Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEi:. FORM. R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERSE „FL Owner: , "��a V\�C n C� Permit Number: Jurisdiction: FO Design Location: L, ST_LUCIE_CO_INTL County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1437.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftZ b. Frame - Wood, Exterior R=11.0 187.33 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 2 d. N/A R= ftZ 10. Ceiling Types (1446.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ftZ 6. Conditioned floor area above grade (ftZ) 1446 b. N/A R= ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 11. Ducts R ftZ 7. Windows(139.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 320 a. U-Factor: Dbl, U=0.54 99.23 ftZ SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.55 40.00 ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ftZ SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.586 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1446.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1446.00 ftZ b. Conservation features b. N/A R= ftZ None c. N/A R= ftZ 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 46.91 PASS Total Baseline Loads: 48.19 I hereby certify that the plans and specifications covered by Review of the plans and 4�E STAr this calculation are in compliance with the Florida Energy specifications covered by this 1+O 0, �''� Code. calculation indicates compliance yiiq i ;'�.•`` �' with the Florida Energy Code. nru:>>• PREPAR D BY: DATE: - Before construction is completed this building will be inspected for compliance with Section 553.908 r * k I hereby certify that this building, as designed, is in compliance Florida Statutes. COb with the Florida Energy Code. WE`D OWNER/ T: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. F11 ,� ri • 12/10/2017 5:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title:. THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner: Total Stories: 1 Block/SubDivision: # of jJnits: 1 . Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE V IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 234 1872 No 2 1 1 Yes Yes Yes 2 WIC 54 432 No 0 1 No Yes Yes 3 MASTER BATH 63 504 No 0 1 Yes Yes Yes 4 M.BATH 56 448 No 0 1 Yes Yes Yes 5 KITCHEN 172 1376 Yes 0 1 No Yes Yes 6 BATH 45 360 No 0 1 Yes Yes Yes 7 BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 526 4208 No 0 1 Yes Yes Yes 10 FOYER 50 400 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 40 ft 0 234 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 54 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 ___- 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ____ 0 1 0 5Slab-On-Grade.Edge Insulatio KITCHEN 1 ft 0 172ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ft2 ____ 0 1 0 12/10/2017 5:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 ;FLOOkS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 ---- 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 54 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 5 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0A Wood 6 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 7 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood 10 Under Attic (Vented) FOYER 30 Blown 50 ft2 0.1 Wood WALLS 9 Ornt Adjacent Space Cavity Width To Wall TypeR--Val-le Et In Height Et In Area Sheathing Framing R-1/ahle Fraction Solar Ah�,nr Below Grade% 1 N=>SE Exterior Concrete Block - Ext Ins(dEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block - Ext InsiflEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block - Ext InsBEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block - Ext InsMASTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 5 S=>NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 7 N=>SE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 8 E=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0 9 SE=>W Exterior Concrete Block - Ext InMDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0 _ 10 S=>NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0 