Loading...
HomeMy WebLinkAboutHVAC LOAD CALCULATIONSSCANNED 3T Limp- COUNT Kathy's for Kathy FILE COPY Prepared By: Residential Energy Calc's Monday, October 03, 2005 Project Report Project Title: Kathy's !residence Designed By: Linear Drafting Project Date: Monday, October 03, 2005 Client Name: Kathy Company Name: Residential Energy Calc's Reference City: Fort Pierce, Florida Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter. 42 0 30 72 3 Summer: 90 78 50 75 61 Total Building Supply CFM: 1,935 CFM Per Square ft.: 0.620 Square ft. of Room Area: 3,123 Square ft. Per Ton: 641 Volume (W) of Cond. Space: 31,868 Air Turnover Rate (per hour): 3.6 Total Heating Required With Outside Air: 62,212 Btuh 62.212 MBH Total Sensible Gain: 43,819 Btuh 78 % Total Latent Gain: 12,119 Btuh 22 % Total Cooling Required With Outside Air: 55,938 Btuh 4.66 Tons (Based On Sensible + Latent) 4.87 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use andweather may vary. Be sure to select a unit that meets both sensible and latent loads. Rhv_ic -Residential N Light Commercial HVAC Loads Elite Software Development, inc, � Ken.Humphrey 4 i Port SaintLucie FL 34983' Kathy's Res dance rage 3.171 E Miscellaneous Report 1 System�1�,Ruud®r`Equivalent"'` " 'f``a `"®utdoor ' ` ®utdoor I"ndoor Intlo�or Grams Rel.Hq7M7 J1111M „ Differences i j Winter: 42 0 30 72 3.44 i Summer 90 78 50 75 61.09 Systern2 R�UudlOr'Equlvalent'` Outdoor Outdoor Indoor Indoor` ` Grains i I In utData's �, ._ . _.. }. _�. .�. . �. d -r<. D i.. Butb . VUet Bulb,. - yRel_ Hum -. ©a Bulb=__ Difference Winter: 42 0 30 72 3.44 Summer: 90 78 50 75 61.09 Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor. 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. I Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. j OutsideAir'Data Gr,. :.E�Z «,,,r� r�� _004 . Winter Summer infiltration: 0.409 AC/hr 0.213 AC/hr Above Grade Volume: X 31,868 Cu.ft. X 31,868 Cu.ft. 13,040 Cu.ft./hr 6,772 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 217 CFM 113 CFM j Total Building Ventilation: 78 CFM 78 CFfvi ' --System 1-- IInfiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp_ Difference) —System 2— Infiltration & Ventilation Sensible Gain Multiplier. 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 4 I = (1.10 X 0.999 X 30.00 Winter Temp. Difference) i Rhve'c - Residential c& Light Commercial HVAG Loads Elite Software Development, inc. j f; Ken Humphrey Kathy's RGsiftnce j ' Port Saint Lucie, FL 34983 e 4 I; Load Preview Report , 5 -: ..� w Sens r' Lat i "6;r 1,. Net Sen, s "` Wimi Sum�_��Os : Duct; F f Sco ea ".'<� Area; Gam , , Gain q Gain Loss CFM CFMM Size4: Buildm 4 66°Net Tons; 4 87 Recommended T6Ks,.r`,641�%?/ ron; 62 2=1 MBH,�Heatin ;. .,. _ _«.s, , ,,,.y_. ,: 1 Building 3,123 43,819 12,119 55,938 62,212 582 1,935 1,935 i I S stem 2lTon,=_27�97MBHHeatm"";��*9,,f_x",' F System 1 1,330 20,994 5,571 26,565 27,970 264 934 934 12x14 Ventilation 462 1,162 1,624 923 AED Excursion 2,416 2,416 f j Duct Loads 7,166 2,097 9,262 6,765 Zone 1 1,330 10,951 2,312 13,263 20,282 264 934 934 I 1-Master Suite 293 3,583 870 4,453 6,683 87 306 306 3-6 2-Walk In Closet 107 300 109 409 861 11 26 26 1-4 f '3-Master Bath 159 1,671 162 1,833 1,940 25 143 143 1-7 f 4-Bedroom 2 194 1,319 174 1,493 1,816 24 113 113 1-6 j 5-Bedroom 3 194 1,319 174 1,493 1,816 24 113 113 1-6 ; i 6-Bath 3 165 739 148 887 1,380 18 63 63 1-5 7-Bedroom 4 218 2,020 675 2,695 5,786 75 172 172 2 5 S stem-2; 2.45 Net Tons,3 2, 54° Recommended Tons r 707 zft'�?Ffon; 34, 24 MBH Heatm OM- W'' `, . <" j System.2 1,793 22,826 6,548 29,374 34,242 318 1,001 1,001 12x15 g 1 Ventilation 824 2,075 2,899 1,649 Duct Loads 5,920 1,602 7,522 8,132 I Zone 2 1,793 16,081 2,871 18,952 24,462 318 1,001 1,001 i f 8-Foyer 96 885 149 1,034 1,549 20 55 55 1-4 j 9-Gallery Room 176 169 0 169 210 3 11 11 1-4 j j 10-Living 484 2,644 389 3,033 4,346 56 165 165 1-8 !i 11-Playroom Bath 84 80 0 80 121 2 5 5 1-4 12-Play Room 251 2,145 473 2,618 4,750 62 134 134 1-7 1 13-Laundry 107 1,940 654 2,594 2,802 36 121 121 1-7 j 14-Kitchen 196 2,515 261 2,776 2,132 28 157 157 1-7 j 15-Dining 186 2,196 248 2,444 2,497 32 137 137 1-7 j 16-Hobby Room if I , 1 f� I �I II � 213 3,507 697 4,204 6,055 79 218 218 2-6 1 I I !I , t RJivsc Resi on{iat.