HomeMy WebLinkAboutENERGY EFFICIENCY CODE• SCANNED FORM R405-2014 -+ �Y � LUCIE COUNTY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON 299 Builder Name: WYNNE DEVELOPMENT Street: THE CARLTON 299 Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner:-- S� Q (1J�C� Jurisdiction: Design Location: FL, Fort Pierc County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1474.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 -7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor: Sgl, U=0.54 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34,8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1473.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.42 PASS Total Baseline Loads: 48.48 I hereby certify that the plans and specifications covered by Review of the plans and O�T14E S7•A ' this calculation are in compliance with the Florida Energy specifications covered by this 1� •_ - ; Off, �'' Code. calculation indicates compliance Sri,, .= �.�� vs► With the Florida Energy Code. mu , .�• °;.. �t O PREPA D Y: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 u O°I� X * R I D I hereby certify that this building, as designed, is in compliance Florida Statutes. COD with the Florida Energy Code. _ �l W-S OWNER/ T: BUILDING OFFICIAL: DATE: DATE: �O - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 1 ' 4 fig: 1' 4/3/2017 5:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owrfer: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE CARLTON 299 Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 329 2632 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft2 _--- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ftz __-- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 _--- 0 1 0 4/3/2017 5:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 NE=>SW Exterior Concrete Block - Ext InsUIEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext Insi3EDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 NE=>SW Exterior Concrete Block - Ext InQEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext ImUDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InfiffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 _ 9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 _ 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext Inst11AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 20 0 8 0 160.0 ft2. 0 0 0.6 0 _ 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 4/3/2017 5:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 Ifi7 T"ZMOSIGi[! DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes 0.54 0.25 32.9 ft2 1 ft 0 in 1 ft 4 in 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in 0.54 0.25 24.0 ft2 6 ft 0 in 1 ft 4 in 0.54 0.25 37.5 ft2 1 ft 0 in 1 ft 4 in 0.55 0.25 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) 000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 4/3/2017 5:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ftZ Attic 85 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin [[ Heating [X] ]]Jan [[ ]]Feb Jan [X] Feb Mar Mar A r Apr Ma May Jun rj Jun Jul rj Jul Aug rj Au [X] Se [ ] SeP Oct Oct Nov Nov [ Dec [ Dec Ventin [[ ]]Jan [[ ]] Feb X Mar X [X A r Ma Jun Jul Au [ ] Se [x] Oct X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/3/2017 5:48 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON 299 Builder Name: WYNNE DEVELOPMENT Street: THE CARLTON 299 Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 4/3/2017 5:48 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE CARLTON 299, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftz b. Frame - Wood, Adjacent R=11.0 192.