATION IS THE THROUGH 1X BUCKSTRIP RESPONSIBILITY OF THE ENGINEER OR INTO MASONRY. ARCHITECT OF RECORD. MAXIMUM SHIM THICKNESS TO BE 1/4•. 1X WOOD TYP.ANCHORTYPE, BUCKSTRIP, CR CONCR CONCRETE EMBEDMENT AND EDGE SEE NOTE 2, OR CMU DISTANCE PER SUBSTRATE. THIS SHEET. SEE TABLE 1, SHEET 1. PER ANCHOR REOUIRE- 10 MENT X -� SASH f O VISIBLE LIGHT . EDGE WIDTH DISTANCE h'. FIXED 74 VISIBLE IF�-- I ''. . . —1 �11 LIGHT TO 5 WIDTH 1X WOOD BUCK EMBED - MENT HEAVY DUTY 7 MEETING RAIL HEAVY DUTY MEETING RAIL INSTALLATION BUCK WIDTH OPTION 3 TIP -TO -TIP WIDTH INSTALLATION ANCHORS THROUGH 1X BUCKSTRIP HORIZONTAL SECTION A -A INTO MASONRY. 4 2X WOOD TYP.ANCHORTYPE, EMBEDMENT AND EDGE 0 X 11 DISTANCE PER SUBSTRATE, SEE TABLE 1, SHEET 1. SASH VISIBLE ) F LIGHT WIDTH r- r. _--. 45 FIXED VISIBLE r' LIGHT WIDTH INSTALLATION HEAVY DUTY PTION I MEETINGRAIL INSTALLATION ANCHORS INTO 2X BUCK WIDTH WOOD. TIP -TO -TIP WIDTH PRODUCT REVISED HORIZONTAL SECTION C-C o i d pllyi.3 i. the Planda Aoceptam No 022 1. ( Revlsed Sr. Dote: Revlsbn: pith' Date o2 - Pmdatt Revised By. Dote: ReV.A : . ® De dpiloa: Drown By: INSTALLATION DETAILS, HD MR J ROSOWSKI ...7.^"'`•'. 1IVE TECH 7111e: Date: ''r-. N0 , FL 342 R HORIZONTAL ROLLER WINDOW DETAILS 12101/11 ,.: P-0. Box 1529 NOKOMIS, FL.14274 Series�Nodeh fib; Sheet Dtowing No. Rev. A LYNN MILLER, P.E. CERT. OF AUD1. g29296 HR-210 NTS 1 6 OF 8 MD-HR210-01 B REA 68705 1/8"ANNEALED OR PRODUCT REVISED TEMPERED GLASS w complying with dw Florida 1 8 1 1luilding Cade �e 4040 k 90382' MIN. 8Y 27 I GLASS BITE Miwi nda Prv�cr I 81 6 40 ®ice '® ze I 10 i 1/8" GLAZING DETAIL � o �M 3/18' ANNEALED OR 1/4• ANNEALED OR a Uj TEMPERED GLASS TEMPERED GLASS 910 U) J 3 28 6 Q C a eIN 92 — 12 55 6 II g'g =Lu 6 .382°MIT .382'MIN. I,2GLASS BITE GLASS BITE -I � o81Q7 O g 1 FYI' Z LL I $O0 3/16" GLAZING DETAIL 114" GLAZING DETAIL Ca } W 40 0 .0 40 g z IM 8 2 H 12' MIN. O s z 6 FRAME SASH 40 MEETING GLASS STACK 111 x zs CORNERS CORNERS RAIL 1/4"AIRSPACE (1) 118'ANNEALED OR Tn Q TEMPERED GLASS 118" ANNEALED OR Q F-' O ASSEMBLY DETAILS ill if 93MPERED GLASS $ W O — 57 li II 5 z N _ .382' MIN. Ir I.I 9 GLASS BITE I II �oO a O OSILLADAPTER 81 {J 60-63 2 q ® C-5, q 1/2" I.G. GLAZING DETAIL 3 3 1/4" AIRSPACE o Zoo. _ SUmN Q 2 GLASS STACK o a o oZ Z 260' ANNEALED OR .330' 3/18'AIRSPACE TEMPERED I+- EM' TPERED GLASS 1/8' ANNEALED OR , O O(r A15" TEMPERED GLASS II I -57IIt 94 WEEPHOLES .382"1 II GLASS BITE 1.600" 81SILL WEEPHOLE DETAILS 6o63 SHOWN WI FORTW QUANTITY E COVERS. NDSPACIN 1/2" I.G. GLAZING DETAIL - SEE SHEET 1 FOR QUANTITY AND SPACING 3118" AIRSPACE A:ll'NN MILLER: P.E P.