&I Light Commercial HVAC Loads Elite Software Development, Ir!G. I Ken I-1 mphrey Kathy's Residence I Port SaintLucie, FL 34983 Total Building Summary Loads j j Component Area Sen Lat Sen Total j I Descri tion G2uan Loss Gain Gain Gain IA-cb-o: Glazing -Single pane, operable window, clear, 327 10,594 0 12,827 12,827 metal frame with break, outdoor insect screen with i 50% coverage, light color blinds at 450 with 50% i coverage, u-value 1.08 IA-cm-o: Glazing -Single pane, operable window, clear, 60 2,286 0 2,090 2,090 metal frame no break, u-value 1.27 11 D: Door -Solid Core 42 492 0 426 426 j 13A-4ocs: Wall -Block, board insulation only, R-4 board 2332 10,007 0 5,104 5,104 insulation, open core, siding finish f 16DR-30: Roof/Ceiling-Under attic or knee wall, Vented 3120.7 2,996 0 2,995 2,995 i Attic with Radiant Barrier, White or Light Color i Shingles, Any Wood Shake, Light Metal, Tar and Gravel Membrane, R-30 insulation 122A-ph: Floor -Slab on grade, No edge insulation, no 275 11,204 0 0 0 j insulation below floor, any floor cover, passive, heavy f moist soil Subtotals for structure: 37,578 0 23,442 23,442 People: 1 200 230 430 Equipment: 300 1,500 1,800 } Lighting: 0 0 0 Ductwork: 14,897 3,698 13,086 16,784 Infiltration: Winter CFM: 217, Summer CFM: 113 7,166 4,683 1,860 6,543 ' Ventilation: Winter CFM: 78, Summer CFM: 78 2,572 3,237 1,286 4,523 AED Excursion: 0 0 2,416 2,416 Total Building Load Totals: 62,212 12,119 43,819 55,938 Cheek Fi -g ures Total Building Supply CFM: 1,935 CFM Per Square ft.: 0.620 l Square ft. of Room Area: 3,123 Square ft. Per Ton: 641 Volume (ft') of Cond. Space: 31,868 Air Ti urnover Rate (per hour): 3.6 Buildin • Loads i Total Heating Required With Outside Air: 62,212 Btuh 62.212 MBH Total Sensible Gain: 43,819 Btuh 78 % Total Latent Gain: 12,119 Btuh 22 % Total Cooling Required With Outside Air: 55,938 Btuh 4.66 Tons (Based On Sensible T Latent) 4.87 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. l kl I I { j � ` i 'R�yac- Resi ential & Light Commerciai HVAC Loads - Elite Software Development, Inc. Kathy's Residence' roA. Saint Luce, FL 34933 Pa a 12 I System 1 Ruud Or Equivalent Summary Loads. I' Component Area Sen Lat Sen Total ®escri _ion I Quan Loss Gain Gain Gain ( 1A-cb-o: Glazing -Single pane, operable window, clear, 148.5 4,811 0 5,910 5,910 metal frame with break, outdoor insect screen with Ij i 50% coverage, light color blinds at 45° with 50% coverage, u-value 1.08 j 13P.-4ocs: Wall -Block, board insulation only, R-4 board 1232.5 5,289 0 2,698 2,698 insulation, open core, siding finish i 16DR-30: Roof/Ceiling-Under attic or knee wall, Vented 1328.1 1,275 0 1,275 1,275 1 Attic with Radiant Barrier, White or Light Color i 1 Shingles, Any Wood Shake, Light Metal, Tar and Gravel Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 138 5,622 0 0 0 insulation below floor, any floor cover, passive, heavy I I ! moist soil Subtotals for structure: 16,997 0 9,883 9,883 1 People: 1 200 230 430 1 Equipment: 0 0 0 i Lighting: 0 0 0 1 Ductwork: 6,765 2,097 7,166 9,262 Infiltration: Winter CFM: 100, Summer CFM: 51 3,285 2,112 838 2,950 { Ventilation: Winter CFM: 28, Summer CFM: 28 923 1,162 462 1,624 AED Excursion: _ _ 0 0 2,416 2,416 ( System 1 Ruud Or Equivalent Load Totals: 27,970 5,571 20,994 26,565 I Check Fi u, rLes Supply CFM: 934 CFM Per Square ft.: 0.702 Square ft. of Room Area: 1,330 Square ft. Per Ton: 570 I Volume (ft) of Cond. Space: 13,281 Air Turnover Rate (per hour): 4.2 j S stem Loads { Total Heating Required With Outside Air: 27,970 Btuh 27.970 MBH i Total Sensible Gain: 20,994 Btuh 79 % I Total Latent Gain: 5,571 Btuh 21 % f Total Cooling Required With Outside Air: 26,565 Btuh 2.21 Tons (Based On Sensible + Latent) 2.33 Tons (Based On 75% Sensible Capacity) � Notes ! Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. l I ,RhvAc Residential & Light commercial HVAC Loads Mite Software Develo�rnent, Inc. f I Ken Humphrey AN& Kathy's Residence 1 :Pori Saint Lucie, FL 34983 Page 13 � `; System 2 Ruud Or Equivalent Summary Loads 1 1 { Component Area Sen Lat Sen Total Descri tion Quan Loss Gain Gain Gain111 1A-cm-o: Glazing -Single pane, operable window, clear, 60 2,286 0 2,090 21090 ! metal frame no break, u-value 1.27 1A-cb-o: Glazing -Single pane, operable window, clear, 178.5 5,783 0 6,917 6,917 metal frame with break, outdoor insect screen with I 50% coverage, light color blinds at 45' with 50% coverage, u-value 1.08 11 D: Door -Solid Core 42 492 0 426 426 { 13A-4ocs: Wail -Block, board insulation only, R-4 board 1099.5 4,718 0 2,406 2,406 1 insulation, open core, siding finish 1 16DR-30: Roof/Ceiling-Under attic or knee wall, Vented 1792.6 1,720 0 1,720 1,720 Attic with Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 137 5,582 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil _ Subtotals for structure: 20,581 0 13,559 13,559 1 People: 0 0 0 0{ 1 Equipment: 300 1,500 1,800 Lighting: 0 0 0 1! Ductwork: 8,132 1,602 5,920 7,522 Infiltration: Winter CFM: 118, Summer CFM: 62 3,881 2,571 1,022 3,593 1 _Ventilation: Winter CFM: 50, Summer CFM: 50 _ _ 1,649 2,075 824 2,899 System 2 Ruud Or Equivalent Load Totals: 34,242 6,548 22,826 29,374 i Chec�Fi • ures I, Supply CFM: 1,001 CFM Per Square ft.: 0.558 Square ft. of Room Area: 1,793 Square ft. Per Ton: 707 1 Volume (ft') of Cond. Space: 18,587 Air Turnover Rate (per hour): 3.2 S stem Loads j Total Heating Required With Outside Air: 34,242 Btuh 34.242 MBH Total Sensible Gain: 22,826 Btuh 78 % f Total Latent Gain: 6,548 Btuh 22 % I Total Cooling Required With Outside Air: 29,374 Btuh 2.45 Tons (Based On Sensible + Latent) 2.54 Tons (Based On 75% Sensible Capacity) Notes 1 Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. ! Be sure to select a unit that meets both sensible and latent loads. I I I I I f Ker,Humphrey _ - J Kathy's System 1, Zone 1 Summary Loads (Average Load Procedure for Rooms) IA-cb-o: Glazing -Single pane, operable window, clear, 148.5 4,811 0 5,910 5,910 metal frame with break, outdoor insect screen with 50% coverage, light color blinds at 450 with 50% coverage, u-value 1.08 13A-4ocs: Wall -Block, board insulation only, R-4 board 1232.5 5,289 0 2,698 2,698 insulation, open core, siding finish 16DR-30: Roof/Ceiling-Under attic or knee wall, Vented 1328.1 1,275 0 1,275 1,275 Attic with Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 138 5,622 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 16,997 0 9,883 9,883 People: 1 200 230 430 Equipment: 0 0 0 Lighting: 0 0 0 Ductwork: 0 0 0 0 Infiltration: Winter CFM: 100, Summer CFM: 51 3,285 2,112 838 2,950 System 1, Zone 1 Load Totals: 20,282 2,312 10,951 13,263 Check Figures Supply CFM: 934 CFM Per Square ft.: 0,702 Square ft. of Room Area: 1,330 Square ft. Per Ton: 1,152 Volume (ft') of Cond. Space: 13,281 Air Turnover Rate (per hour): 4.2 Zone Loads Total Heating Required: 20,282 Btuh 20.282 MBH Total Sensible Gain: 10,951 Btuh 83 % Total Latent Gain: 2,312 Btuh 17 % Total Cooling Required: 13,263 Btuh 1.11 Tons (Based On Sensible + Latent) 1.15 Tons (Based On 75% Sensible Capacity) ftgt—eslll Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Rh c & Light Commercial _ VAC Loads � Elite Software Development, iResidence,� I h Yential Kathy's 241 Port -Sant Lucie, FL 34983 Pa a � I Detailed Room Loads - Room 1 - Master Suite (Average Load Procedure) "G"eneral Calculation Mode: Htg. & clg. Occurrences: 1 Roam Length.- 19.5 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: 293.0 sq.ft. Supply Air: 306 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 6.3 AC/hr Volume: 2,925.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 3 Actual Winter Vent.: 9 CFM j Runout Air: 102 CFM Percent of Supply.: 3 % i I Runout Duct Size: 6 in. Actual Summer Vent.: 9 CFM j Runout Air Velocity: 519 ft./min. Percent of Supply: 3 % 1 Design Loss: 0.100 in.v4g./100 ft. Actual Winter Infil.: 32 CFM Actual Loss: 0.172 in.wg./100 ft. Actual Summer Infil.: 16 CFM Item Area -U- Htg Sen C►Ig Lat Sen j ffiD tion Quantit. Vialue H�TjM Loss HTM Gain Gain j N -Wail-13A-4ocs 6.3 X 10 33 0.143 4.3 142 2.2 0 72 j NW-Wall-I3A4ocs 4.5 X 10 30 0.143 4.3 129 2.2 0 66 1 NE-Wall-13A-4ocs 4.5 X 10 30 0.143 4.3 129 2.2 0 66 1 W -Wall-13A-4ocs 16.5 X 10 165 0.143 4.3 708 2.2 0 361 1 1 E -!Nall-I3A-flocs 12 X 10 120 0.143 4.3 515 2.2 0 263 j N -GIs-IA-cb-o shgc-0.75 100%S 30 1.080 32A 972 21.5 0 644 (2) NW Gls-lA-cb-o sh gc-0.75 0%S 15 1.080 32.4 486 44.5 0 667 NE-Glsa1A-cb-o shgc-0.75 0%S 15 1.080 32.4 486 44.5 0 667 1 UP-Ceii-16DR-30 19.5 X 15 292.5 0.032 1.0 281 1.0 0 281 Floor-22A_ph 44 ft..Per. 44 1.358 40.7 1,793 0.0 0 0 _ Subtotais for Structure: _ 5,641 0 3,087 1 Infil.: Win..