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area (ftz) 1474 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft z a. U-Factor: Sgl, U=0.54 101.25 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft 6 325 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Electric a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2EF: 0.97 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home:\ `�G City/FL Zip:;;:�&y O� TSE ST.gp�o� WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/3/2017 5:48 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 Project Summary at- wrightsoft p EntlireWouse By: QUICK CALCS, INC. 317 ST. LUCIE LN.; FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM For: WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL �— QQ Notes: Design Information Weather. Fort Pierce, FL, US .Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18188 Btuh Structure 17877 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh . Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23842 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25093 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality. Average Fireplaces 0 Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh Heatingg coolingg (none) Area (ft2) 1474 1474 Equipment latent load 5277 Btuh. Volume (ft3) 12227 12227 Air changes/hour 0.45 0.23 Equipment total load 30370 Btuh Equiv. AVF (cfm) 92 47 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling .Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AH RI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input _ Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47OF Latent cooling . 10440 Btuh Temperature rise 27 OF Total cooling 34800. Btuh Actual airflow 1160 cfm Actual air flow 1160 cfm Airflowfactor 0.049 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Load sensible heat ratio 0:83 Capacithermostat y ba ance point = 33 °F Backup: Input = 7 kW,: Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 2017-Apr-1017:1e I Right -Suite® Universal 2017 17.0.14 R$U08101 Page ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 Front Door faces: N -► - Wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name Entire House BEDROOM 2 2oposed wall 156.2 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heat/cool 4 5 Room dimensions Room area 1473.5 ft2 1.0 x 329.0 ft 329.0 f12 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) number (Btuh/ft2-'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A 4dcs ':1A c1om.. 0;:143 1270 ne :. . ne' 4.00 35 56. ; 255 70.43 479 ; 36 442 0 1768 1344 1124 2662 80 0 Sq 0 320, : " 0, 204' 0: 13A-4ocs 0.143 se 4.00 2.55 128 83 331 210 0 0 0 0 11 1A-c1om 11D0 1.270 0.390 se se 35.56 10.92 34.77 11.31 24 22 48 22 848 236 829 244 0 0 0 0 0 0 0 0 W .'A3A-4ocs 13AAocs 0:143 0.143 s sw 4:00 4.00 2.55 2.55 34 360 34 •353 136 1414 86 899 0 224 0 224 .' .0 897 0 570 1Ao1om 1.270 sw 35.56 42.91 7 11 247 298 0 0 0 0 13AAocs IA-clom 0.143 1.270 nw nw 4:00 35.56:. 2.55 .45.24. 2.90 - 33 .217 0 867 1162 551 " 1478 112 W3 :79. 0 318 1162T 202 1478 4A5-29m 12C-0sw :16A'30mtl 0.770 0.091 0:032 ,:nw. - - = . 21.56 2.55 :.0:90 27.54 1.28 232 . 41 192 1474 . 0 192 1474 ". 880 489 1320.'. 1124 246 3419. 0. 0 329 - 0 0 329 : •. 0 0 295. . . 0 0 763 P C F 22A-tpl, 0.989 - 27.69 0.00 1474 156 4325 0 329 52 1440 0 6 c)AED excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 2 460 Appliances/other 2000 0 Subtotal (lines 6 to 13) 18188 17877 5341 4606 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal, 18188 17877 5341 4606 15 Duct loads 31% 48% 5654 8536 31% 48% 1660 2199 Total room load 23842 26413 7001 6805 Air required (cfm) 1160 1160 341 299 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A -Fk- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 1 ...Wrightsoit WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N. - wrightsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 3 =ed wall Room height 0 ft 8.0 ft heat/cool 8.0 ft 8.0 ft heat1cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 7.0 x 8.0 ft 56.0 ftz Ty Construction number U-value (Btuh/ft'L°F) Or HTM (Btuh/ftz) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 U�/ G 13A 4acs: ; 1Ac1om 13A-4ocs 0.143 1.270. 0.143 ne.' ne se 4 00 35:56 4.00 Z55 70:43 2.55 0 ' : 0 0 : ;: .. 0 0 0 .. Q 0.' 0 ;0 0 " 0': 0 0 0 0 :;0 0 . U 0 11 1Aclom 11DO 13A-4ocs 13A-4ocs 1Aclom 13A46cs 1Ac1om ,, 4A5 tom . 