Loading...
HomeMy WebLinkAbout0804-0166 ENERGY EFFICIENCY CODE�< FORM 60OA-2004R EnergyGauge® 4.5 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: THE DIMEO RESIDENCE Builder: SANTOS Address: Permitting Office: City,. State: HUTCHINSON ISLAND, FL Permit Number: SCANNED Owner: MR. & MRS. DIMEO Jurisdiction Number. Climate Zone: Central BY St Lucie Go -way 1. New construction or existing New _ 1.2. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit Cap: 36.0 kBtu/hr 3. Number of units, if multi -family 1 _ SEER: 13.00 _ 4. Number of Bedrooms 3 _ b. Central Unit Cap: 24.0 kBtu/hr 5. Is this a worst case? No _ SEER: 13.00 _ 6. 'Conditioned floor area (ft) 3419 W _ c. N/A 7. Glass type and area: (Label reqd. by 13-104.4.5 if not default) _ a. U-factor: Description Area 13. Heating systems (or Single or Double DEFAULT) 7a(Sngle Default) 476.0 ft' _ a. Electric Heat'Pump Cap: 36.0 kBtu/hr _ b. SHGC: HSPF: 7.70 _ (or Clear or Tint DEFAULT) 7b. (Tint) 476.0 ft? _ b. Electric Heat Pump Cap: 24.0 kBtu/hr _ 8. Floor types HSPF: 7.70 _ a. Raised Concrete R=0.0,1749.0ftz _ c. N/A b. N/A c. N/A _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 52.0 gallons _ a. Concrete, Int Insul, Exterior . R=4.1, 2600.0 ftz _ EF: 0.93 _ b. N/A _ b. N/A c. N/A d. N/A _ c. Conservation credits _ e. N/A _ (IRi 11bat recovery, Solar 10. Ceiling types _ DHP-Dedicated heat pump) a. Under Attic R=30.0,1749.0 ft- 15. HVAC credits MZ-C, PT, CF, MZ- _ b. N/A _ (CIF -Ceiling fan, CV -Cross ventilation, c. N/A _ HF-Whole house fan, 11. Ducts _ PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior Sup. R=6.0, 125.0 ft NZ-C-Multizone cooling, b. Sup: Unc. Ret: Con. AH: Interior Sup. R=6.0, 100.0 ft _ MZ-H-Multizone heating) Glass/Floor Area: 0.14 Total as -built points: 33793 PASS Total base points: 34900 C I hereby rtify that the p ns and specif ions .covered by this cal ulation are in co liance with a Florid n rgy Code. f PREPARED DATE: 11,Z " l .2o oCF- I hereby certify that is building, as es Ined, is.in compliance with the Florida Energy C 'OWNER/AGENT: DATE: Review of the plans.and specifications covered by this calculationindicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: _ ,'i Predominant glass type. For ac41aI glass tyA6 and areas; see Summer & Winter Glass output on pages 2&4. U EnergyGauge® (Version: FLRCSB v4.5) ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE SCORE* = 87.5 The higher the score, the more efficient the home. MR. & MRS. DIMEO, , HUTCHINSON ISLAND, FL, 1. New construction or existing New _ 12. Cooling systems 2. Single family or multi -family Single family _ a. Central Unit Cap: 36.0 kBtu/hr _ 3. Number of units, if multi -family 1 _ SEER: 13.00 4. Number of Bedrooms 3 _ b. Central Unit _ Cap: 24.0 kBtu/hr _ 5. Is this a worst case? No _ SEER: 13.00 6. Conditioned floor area (W). 3419 ft2 a N/A _ 7. Glass typel and area: (Label regd. by 13-104.4.5 if not default) _ a. •U-factor: Description Area 13. Heating systems. _ (or Single or Double DEFAULT) 7a(Sngle Default) 476.0 ft' _ a. Electric Heat Pump Cap: 36.0 kBtu/hr _ b. SHGC: HSPF: 7.70 (or Clear or Tint DEFAULT) 7b. (Tint) 476.0 ft' _ b. Electric Heat Pump - Cap: 24.0 kBtu/hr 8. Floor types _ HSPF: 7.70 a. Raised Concrete R=0.0, 1749.OW _ c. N/A _ b. N/A _ c. NIA _ _ 14. Hot water systems 9. Wall types a. Electric Resistance Cap: 52.0 gallons _ a. Concrete, Int Insul, Exterior R=4.1, 2600.0 W _ EF: 0.93 b. N/A _ b. N/A _ c. N/A _ d. N/A _ _ c. Conservation credits e. N/A _ (H1t Heat recovery, Solar _ 10. Ceiling types DIP -Dedicated heat pump) a. Under Attic R=30.0, 1749.0 ft2 _ 15. HVAC credits MZ-C, PT, CF, MZ- • b. N/A (CF-Ceiling fan, CV -Cross ventilation, _ c. N/A _ HF-Whole house fan, 11. Ducts PT -Programmable Thermostat, a. Sup: Con. Ret: Con. AH: Interior. Sup. R=6.0, 125.0 ft _ MZ-C-Multizone cooling, b. Sup: Unc. Ret: Con. AH: Interior Sup. R=6.0, 100.0 ft _ MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction thro the above en er saving features which will be installed (or exceeded) in this home before al inspectio erwi e, a new EPL Display Card will be completed based on installed C com e tares. lcfi_ Builder Signature: Date: f3 Address of New Home: �J �'� Pcwk L Zip: (. F, - *NOTE. The home's estimated energy performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 or greater (or 86 for a US EPA/DOE EnergyStar'mdesignation), your home may qualify for energy efficiency mortgage (EEM incentives fyou obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at www.fsec. ucf. edu for. information and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact the Department of Community Affairs at 8501487--1824. 19 Predominant glass type. For actual glass type and areas see Summer'& Winter Glass outpS�But on ages 2&4. );nergyGauge®(Version: FLRCv4.5) FORM 60OA-2004R EnergyGauge® 4.5 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS:, HUTCHINSON ISLAND, FL, PERMIT #: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 3419.0 24.35 14985.0 1.Single, Tint N 2.0 16.0 36.0 24.46 0.99 872.0 2.Single, Tint N 2.0 17.0 24.0 24.46 0.99 582.0 3.Single, Tint N 2.0 5.5 20.0 24.46 0.89 435.0 4.Single, Tint N 2.0 4.5 12.0 24.46 0.86 251.0 5.Single, Tint E 7.0 9.0 160.0 53.27 0.60 5071.0 6.Single, Tint W 7.0 10.0 40.0 47.90 0.63 1215.0 7.Single, Tint W 7.0 8.0 6.0 47.90 0.57 165.0 8.Single, Tint W 2.0 7.0 90.0 47.90 0.89 3835.0 9.Single, Tint S 2.0 15.0 32.0 39.84 0.98 1244.0 10.Single, Tint S 2.0 17.0 24.0 39.84 0.99 945.0 11.Single, Tint S 2.0 5.5 20.0 39.84 0.77 616.0 12.Single, Tint S 2.0 2.5 12.0 39.84 0.60 285.0 As -Built Total: 476.0 15516.0 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Int Insul, Exterior 4.1 2600.0 1.18 3068.0 Exterior 2600.0 ' 1.90 4940.0 Base Total: 2600.0 4940.0 As -Built Total: 2600.0 3068.0 DOOR TYPES . Area X BSPM = Points Type Area X SPM = Points Adjacent 0.0 0.00 0.0 Exterior 0.0 0.00 0.0 Base Total: 0.0 0.0 As -Built Total: 0.0 .0.0 CEILING TYPES Area X BSPM = Points Type 1 R-Value Area X SPM X SCM = Points Under Attic 1749.0 2.13 3725.4 1. Under Attic 30.0 1749.0 2.13 X 1.00 3725.4 Base Total: 1749.0 3725.4 As -Built Total: 1749.0 3726.4 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 0.0(p) 0.0 0.0 1. Raised Concrete 0.0 1749.0 1.0071749.0 Raised 1749.0 -3.43-5999.1 Total: EnergyGauge® DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 • SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:, HUTCHINSON ISLAND, FL, PERMIT #: BASE AS -BUILT' INFILTRATION Area X BSPM = Points Area X SPM = Points 3419.0 14.31 48925.9 3419.0 14.31 48925.9 Summer Base Points: 66577.2 Summer As -Built Points: 69486.3 Total Summer X System = Cooling Total X Cap X Duct X System X Credit = Cooling Points Multiplier . Points Component Ratio Multiplier Multiplier Multiplier Points (System - Points) (DM x DSM x AHU) (sys 1: Central Unit 36000btuh ,SEERIEFF(13.0) Ducts:Con(S),Con(R),Int(AH);R6.0(INS) 69486 0.60 (1.00 x 1.150 x 0.90) 0.260 0.857 9619.1 (sys 2: Central Unft 24000btuh ,SEER/EFF(13.0) Ducts:Unc(S),Con(R),Int(AH),R6.0(INS) 69486 0.40 (1.08 x 1.150 x 0.90) 0.260 0.857 6919.3 66577.2 0.3250 21637.E 1 69486.3 1.00 1.071 0.260 0.857 16694.7 EnergyGaugelm DCA Form 60OA-2004R EnergyGauge®JFIaRES'2004 FLRCSB v4.5 FORM 60OA-2004R EnergyGauge® 4.5 \ WINTER CALCULATIONS Residential Whole Building Performance Method A - Details r l ADDRESS:, HUTCHINSON ISLAND, FL, PERMIT #: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Point .18 3419.0 9.11 6606.0 '1.Single, Tint 'N 2.0 16.0. 