Loading...
HomeMy WebLinkAbout0907-0243 ENERGY EFFICIENCY CODESCANNED y FORM 1100A-08 BY _''�'-.FLORIDA ENERGY EFFICIENG�' I5� R BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Performance Method A Project Name: James Allan Merrit Renovation Builder Name: Street: 804 Anita Street Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL , Permit Number. Owner. James Allan Merritt Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.2 1860.00 ftz b. Frame - Wood, Adjacent R=19.0 196.00 ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. Conditioned floor area (ftz) 2747 a. Under Attic (Vented) R=30.0 2747.00 ftz b. N/A R= ftz 7. Windows Description Area c. N/A R= ftz a. U-Factor. Sgl, U=0.65 252.00 ft SHGC: SHGC=0.35 11. Ducts b. U-Factor. N/A ftz a. Sup: Attic Ret: Attic AH: Interior Sup. R= 6, 549.4 ftz SHGC: 12. Cooling systems (combined) c. U-Factor. N/A ftz a. Central Unit Cap: 43 kBtu/hr SHGC: SEER: 14 d. U-Factor. N/A ftz 13. Heating systems (combined) SHGC: a. Electric Heat Pu Pump Cap: 43 kBtu/hr e. U-Factor. N/A ftz HSPF:8.94 SHGC: - 14. Hot water systems :Floor Types Insulation . Area a. Electric " Cap: 40 gallons a. S11b n-Grade Edge Insulation R=0.0 2747.00 ftz EF: 0.92 d b. N/A R= ftz b. Conservation features c. N/A R= ftz None 15. Credits I Pstat Total As -Built Modified Loads: 33.54 Glass/Floor Area: 0.092 PASS Total Baseline Loads: 48.72 1 I hereby certify that the plans and Lp cificatio erd Review of the plans andiq%E Sthis calculation are in compliance e da ergy specifications covered by this ti0 Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: L C f Before construction is completed DATE: JP'-1!/hl 4r' this building will be inspected for compliance with Section 553.908 * �_ I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy ode l f''Op WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 8/14/2009 1 n-6R AM EneravGauaFA HSA - RaRPs20nR 11 Paae 1 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY ��,ARD ; ESTIMATED ENERGY PERFORMANCE INDEX* = 69 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing New (From Plans) 9. Wall' l ypes Insulation Area 2. Single family or multiple family Single-family a. Coincrete Block - Int Insul, Exterior R=4.2 1860.00 ft2 b. Frame - Wood, Adjacent R=19.0 196.00 ft2 3. Number of units, if multiple family 1 c. N/A,R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 5. Is this a worst case? No 10. Ceiling Types Insulation Area 6. Conditioned floor area (ft2) 2747 a. Under Attic (Vented) R=30.0 2747.00 ftZ 7. Windows" Description b. N/A II R= ft2 Area c. NIA I R= ft2 a. U-Factor. Sgl, U=0.65 252.00 ft2 11. Ducts'�I SHGC: SHGC=0.35 b. U-Factor: N/A SHGC: ft2 a. Sup:lAttic Ret: Attic AH: Interior Sup. R= 6, 549.4 ft2 12. Cooling�systems (combined) c. U-Factor: N/A ft2 a. Central Unit Cap: 43 kBtu/hr SHGC: I' SEER: 14 d. U-Factor. N/A ft2 13. Heatinglsystems (combined) SHGC: a. Electric Heat Pump Cap: 43 kBtu/hr e. U-Factor: N/A ft2 P HSPF: 8.94 SHGC: ' 14. Hot wate'rsystems Floor Types Insulation Area a. Electricy Cap: 40 gallons 3. Slab -On -Grade Edge Insulation R=0.0 2747.00 ftZ EF: 0.92 z b. Conserlviation features c. N/A R= ft2 None 15. Credits �� Pstat II� I certify that this home has complied with the Florida Energy Efficiency Code forl�Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. II I Builder Signature: Date: 9' 7,Lf Address of New H e: City/FL Zip: p. OIT$E STq?F °D WEmay *Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA - FlaRes2008 computer program. This is not a Building Energy Rating. If yourJ�Index is below 100, your home may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at (321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the Department of Community Affairs at (850) 487-1824. **Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G