�.N 58705 ' J L 1 " " y TABLE 7: Item Dwg# Part# Description Material 1 215B 6215W Frame Head 6063-TB 2 204 0264W Frame Sill GOMJ5 3 265 6265BW Sill Adapter 6063-TS 4 218A 6218W Frame Jamb (Fixed) 6083-T6 5 219 6108BW Frame Jamb (Operable) 6063-T5 6 220B 6220W Fixed Meeting Rail 60637TB 7 267 6267W Healy Duly Fixed Meeting Rail 6063-TB 223A 6223W Sash Top & Bottom Rail 6003-TB 223A 6223W Sash Bottom Rail 6003-TB 221B 6221BW Sash Side Rail 6063-T6 222 6222W Sash Meeting Rail 6063-TS [20 270 6270W Doglwne Reinforcement 6063T8 2785 62785W Sash Stop 6053-T5 4080 74080BK Meeting Rail Sweep Latch Plug Rigid PVC 242 42105W Sash Top Guide (Anil -rack) Rigid PVC 227 42114W I End Cup Rigid PVC 23 1213 OQ200K .190" X 200" Won Wstp. (Frame) Flex PVC 70 24 4066 6406BG .187" X .23(' Fin Walp. 25 1003C 66601K Bulb Vinyl Wstp. (Sash) Flex PVC 70 26 275C 70275CK Frame Sill Gasket Polyethylene 27 273A 70273AK Frame Head Gasket Polyethylene 28 280 70280BK Sash Gaskets Polyethylene 29 7HRKITW Weephole Corer Plastic 30 1096 71096W Sweep Latch Cast Zlnc 225 42112N Roller Housing 8 Guide Vinyl 226 7BRWHL2 Roller Brass 1155 781 POA #8 X 1" QUAD Pn SMS Steel 1155-1 781 PDX #8 X 1" Sq. Pn. SMS 410 SS r44 781PSTX #8 X 1" Sq. Pn. Twin Fast SMS 410 SS 78)OOPSA #8X.375' Sq. Pn. SMS Steel 1016 785BWW 08X.625" Ph. FI. SMS Steel 1265-3 712653K I Setting Block 3132" X 1/4' X 1' EPDM 51 1267 71267N Setting Block 1/B' XII/2" XII EPDM 1625 61625W 1/8" Bead Aluminum 2719 65016W 3/16" Bead Aluminum 1263 65133W 1/4" Bead Aluminum 1253 6V1'48W I.O. Bead Rigid PVC r7O 1014 61014FW Screen Frame Aluminum 1631 47041W Screen Comer Key No Ring Vinyl 1630 47042W Screen Comer Key with Ring Vinyl 320 7320SPNG Screen Spring Spring Steel 74 1624 61624K Screen Spline - .135" Dig. Foam Rubber 75 1635 61635K Screen Spline - .135" Dia. Hard Rubber 78 Screen Cloth Fiberglass 00 134 66615W Add -on Flange (Optimal) 6063-TO 81 Dow Coming 899 Silicone Glazing Sealant or Equiv. g0 1/8" Annealed or Tempered Glass 91 3/16" Annealed or Tempered Glass 92 1/4" Annealed or Tempered Glass 93 1/8% 1/4' Air -118" An. OrTemp. I.G. 94 1/8"- 3110' Air - 3116' An. or Temp. I.G. Part# Description al 60 Kommeding 4SG TPS Spacer System 61 Quenex Super Spacer nXT with Hot Melt Butyl s tS=hhl 62 Quanex Dureseal Spacer ls 63 Cardinal )L Edge Spacer KhMKtlNL& It31 Krl-UKIO: --Of [[,WOO a aaru 2.000' $7s r-- STRUCTURAL 1.s4r OBUMEN 1/4' NOM. � 2.