4 SLOPE
8'-I" T.O.B.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651,12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.51,
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
ed with min.
s and 9" end
Ipaceds9" o.clWateallrlapsoandetwastaglt underlagment geredpsrows12tho.c�SlaFfieldhaAttaich 1HESE dAP)�r`JaMppSt�}
deck to trusses using attachment detail on i this sheet JSJO tlPg
Alk
40oki ►CL1 A 1 N �P,9ER� CO�Ei
h4 6 1 fW W. APP�Ir
411
O!
5'/8" thick light textured
F(D I stucco on typical concrete
block construction
0'-0" = Finished Floor
5/8" thick x 8"w cut
coral flnlshed stucco bands
LE1=7 ELEVA71ON
SCALE: 1/4' = P-O"
Gulf Coast Supply and MFG 5v Crimp Metal roofingg FL 411651.12
26 ga. 5v crimp metal rooring attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with mina 4' aide laps and V end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
ALL MANUFACTURES IABIFS SHOWING
U FACTORS AND SHGC COMPLIANCE
WITH FBC ENERGY CODE MUST
REMAIN Ut,ML INSPECT ONS ARE APPROVED
S
V
5/8" thick x 8"w cL
coral flnlshed stucco banc
Finish Columns with
5/8" thick cut coral
finished stucco bands
ELEVATION NCT�=S:
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. Sv crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps end with 1.25" ring shank nails
VI I b4&Hfi."UI i.Vlll"1 61111-A 1-ul. t"Vl Gi
block construction finished stucco bands
REAR ELEVATiON
- Overhangs at 1'-O" unless otherwise noted on Roof Plan
- Roof pitch dt 4:12 unless otherwise noted
- Any changes to this plan shall be Submitted to the architect
for approval in writing prior to starting construction.
- Return ALL Stucco Bands into Window or Door.
�, t12
SLOPE 14 ` r": S(`NfA
n., RfSP^ S0841T
1 i�`RQyr40
OR0,0 O' '/ f$
2'
W-1" T.O.B. H. .
12" 5/8" thick x 8% cut 2°
I.H. coral finished stucco bands .
,. F7.
;3 3
THESE PLANS AND ALL PROPOSED WORK 5/8" thick x 8"w cut
�5/8" thick fight textured ARE SUBJECT TO ANY CORRECTIONS coral finished stucco bands
stucco on typical concrete MAYREQBENECESIRED BY ARYINORDERELD INSPECTORS THAT
block construction MAYSSARYINORDERTO
CommPkY WITH Akk AneN�Lf OOGKOe
----------------------------------------------__,.--------------- 0'-0" = Finished Floor Finish Columns with
5/8" thick cut coral
finished stucco bands
RIGHT ELE\/AT10 I
SCALE: 1/4" = 1'-0'
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows dr Skylights
Opening
Type
NOA/FL
NUMBER
Model #
Manufacturer
Glass
Attachment method
TESProduct u'ati
Da a
n
Design Pressure
of Approved Tests
1,2,3
44
FL# 11499.2
Single Hung
Series 186
Mi Windows
and doors
1 . x t(pcona qq m1qq p7natLeUon at meetx
rom sac corner and L o.c. tharaarter throng PT Buck into =a
filled CMU wall maintaining adn 2.5" edge diets xe In strict adherence
to the product approval
+ 60 of
p
A
I6-0330.02
Overhead
Garage Door
Model 824/811
9'-4" max width
16'-O" max height
DAB
}Ina x W cAIC « uI mt
a us bar vwt sane 3/r x 6• Wilt, HLC suave eneha s n e' sic
nsi n s/due" s3e'ftim'ek.�.a kf win Tech 6rxukat t"m�mn
alas of Is adsa dsemxe - Gar to arictiy adhxa w product spprwili
f Id. Vie• eeellar an raw worts.
10-9-21
+ 50.0/-60.0 sf
p
B
FL# 16614.1
Fiberglass
Desi Pro/
Smootnh Pro
Jeld-Wen
Elco i/4' dia. tapcon with min 1.25" embedment at 3" max
from corners and 11.5" o.c. max thereafter in head and jamb&
+ 50.0 PSF
C
FL# 15332.2
SlidingGlass
Door
Series 420
Mi. Windows
and doors
x eons a Mil Denetretr" at max.
PT Be°ucck Inc c ssohd fdledp CMUaweld�mamtraw
mnghmm 2t5' edge gdutence
to strict adherence to the product approval.
r
+ 48.2 PSF
-
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
ExSpuatiom
Date
Design Pressure
of Approved Tests
Mullions
FL# 15353.8
CM-IBS31
vertical mullion
Mi Windows
and doors
For CMU use (2) 1/4' x 2 3/4" tapeoris with min 11/4" embedment
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
self tapping screws per chp as shown in product approval.