- 31.6, Sum.: 16.1 438 2.379 1,042 0.607 670 266 People: 0 lat/per, 2 30 sen/per: 1 I' �1 Room Totals: I I i _-- -- -- _-- ----- -- --- - -- 6,683 --- 870 ----- 3,583 + I i I -hY4c Rexic]ential &Light Cornrnercial HVAC Loads Elite Software Develooment, Inc. � xbn Humphrdy I . , Kathy's Residence' 1 I Pod Saint Lucie, FL 34983 Page 25.11 Detailed Room Loads - Room 2 - Walk In Closet (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 15.0 ft. System Number: i Room Width: 7.1 ft, Zone Number: 1 Area: 107.0 sq.ft. Supply Air: 26 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 1.4 AC/hr Volume: 1,065.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 26 CFM Percent of Supply.: 5 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 293 ft./min. Percent of Supply: 3 % Design Loss: 0.100 '1n.wg./100 ft. Actual Winter Infil.: 5 CFM Actual Loss: 0.099 in.wg./100 ft. Actual Summer Infil.: 3 CFM W -Wall-l3A-4ocs 7A X 10 UP-Ceii-16DR-30 15 X 7.1 Floor-22A-ph 7 ft..'Per. Subtotals for Structure: irmi . Win.: 5.1, Surn.: 2.6 Room Totals: 106.5 0.032 1.0 7 1.358 _ 40.7 71 2.380 SEE Clg Lat j Fr5a .oss H,1TM Gain 305 2.2 0 1 Lou 102 1.0 0 102 285 0.0 0 0 692 0 257 j 169 0.606 109 43 861 _ 109 300 R9iy?4 Re���sn#gal � Lich# Gnrt�mg�r.�a� lii/ji% L4��c ���#g Gr1f#trear9 i 3g�@it��_►t!@cif; 1�1ri, I v-n Hu hray � Kathy's Residence I roil Sane Lucie, FL 34983 rage 26 I ;Detailed Room Loads - Room 3 - Master Bath (Average Load Procedure) General III Calculation Mode: Htg. & clg. Occurrences: 1 I Room Length: 15.0 ft. System Number: 1 1 Room Width: 10.6 ft, Zone Number: 1 Area: 159.0 sq.ft. Supply Air: 143 CFM i 1 Ceiling Height: 10.0 ft. Supply Air Changes: 5.4 AC/hr Volume: 1,590.0 cu.ft. Required Vent.: 0 CFM I Number of Registers: 1 Actual Winter Vent.: 3 CFM I Runout Air: 143 CFM Percent of Supply.: 2 % j Runout Duct Size: 7 ,in. Actual Summer Vent.: 4 CFM Runout Air Velocity: 533 ft./min. Percent of Supply: 3 % 1 Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 8 CFM 1 Actual Loss: 0.147 in.wg./100 ft. Actual Summer Infil.: 4 CFM j Item Area -U- Htg Sen Clg�1!, P1101 en 1 Quantit Value HTM Loss HTM aain f V"J -Wall-13A-flocs 40.6 X 10 83.5 0.143 4.3 358 2.2 0 183 ' W -GIs-1A-cb-o shoe-0.75 4%S 22.5 1.080 32.4 729 56.5 0 1,271 UP-Ceil-16DR-30 15 X 10.6 159 0.032 1.0 153 1.0 0 153 1 I Floor-22A-ph 11 ft..Fer. 11 1.358 40.7 448 0.0 0 0 I Subtotals for Structure: 1,688 0 1,607 1 Infil.: Win.: 7.6, Sum,: 3.9 106 2,377 252 0.604 162 64 j 1 Room Totals: I i I { t 1 1,940 162 1,671 i I I � I - 9 - .ram, Rhveic Resin ntial & Light Commercial VAG Loans j' Elite Software Devei�ipnme"t; Inc. u� y h Katy 's Resi�anc2 I 1 .on ., u`ilr. ey 1 I I ro`t Saint. Lucie FL 34983 Page 41 11 Detailed Room Loads - Room 4 - Bedroom 2 (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 11.4 ft, Zone Number: 1 Area: 194.0 sq.ft. Supply Air: 113 CFM Ceiling Height., 10.0 ft. Supply Air Changes: 3.5 AC/hr Volume: 1,938.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 113 CFM Percent of Supply.: 2 % Runout Duct Size: 6 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 573 ft./min. Percent of Supply: 3 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 8 CFM Actual Loss: 0.210 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item Area -U- Htg ImUKsQriPt$6n Quantity Value oHTM W -Wall 13A-flocs 11.4 X 10 99 0.143 4.3 425 2.2 W -GIs-lA-cb-o shgc-0.75 4%S 15 1.080 32.4 486 56.5 UP-Coil-16DR-30 17 X 11.4 193.8 0.032 1.0 186 1.0 Floor-22A-ph 11 ft..Per. _ 11 1.358 40.7 448 0.0 Subtotals for Structure: 1,545 (_nfil.: Win.: 8.2,Sum.: 4.2 _ 114 2,377 271 .0,605 Room Totals: 1,816 0 847 1 0 186 1 0 0� 0 1,250 174 69 j 174 1,319 l�hya� ga5id�anii i + ?r�hr Cr�rnnearriai i FiC Loads Elite Software Development [nr_ i Ken Hump'. vathys Qesidance- f r�a[$ai[u LUGie, rL 34983 '�i' . ` - Page 25 ` Detailed Room Loads - Room 5'- Bedroom 3 (Average Load Procedure) ;General Calculation Mode: Htg. & cig. Occurrences: 1 Room Length: 17.0 ft. System Number: 1 Room Width: 11A ft. Zone Number: 1 Area: 194.0 sq.ft. Supply Air: 113 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 3.5 AC/hr Volume: 1,938.