HomeMy WebLinkAboutREVISION 5-31-18OFFICE USE ONLY:
.DATE FILED:
REVISION FEE:. —1 6 d
I:.. LOCATION/% ' GEDRO
ADDRESS:
PERMIT # 1712-0713
RECEIPT #
.RECEIVED .
PLANNING & DEVELOPMEN.T SERVIC S
BUILDING & CODE REGULATION DIVISIO MAY 2�18.
2360 VIRGINIA AVENUE
FORT PIERCE, FL 349.82-5652
(772).462-1553 FAX (772) 462-1578 ST. Lucie County; Permitting
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
3. CONTRACTOR INFORMATION:
STATE of FL.REQJCERT. #: ST. LUCIE'COUNTY CERT. #: 8898
BUSINESS NAME: didingorpora ion . .
QUALIFIERS NAM�
ADDRESS: 80 .0 South.USTMy. 1 Suire 402
CITY: Fort -St. - ucie STATE: ZIP:
PHONE (DAYTIME): - FAX: 772 87877656
A. OWNER/BUILDER INFORMATION:
NAME: Wynne Building Corporation
-ADDRESS. 8000 SouthHwy. I Suite 402
CITY: STATE: FL ZIP:" 34952
PHONE:.... (772) 878-5513 FAX: (7721878-7656 ' .
5. ARCHIT)ECT/ENGINEER-INFORMATION::
NAME: BRADEN & BRADEN
ADDRESS:
CITY: STUART STATE: FL ZIP: 34996
PHONE. (DAYTIME): (772) 287-8258 FAX:
Revised 07/22/2014
FILE
co
Py.
RFV0� W 0% N
Ist
BRADEN & BRADEN, A. I. A., P. A.
97rchilecb & "Planners
417 COCONUT AVENUE, STUART, FLORIOA 3499E
TELEPHONE: (772) 2B7-6256 FAX (772) 2B7-B283
#AAC-000032
ST. LUICE COUNTY BUILDING DEPT.
PERMIT # 1-112-0-113 ADDRESS: 13934 Cedro
PLEASES THE PRODUCT APPROVAL BELOW FOR THE MI WINDOWS
TO BE S ALLED AT THE ADDRESS STATED ABOVE.
SING RlREWY,
B
L R. BRADEN AIA
EN ! BRADEN AIA PA
W c� a
fV
LIJ
U O
W R N
°e == J
LL
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Skylights
Opening
Type
NOA/FL
NUMBER
product
Model //
Manufacturer
Glass
Attachment method
TEST
F.Vco�t'ation
Date
Design Pressure
g
of Approved Tests
1.2.3
E,1
FLU 11499.2
Single Hung
Serves 185
MI Windows
and doors
om R ca sin L�oce thereae�'ter thr g�n�`lf `g kti to —n
fioedh°;tJaaan eamcen Ore min zs• saga e,. aaca m et..t a"aner....
± LO psf
A
I6-0330.02
Overhead
Garage Door
Model 824/811
9'-4' max width
IL'-O' max height
DAS
me " .ram �m sic i e'•Nde NLC S4we ant . tt a ac
h q. u x�`i die4`rr�1i r:ea ea'.a°ti �'." o1°``.t `ma.�w..a
sr i. - .eo. mrte""e - ae eo . s"os em+re to p."mxt •porwm
."wee. ,gw• .".h.. "a
10-9-21
+ 50.0/-GO.O paf
B
FLtt ILLl4.l
Fiberglass
Des. nPro/
Smooth Pro
Jeld-Wen
El- I/4' die. top— with inn 1.25' embedment at 3' max
from corners and 1�.5' o.c. max thereafter in heed and iambs.
+ 50.0 PSF
C
FLtt 15332.2
Sliding Glass
Door
Series 420
MI Windows
and doors
L s Sara 3 na fpc°ne w dw�ie row tfeHO e�ierihr°rtag`ry
min 2.5' sage dntenca
PT tnctkaIn �ei"dicia Ni tAe nodman approve.
+ 48.2 PSF
Product
NOA/FL
NUMBER
Model $
Manufacturer
Attachment Method
TEST ation
Date
Design Pressure
of Approved Tests
Mullions
FL# 15355.8
CM-18531
vertical mullion
MI Windows
and doors
For C;U we. (2) 1/4' x 2 3/4' tepcarw with min 1 1/4' embedment
penetration into each Null Clip. Attach mull to chp uang N) a10 x 1.25'
self tapping screws par cup as shown in produce approval.
+ 118.9 PSF
Roof
FLU IIL51.12
SV Crimp
Metal l2ooFing
Gulf Coast Supply
and manufacturing
ZL a. Sv trim metal rooting attached to plywood deck uang a9 x 1.5'
woo a with Belt eaahng washer et IZ' o.a. max seating over AST; D
(type 2) 30 Ib felt underleyment installed with min. 4 ode Iap, and L' end
IeeCpe fsstened with corroaon reeiatant tin cape end meth 1.25' ring shank nale
deck to tru see wung ape
hment detelgee"m room epic^' o.e. in field. Attach
- 108.5 PSF
Siding
Stucco on Block
Soffit
FLU IG503.1
12 Model Triple 4 "
vented Vinyl 1 12
Kaycan
Install using 2" x 2" battens at L' o.c. screwed to eofrit framing using
98 x 3" wood screws at each truss. Install sofrit to battens using
0.12' die. x 1.5" long up shank neila with 3/8' die. head. Using
J-Channel to J-Channel-inatallation.