+ 118.9 PSF
_
Roof
FL# 11651.12
5Y Crimp
Metal Roofin g
Gulf Coast Supply
and manufacturing
2L ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5"
wood screws with self sealing washer at 12' o.c. max spacing over ASTM D
(type 2) 30 16 felt underlayment installed with min. 4' side laps and V and
laps fastened with corrosion resistant tin ceps and with 1.25" ring shank nails
spaced L" o.c. at all laps and two staggered rows 12' o.c. in field. Attach
deck to trusses using attachment darted on roof plan
- 108.5 PSF
Siding
stucco on Block
Soffit
FL# 12198.3
Model T4 12" vented
Vinyl Soffit
Kaycan
Install using 2" x 2" battens at 6" o.c. screwed to soffit framing using
98 x 3" wood screws at each truss. Install soffit to battens using
.12" die. x I. Iona ring shank nails with / i
+55.0/-35.0 PSF
Hurricane
Panels
Flu 15016.2
24 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2" o.c.
along the bottom and 13" o.c. at the top
± 45,0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record )
MANUrAr"9'RES LNBLES SHOWING
FACT(** `•i AND SHGC COMPLIANCE
W(Yti 1--Pr- 1=NFRGY CODE MUST
AWN ON .ALL a aOORS AND WINDOWS
N7ll, INSMTONS ARE APPROVED
2" x 4" top plate 11
1/2" drywall ceiling on truss bottom cord
1/2" drywall on
2" x 4" studs at 16" o.c.
base -board 11 II / 2" x 4" P.T. bottom plate
SCALE: 1/4" = i'-O"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 Ib felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one lager of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plgwood nailed at 6" o.c,
in field and edges with IOd ring shank galvanized
nails into truss webbing,
12
SLOPE 4
5/8" thick light textured
stucco on typical concrete
block construction
FRONT ELE\/ATi0N
SCALE: 1/4" = 1'-0'
ST. LUcIE COUNTY BUR ING DIVISION
REVIEWED FOR CO LI NCE
REVIEWED Bx
DATE__ 91 Z�TF-
SITE OR NO INSPECTION(S) WILL BE MADE
\ 4" concrete slab with fibermesh OR
6"xb" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated
fill
nterior Non -Bearing Partition
nts
Braden t
Braden AI A, FA
Wynne
Building Corp.
Architects
- Planners
-
BFax
S.E. Coconut Avenue
The
G r a r d C a r l t
Tel el
(ill) 28-1-8258
O r
E-mail:
(112) 281-8283
Spanish
Lakes
Stuart. FL
bradenaia8comcast.net
34996 #AACOOOOS2
St. Lucie Countg Florida
5/8" thick x 8"w cut
coral finished stucco bands
-0'-4" A.F
FILE CIl`I
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND :DILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: 145 mph ultimate
Mean Roof Height: I'-0' Roof Pitch: 4.12
Internal Pressure Coefficient: ±II
SubJectahilitg to damage from: Weathering: Negligible Termites: Vern Heavu
Width of Roof End Zone: 3'-4" Wind Speed: 145 mph ultimate
Wind Exposure Classification. C
Adjustment factor for Exposure Height: 1.21 x 0.4 = 0.126 ASD desiggn
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+OAWL; 0.6DL+0.4I
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.6/-32.6 psf
Roof Zone: 2. +20.6/-51.0 psf
Roof Zone: 3. +20.6/-84.0 psf
Components t Cladding Wall End Zone Width: 3'_4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4.+35.8/-38.1 psf
Wall Zone: 5. +35.8/-41.8 psf
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 Par
Shear Wags Considered for Structure? Yes
Continuous Load Path Provided? es
Are Components an Cladding Details Provided? Yes
Minimum Sal Bearing Pressure:2,500 psi, Presumptive: X By Teat: psi
This Building Shall Have the Following:
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: B1 psf ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: -AS- par FLOOR DEAD LOAD• 10 pal
JOB ADDRESS: \"' QT e CDCAN'11; L�
MODEL: Date Drawn Revisions
5-9-I1
GARAGE Drawn by:
RIGHT C.II
Checked by:
D.R.B.
TO '. PITCH
= Roof Zone I
Walls Zone 4
EM = Roof Zone 2
Walls Zone 5
END ZONE
= Corner Zones
Roof Zone 3
Sheet Comm #
1. 12-27
OF 5
"FLOOR PLAN CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = i'-0" N.T.S.
36" high by 4" diameter
I. Contractor to verify ALL notes and dimensions prior to steel crash post. Floor
proceeding with work. Flange with 4 - 2. Contractor to STRICTLY enforce ALL OSHA Requirements. sllabab (3ion bolts into
(3/8"t 50 ksi steel plate)
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
I I t t 11
4.
S.
No dissiml ar meta s O
ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
o '°
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
3/a
6.
Drywall at ceilings shall be leveled and attached to bottom chord
1.
of trusses With Screws per FBC R702.3.5.
ALL wood in contact with concrete shall be pressure treated.
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10.
Contractor to Provide Drain at water heater in accordance
Fill
with the current edition of the Florida Plumbing Code.
11.
Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
�21' 41, 1%2"
12.
Lowest finished floor to be set by Governing Building Department
surveyor to set in field.
13,
Separation between residence and garage shall be per FBC R302.6
14.
Door between garage and residence shall be 1-3/4"t 20 min. rated door
Water Heater
15.
Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC
R302.9I.1
16.
Wall and ceiling finishes shall have a smoke -developed index of not greater than 450 per
FBC R302.9.2
11.
All exposed attic insulation materials installed on attic floors shall have a critical radiant
I" x 6" PT. Buck nai
flux not less than 0.12 watt per square centimeter_ Exposed foam plastic insulation
block with {case harder
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior to door attachme
18.
with F.B.C. R316 - see permit info box of code edition
Gyypsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931
C40, C1002, C1041,C11-11, CII-18, C1218, C1395, or C1396 and shall be installed
according to the following: (FBC R-102.3.5)
Drywall
Thickness
Location
Orientation
Framing
Member
Spacing
Maximum
Max. spacing
of fasteners
Nail sizingoptions for
installation of dryywall into
wood framing membera
2" x min, thickness
Nails
Screws
�2
Ceiling
Perpendicular
24"
T,
12"
13ga 1 3/8" lloong with 19/64" head
O
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
OR
0.080" dia, xx 1 5/8" long with
15/64" head R
Walls
Either
Direction
161.
g"
I6°
Ggpsum board nail 0.086" dis.
x 15/8 with 9/32" head.