of the Florida Building Code, Residential, if not DEFAULT. I R EnergyGauge® USA - FlaRes2008 tl i I I • III ,I PROJECTIII .' Title: i James Allan Menit Renovatio Bedrooms: 3 �`� Adress Type: Street Address Building Type: FLAsBuilt Bathrooms: 0 II Lot # Owner. James Allan Merritt Conditioned Area: 2747 i SubDivision: _# of Units: 1 Total Stories: 1 PlatBook: Builder Name: Worst Case: No II Street: 804 Anita Street Permit Office: St. Lucie County Rotate Angle: 0 County: I St. Lucie Jurisdiction: Cross Ventilation: City, State, Zip: Fort Pierce , Family Type: Single-family Whole House Fan: II FL, New/Existing: New (From Plans) Comment: I I� CLIMATE ilk / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2i5 % Winter Summer Degree Days Moisture n Range FL, Fort Pierce FL ST LUCIE CO INTL 2 39 90 75 70 722 62 Low FLOORS �I # Floor Type Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio 258 ft 0 l` 2747 ft2 0 0 1 ROOF / Roof Gable Rooi, Solar Deck • V # Type Materials Area Area Colorll Absor. Tested Insul. Pitch � l 1 Hip Metal 2975 ft2 0 ft2 Medium` 0.96 No 30 22.6 deg ATTIC .I v # Type Ventilation Vent Ratio (1 in) IiArea RBS IRCC 1 Full attic Vented 300 2747 fe N N II CEILING # Ceiling Type R Value Area Framing Frac Truss Type 1 Under Attic (Vented) 30 2747 ft2, 0.11 ,V Wood WALLS II Cavityil Sheathing Framing Solar # Omt Adjacent To Wall Type R-Value', Area R Value Fraction Absor. 1 S Exterior Concrete Block - Int Insul 4.2 ill 198.4 ft2 0 0.75 2 N Exterior Concrete Block - Int Insul 4.2 80 ft2 0 0.75 3 N Exterior Concrete Block - Int Insul 4.2 `� 58.4 ft2 0 0.75 4 N Exterior Concrete Block - Int Insul 4.2 �� 96 ft2 0 0.75 5 E Exterior Concrete Block - Int Insul 4.2 '113.6 ft2 0 0.75 6 E Exterior Concrete Block - Int Insul 4.2 ,I 112 ft2 0 0.75 7 S Exterior Concrete Block - Int Insul 4.2 i 120 ft2 0 0.75 8 E Exterior Concrete Block - Int Insul 4.2 145.6 ft2 0 0.75 9 N Exterior Concrete Block - Int Insul 4.2 I 80 ft2 0 0.75 WALLS Cavity Sheathing Framing Solar # Omt Adjacent To Wall Type iii R-Value Area R-Value Fraction Absor. _ 10 W Exterior Concrete Block - Int Insul �I 4.2 56 ft2 0 0.75 11 S Garage Frame - Wood I! 19 148 f12 0.23 0.01 12 W Exterior Concrete Block - Int Insul I 4.2 140 ft2 0 0.75 13 W Exterior Concrete Block - Int Insul lil 4.2 80 ft2 0 0.75 14 W Exterior Concrete Block - Int Insul �II 4.2 76 ft2 0 0.75 15 W Exterior Concrete Block - Int Insul 4.2 160 ft2 0 0.75 16 N Exterior Concrete Block - Int Insul 4.2 184 ft2 0 0.75 17 E Exterior Concrete Block - Int Insul III 4.2 160 ft2 0 0.75 18 S Garage Frame - Wood II 19 I. 48 ft2 0.23 0.01 DOORS �11 # Omt Door Type Storms U Value Area 1 S Wood None 0.46 21 ft2 2 N Wood None 0.46 21 ft2 3 S Wood None 0.46 21 ft2 4 S Wood None 0.46 21 ft2 WINDOWS Window orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above. Overhang # Ornt Frame Panes NFRC U-Factor SHGC Storms ; Area Depth Separation Int Shade Screening 1 E Metal Single (Tinted) Yes 0.65 0.35 N 11� 30 ft2 2 ft 0 in 0 ft 0 in HERS 2006 None 2 N Metal Single (Tinted) Yes 0.65 0.35 N !, 9 ft2 2 ft0 in 0 ft0 in HERS 2006 None 3 N Metal Single (Tinted) Yes 0.65 0.35 N 9 ft2 2 ft 0 in 0 ft 0 in HERS 2006 None 4 E Metal Single (Tinted) Yes 0.65 0.35 N li 15 ft' 20 ft 0 in 0 ft 0 in HERS 2006 None 5 E Metal Single (Tinted) Yes 0.65 0.35 N i15 ft2 2 ft 0 in 0 ft 0 in HERS 2006 None 6 S Metal Single (Tinted) Yes 0.65 0.35 N 15 ft2 2 ft 0 in 0 ft 0 in HERS 2006 None 7 E Metal Single (Tinted) Yes 0.65 0.35 N 30 ft2 2 ft 0 in 0 ft 0 in HERS 2006 None 8 E Metal Single (Tinted) Yes 0.65 0.35 N 30 ft2 2 ft 0 in 0 ft 0 in HERS 2006 None 30 9 N Metal Single (Tinted) Yes 0.65 0.35 N ft2 2 ft 0 in 0 ft 0 in HERS 2006 None i, 10 W Metal Single (Tinted) Yes 0.65 0.35 N 30 ft2 2 ft 0 in 0 ft 0 in HERS 2006 None 11 W Metal Single (Tinted) Yes 0.65 