°�- WITH WRH DESICCANT EXT. GLAss � 4SG ITPS CE � zeta• .tier .0sa• .062• 2.428' Z124• 7s2r INT. GLASS .062' D62' .6s6'—�-II-- ALUMINUM 1O FRAME HEAD OFRAME SILL OSILL ADAPTER O FRAME JAMB (FIXED) REINFORCEMENT 6063-TCALULIINUM 60WMALUMNUM 8053-76ALWANJU 6063-T6ALUMNUM 5/i6"NOM. 1.542• t6sY BUTYL 8 DESICCANT Vt FOAM DU RASEAL� _ Exr. GLAss 61 SPACER 002 °� 062' —� .926• �• � tss2• ff—T 2$10'os3INT. GLASS��1.06rA62• �{LHOT-MELT BUTYL OFRAMEFRAME JAMB (OPERAaLE) FlXED MEtTNG RAIL Oi HD FlX® wEnNG RAIL OB SASH TOP 8 BOTTOM RAIL STRUCTURAL 6083-TSALUMINUM SILICONE 6063i-TS ALUMINUM 606}TSALUMNUM 6°63-T6 ALUMINUM FOAM 3116' NOM. { WITH I~ 1$16. 7.746' —►I DESICCANT SUPER °�' e62' EXT. GLASS 62 SPACER@ NXT"'I U. 1.asr 062 1 INT. GLASS � 8 e059-T8A UMINUM I' 60°3-Te ALUMNUMR 72 bO�Te AFL w1MR0EMENT POLYISO- DESICCANT FILL AREA BU NE SELL 5116' NOM. T— I �•+ leer SILICONE SEAL 781• .04f==V 1 I oso• ROLL -FORMED � �Tr STAINLESS STEEL XL EDGE' 1 .050' 83 SPACER 13 SASH STOP O ADDON FLANGE PRODUCT REVISED Fi(T'GLA`5'S 6063-TS ALUMINUM 0063.1`6ALUNNUM mComplying %'khdm F0da Building Code o& /� 1/111111 I1 r1 AcceptanceM IG-.02 N N 1, Reviled Ry: Dote: Revielon: E- rat DaC 2 o,,...... yM� L,ICENS ! JR 05/05/16 B)ADDED SPACERS iiy INT. GLASS P '' :�� ' Milm Q' •.,.A �� Rerleed W. Vote: Re ie- * : No, 58705 'O — ® Description: D-- ay: :goo • s D i6: �BOM 8r PART DETAILS J ROSOWSKI �(� ••-'IoRlOp,._•-��1 1070 TECHNOLOGY DRIVE Otfe: Data 1s`JS7 NAL G\�\` N. POIDBoz ,5 9275 HORIZONTAL ROLLER WINDOW DETAILS 12/01/11 '' ,JO I111110%, \ NOKOMIS,' FL 34274 Sedeo/Modd: Scale: Sheet D-19 No. Rer. A. L FAA 8 E05, P.E.CERT. OF A11711. g29296 HR-210 NTS 8 OF 8 MD-HR210-01 B a BCIS Hom i Log In 1 User Registration j Hot Topics i Submit Surcharge I Stats & Facts i Publications ' FBC Staff BCIS Site Map Links i Search Florida P 21 Product Approval USER: Public User a m W., Product Approval Menu > Product or Application Search > Application List > Application Detail ka FL # F11 31-R12mom X (C (0 Py Application Type Revision Code Version 201 Application Status Appro ed *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer GT Indust d—ss— Address/Phone/Email 1070 Technology Drive North Venice, FL 34275 (941) 486-0100 Ext22318 druark@pgtindustries.com Authorized Signature Jens Rosowski jrosowski@pgtindustries.com Technical Representative Jens Rosowski Address/Phone/Email 1070 Technology Drive Nokomis, FL 34275 (941) 486-0100 Ext21140 jrosowski@pgtindustries.com Quality Assurance Representative Address/Phone/Email Category Ekterior Doors Subcategory Swinging ExGerior;,�Door_•Assemblies Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications, Inc. Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Referenced Standard and Year (of Standard) Standard Year AAMA 450 2010 AAMA/WDMA/CSA 101/I.S.2/A440 2008 ASTM E-1886 2005 ASTM E-1996 2009 ASTM E-1996 2012 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A • Date Submitted 06/08/2017 Date Validated 06/09/2017 Date Pending FBC Approval Date Approved 06/14/2017 Date Revised 11/07/2017 Summary of Products FL Model, Number or Name Description 3.3311 1 CD?— 9Q Aluminum Hinged Door Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL331 R12 C CAC FD-290 Certification.odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 09/21/2018 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL331 R12 11 FD-290.Ddf pressure, size and anchorage information. Verified By: A. Lynn Miller, P.E. 58705 Created by Independent Third Party: No Evaluation Reports FL331 R12 AE FD-290 Evaluation.odf Created by Independent Third Party: No 331.2 FD-5455 Vinyl French Door & Sidelite/Transom Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL331 R12 C CAC Certification FD 5455.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 05/21/2020 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL331 R12 II FD-455.Ddf pressure, size and anchorage information. Also known as the Verified By: A. Lynn Miller, P.E. 58705 455 Series. Created by Independent Third Party: No Evaluation Reports FL331 R12 AE FD-455 Evaluation odf Created by Independent Third Party: No 331.3 FD-5555 Vinyl French Door & Sidelite/Transom Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL331 R12 C CAC Certification FD 5555.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 05/21/2020 Design Pressure: N/A Installation Instructions Other: Please see the Installation Instructions for design FL331 R12 11 FD-555.1)df pressure, size and anchorage information. Also known as the Verified By: A. Lynn Miller, P.E. 58705 555 Series. Created by Independent Third Party: No Evaluation Reports FL331 R12 AE FD-555 Evaluation.odf Created by Independent Third Party: No Back Next Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: �' el:_ Credit Card Safe GENERAL NOTES: 1) THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO COMPLY WITH THE FLORIDA BUILDING CODE FOR THE DESIGN PRESSURES LISTED. 