Ceiling
Perpendicular
24"
1"
12"
13ga 1 5/8" log with 19/64" head
OR
0.098" diameter x 1 3/8" long
annular -ringed or bd cooler nail
e
OR
0.092" dial xx 1 1/8" long with
I/4" head
OR
Walls
Either
Direction
161,
g"
16"
Gypsum board nail 0.0915" dia.
X 11/8" with 19/44" head.
0
2
0 0
to Masonry Beam
nails
Install SGD thru buck into Q lu
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product arc
19. ALL ceramic tile surfaces installed shall conform to ASTM 4108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A13-1.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR CII-18 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanying smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84.
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 14"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and 6 end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6"
O.C. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane
(10) ld x 1 1/2cnais 12
( 24" o.c.) supportirig Max. 4
1810lbs. uplift
Aluminum Tl
Edge d Fascia 7
2" x 6" Sub -Fascia
Kaycan full o vent vingl soffit installer
using 1/8' dia shank x 1.50 long gals,
roofing nails with 3/S" dia. head per
product approval - see chart sheet al
5/8" thick light textured
stucco on typical concrete
block construction
#5 bar vert. w/
SO" overlap
at each filled cell
Wood
Grade
' IEEE lI M
-IIII,,,,IIIII�III 11,14%111-III -
TYFICAL SECTiON
PRE-ENGINEERED TRUSSES
at 24"o.c. TYPICAL
(shop drawings by manufacturer)
yR-30 blown fiberglass
in bottom chord of trusses
-1/2" drywall with smooth finish
Two rows of beam block filled with concrete
_and (l) #5 bar Cont. in each row. Substitute
precast lintel filled with concrete and (l) #5
bar cost. for bottom row over openings
1/2" drywall over I" x furringg
strips at 14" o.c. with R4.1 'Moil
-insulation on typical 8" Block walls
All drywall to be installed per FBC R-102.3.1
and shall meet all pertaining ASTM codes.
Mortar to be Type "M" onlg proportioned per FBC R60�.1
and Mortar Jonts shall comply with Or P401.2.1.
Provide Our-O-Rock at all wet areas (ill showers, tubs etc...)
Fill cell with concrete and
(1) 45 bar vert. (typical).
-Max, spacing shall not exceed
48" unless otherwise noted
see foundation plan notes for
spacing at openings
4" concrete slab with fibermesh OR
ill #10/lo WWM on 6 mil Visqueen over
/ clean compacted termite treated fill
���11111= il;i-
14" x 14" Concrete footing
with (2) #5 bars cant. and #5
transverse bars at 48" o.c.
AREA CALCULATIONS
Living A/C = 1446 sq. ft.
Front Porch = 141 sq. ft.
Rear Porch = 200 sq. ft.
Garage = 321 sq. ft.
Total Under Roof= 2108 sq. ft.
Total Cubic Ft = 11,568
2" VTR
JIL
I
I
I
I
21` VTR
Master r�� J;L
Bath I
I 2.
I
Lav,
1
2' LrI
Lay.
4"1 2' VTR
3`
I i
2- 3'
Shwr.
Kit. Sink I
I
Kitchen 2 I
I
Lay..4
3"
W.C.
Bath #2
Shwr.T
o septic
RLUMBING RISER
1" x 6" P.T. Buck nailed to
block with case hardened nails
Head prior to door attachment
fixed door
sliding door
_ Masonry Wall
Bottom Track Typical Flooring
IM-
Sill Install SGD thru buck into
block with 3/14" tap -con with
S l I d I n g D cor D e t all I I/2" penetration at ." max.
from each corner and 20." o.c, max
thereafter at Jambs per product approval Jamb
,:At Masonry Wall NTS
Window
Schedule
Mark
1
SIZ4
Rough Open.
Window Description
PRESSURE ZONE
I.
4'-5%a"x
-3%'
54%'x 63i4°
Single Hung
ZONE 4
2,
6'-2%s"x
'-3%s"
'15" x 43!o14'
Single Hung
ZONE 4
3
2'-2" x
'-2 1/2"
2-1 '2"x 385'a'
Single Hung
ZONE 4
4.
4'-5%"x 4'-2%a"
54%"x 54%"
Single Hung
I
ZONE 4
ALL
Windolls to be aluminum
windows w/ tint
and mullio s per
elevations.
ALL
windo s to withstand
pressures in permit info box on
sheet i
ALL windows in bathrooms to
be tempered
All
rough opening
dimensions
to be verified by contractor
with
manufacturer s specs prior to construction
Door Schedule
Mark
Size
Rough O ening
Door Description
PRESSURE ZONE
A
9'-0" Xi T-O"
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X4 6'-8"
41'/4"x 83%+'
Fiberglass Panel - Inswing
ZONE 4
C
6'-0" X 6'-8"
14" x 81 %;' a; ;wt°"
Sliding Glass Door
ZONE 4
D
2'-0" x C-8"
Solid Core - Wood
- 6-Panel -Bi-Fold
Finished 24" x 81'/2"
E
2'-4" XI C-8"
Solid Core - Wood
- 6-Panel
F
5'-0" X 6`81"
Solid Core - Wood
- 6-Panel - Bi-Fold
G
2'-8" x 4'-8" x 1 %'
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X it
Solid Core - Wood
- 6-Panel
J
2'-6" X' 6'-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
K
2'-8" X
C-8"
Solid Core - Wood
- 6-Panel - Bi-Fold
ALL Ext
box on shiet
GARAGED
WITHSTAND
All rough
anu with mfacturer
rior doors to withstand pressures stated in permit info
41
OR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
opening dimensions to be verified by contractor
s Specs prior to construction
.�..
