HomeMy WebLinkAbout0907-0243 ENERGY EFFICIENCY CODESCANNED
y FORM 1100A-08 BY
_''�'-.FLORIDA ENERGY EFFICIENG�' I5� R BUILDING CONSTRUCTION
Florida Department of Community Affairs Residential Performance Method A
Project Name: James Allan Merrit Renovation
Builder Name:
Street: 804 Anita Street
Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL ,
Permit Number.
Owner. James Allan Merritt
Jurisdiction:
Design Location: FL, Fort Pierce
1. New construction or existing
New (From Plans)
9. Wall Types
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.2 1860.00 ftz
b. Frame - Wood, Adjacent
R=19.0 196.00 ftz
3. Number of units, if multiple family
1
c. N/A
R= ftz
4. Number of Bedrooms
3
d. N/A
R= ftz
5. Is this a worst case?
No
10. Ceiling Types
Insulation Area
6. Conditioned floor area (ftz)
2747
a. Under Attic (Vented)
R=30.0 2747.00 ftz
b. N/A
R= ftz
7. Windows Description
Area
c. N/A
R= ftz
a. U-Factor. Sgl, U=0.65
252.00 ft
SHGC: SHGC=0.35
11. Ducts
b. U-Factor. N/A
ftz
a. Sup: Attic Ret: Attic AH: Interior Sup.
R= 6, 549.4 ftz
SHGC:
12. Cooling systems (combined)
c. U-Factor. N/A
ftz
a. Central Unit
Cap: 43 kBtu/hr
SHGC:
SEER: 14
d. U-Factor. N/A
ftz
13. Heating systems (combined)
SHGC:
a. Electric Heat Pu
Pump
Cap: 43 kBtu/hr
e. U-Factor. N/A
ftz
HSPF:8.94
SHGC:
-
14. Hot water systems
:Floor Types
Insulation . Area
a. Electric "
Cap: 40 gallons
a. S11b n-Grade Edge Insulation
R=0.0 2747.00 ftz
EF: 0.92
d b. N/A
R= ftz
b. Conservation features
c. N/A
R= ftz
None
15. Credits I
Pstat
Total As -Built Modified Loads: 33.54
Glass/Floor Area: 0.092
PASS
Total Baseline Loads: 48.72 1
I hereby certify that the plans and Lp cificatio erd
Review of the plans andiq%E
Sthis
calculation are in compliance
e da ergy
specifications covered by this
ti0
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: L
C f
Before construction is completed
DATE: JP'-1!/hl
4r'
this building will be inspected for
compliance with Section 553.908
* �_
I hereby certify that this building, as designed,
is in compliance
Florida Statutes.
with the Florida Energy ode
l
f''Op WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
8/14/2009 1 n-6R AM EneravGauaFA HSA - RaRPs20nR 11 Paae 1 of 6
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY ��,ARD
;
ESTIMATED ENERGY PERFORMANCE INDEX* = 69
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
New (From Plans) 9. Wall' l ypes Insulation Area
2. Single family or multiple family
Single-family a. Coincrete Block - Int Insul, Exterior R=4.2 1860.00 ft2
b. Frame - Wood, Adjacent R=19.0 196.00 ft2
3. Number of units, if multiple family
1 c. N/A,R= ft2
4. Number of Bedrooms
3 d. NIA R= ft2
5. Is this a worst case?
No 10. Ceiling Types Insulation Area
6. Conditioned floor area (ft2)
2747 a. Under Attic (Vented) R=30.0 2747.00 ftZ
7. Windows" Description
b. N/A II R= ft2
Area c. NIA I R= ft2
a. U-Factor. Sgl, U=0.65
252.00 ft2
11. Ducts'�I
SHGC: SHGC=0.35
b. U-Factor: N/A
SHGC:
ft2 a. Sup:lAttic Ret: Attic AH: Interior Sup. R= 6, 549.4 ft2
12. Cooling�systems (combined)
c. U-Factor: N/A
ft2 a. Central Unit Cap: 43 kBtu/hr
SHGC:
I' SEER: 14
d. U-Factor. N/A
ft2 13. Heatinglsystems (combined)
SHGC:
a. Electric Heat Pump Cap: 43 kBtu/hr
e. U-Factor: N/A
ft2 P
HSPF: 8.94
SHGC:
'
14. Hot wate'rsystems
Floor Types Insulation Area a. Electricy Cap: 40 gallons
3. Slab -On -Grade Edge Insulation R=0.0 2747.00 ftZ EF: 0.92
z
b. Conserlviation features
c. N/A R=
ft2 None
15. Credits �� Pstat
II�
I certify that this home has complied with the Florida Energy Efficiency Code forl�Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. II
I
Builder Signature: Date: 9' 7,Lf
Address of New H e: City/FL Zip:
p. OIT$E STq?F
°D WEmay
*Note: The home's estimated Energy Performance Index is only available through the EnergyGauge USA -
FlaRes2008 computer program. This is not a Building Energy Rating. If yourJ�Index is below 100, your home
may qualify for incentives if you obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at
(321) 638-1492 or see the Energy Gauge web site at energygauge.com for information and a list of certified
Raters. For information about Florida's Energy Efficiency Code for Building Construction, contact the
Department of Community Affairs at (850) 487-1824.