2) WOOD BUCKS DEPICTED AS 1X ARE LESS THAN 1-1/2" THICK. 1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE. WOOD BUCKS DEPICTED AS 2X ARE 1-12" THICK OR GREATER. ATTACHMENT METHOD OF WOOD BUCKS SHALL BE DONE BY OTHERS. 3) SEE TABLE FOR MINIMUM EDGE DISTANCE FROM CENTER OF ANCHOR TO SUBSTRATE EDGE (EXCLUDING FINISH OR STUCCO). 4) SHIM EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE, USING SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. ANCHOR LOCATIONS & SPACING 37-3/8" OVERALL MAX. 36" BUCK MAX. (Z-BAR) 73-3/8" OVERALL MAX, �- 72" BUCK MAX. (Z-BAR) —� --� E TTSH OR PW 80-11/16" 27-112" INSERT 20" MAX, OVERALL MAX. MAX. o SEE 80" BUCK NOTE MAX {} A (Z-BAR) 21" MAX 5) ANCHORS SHALL BE COATED OR CORROSION RESISTANT AS APPROPRIATE FOR SUBSTRATE MATERIAL DISSIMILAR MATERIALS SHALL BE PROTECTED AS REQUIRED TO PREVENT REACTIONS. ALUMINUM SHALL BE PROTECTED FROM DISSIMILAR MATERIALS AS SPECIFIED IN THE FLORIDA BUILDING CODE. 6) ADHESIVE SEALANT SHALL BE USED BETWEEN SUBSTRATE AND FLANGE OR FIN. OVERALL SEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS. 7) MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, 2.7 KSI CONCRETE AND CONCRETE MASONRY UNITS COMPLYING WITH ASTM C-90. GLAZING COMPLIES WITH ASTM E1300. 8) THE 113 STRESS INCREASE WAS NOT USED IN THIS NOTE A: ANCHOR EVALUATION. THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF WOOD SCREWS. ANCHORS ARE REQUIRED 9) IF THE EXACT PRODUCT SIZE IS NOT LISTED IN THE WITHIN 3" OF THE TABLES, ALWAYS ROUND UP TO THE NEXT LARGER VALUE. CENTERLINE OF THE HANDLE AND/OR DEADBOLT. TABLE 1: Anchor Type Substrate Min. Edge Dist Min. Embedment 012'Steei,SMS Wood (Soulhem Pine) 9/15" 1J/8" —Steel Stud Gr33 3W .045 (18 GA) AOR50-6m 6083T5T Steel, A36 318' vir " 1/4" Masonry Anchor Concrete 1" 1-3/8" Hollow CMU 2-12" 1-1/4" NOTE: FOR ALL METAL bUaSTRAI Eb, b4 EMtlEU ISRAune wn.a 11­1 BEYOND INSIDE FACE OF MATERIAL TART F 9- 12-518" MAX. 14-7/e" I _ 3-15/16" MAX. f I_ MAX. SINGLE'' 13-1116" } �MAX. T I - SH OR PW SH OR PW 80-11/16" 27-1/2" INSERT INSERT OVERALL MAX. MAX. 0 80" BUCK a � MAX (Z-BAR) V 12-5/a' MAX. 1 3 MAX. MAX. I MAX. 6'-8" HI DOUBLE (XX) �37-3/8' OVERALL MAX. 36" BUCK MAX. (Z-BAR) 73-3/8" OVERALL 72" BUCK MAX. MAX. (Z-BAR) �) II II MAX. MAX. T SH OR PW } 96-11/16" OVERALL SH OR PW SH OR PW 96-11/16' INSERT 23-314" MAX. MAX, INSERT INSERT