"% - -1 ---
A " - - J --- A
a
8' -6"
1'4'-O"
" o0 00 00 00
-
EGRESS
12" x 12" concrete column block filled
with concrete and (2) #7 bars vert. tied
0
Into lintels above
o
Q
Covered Porch
12'-8"
O
O
o (V
0° Oo Oo Oo o " o Ill
MASTER
"
I BEDROOM
8'-0" to 9'- " A.F.F.
Ud)
Un93
to
Vaulted edmg
c
Flat CeIII
u)
GR ATCD
o
RgOM
O i
(V
Rod
6,Shelf 4
Vanity to lie
34 Y2"high
N
vi
ry I I
H.B.
I r
°
L SET o
8'-0" to 9'-8" A.F.I qi 2" x 6" knee -wall $
below counter top QL O
Vaulted Ceiling I I imr, r
DINING
ROOMa L LINEN
I b F e Rod Shelf ABINET
O al) O
Q
O
,;.'
Vanity be I BAT
o
to i , o °
IL
34 i2 „ high I
�
N°
°
II'-O 3/4 9y4„ I
High Wall
O
N
�
I O
KIITCHEN
I � -
- _
Vent C
throug
ryer
wall
Uverr g 8'-0" A.F.F.
o N
" Flat Ceding 0-
1 V 11 11
O Upper cabinets to
extend over Ref. -
FI
1 I
" filler
ATH _ ca R.�. �
- Mm
4,_0„
vlr a
O _ Rod _E_Shelf
6 �) _ ry ® N -II Bette aulatian
I
4"m Steil Ballard
I
I�
sift€ detai Qn this sheet
IB
N
I
O Q 3 Attic Aces" Provide auto
_IFwth light 1 closer
e'-0 A.F.F. AL 2"
S
RUc
Flat Ceding
t„ IS
�Do
-L" L, o„ 4„ m
Panelp
Met er
elm�N
SECOND © a
m
BEDROOM E ERGEN
Y GARAGE
GRESS
(](] lMT I OO 8'-4" A.F.F. O
cn
Flat Ceding
I O
°
O O° N
N
®
o
EGRESS r-----------------�
O
° Block wall in
garage to be
r
1
l struck block
3'-I" O O I I
O
COVERED I I
12" x 12" contra a column block filled
ith concrete and (2) #1 bars vert. tied FORCH
Ln
Into II tels above I
6' 2" I
IrAI
I I
O O
(V
o
ONE
4'-2"
2'-8"
1 2'-8"
3'-5" 9'-0" 3'-5"
5'-4"
e �
IS'-10"
3'-4"
�1 '
C
� �J'
34'-O" FILE Ili .
Install windows thru buck into
block with 3/IL" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at ,Iambs and 20" o.c. max.
Exterior race at head and sill per product approval
of wall ---\ / \ Buck to be I" x 4" PT
�__ Ioc P.T. Buck Waded to
dock with case hardened Wads
Detail at Windows prior to window attachment
NTS
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
SILL BLOCK PRIOR TO BUCK
INSTALLATION
Attach buck to block wall with
1/4" dia. Elco conc screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2" x 6" PT Buck
of wall - / \
Detail at Door
#8 Wood screws thru jamb into buck
at each hinge and 15" o.c. max and
prior to door attachment
NTS
Scale : 1/2" = 1'-0"
.ZaI-n11
STRJCTUR
AL
NOTES:
I.
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
9.
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2•
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSi AT 28 DAYS
10
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
3.
POISON SOIL AND COVER W/ L MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
11
4
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MiNIMUM_ FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
13,
MACHINE COMPACTED TO A MINIMUM OF 2500 PSI IN AREA OF
BUILDING CONSTRUCTION
6
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14.
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
is.
ATTENTION OF THE ARCHITECT.
16.
8.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
Il.
FOUND/4710N fL/4N
SLOPE ALL PORCH S ABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
DESIGN LOADS ARE S FOLLOWS:
ROOF (DL+LL) = 4l PSF
WIND VELOCITY = 7ER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-I6, 8
A-35 SPECIFICATIONS:; ALL ANCHOR TO BE A - 30-1 STEEL.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. (FASTENERS TO HAVE MIN. G185 RATING.
1. Any changes to plans must be submitted to the architect
for approval before proceeding With construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in Writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell With concrete and 1 US bar vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings upp to 5'-I1" Wide.
Provide (2) filled cells on each side of openings from 6'-O" to 9'-II"
and Provide (3) filled cells on each side of openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" o.c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey - Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel Shall be grade 60, meeting ASTM A-I6 and
A-3S specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
SCALE: 114" = I'-O"
ermite Protection for New
onstruction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatmen
area shall be re -treated with a chemical soil treatment
in luding spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established by the Florida Department of Agriculture and
consumer services.
