HomeMy WebLinkAboutREVISION 3-27-18OFFICE USE ONLY: r
DATE FILED:
REVISION FEE: '7 h • on
1.
LOCATION/SM34 Cedro
ADDRESS: . .
PERMIT # 1712-0713
RECEIPT # 1 3 5 g 5?
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772) 462-1553 FAX (772) 462-1578
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Changing to Impact Windows and Adding a 6x10 Slab Off Rear of Home
SCANNE
BY
S)T LUCIF cni IN Y
3. CONTRACTOR INFORMATION:
STATE of FL.REG./CERT. #: ST. LVICIE COUNTY CERT. #: 8898
BUSINESS NAME: orpora ion
QUALIFIERS NA
ADDRESS:. 0 South U wy. ui e
CITY: Fort St. Lucie STATE: ZIP: 34
PHONE (DAYTIME): - FAX: 772 878-7 56
4. OWNER/BUILDER INFORMATION:
NAME: Wynne Building Corporation
ADDRESS: 8000 SouthHwy. 1 Suite 4
CITY: STAT . FA z. > r: 34
PHONE: (772) 878-5513 \:��'.
5. ARCHITECT/ENGINEER INFORMATION:
NAME: BRADEN & BRADEN � _ J ''I ow
ADDRESS:
CITY: STUART STATEZIP: 3499
PHONE (DAYTIME): 772) 287-8258s� `
Revised 07/22/2014,
File .C'oP3' ,
GA,
Not InTies On
nT4, is
4,
2� ........ .
in
7# 17/
ell
File COPY
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE T E GRAND CARL ON
. Street: C-SL
Builder Name: WYNNE BUILDING COPR.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1446.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: Sgl, U=0.36 101.25 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
H e
kBtu/hr Efficiency
d. U-Factor: N/A ft2
H p
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
'
Area Weighted Average SHGC: 0.239
4. ter t
le i
Cap: 40 gallons
8. Floor Types (1445.5 sqft.) Insulation Area
In'
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
b. o e a t
b. N/A R= ft2
one
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 47.17
Glass/Floor Area: 0.098
PASS
Total Baseline Loads: 48.08
�7
1 hereby certify that the plans and specifications covered by
Review of the plans and
114E ST,q?�
this calculation are in compliance with the Florida Energy
specifications covered by this
O
y _ Off,
Code.
calculation indicates compliance
with the Florida Energy Code.
nlrr,:n.a°•, •.;;:€ �.;,.� �;���0
PREPA D BY:
Before construction is completed
DATE: "(
this building will be inspected for
compliance with Section 553.908
* "'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
y�
with the Florida Energy Code.
COD WMS
OWNER/
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
File COPY
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street:
' Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort. Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM 301 2408 No
0
1
1 Yes
Yes
Yes
• 2 WIC 63 504 No
0
1 No
Yes
Yes
3 M.BATH 56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes
0
1 No
Yes
Yes
5 BATH 45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
301 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ft2
----
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft2
----
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0
55 ft2
----
0 1
0
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2n17
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
----
0
1
0
'
ROOF
/ Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
le Et In
Height
Et In
Area
Sheathing Framing
R-\/ni,le Eraction
Solar
Ahsor
Below
rr:;rie%
_ 1 NE=>SW Exterior Concrete Block - Ext InsiflEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext InsiHEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext InsiBEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InQEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext InQEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext InREDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InRffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsdIAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsGiREAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
DOORS
# Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
0.36 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
0.36 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
0.36 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.36 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2598
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType Location
EF Cap Use SetPnt
Conservation
1 Electric
None Garage
.0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ft2
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
DUCTS
---- Supply
----
---- Return ----
Air
CFM 25
CFM25
HVAC #
V/ # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
• 1
Attic 6
250 ft2
Attic
65 ftZ
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[ ] Jan
Heatin[ Jan
Feb
Feb
H
[ ] Mar
[Mar
f
A r
Apr
May
May
Jul
Jun Jul
Jun rl
rl
Aug
AuSep
rl
Se
Oct
Oct
Nov
Nov
Dec
Dec
Ventin [ j Jan
Feb
[X] Mar
[X
Apr [
May
JunJul
Aug
Se
Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 -68
68
68
68
68
66
66
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind 12il2ong and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire spriokl cover plates and walls or ceiling
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows- Description
a. U-Factor: Sgl, U=0.36
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65
SHGC: SHGC=0.21
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ftZ
b. Frame - Wood, Adjacent
R=11.0
192.00 ft
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ft2
1446
b. N/A
R=
ft2
c. N/A
R=
ft2
Area
11. Ducts
R ft2
101.25 ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ft2
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.8 HSPF:8.50
3.832 ft.
0.239
Area
14. Hot water systems
1445.50 ft2EF:
a. Electric
Cap: 40 gallons
0.97
ft2
b. Conservation features
ft2
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded) y�
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. rn,
Builder Signature: Date:
Address of New Home: ��jj� C,C City/FL Zip:�vQ,
T><YE Sr'q?F
�, w•;�`••O��p
v
;�0-D WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT-.
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1