12C-0sw, 16A 30md ' --. 22A tpl 1.270 0.390 0143 0.143 1.270 0.143 1.270 0:770 0.091 0.'94 0.989 se se s sw sw nw `nw . riw - ; '- - 35.56 10.92 4.00 4.00 35.56 4.00 35.56 21.'56: 2.55 0A0 27.69 34.77 11.31 2.55 2.55 42.91 2.65 45.24 27.54 1.28 . 232 0.00 0 0 0 0 0 0 0 0 0 63 63 0 0 0 0 0 0 0 : 0 0 63 0 0 0 0 0 0 0 0. 0 0_ 56 0 0 0 0 0 0 0 0 0 0 ! 146 0 0 0 0 64 7 0 0 . 0 0 56 56 0 0 0 57 5 0 0 0 0 .' . 56 8 0 0 0 228 247 0 : 0 . 0 0 50: 222 0 0 0 145 298 0 `-0. : 0 0 :..13q 0 ,W..° Vi/ VLG P C F 6 c)AED excursion -2 225 Envelope loss/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 56 145 887 836 Less a)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 836 15 Duct loads 31% 48% 18 69 31% 48% 276 399 Total room load 74 214 1162 1235 Air required (cfm) 4 9 57 54 VQIUUIQUUI IA QrdFAUVVU Uy AV V/'l LU IIIOGL Oil IGgU11Gl I IVIIla UI 1V1G11U01 VOUI CU. AA - wcightsoft' RightSuite@ Universal 2017 17.0.14 RSU08101 2017-Apr 10 1 Page 2 ...Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Doorfaces: N - wrlightsoft° Right-JO Worksheet Job: Entire House - Date: QUICK CALLS, INC. By: 317 ST, LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772486-6796 Email: QUICKCALCS@AOL.COM �1 Room name KrrCHEN BATH 2 F�gwsed wall 0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 192.0 ft 192.0 ft' 9.0 x 5.0 ft 45.0 ft2 Ty Construction number U-value Btuh/ft;°F ( ) Or HTM (Btuh/ftz) Area (ft s) or perimeter (ft) Load oa (Btuh): Area (ftt) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 ,A !. G� "I3A-0ocs -:- JA 6m , : =; 13A4ocs 0.143 1270 0.143 ne"'. ne':. se 400 35.56 4.00 .2.55 70:Q3 255 0 . 0 0 0 .. 0 0 . 0 -:. 0 0 0 - 0 0 40 ' 0'• 0 ` 40 0 0 ; 18b 0 0 '102 0 0 11 1Ac1om 11DO 1.270 0.390 se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 ���---- :1N- .::13A4ocs VV t--G 13A4ocs 1A-clom 13AAocs 1A-c1om ° 4A5-tom ; 12C-0sw - �16A3pmd .. 22A tpl 0.143. 0.143 1.270 0.143 1270 0.770 0.091 : 0.032.. 0.969 s sw sw nw - nw. nw - .. - - 4.00 4.00 35.56 4.00 35;5ti 21.56 2.55 QM'. 27.69 2.55 2.55 42.91 2.55 45:24 27.54 1.28 2.32 0.00 0 0 0 0 . 0 . 0 64 . 192 192 .0 0 0 0 0 : 0 64 192 0 0 0 0 0 0 .. 0 163 172 0 0 0 0 0 0 - . 0 82 , 445 0 0 0 0 0 0 p 0 ° 45 45 0 0 0 0 � 0 0: 0 .45 5 0 0 0 ' 0 U 0 - -40 138 0 0 0 0: 0. 0 104' 0 F C . ` F 6 c)AED excursion -27 -2 Envelope loss/gain M5 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 335 2501 426 228 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 ,0 14 Subtotal 335 2501 426 228 15 Duct loads 1 31% 48-/.l 104 1194 31% 48%1 133 109 Total room load 439 3695 559 336 Air required (cfm) ' 21 162 27 15 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. , wcightsaft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page age 3 ...Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N -r# wrightsoft Right-M Worksheet Job: Enure House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM 2 ENTRY 2 Exposed wall 32.2 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 203.5 ft 203.5 ftz 1.0 x 55.0 ft 55.0 ft2. Ty Construction U-value Or HTM Area (ftz) Load Area (ft2) Load number (Btuh/ft2--'F). (Btu 2) or perimeter (ft) (Btuh). or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 ,, 1-� W 13A-0ocs 7Ac1om`•` 13A-4ocs 0.:143 1:270 0.143 ne ne se 4.00 35.5fi 4.00 2,55 .. 70.43 2.55 ; 128 `. 0 80 128 . 0 56 513 0 225 . 326 0 143 0' • . .. 0 48 0 .. 0 26 ; 0, ,. 106 ,-;0 0 67 11 1A-c1om 11DO 1.270 0.390 se se 35.56 10.92 34.77 11.31 24 0 24 0 848 0 829 0 0 22 0 22 0 236 0 244 L�_-(p` 1/U " t-G 13A4ccs 13A4ocs 1A-c1om 0:143 0.143 1.270 s sw sw 4;00 4.00 35.56 2.55 2.55 42.91 34 16 0 34 16 0 136 64 0 86 41 0 0 8 0 0 8 0 0 32 0 0 20 0 13AAdcs 0.143 nw 4;00. 2:55 0 0 0 0 0 0 0 .0 T• 1Acllom 1.270 : nw 35.56 1 45.24 . 0 0 0 0 0- 0 0. 0 4A5-2om . 12C-Osw 0.770 0.091 nw 21.56 2.55 27.54 1.28 0 0 0 0 0 0 0 0 0 72 0. 72 0 183 6 92 P iC'��-, - �1'16A30md: = 6.032 • - • 0.901 2.32 204 204 182 . 472 '.55 .56 . 