P otective sleeves around metallic piping penetrating
c ncrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar vert. w/
Thicken edge to 8"x8"
30" overlap
SEE TYPICAL
with concrete and
4" concrete slab ith flbermesh OR
at each filled cell
ECTIONS
one 45 bar continuous d"xL" 410/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
4" concrete slab with fibermesh OR
GRADE
b"xb" #10/10 WWM on 10 mil Vlsqueen over
clean compacted termite treated fill
Grade
PORCH SLAB EDGE DETAIL
=(III
III (III_ oo x 1wit concrete monolithic
footing with (2) #5 gars Cont.
f
SCALE 'I/2" = I'-O"
14"
#5 bar vert. w/
TYPICAL FOOTING DETAIL
3O" overlap
SCALE 1/2" = 1'-O"
at each filled cell
SEE TYPICAL
�ECTIONS
4" concrete
slab with fibermesh OR
Adjust curb height
6"x6" 410/10
WWM on 10 mil Visqueen over
based on gar. floor
4" concrete slab with fibermesh OR
clean compacted termite treated fill
slope.
a"xC #10/10 wwM on 10 mil Visqueen over
#5 bar in curb
clean compacted termite treated fill
45 bar cont.
O
Step per
foundation plan
Grade
"
— E
m
_
10" (2) #5 bars cont. bottom steel
14"w x 14"d concrete monolithic
footing wit (2) #5 bars cont.
12"
14"
2 DETAIL
AT GARAGE 37EFDOWN
SCALE 1/2" = l'-O"
GARAGE
CURB DETAIL
12" x 12" concrete column
SCALE I/22" = 1'-0"
block filled with concrete
and (2) #-1 bar& vert. tied
into lintels above
Verify house slab
height in field
Top of Tooter
IL" below finished f10
1r.
A
/
6
II IIhil-
_1I
II -(III
11
,-1IIII (III-
_
30"x30"xl6" concrete
2" x 6" PT wood secured
with
—
column footing with (4)
3/8"ilia. x 6" anchor bolt
at IS" o.c.
#5 bars each Way
overhead door traqck secured to woad
""—tit -
jamb per manufactlurer's product approval
30"
Garage Door Jamb
Detail
2 COLUMN
FOOTING DETAIL
GARAGE DOOR TO WITHSTAND PRESSURES STATED �j T s
IN PERMIT INFO BOX ON
SHEET #I. SEE PRODUCT
.J
SCALE 1/2" = 1'-0"
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
Filled Cell Masonry Column With One
#5 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell ColUmn
NTS
Filled Cell Masonry Column With One
45 From Footing To Beam Each.
Conc. Fill To Be 3000 PSi
See Floor Plan For Location
Double Filled Cell Column
NTS
Braden it
Braden AIA, FA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: (172) 281-8258
Fax
: (712) 287-8283
E-mail:
bradenaia8comcast.net
Stuart. FL
34994 #AAC000032
11
c
0 0 ° ❑° 1019 i i i i i i i i OO OO
—
rilled cell under I
girder above 0 i FI I
o
—
Rear Patio/Slab
I ILI Z_to be poured separate L , I
From the house slab.
" Iry
� I❑
"
I r
I ❑ I kfo I
24"wicxel4'doxin24iL
a Coll under filled cell FI I
ffi
00 ° E)Q QM under girder bearing.
Or----- F1----- — — --=_J i❑
I �
° I Rear Patio/Slab to I
be Flush with bottom of
-
w
cV
sliding door recess. I
Slope 1/2"
Q o
N
I
u_
i I
i
I
of I
I FI I
I to
❑
I 32'-8" °
I
I
H.B.
O
I 4" concrete slab with fibermesh OR
6"x6" :410/10 WWM on 6 mil Visqueen over �O
I clean compacted termite treated fill
I
I FII
-
o
�I
I
I�
Nr
ir
I
I
� 0
FI
❑
❑
®
I
O o
�
o
of
y
�
A/c
I H. — — — — —— -
FI — — 4"4 Steel I
o
r Ballard
®filled w/ Concrete
a al I 10
#I
r
nos
�o
I v s
i s-U®
a
vN
I I N U I
I E
�
lL
o
�
f I I E `� I
r FI— a — -J I E y
❑° ❑° ❑° ❑° 4 J
I I l�
I❑ _ ❑ 'DOR
m
I
r_
r-
/ E w O
OO U ry l
oL---_—_—_
IFS Uo� I
_—_—J
"
O O O = �_
I W
00
I °E I Q-
til x
r„
r
I� F4 r O t — — — — Recess for P5 O
°--------- °" --- 00 00 Garage Door 00 00
L
3 F
6'
II'-6"
6'-2" 3'-5" 9'-01, 3,-5"
\12" x 12" concrete column block filled
with concrete and (2) #1 bars vert. tied
into lintels above
W6nne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
FILE COPE
FOOTING
SCHEDULE
Mark
Size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
0
30"
x 30" x I6"D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
F
8"W
x 8"D
THICKEN SLAB EDGE
WITH I #5 BAR CONTINUOUS
F5
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB 9 0'-0"
MODEL:
GARAGE
RIGHT
)ate Drawn Revisions
5-9-11
Drawn by:
C.C.U.
Checked by:
D.R.B.
Sheet I Comm #
3. 112-21
OF 5
ROOF: SHEETING
ATTACH>IENT DETAIL
I. Minimum Nail Size = Sd ring shank (min. 2.5" long)
2. Minimum Screw Size = 48 x 2"
3. Minimum Sheathing Thickness 19/32" COX Plywood
4. Use naps or screws based on pressure for roof stated
in permit Info box on these plans for zone 3
Ke
Area
Edge
Field
Fastener
ressure
Zone I
6"
6"
8d ring shank
45 psf
Zone 2
4"
6"
8d ring shank
ib psf
Zone 3
4e
4"
8d ring shank
84 psf
** Zone 3a
L"
6"
48 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Concrete
/ Lintel
Column
Verify with Plan
12"x 12"
Column Block
"14l Rebar
Rebar 48 Bar Dla.