OVERALL MAX. J_ 12-114" 96MAX K 23-5/8" MAX. _ EE MAX. 23-5/8" o SMAX. o (Z-BAR) _ / A NOTE 96"BUCK 00 (Z-BAR) T—LI " 18" 1-5/ MAX, MAX. �yI — —�l _'It 3 1 3 /16 kj MAX. M5AX. MAX. I f MAX. MAX. 6-O' HI SINGLE(X) 9-0" HI DOUBLE (XX) AsTestad Configurations Max. Nom. Stze (m) Configuration Swing Direction Frame Type SRI Type DP (PSF) Certification Number Glass zCr:IS 8Uie V)o9le (A'1111 CO"ut=`swing'� FZ7 -9A a—xs• .R111i9W-(6U_ Wrr)2_n '+1=50- r 19D-789, 791 36x96 Single(X) OutsNing Zbar/Box Medium(bumper) +/-35 190-792 Min. 1/8" Temp., 72x96 Doubt. (I Out -swing Z-barBox Medium (bumper) +/-35 36x98 Single(X) Outfln-swing ZbarBox Low (saddle) +/-35• 793 794 Mono. or I.G. 72x96 Double M Out/In-swing I Z barMOx Law (saddle) +/- 35• "Umited Water (Water Infiltration Tested at 0 psQ. ` .•( ":....... � lr'% ' l J va ay. Lbls WtriE nEMrXJRnaxn6O1'fnaUxmYTAN® '-•O'`'.-'' :>t3£ .. `._`_ J. ROSOWSKI 09130111 ALUMINUM 6D63-T6 AAmPI✓bPR4TMV. NOICYerx7a p^T1q �� a i CS W wralrarlArowelFrMmL®rT AxlMalrarr+oernemRrcrmaana 1070 TECHNOLOGY DRIVE aft CABANA DOOR INSTALLATION :, .,T •.• 11a fn' 7Z7'•- NOKOMIS, FL 34275 FLCERT.OFAUTH.:29296 A. Lynn Miser. P.E. sreexem P.E. 4M705 CD-290 NTS 1 of 3 1093011JR INSTALLATION WITH BOX FRAME EDGE DISTANCE OPTIONAL OPTIONAL EDGE SU TgA SUBSTRATE OUT -SWING SHOWN SINGLE HUNG INSERT DISTANCE i SHOWN 'r Psustir(jA E EMBEDMENT j EMBEDMENT + 1X f— WOOD SHIM SHIM INSTALLATION NOTES: OPTIONAL OPTIONAL 1) SEE SHEET 1 FOR SPACING / OUT -SWING IN -SWING REQUIREMENTS. SHOWN SHOWN I Q BOX FRAME, 2) SEE TABLE 1 FOR ANCHORAGE EXTERIOR SHIM JAMB INSTALLATION AND SUBSTRATE REQUIREMENTS. n (DIRECTLY TO SUBSTRATE) 3) MAX. SHIM THICKNESS TO BE 1W. V (� 4) FOR HARDWARE DETAILS, SEE SUBSTRATE EXTERIOR EXTERIOR SHEET 3. SHIM n OPTIONAL FIXED LIGHT INSERT SHOWN BOX FRAME, HEAD INSTALLATION (DIRECTLY TO SUBSTRATE) OPTIONAL FIXED UGHT INSERT SHOWN EXTERIOR OPTIONAL SADDLE ^� THRESHOLD II II SHOWN to 6'I OPTIONAL FIXED LIGHT INSERT SHOWN BOX FRAME, OPTIONAL HEAD INSTALLATION SINGLE HUNG (USING 1X WOODBUCK) INSERT SHOWN OPTIONALo.00�oo'oo'oo'o KICKPLATE SHOWN 000 o'0000INSERT °oo u°o°° EXTERIOR EXTERIOR OPTIONAL OPTIONAL 2" 1-7/16" BUMPER BUMPER THRESHOLD THRESHOLD II SHOWN SHOWN 1X ul"u w- JAMB INSTALLATION EXTERIOR WOOD IN -SWING SHOWN (USING I WOODBUCK) J. HAEL) LKiH I INSERT SHOWN OPTIONAL .0;II�II'7��� ADJUSTABLE-0.1,. ��in. �•• IUG SWEEP (SADDLE 'HRESHOLD ONLY)C.rti!:19 Ili r o.r umnt va—r nx CR44trwaow.mm )SOWSKI 09/30/11 ALUMINUM6063-T6 �,`¢�, ,,,,,�,,,°f� SUBS IiA / SUB 'i H7/f// ,UCJI IC // / I / f070 TECHNOLO0Y DRIVE NOKOMIS, FL 34275 FLCERT. OF AUTM.:28290 >a CABANA DOOR INSTALLATION 2FRAME. SILL INSTALLATIONS A. Lynn Miller, P.E. #58705 a�w1.e CD-290 am: NTS e+.x 2 of 3 m.ora DM"VW 1093011JR a..