± 66.1 PSF
Hurricane
Panels
FIU 15016.2
24 Gauge
Storm Panels
Global Protection
PdLLC
Products
Install using 1/2• die. solid set lead anchor. with I/4" die.-20 x 1.5"
long 55 screw head combo. with Neoprene washer at 12 1/2' o.c .
along the bottom and 13' o.c. at the top
± 45.0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record
. FORM R405-2017
'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: N E THE GRAND CARLTON
Builder Name: WYNNE BUILDING COPR.
�VffN
C Street: Qt '� \ r��w
Permit Office: ST. LUCIE COUNTY
-0
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1446.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: Sgl, U=0.54 101.25 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1445.5 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ft2
b. Conservation features
b. N/A - R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.35
PASS
Total Baseline Loads: 48.09
1 hereby certify that the plans and specifications covered by
Review of the plans and
4ggE S,q?,
this calculation are in compliance with the Florida Energy
specifications covered by this
1,0�
Code.
calculation indicates compliance
with the Florida Energy Code.
PREP REDaiek6
DATE: - 4 1
Before construction is completed
this building will be inspected for
compliance with Section 553.908
r '
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
CODS
OWNER/A E T6
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). J- i7t°f`=T110r%
FRLEC,5/29/2018 7:10 Mg ug AR405.4.1 Compliant Software
MAY 31 2018
ST. Lucie County,
Page 1 of 5
FORM R405-2017 INF'U 15UMMAKY UHLUKLIb I KLI'UK I
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M.BATH 56 448 No 0
1 Yes
Yes
Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
301 ftZ
----
0 1
0
2 Slab -On -Grade Edge Insulatio WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ftZ
----
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ftz
----
0 1
0
5 Slab -On -Grade Edge Insulatio BATH 5 ft 0
45 ftz
----
0 1
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ftZ
----
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0
55 ftZ
----
0 1
0
5/29/2018 7:10 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5
FnRM R4O5-g017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
_---
0
1
0
ROOF
/ Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
IRCC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) -ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing
Solar
Below
Space
# Ornt To Wall Type1
NE=>SW Exterior Concrete Block - Ext InstflEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
2 SW=>NE Exterior Concrete Block - Ext InsBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
3 NW=>SE Exterior Concrete Block - Ext InsdflEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
_ 5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InMDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext InfiffDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext InRffDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
6.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsLllAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGiREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
_ 15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
5/29/2018 7:10 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5
FnRM RAns_9nl7 IMP11T S1IMMARY CHECKLIST REPORT
DOORS
# Ornt
Door Type
Space
Storms U-Value Width
FtIn
Height
Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1
6 8
20.6 ftz
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
Wall
V # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation
Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Yes
Yes
Yes
Yes
Yes
0.54 0.25 N 32.9 ftz 1 ft 0 in 1 ft 4 in
0.54 0.25 N 6.9 ftz 1 ft 0 in 1 ft 4 in
0.54 0.25 N 24.0 ftz 6 ft 0 in 1 ft 4 in
0.54 0.25 N 37.5 ftz 1 ft 0 in 1 ft 4 in
0.55 0.25 N 40.0 ftZ 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2578
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/
Split
HSPF:8.5 34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None
ftz
5/29/2018 7:10 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
DUCTS
—
Supply ---
-- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN
RLF
Heat Cool
1 Attic
6 250 ft2
Attic
65 ft2
Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[ Jan
Feb
[[ ]] Mar
Apr
Jun
Jul
Au
Se
[ j Oct [
Nov
Dec
He f X� Jan EX
Feb
[X] Mar
f
Apr
I
jMa
May
Jun
rj
Jul
rl
AuSep
rl
rl
[ ] Oct [X1
Nov
X Dec
Ventin [[ Jan [[
Feb
[X Mar
[X
A r
May
Jun
Jul
Aug
Se
[X] Oct [X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80 80
80
80
PM
80
80
78
78
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (VVD)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
Oft
0.3
BEDROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
ENTRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/s .ft.
ft2
ft
0.3
GREAT/DINING
Name: Test Rater
Rating Compant: Test Rater
Signature: I
Qga�2&XW
Date: " J�
5/29/2018 7:10 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind poping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or cemlings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
5/29/2018 7:11 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL .(EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index,
1
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
2
13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. 'Conditioned floor area (sq. ft.)
6.
1446
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.543
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
34.8
c) Area
7c.
141.3
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
11.0
2. Masonry (Insulation R-value)
1062.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: City/FL Zip: FT. PIERCE. FL
5/29/2018 7:10:47 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1