11 S=>NW Exterior Concrete Block - Ext InsLUAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 12 N=>SE Exterior Concrete Block - Ext Ins9REAT/DIN1 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0 12/10/2017 5:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FnRM R4nri-9nl4 WALLS Orat Adjacent Cavity ity Width Height In Wall lype13 Sheathing Framing Solar Below W=>NE Exterior Concrete Block - Ext InsOREAT/DINI 4.1 21 0 8 14 N=>SE Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 15 E=>SW Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 8 16 N=>SE Exterior Frame - Wood GREAT/DINI 11 23 5 8 0 168.0 ft2 0 8.0 ft2 0 48.0 ft2 187.3 ft2 0 0 0.5 0 0 0.5 0 0 0.5 0.23 0.5 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC U-Factor SHGC Overhang Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Double Yes 2 S=>NW 5 Metal Low-E Double Yes 3 E=>SW 8 Metal Low-E Double Yes 4 N=>SE 12 Metal Low-E Double Yes 5 W=>NE 13 Metal Low-E Double Yes 0.54 0.25 0.54 0.25 0.54 0.25 0.54 0.25 0.55 0.25 32.4 ft2 1 ft 0 in 6.9 ft2 1 ft 0 in 23.2 ft2 1 ft 0 in 36.8 ft2 1 ft 0 in 40.0 ft2 10 ft 0 in 1 ft 4 in Drapes/blinds 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None Exterior 5 None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2669 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 12/10/2017 5:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftZ DUCTS / --- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 320 ftZ Attic 80 ftZ Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatinJan Feb Feb Mar Mar f Apr Apr f may rlJun X Jul May Jun I Jul X Aug Au I Se Sep [ j Oct [ ] Oct Nov Nov ki Dec Dec H Ventin Jan Feb X X Mar [X A r [ Ma Jun Jul Aug Se [X] Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/10/2017 5:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) ' DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Dbl, U=0.54 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.25 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: WYNNE DEVELOPMENT, FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftz b. Frame - Wood, Exterior R=11.0 187.33 ft 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1446.00 ftz 1446 b. N/A R= ft2 c. N/A R= ft2 Area 11. Ducts R ft2 99.23 ftz a. Sup: Attic, Ret: Attic, AH: Attic 6 320 40.00 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ft2 13. Heating systems a. Electric Heat Pump 3.586 ft. 0.250 Area 14. Hot water systems 1446.00 ft2 a. Electric ft2 b. Conservation features ft2 None 15. Credits l I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.97 Pstat 0j't]AE srgrF based on Installed Code compliant features. rrr,,,=:r•;;,ti o Builder Signature: Date: Address of New Home�-,C,,-, City/FL Zip: WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/10/2017 5:21 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 TABLE 402.4.1.1 AIR .BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT -Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities -shall be cut to fit, or narrow cavities shall be filled by insulation. that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/10/2017 5:21 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 -- wrightsoft° Project Summary Date: Entire House By: QUICK CALLS, INC. SCANNED For: THE GRAND CARLTON WY`NNNE DEVELOPMENT, FT. PIERCE, FL Notes: \ v v�`� �CV'N Ck Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF . Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 He1446 Cc % Area ft 14 Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual, air flow Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF B k 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.049 cfm/Btuh 0.50 in H2O ac up. Input = 7 kW, Output = 23009 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Rate/swing multiplier n 0.95 Equipmenf sensible load 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req, total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 1.0440. Btuh Total cooling 34800 Btuh Actual air flow 1160. cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in W20 Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2017-Apr-11 09:29:38 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wrightsoft° Right,4@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946-Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM .2 Exposed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction number U-value (Btuh/ft2L-°F) Or HTM (Btu 2) Area (ft2) or perimeter (ft) Load (Btuh). Area (ft2) or perimeter (ft) Load (Btuh) . Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 13A4ads. 4A5r2om 0;143 0:770 n ` n" 4:00 21:56 455 . 1931 503 ' 38 465 0 1862 815 1184 . 730 .: '72 0 72. D 288 ;U 183 0 13A-4ocs 0.143 a 4.00 2.55 128 83 333. 212 0 0 0 0 1Ac1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 ��-�--DDD 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W _ l?/ Y-G 113AAocs 13A4ocs 1Ac1om 0.143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 34 360 7 34 353 7 136 1414 247 86 899 241 0 216 0 0 216 0 -0 866 0 0 550 0 13A4ocs IA clan ,4A5 2omi : 12C-0sw 0.143 1.270 0:770 0.091 w ' w 35.56 '21.66 2.55 2.55 55.21 19:31 1.28 310 32 41:. 192 2 2 41 192 9 1140 880 489 603 1770 :. 788 246 104 32 0- 0 2 0 288 1140 0 183' 177.0. 0 0 P C . 16A30md 01032 0:9'0 . 2.32 1446 :1446 1295 .: 3354 - ... 297.' : 297 ' .. ' 266 ` : Wg F 22A tpl 0.9n - 27.69 0.00 1446 156 4325 0 297 49 .1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 6 1380 3 .690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49 0 5654 8536 320% 49% 1601 2400 Total room load 23503 26056 6653 7325 Air required (cfm) 1160 1160 328 326 to meet all . P. -F+ wrightsOit- Right -Suite® Universal 2017 17.0.14 RSUD8101 ...uick Calcs%Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N 2017-Apr-11 06:29:38 Page 1 Ot m N G) n o 0 0 C. 0 ;u y o=13 ?° o � N 2g O V = d4 D Z n n �A D 0 �� 3 O CD o oEP (p � N .. Z - m UfA WN> �-i pUl�7rr ^o'B�'- fA .�+• 3 Q� 6n 7 C W.., 333Yn3 c� ���.61ZS 0 Eu eL �5 0 $ D m ch Ng ;� g 5r pp��ppo��4ol10o �o-�ao o.oii c H .qpp fop-�,opA OW.W OO WOt; TN . i �. $�,N (A CD CD fD CD7'O O ppA ppA - - '. ..• ':f000(W71,W �O'�00 N6�1007._O' r .. .. .' .. 0o gi (n AA000000000000� 3' O O 0 o - - - O Att�� O 0 0 0 0 0 0 00 000 C x O _G .T, rn&000 oo O 00000CIO 0000O T rcT ODA V VO00 V 00 00 V -t0 'O .tl7N "00�O:0 000 00 OCO O _ '• N 00 003� JG) (� O O x c o -ON'AC0000000000. - _ x O (i SOD pV000 .V 00. V O0.0000000'O. �c x 8 � N N-+000 N � w A O 00 O .20O600000 00;0 - L K d OP m.. - wrightsoft' Right-M Worksheet Job: Entire House Date: By: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM 1 Room name BATH BEDROOM 2 . 2 Exposed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ftz 1.0 x 203.5 ft 203.5 ft' Ty Construction number U-value (Btuh/ftk-°F) Or HTM (Btu Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter. (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 VN L- .G 13A flocs- - 4A5 0:143 0.770 n n 4[00 21.56 2;55 .. 19.31 - 40 0 ` . 40 _ � -0 160 ,_ 0 102 0 128 . 0 -. : =128 � -0. , :513 -0 326; 0 1N-G 13A4ocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143 11 1Aclom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 L-D W Val L-�G 13A4ocs 13A-4ocs 1Ac1om 0.143 0.143 1.270 se s s .4.00 4.00 35.56 2.55 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 34 32 0 34 W 0 136 128 0 86 81 0 13A�Iocs 1Ac1om .0.143 1:276 w .w 4.00 35.56 2.55 55.21. 0 0 0 0 0 0; .0 D 0 0 0. 0• 0. 0 0 0 P 4A52om'. 12C Osw 0.770 0.091 'w. - .2156 2.55 . 19:31 1.28 0 0 0.. 0 6 0 0 0 0 0 . "0= 0 .0 0 0' 0 C _ 16A30md:-._ 0032. - 0.90: 2.32 45. - 45 40:.. 104_.;. 204 .-204. .;.A82 -. .472 _ F 22A tpl 0.989 - 27.69 0.00 45 5 138 6 204 34 9.46 0 1. ., . 6 c)AED erxursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal Qines 6 to 13) 425 214 3571 3498 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 32% 49% 1131 1704 Total room load 560 318 4702 5203 Air required (cfm) .28 141 232 232 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. GA 41- wrightsoft• 2017-Apr-11 09:29:38 Right -Suite@ Universal 2017 17.0.14 RSUD8101 Page ...ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wrightsoft- RighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@/AOL.COM 1 Room name LAUNDRY GREAT/DINING • 2 6gwsed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ftZ Ty Construction number U-value (BtuWft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross WKS Heat Cool 6 yJ 13A4-ocs 0143 n ` 400: -255, , 0 0 0 0 :; •' 255 :: ° 217 869 552 L-G. `4A5 tom ' = 13A-4ocs 0.7.0 0.143 ri a 21;56 4.00 19.31 2.55 0 0 U 0 0 0 0 0 38 0 - 0 0 815 0 730 0 11 1Ac1om 11D0 1AAA= 13A4ocs 1Ac1om 1.270 0.390 0143 0.143 1.270 a a se s s 35.56 10.92 4.00 4.00 35.56 87.29 11.31 2.55 2.55 34.77 0 0 0 48 0 0 0 0 48 0 0 0 0 192 0 0 0 0 122 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 G L-D W, V�/ L -6 13A-46cs 1A-c1om. 4A5 2amr 12C-Osw 0143 1.270 .0.770 0.091 " w w , w - 4.00 35.56 .21.56 2.55 2.55 55.21 . 19.31 1.28. 0 0 0 56 0 0 . 0. 56 0 0. ."0 143 0 .0 0 _ 72 206 0 41 0. ' 165 q' 41 0 66f 0 < :..880 0 420 0 . :788 0 P C 16A-30iitd.. ` 0.032 : - -:0.90 2.3.2 - ' 42 42 `" 38 _ 97 - 526 526 : 471 . • 1220' F 22A tpl 0.989 - 27.69 0.00 42 6 166 0 526. 47 1302 0 6 c)AED excursion -22 668 Envelope loss/gain 539 276 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 - 5994 5112 15 Duct loads 32% 49% 204 145 32a/a 49% 1899 2490 Total room load 846 443 7892 7602 Air required (cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A -Fl:,- wrightsoft- 2017-Apr-11 09:29:38 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N - - wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: QUICKCALCS ,AOL.COM 1 Room name FOYER M. BATH 2 F�osed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool &0 ft heat/cool 4 5 Room dimensions Room area .1.0 x 50.0 ft 50.0 ftz 7.0 x 8.0 ft 56.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ft2L.°F) (Btuh/ftz) or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0ocs- 4A5 2om.. ... -.0.143 0.770 ri.' . 6 : :4.00 . 21:w.19.31, 95,57 , 8 -'0 . • 8 0 32 Q 20 :0 .: 0 0'. . 0 .0. 0 •:0 13A-4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 11 1A-c1om 11D0 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 W i VJ>/ �G .13A-4ocs 13AAocs 1Ac1om 13A flocs 12C-0sw, 0.143 0.143 1.270 .0.143 1.270 0:770 0.091 se s s w ' w. .:w' - 4.00 4.00 35.56 4.00 35.56 . 21.56 2.56 2:55 2.55 34.77 2.55 55.21 . 19;3t 1:28 0 0 0 0 0 0 72 0 0 0 0 0 . 0- 72 0 0 0 0 0 0 183 0 0 0 0 - .0- . .0: 92 0 64 7 0 - 0 0 0 0 57 7 0 0 0 0 0: 228 247 :0 0 : - 0 0 0 145 241 0 0 . 0 0 P. C : , , 30M . 0.'032 - - • -0.90 .: 2 32 50 50 45 ;:. 116 ... 56 56 50 130 F 22Mtpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 0 6 c) AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a)Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 1885 . 516 Less extemal•load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 151 Duct loads 1 32% 49% 289 258 32% 49% 280 251 Total room load 1202 787 1166 768 Air required (cfm) 59 35 58 34 Calculations approved by ACCA to meet all requirements of Manual .J 8th Ed. .�A -�- wcightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr0 Page 5 ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N -�+ wrightsoft Duct -System Summary Date: House By: QUICK CALCS,INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM ii-roject intormation For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual 'air flow Total effective length (TEL) Heating. 0.50 in H2O 0 in H2O 0.50 .in H2O 0.260 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0:360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox0 VIFx 17.0 115.0 SO LAUNDRY h 846 42 20 0.361 4.0 Ox0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 OxO VIFx 0 0 WIC c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinIFIX �Wri htSOft' 2017-Apr-1109:29:38 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door feces: N 9 Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm). Diam . (in) H x W (in) Stud/joist Opening (in). Duct Matl Trunk rb1 NO 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft@ 2017-Apr-II 09:29:38 9 Right -Suite® Universal 2017 17.0:14 RSU08101 Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N