Min. Overlap
to Lint&I Attachm&nt
NTS
Provide 45 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steel into continuous
beam block steel. 'iz-_
Provide Cast -Crete
8U8-OB/OT precast -_
lintel set in mortar --_-
Min. 8" Bearing
_L _ "�—
Providal #5 bar set in pre -cast
lintel into beam where length of
the opening calls for it.
ovide PT Buck
,ached per jamb
ads Into filled c,
4" Pre -cast
Sill i
Filled Cell
Provide #5 bars with min. 48 bar
diameters overlap in filled cell. Tie
filled cell steel into continuous
footer steel.
Concrete Footing
J+ r �•L. _ (see footer schedule
for exact sizes)
DETAIL AT WINDOW OPENING IN
CBS WALL Scale: 1/2" = 1'-0"
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blockineq to vert. leg of
truss with IOd x 1.5 nails at 4" o.c,
Install Simpson MGT into wall usingg
5/8" dia. threaded rod set min. I.
into wet beam and (22) IOd nails into truss
3,LOCKING DETAIL
)F-R STRAPPiNG
TER BEARING POINT
1/8" thick light textured stucco installed per
ASTM C 92L over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D 7gpe 2 felt paper using 8d nails. Substrate
to be 19/32 COX Plywood nailed at 6" ox, in field
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11151.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" ox, max spacing over ASTM D
(type 2) 30 Ib felt underlagment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two stagggered rows 12" o.c. in field. Attach
deck to trusses using attachment detall on this sheet
Additional Precast Lintel
#5 bars
°
CLEAR
Lintel
Len th
9
Bar
Length
9
Clear
Span
P
"A"
Bars
JIB,,
Bars
2,43
2'-10"
2'-8"
-6"
none
i i i i i i
3'-6"
3' -4"
2'-2"
2,3*3
none
8F8-OBAT 8F8-IB/IT BPS-IB/2T
Additional
4'-0"
3'-0"
2'-6"
2,43
none
#5 bars •••.
CLEAR ",i: '"?;`
4'-6"
4'-4"
3'-2"
2,33
none
pone Row of "H"
5 Block Above `:
5'-2"
4'-O"
2,43
none
5'-10"
5'-8"
4'-G"
2,#4
none
Precast Lintel r i. -'�
6'-41,
6'-4"
5'-4"
2,#4
none
r Additional
tt5 bars �___ y
-0"
6'-2"
2 tt5
none
BFIL-IB/IT BFIL-IB/2T
S'-4"
T-10"
T-0"
2 A5
none
NOTES:
ALL reinforcing steel is grade 60.
I. inn. coverage of stee1=1.5"
2. min. bearing required a ea. end=8"
3. standard for reinf. steel=A5TM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Window
or D
Unit
Width
Lintel
Size
Cast -Crete
Specification
Rows of
"H" Block
Above
" a
Bottom
Steel
size
Top
Steel
Size
Max
Gravity
Load
(PLF)
Max
Uplift
Load
(PLF)
Max
Lateral
Load
(PLF)
L22
2'-2"
3'-6"
BF8-OBAT
I
#5
3049
1549
1024
L31
2'-6.
T-B"
3'-1"
4'-Om
8F8-05/IT
I
#5
2561
13L3
163
L45
4'-5°
1 5'-10"
8F8-OB/IT
I
#5
1 1105
909
1 339
L50
5'-0"
L'-0
8F8-OB/IT
I
#5
1238
835
-121
LLO
6'-8.
T-0
8F8-OBAT
I
#5
1011
121
534
LBO
8'-O"
T-4"
BPS-IB/2T
I
#5
2
1 #5
152
591
512
1-90
Ill
10'-6"
8F8-8/2T
I
#5
2
#5
443
530
401
L90B
T-O"
10'-L"
BFIL-IS/2T
ONE
1
#5
2
#5
1533
1183
401
LI00
10-o"
11'-4"
are-IB/2T
1
tt5
2
#5
582
494
452
LIOOB
10'-0'
II'-4"
alli B/2T
ONE
1
#5
2
#5
13LL
1028
452
LI20
12'-O"
IV-4"
BPS-IB/2T
1
#5
2
o5
4-11
428
324
L120B
12'-0"
13'-4"
BFIL-IB/2T
ONE
1
#5
2
#5
1015
110
324
LI40
14'-O"
15'-4"
BFIL-IB/2T
ONE
1
#5
2
#5
1250
1.09
259
LILO
IV -Ow
]T-4"
8F8-IB/2T
1
#5
2
#5
300
192
194
L160B
IL'-O"
IY-4"
BFIL-IB/2T
ONE
1
#5
2
#5
950
Boo
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE,
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails -
( 24" ox.) supporting Max.
18101bs. uplift
Aluminum Drip
Edge t Fascia
12"
2" x 6" Sub-Fasci
Kaycan full o vent vingl soffit installed
using 1/8 dia shank x 15" long galv.
roofing nails with 3/8' dia. head per
product approval - see chart sheet #I
12" x 12" concrete column
block filled with concrete
and (2) 41 bars vert. tied
into lintels above
thicken edge to a"x8"
with concrete and
one #5 bar continuous
BEYOND
Top of footer
14" below finished floor
12
I
4
IIIIil
IIII—IIII ° '�.