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 113 CFM Percent of Supply.: 2 % Runout Duct Size: 6 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 573 ft./min. Percent of Supply: 3 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 8 CFM Actual Loss 0 210 in.wg /100 ft. Actual Summer Infil.: 4 CFM jItem Area -U- Htg Sen C*Ig Lat Sen j I Descri tion Quantit Value HTM Loss HTM Gain Gain W -Wail-13A-4ocs 11.4 X 10 99 0.143 4.3 425 2.2 0 217 1 1 W -GIs-lA-cb-o shgc-0.75 4%S 15 1.080 32.4 486 56.5 0 847 1 I UP-Ceii-I6DR-30 17 X 11.4 193.8 0.032 1.0 186 1.0 0 186 I Floor-22A-ph 11 ft.. Per. 11 1.358 40.7 448 0.0 0 0 Subtotais for Structure: 1,545 0 1,250 I Infil.: Win.: 8.2, Sum.: 4.2 — —__ 114 2,377 271 0.605 — 174 -- 69 1 Room Totals: 1,816 174 1,319 Rbyh-r Re-idenfial A Lin Com-nnearcial HVAG Loads � Elite- Software Development, Inc. ' 's Klen�Kumphrey K2th Red "snce l I 1 Pori Saint Lucie FL 34983 Page I Detailed Room Loads - Room 6 - Bath 3 (Average Load Procedure) ;1 General Calculation Mode: Htg. & clg. Occurrences: 1 j Room Length: 17.0 ft. System Number: i I Room Width: 9.7 ft, Zone Number: 1 Area: 165.0 sq.ft. Supply Air: 63 CFM l 1 Ceiling Height: 10.0 ft. Supply Air Changes: 2.3 AC/hr I Volume: 1,649.0 cu.ft. Required Vent.: 0 CFM I I Number of Registers: 1 Actual Winter Vent.: 2 CFM j I Runout Air: 63 CFM Percent of Supply.: 3 % Runout Duet Size: 5 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 462 ft./min. Percent of Supply: 3 % l Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 7 CFM ! Actual Loss: 0.177 in.wrg./100 ft. Actual Summer Infil.: 4 CFM 1 Item Area -U- Htg Sen Clg Lat Sin l Descri tion Quantit Value HTM Loss HTM Gain Gain W AtUli- i 3A-4ocs 9.7 n 10 91 0.143 4.3 390 2.2 0 199 j j W-GIs-IA-cb-o shge-0.75 12%S 6 1.080 32.4 194 53.8 0 323 ( UP-Ceil-16Do-30 17 X 9_7 164.9 0.032 1.0 158 1.0 0 158 1 Floor-22A-ph 1Oft.. Per. 10 1.358 40.7 407 0.0 0 0 Subtotals for Structure: 1,149 0 680 Infil.: Win.: 7.0, Slam.: 3.6 97 2.381 231 0.608 148 59 Room Totals: i 4 I 1,380 148 739 f f I i vefr Resid6ntial &,Light Cominerrial HVAC Loads Elite Soft -were reveiopment- i! n<HumphreyAli& y Kathy's Resider ii S&A Lucie FL 34983 l Page I Detailed Room' Loads - Room 7 - Bedroom 4 (Average Load Procedure) General Calculation Mode- Htg. & clg. Occurrences: 1 Room Length: 17.0 ft. System Dumber: 1 Room Width: 12.8 ft, Zone Number: 1 Area: 218.0 sq.ft. Supply Air: 172 CFM Ceiling Height. 10.0 ft. Supply Air Changes: 4.8 AC/hr Volume: 2,176.0 c.,.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 8 CFM I Runout Air: 86 CFM Percent of Supply.: 5 % i Runout Duct Size: 5 in. Actual Summer Vent.: 5 CFM Runout Air Velocity: 632 ft./min. Percent of Supply: 3 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 32 CFM Actual Loss: 0.328 in.wg./100 ft. Actual Summer Infll.: 16 CFM i Item Area -U- Htg Sen Clg Lat Sen Descri tion Qua tit Value HTM Loss HTM Gain Gain I W -Wall-13A-4ocs 12.8 X 10 128 0.143 4.3 549 2.2 0 280 I S -Wall-13A-4ocs 17.3 X 10 143 0.143 4.3 613 2.2 0 313 I c -Wall-l3A-flocs 14 X 10 140 0.143 4.3 601 2.2 0 306 I S-GIs-lA-cb-o shgc-0.75 100%S 30 1.080 32.4 972 21.5 0 644 (2) I UP-Ceil-16DR-30 17 X 12.8 217.6 0.032 1.0 209 1,0 0 209 Floor-22A-ph 44 ft_.Per. 44 1.358 40.7 1,793 0.0 0 0- Subtotals; for Structure: 4,737 0 1,752 Infil.: Win.: 31.8, Sum.: 16.3 _ — —_ 441 2.379 1,049 0.608 _ 675--- 268 i Room Totals: 5,786 675 2,020 j Rhvat: - Resiopntial & Light Commercial HNAC Loads Elite Software Development, Inc. j Ken Humphrey # Kathy's Residence j 1 Port Saint Lucie, FL 34983 Page 31 f , Detailed Room Loads - Room 8 - Foyer (Average Load -Procedure) :,General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.0 ft. System Number: 2 Room Width: 8.0 ft. Zone Number: 2 Area: 96.0 sq.ft. Supply Air: 55 CFM i F Ceiling Height: 10.0 ft. Supply Air Changes: 3.4 AC/hr Volume: 960.0 cu.ft. Required Vent.: 0 CFM I I Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 55 CFM Percent of Supply.: 6. % Runout Duct Size: 4 in. Actual Summer Vent.: 3 CFM Runout Air Velocity: 631 ft./min. Percent of Supply: 5 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 7 CFM Actual Loss: 0.448 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item Area - I - Htg Sen Clg LatW:_1WSU11pfion Quantit Value HTM Loss HTM Gainn S -Wall-13A-4ocs 8 X 10 47 0.143 4.3 202 2.2 0 103 1 4 S-Door-11 D 3 X 7 21 0.390 11.7 246 10.1 0 213 I k S -GIs-IA-cm-o shgc-0.75 100%S 12 1.270 38.1 458 34.8 0 418 1 (2) UP-Ceii-16DR-30 12 X 8 96 0.032 1.0 92 1.0 0 92 Floor-22A-ph 8 ft..Per. 8 1.358 40.7 326 0.0 0 0 } Subtotals for Structure: 1,324 0 826 ! lnfil.