41 128 F 22AAM. 0.9.89 - 27.69 O.OD 204 32 891 0 55 7 194 al . , 0, 6 c)AED excursion -24 -6 Envelope loss/gain 2859 1873 800 545 12 a) Infiltration 564 154 122 34 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3422 2257 922 579 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3422 2257 922 579 15 Duct loads 31% 48% 1064 1078 31% 48% 287 276 Total room load 4486 3335 1209 855 Air required (cfm) 218 146 159 38 Calculations .�A fj�- wrightsoft'' RightSuite@ Universal 2017 17.0.14 RSU08101 ...Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: 2017-Apr-10 17:14:63 Page 4 - wrightsoft' Right-J® Worksheet Job: Entire House Date: By. QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 . Frosed wall 6.0 ft 46.0 ft 3 Roam height 8.0 ft heattcool 8.9 ft heat/cool 4 5 Room dimensions Room area . 7.0 x 6.0 ft 42.0 ftz 1.0 x 488.0 ft 488.0 ftz Ty Construction U-value Or HTM Area (ftz) Load Area (ftz) Load number (Btuh/ft2 °F). (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ t-C 13A-0acs :1Ac1om.1:i270 0.143 ne ne.' .; 4 00 : 35.56 ; 2.55 :° , 70.43 . .0 > 0 0 =. _ 0 0 0 , 0 0 231 38 :. • 194 0 778 . 1344 t "493 ', 2662 �1�G 13A flocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 �-D 1A-clom 11130 1.270 0.390 se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W YC :IM4 ocs: 13AAocs 0.143 0.143 s sw 4:00 4.00 255 2.55 0 48 0 48 0 192 :. 0 122 0 0 0 0 0 0 0 0 1A-c1om 13AAocs 1A�c1om 1.270 0.143 1.270 sw nw : nw 35.56 4.00 35:56' 42.91 2.55 45:24. 0 0 0 0 0 0 0 0 0 0 0 0 0 178 0 0 137 : 0 0 •549. 0; 0 349 ; 0 ;4A5.2om.' . 12C-0sw 16AOmd , .0.770 0.091 0032 nw - _ _, 21.56 2.55 0:90 27.54 1.28 . 232 0 56 42 .. 0 56 42 0 143 . 38 .0 72 : 97 . 41 0 . _ .:488 0. 0 : . 488 88Q 0 '. 437, , 1124 0 i. 1132 P C F 22A tpl 0.989 - 27.69 0.00 42 6 166 0 488 .. 46 _ 1274 0 6 c)AED excursion -3 -56 Envelope loss/gain 539 288 5259 5704 12 a) Infiltration 105 29 895 245 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 .460 Appliances/other 0 0 Subtotal (lines 6 to 13) 644 317 6164 6409 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 317 6154 6409 15 Duct loads 31% 48% 200 151 31% 48% 1913 3060 Total room load 844 468 8067 9469 Air required (cfm) 41 21 393 . 416 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. A -�- wrightsoft" Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-AprA0 1 :14:53 ...Wrightsoft WA61WYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 Front Door faces: N 9 Duct System Summary Job. wrightsoft y Date: Entire House By: QUICK CALCS,INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@A(?L.COM For: WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL External static pressure Pressure losses Available. static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O: 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name . Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 Ox0 VIFx 18.1 115.0 st1 BEDROOM h 4486 218 146 0.374 6.0 Ox0 VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 149 0.297 6.0 Ox 0 VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 Ox0 VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 Ox0 VIFx 22.4 135.0 st2 GREAT/DINING-6 c 4735 196 208 0.307 7.0 Ox0 VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 OxO VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 Ox 0 VIFx 21.6 115.0 st1 M. BATH h 1162 57 54 .0.366 4.0 Ox0 VIFx 21.6 115.0. st1 wlc c 214 4 9 0.310 4.0 Ox0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in)_ Material Trunk st2 Peak AVF 737 724 0.284- 689 14.0 0 x 0 VinlFlx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx wri htsofte 2017-Apr-1017:14:54 � 9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 1 ... Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N 11 Return Branch Detail Table Name Grille Size (in) Htg (cfm) clg (cfm) TEL (ft) Design FR Veloc (fpm). Diam (in) H x W (in) Stud/Joist, Opening (in) Duct Matl Trunk rb1 OX01 1160 1160 0 0 0 0 Ox 0 VIFx 2017-Apr-10 17:14:54 ACC ' wrightsoftg Right-SuiteN> Universal 2017 17.0.14 RSU08101 Pa e 2 9 ..Wrightsoft WACIWYNNE-THE GRAND CARLTON-M.rup Calc = MJ8 Front Door faces: N