"'lllli�lll� IIII-IIII=
1/2" thick stucco on
attached to horizonti
framing with nails or
no lees than 1-3/4°
horizontal wood framir
into vertical wood it
Aluminum Drip
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) IOd ds
at each web
/8" hi —rib lath
and vertical wood
iples to provide
metration into
and 3/4" penetration
ng members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
45 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
per foundation plan -
per foundation plan
Poured Cor
concrete b
Poured Concre ,
concrete block u
Concrete /
Manufacture
Mounted Shutter Detail
lumrnum Panel
zee per manufacturer
See Typical 5tu4 Detail
1/8' x VST wing Nut w/
appropriate washer and spacing
per mardacturer's Details \
Btud Detail
Stud w/ Die Cast Zinc NTa
Nickel Plated Wing Nut
nts
Brace Gable end
with 2" x 4" sYP 42
aft back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEERED WOOD TRUSSES
3 24"o.c. TYPICAL
( shop drawings by manufacturer )
\R-30 blown fiberglass
in bottom chord of trusses
I/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (1) #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (U #5
bar cont. for bottom row over openings
1/2" drgwall over 1" x furringg
strips at 14" O.C. with R4.1 fl-foll
insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
n Mortar to be Type "M" only proportioned�pper FBC R601.1
and Mortar joints shall coinplg with FBC R601.2.1.
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
Simpson
Hf= I A 1V
Strap
truss to
wall using Simpson
MGT with
hurricane anchor at each truss
6/8" dia.
threaded
rod with min 12"
embedment
( 24" o.c.)
supporting Max.
22)
10d nails
or in
einto truss Add
ith
blockingwto
1810
lbs. uplift ETA 20
truss
leg per detail on
this sheet
T
=
77
L90
L90
LLO
BI
BI
BI
0
i
•]'s
L90 B I
N
BI
V
LLO
N
I W
C
I
~
12
I
L BI t
W
L
Aar�)
#n'—n
III
;
2"
>—
— BI
W
in
b- .
LL, N
W o
i
I
Z
N
W
W
N
I
I
I BI L31
` ;
,,,•
L B
W
s
I
o
(
: i—
-A
E
_
_ __ _ _
_ _
6)
Gulf Coast SuppI4 and MFG 5
Crimp Metal roofing FL #11651.12
Q
woog screws wlth self sealing w
Sher at 12" o.c. max spacing over ASTM O
(type 2) 30 Ib felt underlayme
t installed with min. 4' aide laps and 6" end
Is s fastened with corrosion re
stant tin cabs and with 1.25" ringshank nails
eck to trusses using attachme
t detm on this sheet
I
r----- BI
#C
J�
Attic Access
I 1 Q
with light I SLOPE 14
BI I 1 I U up
I 1 ( P
tail
T
I
8'-0" MAX.
I
with 2" x
1
I f T S
S
8ft back
of top chc
I I
TI
I
I
n
I
Z
2"
I L
I
I
I
I
p I
I
I
1 I BI L31
1
I
I
dp I
BI I BI 1
I
1
O
BI L45
=
N
W
I
Q
Bl
EL
4 us
W
LSO on
hurrica anc
HET4
r at
2
each
trus
N p
N
BI
us
~ m
°
( c,)
suppo,ting
lax.
<r
1810
lbs. u
lift
BI
LIBI11
BI
L%
LLO
11
1 L90B
Brace Gable
4" SYP #2
nailed to be
rds using (2)
alls at each
I
FILE C0
FIII cell with concrete and
fU #5 bar vert. (typicaU.
ROOF F
%\ i
L
ppuHessnothearwll exceed
f-� �l
Wood
46X iseo n t d
see foundation plan notes for
— OVERHANGS
AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
Base
spacing at openings
4" concrete slab with esh
— ROOF PITCH
AT 4:12 UNLESS OTHERWISE NOTED ON THiS SHEET
mil Visqueen over
6"xd" #IO/10 WWM on 6 mil Vlen
- TRUSS SHOP
DRAWINGS TO BE PROVIDED BY MANUFACTURER
clean compacted termite treated fill
- ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
IIII—IIIII I I I�-I-I-�=�11 `" I—IIII=IIII, ,, I l l i—
IIIIIIIIIIIII�IIIIIIII�IIIIIIIIIIIIIIIIIIIIIIIIIINl III -
I I 14" F I
T�plcal Front porch
Scale
: 1/2" = l'—O"
Braden It
Braden AIA, FA
Architects
— Planners
411
S.E. Coconut Avenue
Tel :
(112) 281-8258
Fax
: (112) 281-8283
E—mail:
bradenaia5comcast.net
Stuart. FL
349% #AAC000032
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRiOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
WUnne Building Corp. MODEL: Date Drawn : Revisions : Sheet Comm #
5-9—I-1
The Grand Carlton GARAGE
Drawn C.C.U. . '1 12-27
Spanish Lakes Checked bg:
St. Lucie Countg Florida D.R.B. OF 5
PANEL
"All -
Poles
BR
Load
Wire
Description
circ#
circ#
Description
Wire
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
1
2
AHU
#10
3.5 kw
30
2
3
5
4
6
2
2
30
4.5 kw
#lo
40 gal. water HTR
Range
#6
12.0 kw
50
7
9
8
10
Driier
1
20
1.8 kw
1 #12
Pump
#10
5.0 kw
30
2
II
12
1
20
1.5 kw
#12
13
14
Dishwasher
#12
1.2 kw
20
1
1
20
1.5 kw
412
Microwave
is
16
Refrigerator
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
m
is
Recepts
#12
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
19
20
Recepts
#12
20
1
1
20
1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
1
1
20
0.81 kw
#12
Garage Door Opener
23
24
Recepts
#12
20
1
1
20
1.4 kw
#12
25
26
Recepts
#12
20
1
1
20
1.92 kw
#12
21
28
Recepts
#12
20
1
1
20
412
General Lighting
29
30
Recepts
#12
20
1
I
20
#12
General Lighting
g g
31
32
Recepts
412
20
1
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
20
1
1
20
#12
General Lighting
35
36
Bathroom GFI
412
20
1
1
20
#12
Smoke Detectors
31
38
General Lighting
412
20
1
1
20
#12
Bathroom GFI
39
4o
General Lighting
#12
20
1
s are
41
42
S are
PANEL "A" LOAD CALCULATION SHEET
Load Description
Qt .