-. Win.: 6.8, Sum.: 3.6 80 2.813 225 0.738 149 59 ( Room Totals: � I I I 1,549 149 885 I I Rhvac. - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken. Humphrey Kathy's Residence I Port Saint Lucie, FL 34983 ' Pa - a 32 I Detailed Room Loads - Room 9 - Gallery Room (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room'Length: 16.0 ft. System Number: 2 Room Width: 11.0 ft. Zone Number: 2 Area: 176.0 sq.ft. Supply Air: 11 CFM I Ceiling Height: 11.0 ft. Supply Air Changes: 0.3 AC/hr Volume: 1,936.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM j Runout Air: 11 CFM Percent of Supply.: 4 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM 1 Runout Air Velocity: 121 ft./min. Percent of Supply: 5 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 0 CFM Actual Loss: 0.018 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area -U- Htg Sen Clg Lat Sen eapxffl55 1uantit Value HTM Loss HTM Gain Gain j UP-Ceil-16DR-30 16 X 11 176 0.032 1.0 169 1.0 0 169 Floor_22A-ph 1 ft..Per. 1 1.358 40.7 41 0.0 0 0 Subtotals for Structure: 210 0 169 j Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 _ 0 _ _0 Room Totals: I I 210 0 169 I I f j Rhvac -Residential &Light Commercial HVAC Loads Elite Software Development, Inc. j i Ken Humphrey Kathy's Residence Port Saint Lucie; FL 34983 Pa a 33 Detailed Room Loads - Room 90 - Living (Average Load Procedure) i General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 25.1 ft. System Number: 2 Room Width: 19.3 ft. Zone Number: 2 Area: 484.0 sq.ft. Supply Air: 165 CFM Ceiling Height: 11.0 ft. Supply Air Changes: 1.9 AC/hr Volume: 5,329.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 9 CFM Runout Air: 165 CFM Percent of Supply.: 5 % Runout Duct Size: 8 in. Actual Summer Vent.: 8 CFM Runout Air Velocity: 471 ft./min. Percent of Supply: 5 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 18 CFM Actual Loss: 0.096 in.wg./100 ft. Actual Summer Infil.: 9 CFM I N -Wall-13A-4ocs 19 X 11 161 0.143 4.3 691 2.2 0 352 1 N -GIs-lA-cm-o shgc-0.75 100%S 48 1.270 38.1 1,828 34.8 0 1,672 1 (2) I UP-Ceil-16DR-30 25.1 X 19.3 484.4 0.032 1.0 465 1.0 0 465 Floor-22A-ph 19 ft..Per. 19 1.358 40.7 774 0.0 0 0 Subtotals for Structure: 3,758 0 2,489 ' Infil.: Win.: 17.8, Sum.: 9.4 209 2.813 588 0.742 389 155 Room Totals: 4,346 389 21644 j 0 f Rhvac.- Residbntial & Light Commercial HVAC Loads Elite Software Development, Inc. j Ken Humphrey Kathy's Residence I Port Saint Lucie FL 34983 Page 34 Detailed Room Loads - Room 11 - Playroom Bath (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.5 ft. System Number: 2 Room Width: 6.2 ft. Zone Number: 2 Area: 84.0 sq.ft. Supply Air: 5 CFM Ceiling Height: 10.0 ft. Supply Air Changes.- 0.4 AC/hr Volume: 837.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 5 CFM Percent of Supply.: 5 % Runout Duct Size: 4 in. Actual Summer Vent.: 0 CFM Runout Air Velocity: 57 ft./min. Percent of Supply: 5 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 0 CFM Actual Loss: 0.004 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area -U- Htg Sen Clg Lat Sen Descri �tion - - Quantit Value -- HTM Loss HTM Gain Gain UP-Ceil-16DR-30 13.5 X 6.2 83.7 0.032 1.0 80 1.0 0 80 Floor-22A-ph 1 ft..Per. 1 1.358 40.7 41 0.0 0 0 Subtotals for Structure: 121 0 80 Infil.: Win.:- 0.0, Sum.: 0.0 -- -- _ -- 0 _ - _ 0 0 -- 0 0 -0 Room Totals: 121 0 80 Rhvac - Residential. & Light Commercial HVAC Loads Ken Humphrey Port Saint Lucie, FL 34983 Elite Software Development, Inc. Kathy's Residence 'Page 35 Detailed Room Loads - Room 12 - Play Room (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 16.7 ft. System Number: 2 Room Width: 15.0 ft. Zone Number: 2 Area: 251.0 sq.ft. Supply Air: 134 CFM Ceiling Height: I Volume: 10.0 ft. 2,505.0 cu.ft. Supply Air Changes: Required Vent.: 3.2 AC/hr 0 CFM ( Number of Registers: 1 Actual Winter Vent.: 10 CFM Runout Air: 134 CFM Percent of Supply.: 7 % I Runout Duct Size: 7 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 500 ft./min. Percent of Supply: 5 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 