0.35 N 18 ft2 2 ft 0 in 0 ft 0 in HERS 2006 None 12 W Metal Single (Tinted) Yes 0.65 0.35 N 9�Ift2 2 ft 0 in 0 ft 0 in HERS 2006 None 13 E Metal Single (rinted) Yes 0.65 0.35 N 12 ift 2 ft 0 in 0 ft 0 in HERS 2006 None INFILTRATION & VENTING �I 11lSupply - Forced Ventilation -- Run Time Fan . V Method SLA CFM 50 ACH 50 ELA EgLA CFM Exhaust CFM Fraction Watts Default 0.00036 2594 7.08 142.4 267.8 III 0 cfm 0 cfm 0 0 GARAGE'ti # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 384 ft' 384 ftz 64 ft 8 ft 11 • COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Ductless 1 Central Unit 2 Central Unit None None SEER: 14 SEER: 14 II 19 kBtu/hr 24 kBtu/hr 570 cfm 0.75 720 cfm 0.75 False False HEATING SYSTEM,; # System Type Subtype Efficiency Capacity Ductless 1 Electric Heat Pump 2 Electric Heat Pump None None HSPF 9 I' HSPF: 8.9 19 kBtu/hr 24 kBtu/hr False False HOT WATER SYSTEM' # System Type EF Cap I Use SetPnt Conservation 1 Electric 0.92 40 gal 160 gal 120 deg 1' None SOLAR HOT WATER SYSTEM t. FSEC Cert # Company Name !; Collector Storage System Model # Collector Model # Area Volume FEF None None !ti' I ft2 DUCTS II — Supply — — Return — # Location R-Value Area Location Area Leakage Type I', Air Percent (,Handler CFM 25 Leakage QN RLF 1 Attic 6 549.4 ft Attic 137.35 Default Leakage Interior TEMPERATURES 1, Programable Thermostat: Y CoolingMXJan [[XX]] Feb P(Xq] HeatinJan 0 Feb R1 Ventin Jan [[XX]] Feb [[XX]] Mar [[XX]] Apr Mar [X] Apr Mar [[XX]] Apr Ceiling Fans: [[XX]] May [[XX]] Jun [[XX]] Jul (X] May [X] Jun [X] Jul [[XX]] May [[XX]] Jun [[XX]] Jul jj Auge EX] Aug Sep [[XX]] Au Se [[XX]] Oct Nov [X] Oct Nov [[XX]] Oct Nov Dec � Dec Dec Thermostat Schedule: HERS 2006 Reference Hours -Schedule Type 1 2 3 4 5 Its 6 7 8 9 10 11 12 'Cooling (WD) AM 78 78 78 78 78 1' 78 78 78 80 80 80 80 PM 80 80 78 78 78 `, 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 �1,178 78 78 78 78 78 78 PM 78 78 78 78 78 .78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 �68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 it 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 a.d FORM 1100A-08 • Code Compliance Cheklist Residential Whole Building Performance Method A - Details ADDRESS: 804 Anita Street PERMIT #: Fort Pierce, FL, INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors N1106.AB.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls N1106.AB.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors N1106.AB.1.2.2 Penetrations/openings > 1/8" sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings N1106.AB.1.2.3 Between walls & ceilings; penetrations of ceiling plane to top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures N1106.AB.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1 /2" clearance & 3" from insulation; or Type IC with < 2.0 cfm from conditioned space, tested. Multi -story Houses N1106.AB.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration reqts N1106.AB.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) COMPONENTS SECTION REQUIREMENTS CHECK Water Heaters N1112.AB.3 Comply with efficiency requirements in Table N112.ABC.3. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. Swimming Pools & Spas N1112.AB.2.3 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Heat pump pool heaters shall have a minimum COP of 4.0. Shower heads N1112.AB.2.4 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems N1110.AB All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and installed in accordance with the criteria of Section N1110.AB. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls N1107.AB.2 Separate readily accessible manual or automatic thermostat for each system. Insulation N1104.AB.1 Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both N1102.6.1.1 sides. Common ceiling & floors R-11.