Watts
Total(Watts)
.General. Lighting (3..watts sq..ft.) .....................
Small pp....A Rance Circuit(s)
..................................................
. Range.........................................................
Refrigerator .. ..............................................
Microwave
Dish Washer .................................................
Clothes. ,Washer ....... ........ ............. ...........
Clothes„Dryer................................................
Water Heater
Water..Pump..................................................
Garage Door Opener .......... I ....... „ . „ . , , .........
1135
3
5.205
2
1,500
3,000
1
12,000
12,000
1
1,200
1,200
I
1,500
1,500
I
1,200
1,200
I
1,200
1,200
I
5,000
5,000
I
4.500
4,500
1
1.800
1,800
1
810
810
Total
Watts
31,415
First 10000 Watts 5100%
1
10,000
10,000
Remainder 21,415 840%
1
O
10,966
Electric Heat or A/C 10,000 945%
1
10,000
10,000
Calculated Load
Watts
30.966
Voltage
240
Calculated Wattage Divided bg Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical S mbol Legend
S
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Eyeball Recessed
L
Pe
Push Button Switch
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
o-
1 Wall Mounted Light
=E)
JJ-- QrQ
Waterproof ground fault circuit
interrupter
PC
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
cn I
Carbon Monoxide Detector
�2
Flood Light
Q
Thermostat
®
Electrical Panel
®
Central Vac
ua
I Electrical Meter
®
Smoke Detector
M
Ceiling fan
©
Television Jack
Telephone Jack
q Disc
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
SPKR
Speaker Hook -Up
lintercom
®= JUNCTION BOX TO SUPPORT A FAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
Electric Notes.
I. Use copper wire only, no aluminum.
2. Provide and wire all required smoke detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
S. ALL bath and kitchen receptacles to be GFI protected.
6. ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RMIL02
10. A/C Refriggerant lines that are run thru slabs must be
sleeved in PVC
11. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed by a licensed electrical
contractor, the completed system shall be full operative.
13. Contractor shall pay for all fees, permits, testing, and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
16. Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years From
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
H.B.
Vent -thru---
Soffit
ATIO/SLAB
I
I
GREAT
RCOM
I
I
I
Center Registers
169 CFM on ceding fan 169 CFM
IOxIOx-1 I OXIOxI
19 -11
3,01,01
°
11=
232 CFM
I2x6x7
163 CFM
IOxlOx6
MASTER
BEDROOM
163 CFM
IOxlOx6
x12x9
B/A
ra ra
ICJ r ICJ
12x12x9 F
B/A
LOSET
iwrig
I
e8 CF-,M��-%
I
I
I
12"
I
L----
_
��
r---7
K II
153 CFM
12x12x1
I 1'f
Pfrinx-
20xQ0
F
O
i
I
T
I
I
LF
I
14" 1
I
j
I n"
22" x 54"
�
I
L-----�
Attic Access
with light
i
L
1
SECOND %
BEDROOM
1
12x12x8
B/A CJ
COVERED
PORCH
MH EC/4NIC,4L 'L/4YOUT
SCALE: 1/,4" = I'-O"
11. It is not the intent of these plans to show eUerg minor detail
of construction. The contractor shall furnish arld install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
19. The electrical system shall be completely and effectively
grounded as required bg the latest edition of the N.E.C.
20. All material shall be new and shall bear and rwriters'
labels where applicable.
21. All equipment and panel sizes shall be verified before
ordering. The contractor shall provide circuit routings to
suit the Job conditions.
22. Furnish and install all fixtures as called for n the plans
or as selected bg others.
23. All raceways and pipes placed in or through any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
24. All exposed wire below 9'-I" shall be installed in metal EMT
conduit.
25. Dryer Vents to be installed per FBC RMIS02
1:
Z
5�OA
---- Vent -tlaru
BAT Soffit
CFM
150 Amp Id k1meter
Panel
GARAGE
r----------------- i
I I
I
I I
I I
I I
I I
I I
I I
1 I
I I
1
I I
A/C disc.
15o
#2/0 Aluminum feed AMP
MCB
I " Conduit -��� PANEL
A EL
21, PVC (FP
2" rigid service FPL I Bare #6 coppe� wire
to #5 coot. Fe ar in slab
ELECTRICAL RISER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
Braden It Braden AIA, FA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (112) 281-8283
E-mail: bradenaiagcomcast.net
Stuart. FL 34994 UAAC000032
1:1111114-
Exhaust Duct
Thru Soffit -
Wire For
Front Post
Light
6' - 3"
W(gnne Building Corp.
The Grand C
Spanish Lakes
St. Lucie County Florida
PATIO/SLAB
CTRIC/4
Post Light with
I Photo cell
w o
L N
v
arlton
L:;N"
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
Install oulet
under disc.
t shown for
claritg
SCALE: 1/4" = 1'-0"
Total Attic Space = 2124 sq. ft.
Venting Ratio I/ISO = 14,1sq. ft. required
Provide A Continuous Vented Soffit
MODEL: Date Drawn Revisions
5-9-IZ
GARAGE Drawn by:
RIGHT C.C.U.
Checked by:
D.IR.B.
Sheet I Comm #
E-1 112-21
OF 5