22 CFM Actual Loss: 0.129 in.wg./100 ft. Actual Summer Infil.: 11 CFM Item Area -U- Htg On Clg Lat Sen Descri tion Quanti Value HTM Loss HTM Gain Gain i S -Wall-13A-4ocs 16.7 X 10 E -Wall-13A-4ocs 8.7 X 10 S -GIs-IA-cb-o shgc-0.75 100%S 137 57 30 0.143 0.143 1.080 4.3 588 4.3 245 32.4 972 2.2 2.2 21.5 0 0 0 300 125 644 I (2) E -GIs-1A-cb-o shgc-0.75 99%S (2) 30 1.080 32.4 972 21.6 0 648 i UP-Ceil-16DR-30 16.7 X 15 250.5 0.032 1.0 240 1.0 0 240 Floor-22A-ph 25 ft..Per. 25 1.358 40.7 1,019 0.0 0 0 Subtotals for Structure: 4,036 0 1,957 Infil.: Win.: 21.7, Sum.: 11.4 254 2.811 _ 714 0.740 473 188 j Room Totals: i f 4,750 473 2,145 II I Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphrey Kathy's Residence Port Saint Lucie, FL 34983 Pa a 36 Detailed Room Loads - Room, 13 - Laundry (Average Load Procedure) Gen, eral Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 2 Room Width: 8.2 ft. Zone Number: 2 Area: 107.0 sq.ft. Supply Air: 121 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 6.8 AC/hr Volume: 1,066.0 cu.ft. Required Vent.: 0 CFM f Number of Registers: 1 Actual Winter Vent.: 6 CFM Runout Air: 121 CFM Percent of Supply.: 5 % i Runout Duct Size: 7 in. Actual Summer Vent.: 6 CFM Runout Air Velocity: 452 ft./min. Percent of Supply: 5 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 16 CFM Actual Loss: 0.106 in.wg./100 ft. Actual Summer Infil.: 9 CFM Item Area -U- Htg Sen Clg Lat Sen DescrL tion Quantit, Value H fM Loss HTM Gain Gain S -Wall-13A-4ocs 6 X 10 60 0.143 4.3 257 2.2 0 131 E -Wall-13A4ocs 13 X 10 94 0.143 4.3 403 2.2 0 206 E-Door-11 D 3 X 7 21 0.390 11.7 246 10.1 0 213 l E -GIs-1A-cb-o shgc-0.75 4%S 15 1.080 32.4 486 56.5 0 847 j UP-Ceil-16DR-30 13 X 8.2 106.6 0.032 1.0 102 1.0 0 102 f Floor-22A-ph 19 ft., Per. 19 1.358 40.7 774 0.0 0 0 i Subtotals for Structure: 2,268 0 1,499 1 Infil.: Win.: 16.2, Sum.: 8.5 190 2.811 534 0.742 354 141 1 _ _ _ _ _ _ _ _ 300 300 jEquipment: Room Totals: f i f I E 2,802 654 1,940 I I I i 1,Rhvac - Resitiential & Light Commercial HVAC Loads Elite Software Development, Inc. Ken Humphreydd&.Kathy's Residence ,Port Saint Lucie, FL 34983 Page 37 Detailed Room Loads - Room 14 - Kitchen (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: Room Length: 14.0 ft. System Number: Room Width: 14.0 ft. Zone Number: Area: 196.0 sq.ft. Supply Air: Ceiling Height: 10.0 ft. Supply Air Changes: Volume: 1,960.0 cu.ft. Required Vent.: Number of Registers: 1 Actual Winter Vent.: Runout Air: 157 CFM Percent of Supply.: Runout Duct Size: 7 in. Actual Summer Vent.: Runout Air Velocity: 586 ft./min. Percent of Supply: Design Loss: 0.100 in.wg./l00 ft. Actual Winter Infil.: Actual Loss: 0.177 in.wg./100 ft. Actual Summer Infil.: Item -U- Htg Sen Clg jl7escription Irea Quantity Value HTM Loss HTM E -Wall-13A-4ocs 14 X 10 126.5 0.143 4.3 543 2.2 E -GIs-IA-cb-o shgc-0.75 8%S 13.5 1.080 32.4 437 55.3 UP-Ceil-16DR-30 14 X 14 196 0.032 1.0 188 1.0 Floor-22A-ph 14 ft..Per. 14 1.358 40.7 570 0.0 _ Subtotals for Structure: 1,738 Infil.: Win.: 11.9, Sum.: 6.3 140 2.814 394 0.743 Equipment: — --- - -- — — - Room Totals: 2,132 2 2 157 CFM 4.8 AC/hr 0 CFM 4 CFM 3 % 8 CFM 5 % 12 CFM 6 CFM Lat Sen I Gain Gain 0 277 0 746 0 188 0 0 0 1,211 261 104 0 1,200 261 2,515 Rhyac - Residt'ntial & Light Commercial HVAC Loads I Ken Humphrey I Port Saint Lucie, FL 34983 Elite Software Development, Inc. Kathy's Residence Page 38 i Detailed Room Loads - Room 15 - Dining (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.0 ft. System Number: 2 Room Width: 13.3 ft. Zone Number: 2 Area: 186.0 sq.ft. Supply Air: 137 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 4.4 AC/hr Volume: 1,862.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 5 CFM Runout Air: 137 CFM Percent of Supply.: 4 % Runout Duct Size: 7 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 511 ft./min. Percent of Supply: 5 % Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 11 CFM Actual Loss: 0.136 in.wg./100 ft. Actual Summer Infil.: 6 CFM Item Area -U- Htg Sen Clg Lat Sen Descri tion auantit Value HTM Loss HTM Gain Gain E -Wall-13A-4ocs 13.3 X 10 103 0.143 4.3 442 2.2 0 225 E -GIs-IA-cb-o shgc-0.75 4%S (2) 30 1.080 32.4 972 56.5 0 1,694 UP-Ceil-16DR-30 14 X 13.3 186.2 0.032 1.0 179 1.0 0 179 Floor-22A-ph 13 ft..Per. 13 1.358 40.7 530 0.0 0 0 Subtotals for Structure: 2,123 0 2,098 Infil.: Win.: 11.3, Sum.: 6.0 133 2.812 374 0.737 248 98 Room Totals: 2,497 248 2,196. ` ;Rhvac - Residential $.Light Commercial HVAC Loads• Elite Software l3evelopment, Inc. j j Ken Humphrey -1 Kathy's Residence j 'Port Saint Lucie, FL. 34983 Page 39 1 Detailed Room Loads - Room 16 - Hobby Room (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.7 ft. System Number: 2 Room Width: 14.5 ft. Zone Number: 2 f Area: 213.0 sq.ft. Supply Air: 218 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 6.1 AC/hr Volume: 2,132.