36.0 15.38 1.00 552.0 2.Single, Tint N 2.0 17.0 24.0 15.38 1.00 368.0 3.Single, Tint N 2.0 5.5 20.0 15.38 1.00 306.0 4.Single, Tint N 2.0 4.5 12.0 15.38 0.99 183.0 5.Single, Tint E 7.0 9.0 160.0 13.04 1.12 2336.0 6.Single, Tint W 7.0 10.0 40.0 13.80 1.07 587.0 7.Single, Tint W 7.0 8.0 6.0 13.80 1.08 89.0 8.Single, Tint W 2.0 7.0 90.0 13.80 1.02 1260.0 9.Single, Tint S .2.0 15.0 32.0 10.88 1.00 347.0 10.8ingle, Tint S 2.0 17.0 24.0 10.88 0.99 259.0 11.Single, Tint S 2.0 5.5 20.0 10.88 1.14 248.0 12.Single, Tint S 2.0 2.5. 12.0 10.88 1.66 217.0 As -Built Total: 476.0 6752.0 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 0.0 0.00 0.0 1. Concrete, Int Insul, Exterior 4.1 2600.0 3.31 8593.0 Exterior 2600.0 2.00 5200.0 Base Total: 2600.0 6200.0 As -Built Total: 2600.0 8593.0 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 0.0 0.00 0.0 Exterior 0.0 0.00 0.01 Base Total: 0.0 0.0 As -Built Total: 0.0 0.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1749.0 0.64 1119.4 1. Under Attic 30.0 1749.0 0.64 X 1.00 1119.4 Base Total: 1749.0 1119.4 As -Built Total: 1749.0 1119.4 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 0.0(p) 0.0 0.0 1. Raised Concrete 0.0 1749.0 4.00 6996.0 Raised 1749.0 -0.20 ' -349.8 Base Total: .349.8 1 As -Built Total: 1749.0 6996.0 9 EnergyGauge® DCA Form 600A-2004R EnergyGauge®/RaRESTOM FLRCSB v4.5 -FORM 60OA-2004R EnergyGauge® 4.5 WINTER CALCULATIONS Residential Whole Building Performance .Method A - Details I ADDRESS:, HUTCHINSON ISLAND, FL, PERMIT #: I BASE AS -BUILT INFILTRATION Area X BWPM = Points Area X WPM = Points 3419.0 -0.28 -957.3 3419.0 -0.28 -957.3 Winter Base Points: 1061.8.2 Winter As -Built Points: 22503.0 Total Winter X System = Heating Total X Cap X Duct X System X Credit = Heating Points Multiplier Points Component Ratio Multiplier, Multiplier Multiplier Points (System - Points) (DM x DSM xAHU) (sys 1: Electric Heat Pump 36000 btuh ,EFF(7.7) Ducts:Con(S),Con(R),lnt(AH),R6.0 22503.0 0.600 (1.000 x 1.160 x 0.92) 0.443 0.902 5764.1 (sys 2: Electric Heat Pump 24000 btuh ,EFF(7.7) Ducts:Unc(S),Con(R),Int(AH),R6.0 22503.0 0.400 (1.068 x 1.160 x 0.92) 0.443 0.902 4104.0 10618.2 0.5540 5882.5 22503.0 1.00 1.099 0.443 0.902 9897.2 V _ EnergyGaugeTM' DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5 -FORM 60OA-2004R EnergyGauge® 4.5 - WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS:, HUTCHINSON ISLAND, FL, PERMIT #: I BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2460.00 7380.0 52.0 0.93 3 1.00 2433.55 1.00 7300.6 As -Built Total: 7300.6 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling + Heating + Hot Water = Total Points Points Points Points 21638 6883 7380 34900 16596 9897 7301 33793 PASS Av Q W6 EnergyGauge'*' DCA Form 60OA-2004R EnergyGauge®/FIaRES2004 FLRCSB v4.5 -FORM 60OA-2004R EnergyGauge@ 4.5 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , HUTCHINSON ISLAND, FL, PERMIT #: I 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor, around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier, gaps in gyp board & top plate; attic access. EXCEPTION:'Frame ceilings where a continuous infiltration barrier is installed that is sealed at the erimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed'inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 _Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGaugeTm DCA Form 60OA-2004R EnergyGauge®/FlaRES'2004 FLRCSB v4.5