**Label required by Section 13-104.4.5 of the Florida Building Code, Building, or Section B2.1.1 of Appendix G
of the Florida Building Code, Residential, if not DEFAULT. I
R EnergyGauge® USA - FlaRes2008
tl
i I
I
• III
,I
PROJECTIII
.' Title:
i
James Allan Menit Renovatio Bedrooms: 3 �`�
Adress Type:
Street Address
Building Type:
FLAsBuilt
Bathrooms: 0 II
Lot #
Owner.
James Allan Merritt
Conditioned Area: 2747 i
SubDivision:
_# of Units:
1
Total Stories: 1
PlatBook:
Builder Name:
Worst Case: No
II Street:
804 Anita Street
Permit Office:
St. Lucie County
Rotate Angle: 0
County:
I
St. Lucie
Jurisdiction:
Cross Ventilation:
City, State, Zip:
Fort Pierce ,
Family Type:
Single-family
Whole House Fan:
II
FL,
New/Existing:
New (From Plans)
Comment:
I
I�
CLIMATE
ilk
/
IECC Design Temp Int Design Temp Heating Design
Daily Temp
V Design Location
TMY Site Zone 97.5 %
2i5 % Winter Summer Degree Days Moisture
n
Range
FL, Fort Pierce FL ST LUCIE CO INTL 2 39
90 75 70 722
62
Low
FLOORS
�I
#
Floor Type
Perimeter R-Value
Area
Tile Wood Carpet
1
Slab -On -Grade Edge Insulatio 258 ft 0
l` 2747 ft2
0 0
1
ROOF
/
Roof Gable
Rooi, Solar Deck
• V #
Type Materials Area Area
Colorll Absor. Tested Insul.
Pitch
� l
1
Hip
Metal 2975 ft2 0 ft2 Medium`
0.96 No 30
22.6 deg
ATTIC
.I
v #
Type
Ventilation Vent Ratio (1 in)
IiArea RBS IRCC
1
Full attic
Vented 300
2747 fe N N
II
CEILING
#
Ceiling Type
R Value
Area Framing Frac
Truss Type
1
Under Attic (Vented)
30
2747 ft2, 0.11
,V
Wood
WALLS
II
Cavityil Sheathing
Framing
Solar
#
Omt Adjacent To
Wall Type
R-Value', Area R Value
Fraction
Absor.
1
S Exterior
Concrete Block - Int Insul
4.2 ill 198.4 ft2
0
0.75
2
N Exterior
Concrete Block - Int Insul
4.2 80 ft2
0
0.75
3
N Exterior
Concrete Block - Int Insul
4.2 `� 58.4 ft2
0
0.75
4
N Exterior
Concrete Block - Int Insul
4.2 �� 96 ft2
0
0.75
5
E Exterior
Concrete Block - Int Insul
4.2 '113.6 ft2
0
0.75
6
E Exterior
Concrete Block - Int Insul
4.2 ,I 112 ft2
0
0.75
7
S Exterior
Concrete Block - Int Insul
4.2 i 120 ft2
0
0.75
8
E Exterior
Concrete Block - Int Insul
4.2 145.6 ft2
0
0.75
9
N Exterior
Concrete Block - Int Insul
4.2 I 80 ft2
0
0.75
WALLS
Cavity
Sheathing
Framing
Solar
#
Omt
Adjacent To
Wall Type
iii R-Value
Area R-Value
Fraction Absor.
_ 10
W
Exterior
Concrete Block - Int Insul
�I 4.2
56 ft2
0
0.75
11
S
Garage
Frame - Wood
I! 19
148 f12
0.23
0.01
12
W
Exterior
Concrete Block - Int Insul
I 4.2
140 ft2
0
0.75
13
W
Exterior
Concrete Block - Int Insul
lil 4.2
80 ft2
0
0.75
14
W
Exterior
Concrete Block - Int Insul
�II 4.2
76 ft2
0
0.75
15
W
Exterior
Concrete Block - Int Insul
4.2
160 ft2
0
0.75
16
N
Exterior
Concrete Block - Int Insul
4.2
184 ft2
0
0.75
17
E
Exterior
Concrete Block - Int Insul
III 4.2
160 ft2
0
0.75
18
S
Garage
Frame - Wood
II 19
I.