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 12 CFM 1 Runout Air: 109 CFM Percent of Supply.: 6 % Runout Duct Size: 6 in. Actual Summer Vent.: 11 CFM Runout Air Velocity: 556 ft./min. Percent of Supply: 5 % j Design Loss: 0.100 in.wg./100 ft. Actual Winter Infil.: 32 CFM Actual Loss: 0.198 in.wg./100 ft. Actual Summer Infil.: 17 CFM Item Area -U- Htg Sen Clg Lat Sen I DescriptionA uanfiit Value HTM Loss HTM Gain Gain E -Wall-13A-4ocs 14.7 X 10 117 0.143 4.3 502 2.2 0 256 1 N -Wall-13A-4ocs 11 X 10 80 0.143 4.3 343 2.2 0 175 i NW-Wall-13A-4ocs 5 X 10 50 0.143 4.3 215 2.2 0 109 W -Wall-I3A-flocs 6.7 X 10 67 0.143 4.3 287 2.2 0 147 I E -GIs-IA-cb-o shgc-0.75 4%S (2) 30 1.080 32.4 972 56.5 0 1,694 N -GIs-IA-cb-o shgc-0.75 100%S 30 1,080 32.4 972 21.5 0 644 (2) UP-Ceil-16DR-30 14.7 X 14.5 213.1 0.032 1.0 205 1.0 0 205 Floor-22A-ph 37 ft..Per. 37 1.358 40.7 1,507 0.0 0 0 Subtotals for Structure: _ 5,003 0 3,230 Infil.: Win.: 31.9, Sum.: 16.8 374 _ _ 2.813 1,052 0.741 697 277 Room Totals: I I 6,055 697 3,507 ! hrey nFL134983Light Commercial HVAG Loads 1 Elite Software Kathy's ReFs Port Sant Bence] ` System 1 Room Load Summary i Htg Htg Run Run Clg Clg Clg Air Room Area Sens Nom Duct Duet Sens Lat Nom Sys Ng Name SF Btuh CFM Size Vel Btuh Bfiuh CFM CFM —Zone 1- Ij 1 Master Suite 293 6,683 87 3-6 519 3,583 870 306 306 2 Walk In Closet 107 861 11 14 293 300 109 26 26 I3 Master Bath 159 1,940 25 1-7 533 1,671 162 143 143 4 Bedroom 2 194 1,816 24 1-6 573 1,319 174 113 113 i 5 Bedroom 3 194 1,816 24 1-6 573 1,319 174 113 113 6 Bath 3 165 1,380 18 1-5 462 739 148 63 63 _ 7 Bedroom 4 _ _ 218 5,786 75 2-5 632 2,020 675 172 172 Ventilation 923 _ 462 1,162 AED Excursion 2,416 Duct Loads _ 6,765 _ _ _ 7,166 2,097 _System 1 total 1330 27,970 264 20,994 5,571 934 934 System 1 Main Trunk Size: 12x14 in. _ Velocity: 854 ft./min Loss per 100 ft.: 0.104 in.wg �Cgolin • System Summary Cooling Sensible/Latent Sensible Latent Total Tons Slit Btuh Stuh Btuh ` Net Required: 2.21 79% / 21% 20,994 5,571 26,565 Recommended: 2.33 75% / 25% 20,994 6,998 27,992 Actual: 2.43 72% / 28% 21,100 8,100 29,200 E • ui • ment Data Heating System Cooling System ' Type: RCGJ-36A1(OR EQUIVALENT Model: UANB-030JAZ Brand: ACHIEVER 13 Efficiency: 13 SEER Sound: Capacity: 29.2K BTU Sensible Capacity: n/a 21,100 Btuh Latent Capacity: n/a 8,100 Btuh Rhvad - Residontial & Light Commercial HVAC Loads Elite Software Development, Inc. Ken'Humphrey d1ok, Kathy's Residence Port Saint Lucie, FL 34983 Page 45 System 2 Room Load Summary '� Room,�4� �"���" Area Sens Nom Duct.. Duct Sens Lat Nom S A.a.CFM -Zone 2-- 8 Foyer 96 1,549 20 1-4 631 885 149 55 55 9 Gallery Room 176 210 3 1-4 121 169 0 11 11 10 Living 484 4,346 56 1-8 471 2,644 389 165 165 11 Playroom Bath 84 121 2 1-4 57 80 0 5 5 12 Play Room 251 4,750 62 1-7 500 2,145 473 134 134 I! 13 Laundry 107 2,802 36 1-7 452 1,940 654 121 121 14 Kitchen 196 2,132 28 1-7 586 2,515 261 157 157 f 15 Dining 186 2,497 32 1-7 511 2,196 248 137 137 16 Hobby Room 213 6,055 79 2-6 556 3,507 697 218 218 Ventilation 1,649 824 2,075 Duct Loads - - 8,132 5,920 1,602 t _System_ 2 total _ _1,793 _ 34,242 318 22,826 6,548 1,001 1,001 System 2 Main Trunk Size: 12x15 in. Velocity: 856 ft./min Loss per 100 ft.: 0.100 in.wg Y �� Coong Sen"sible/Patent W":Sensible Latent Total •%rS.lit_ ,_>.Btuh,:.,,4F »_ Btuh uh; 22% Net Required: 2.45 78% / 22,826 6,548 29,374 Recommended: 2.54 75% / 25% 22,826 7,609 30,434 Actual: 2.73 74% / 26% 24,200 8,600 32,800 Heating System Cooling System jType: RCGA-36A2(OR EQUIVALENT Model: UANB-O36JAZ 1 Brand: ACHIEVER 13 Efficiency: 13 SEER Sound: Capacity: 32.8K BTU Sensible Capacity: n/a 24,200 Btuh Latent Capacity: I I n/a 8,600 Btuh