- 4- • " INSTALLATION WITH Z-BAR FRAME EDGE _ DISTANCE EDGE DISTANCE I —� SU T E EMBEDMENT / EMBEDMENT SHIM l OPTIONAL OPTIONAL OUT -SWING IN -SWING e SHOWN SHOWN < a EXTERIOR EXTERIOR 1X WOOD SHIM TAR[ F a- HARnWARF IAl I FRAME TYPFSI Part# Description 7CDSP Lock Stdke Plate BFLATM Striker Backing Plate 7CDSPD8 Dead001t Strike Plate 7851WL4 N8J2 x .375 Ph. FI. S.S. 4U9tOK Lock Support Aasy. 7634FW 06 x .750 Ph. FL SMS 7CDSP Lock Strike Plat (Acew Sleb) 6FLATM Stoker Beoxing Plate (Aeft Slob) 7CDSPDB Deadboll Stdke Plate (Active Slab) 78518X5 f8.32 x .375 Ph. Fl. S.S. (Active Slab) SCDFW W rain Fearn Insert .3 318- 7DEAD DeadboWKnob (Active) 7KNOBO Knob Set precllw) 7CDKL0K8 DcadboltlKnob -M Md Braes(Ad iw) 7DBLK8 Double LAckset 69333W Hinge 41704 liinge Pin Cap 417DS l9nge Pin Bushing 7)00tOM Mop Pin 7VT45 Hoye Fiwt 7834FPTW N x.750 Ph. FLTEK SMS OPTIONAL OPTIONAL — FIXED LIGHT T FLIGHT INSERT INSERT SHOWN SHOWN Z-BAR FRAME, Z-BAR FRAME, OPTIONAL HEAD INSTALLATION HEAD INSTALLATION SINGLE HUNG (DIRECTLY TO SUBSTRATE) (USING 1X WOODBUCK) INSERT SHOWN OPTIONAL FIXED LIGHT INSERT SHOWN EXTERIOR OPTIONAL SADDLE THRESHOLD SHOWN OPTIONA KICKPLAT INSERT SHOWN EXTERI OPTIONAL 1-7/16" BUMPER THRESHOL SHOWN EXTERIOR OPTIONAL 2" BUMPER THRESHOLD SHOWN Z-BAR FRAME, SILL INSTALLATIONS SUBSTRATE SHIM OPTIONAL OUT -SWING SHOWN EXTERIOR Cr IGCTRATC 1X Z-BAR FRAME — JAMB INSTALLATION (DIRECTLY TO SUBSTRATE) OPTIONAL SINGLE HUNG INSERT SHOWN EXTERIOR Z-BAR FRAME, Uv I IUNAL OPTIONAL JAMB INSTALLATION FIXED LIGHT IN -SWING (USING 1X WOODBUCK) INSERT SHOWN I SHOWN INSTALLATION NOTES: 'r: • �,t_, i:,y-;�. 1)SEESHEET 1 FOR SPACING REQUIREMENTS. 2) SEE TABLE 1 FOR ANCHORAGE AND SUBSTRATE REQUIREMENTS. 3) MAX. SHIM THICKNESS TO BE 1/4. .... •• .` .•. n..,l er am 4r>b4.e rra<xwal(rcMlxAk' aw wreo�m J. ROSOWSKI 09130/11 ALUMINUM 6063-T6 '�drxeaal:amrrn�xneFwr emusr2evurmRras+e�a eclvvsm4l[ eF m. IbNNonc ,kvornu U4YMV=CR# xava=ft cOrFMNMVAM otrsxoxRtbx Avrrgs xrncvrIre"m Irwrre[ rwnmpna�Flrrew[arrte:a ® Omvyt6¢ / 1D70TECHNOLOGYDRNE NOKOMIS. FL 34275 FL CERT. OF AUTH.: 29298 CABANA DOOR INSTALLATION A. Lynn Mitler, P.E. er`.m.•CO�S 3 3 10930E-1JRP.E.#58705 .9n°.