HomeMy WebLinkAboutREVISION 2-2-18OFFICE USE ONLY:
DATE FILED:
REVISION FEE:.
PERMIT # 1712-071.0
RECEIPT #
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553 FAX (772) 462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCATION/SITE _e diterranean East
ADDRESS:.
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Changing to Impact Windows and Adding a.6x10 Slab Off Rear of Home
3. CONTRACTOR INFORMATION:
STATE of FL.REG./CERT. #: ST. LUCIE COUNTY CERT. #:. 8898
BUSINESS NAME: oipora ton
QUALIFIERS NAIVIF�O
ADDRESS: South U Suite 402
�80011 Hwy.
CITY:. o ucie STATE: ZIP:.
PHONE (DAYTIME): - FAX: 772 878-7 56
4. OWNER/BUILDER INFORMATION:
NAME: Wynne Building Corporation
ADDRESS: 8000 SouthHwy.Suite 402
CITY: STATE: FL ZIP: 34952
PHONE:. 772) 878-5513 FAX: (772) 878-7656
5.
ARCHITECT/ENGINEER INFORMATION: F$le,®iv
NAME: BRADEN,& BRADEN.
ADDRESS:
CITY: STUART STATE: FL_ ZIP,, 34996
PHONE (DAYTIME): (772) 287-8258 rm t
Revised 07/22/2014
z r PrIt
p)
lJor Ole Sieoe-
Not IncludiF .0 `his Permit
1Z
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL ,
Owner:kx p, (4 S�
Permit Number:
Jurisdiction:
Design Location: FL, orPierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 ftz
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftZ
5. Is this a worst case? Yes
10. Ceiling Types (1753.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753.00 ftz
6. Conditioned floor area above grade (ftz) 1753
b. N/A
R= ftZ
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 225
a. U-Factor: Sgl, U=0.63 111.36 ftz
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 40.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1753.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Total Proposed Modified Loads: 53.83
Glass/Floor Area: 0.086
PASS
Total Baseline Loads: 53.85
1 hereby certify that the plans and specifications covered by
Review of the plans and
ST I,,
this calculation are in compliance with the Florida Energy
specifications covered by this
p,e'Y114E
•ti
Code.
calc n ' es
``°•°,"„ ��
with a
PREPAR D BY:
Befo c ructi pl
DATE:
this ild it i f
I'�i
com e io
I hereby certify that this building, as designed, is in compliance
Flori
with the Florida Energy Code.
G'Op yyE�iv
OWNERq
BUIL I I AL.
DATE:��..
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
File Cop " .
4/16/2018 9:09 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE WINDSOR IM Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225
Street:
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 MASTER BATH
56 448, No
0
1
Yes
Yes
Yes
4 M.BATH
61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R
588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH
50 400 No
0
1
Yes
Yes
Yes
10 HALL
25 200 No
0
1
No
Yes
Yes
11 FOYER
92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 ft 0
224 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ft2
----
0 1
0
4Slab-On-Grade Edge Insulatio
M. BATH 7 ft 0
61 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft2
____
0 1
0
4/16/2018 9:09 PM EnergyGauge@ USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
-___
0
1
0
7Slab-On-Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft
0
209 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft2
____
0
1
0
11Slab-On-Grade Edge Insulatio
FOYER 9 ft
0
92 ft2
_---
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft2
____
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
# Type Materials
Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 1847 ft2
292 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
9
Adjacent
nrot To Wall Type0
Cav
Space ity Width
Height
Sheathing Framing
Solar
Below
1
NE=>W Exterior Concrete Block - Ext InEMASTER BE 4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
2
SW=>E Exterior Concrete Block - Ext InddASTER BE 4.1 7
0 8
0
56.0 ft2
0
0
0.5
0
3
NW=>S Exterior Concrete Block - Ext InsMASTER BE 4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
4
NE=>W Exterior Concrete Block - Ext InsMWSTER BA 4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
4/16/2018 9:09 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
Wall Typepace
Sle
Et In
Et In
Area
Alaille
Ahqor
Grade%
5
NE=>W Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.5
0
6
NE=>W Exterior
Concrete Block - Ext IndRffDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.5
0
7
SW=>E Exterior
Concrete Block - Ext IndMNING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.5
0
8
NW=>S Exterior
Concrete Block - Ext InMNING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.5
0
9
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.5
0
10
NE=>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.5
0
11
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.5
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
13
NE=>W Exterior
Concrete Block - Ext InSEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.5
0
14
SW=>E Exterior
Concrete Block - Ext InfiffDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
15
N=>SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.5
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V
# Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single Yes
0.63 0.25
N
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5
Metal Low-E Single Yes
0.63 0.25
N
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3 NE=>W 6
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4 SW=>E 7
Metal Low-E Single Yes
0.63 0.25
N
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.65 0.21
N
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6 NE=>W 13
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82
168.92
.2598
7
4/16/2018 9:09 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
V
--- Supply ----
---- Return --
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 225 ft2
Attic
65 ft2 Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinHJan
Feb
HFeb
Mar
Mar
Apr
f Apr I
Ma X Jun X Jul
Mayf Jun f Jul
X Aug
4 Auf
Se
Sep
Oct
Oct
Nov
Nov
H
Dec
Dec
Ventin
Jan Feb
X Mar
[x] A r
May [ Jun [ Jul
[ Aug
[ Se
[x]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66 .66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
4/16/2018 9:09 PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind popona and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover nlates and walls or ceffifffinas-
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/16/2018 9:09 PM EnergyGauge@ USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Sgl, U=0.63
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65
SHGC: SHGC=0.21
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
THE WINDSOR, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block- Ext Insul, Exterior
R=4.1
1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0
208.00 ft
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1753.00 ft2
1753
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
111.36 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 225
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ft2
13. Heating systems
a. Electric Heat Pump
2.850 ft.
0.239
Area
14. Hot water systems
1753.00 ft2
a. Electric
ft2
ft2
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. /1
Builder Signature: Date:
Address of New Home: City/FL Zip: IsZ.&II-1 the
CC'
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
Pstat
O� v4E Srq��o
`ll/Ih
0
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/16/2018 9:09 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1