48 ft2
0.23
0.01
DOORS
�11
#
Omt
Door Type
Storms
U Value
Area
1
S
Wood
None
0.46
21 ft2
2
N
Wood
None
0.46
21 ft2
3
S
Wood
None
0.46
21 ft2
4
S
Wood
None
0.46
21 ft2
WINDOWS
Window orientation below is as entered. Actual orientation is modified by rotate angle shown in "Project" section above.
Overhang
#
Ornt
Frame
Panes
NFRC U-Factor
SHGC
Storms ; Area
Depth Separation
Int Shade
Screening
1
E
Metal
Single (Tinted)
Yes 0.65
0.35
N 11� 30 ft2
2 ft 0 in 0 ft 0 in
HERS 2006
None
2
N
Metal
Single (Tinted)
Yes 0.65
0.35
N !, 9 ft2
2 ft0 in 0 ft0 in
HERS 2006
None
3
N
Metal
Single (Tinted)
Yes 0.65
0.35
N 9 ft2
2 ft 0 in 0 ft 0 in
HERS 2006
None
4
E
Metal
Single (Tinted)
Yes 0.65
0.35
N li 15 ft'
20 ft 0 in 0 ft 0 in
HERS 2006
None
5
E
Metal
Single (Tinted)
Yes 0.65
0.35
N i15 ft2
2 ft 0 in 0 ft 0 in
HERS 2006
None
6
S
Metal
Single (Tinted)
Yes 0.65
0.35
N 15 ft2
2 ft 0 in 0 ft 0 in
HERS 2006
None
7
E
Metal
Single (Tinted)
Yes 0.65
0.35
N 30 ft2
2 ft 0 in 0 ft 0 in
HERS 2006
None
8
E
Metal
Single (Tinted)
Yes 0.65
0.35
N 30 ft2
2 ft 0 in 0 ft 0 in
HERS 2006
None
30
9
N
Metal
Single (Tinted)
Yes 0.65
0.35
N ft2
2 ft 0 in 0 ft 0 in
HERS 2006
None
i,
10
W
Metal
Single (Tinted)
Yes 0.65
0.35
N 30 ft2
2 ft 0 in 0 ft 0 in
HERS 2006
None
11
W
Metal
Single (Tinted)
Yes 0.65
0.35
N 18 ft2
2 ft 0 in 0 ft 0 in
HERS 2006
None
12
W
Metal
Single (Tinted)
Yes 0.65
0.35
N 9�Ift2
2 ft 0 in 0 ft 0 in
HERS 2006
None
13
E
Metal
Single (rinted)
Yes 0.65
0.35
N 12 ift
2 ft 0 in 0 ft 0 in
HERS 2006
None
INFILTRATION & VENTING
�I
11lSupply
- Forced Ventilation -- Run Time
Fan .
V Method
SLA
CFM 50 ACH 50
ELA
EgLA CFM Exhaust CFM
Fraction
Watts
Default
0.00036
2594 7.08
142.4
267.8 III 0 cfm 0 cfm
0
0
GARAGE'ti
# Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 384 ft'
384 ftz
64 ft
8 ft
11
•
COOLING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Air Flow SHR
Ductless
1 Central Unit
2 Central Unit
None
None
SEER: 14
SEER: 14
II
19 kBtu/hr
24 kBtu/hr
570 cfm 0.75
720 cfm 0.75
False
False
HEATING SYSTEM,;
# System Type
Subtype
Efficiency
Capacity
Ductless
1 Electric Heat Pump
2 Electric Heat Pump
None
None
HSPF 9
I'
HSPF: 8.9
19 kBtu/hr
24 kBtu/hr
False
False
HOT WATER SYSTEM'
# System Type
EF Cap I
Use SetPnt
Conservation
1 Electric
0.92 40 gal 160 gal 120 deg
1'
None
SOLAR HOT WATER SYSTEM
t.
FSEC
Cert # Company Name
!; Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
!ti' I
ft2
DUCTS
II
— Supply — — Return —
# Location R-Value Area Location Area Leakage Type
I', Air Percent
(,Handler CFM 25 Leakage QN
RLF
1 Attic 6
549.4 ft Attic
137.35 Default Leakage
Interior
TEMPERATURES
1,
Programable Thermostat: Y
CoolingMXJan [[XX]] Feb P(Xq]
HeatinJan 0 Feb R1
Ventin Jan [[XX]] Feb [[XX]]
Mar [[XX]] Apr
Mar [X] Apr
Mar [[XX]] Apr
Ceiling Fans:
[[XX]] May [[XX]] Jun [[XX]] Jul
(X] May [X] Jun [X] Jul
[[XX]] May [[XX]] Jun [[XX]] Jul
jj Auge
EX] Aug Sep
[[XX]] Au Se
[[XX]] Oct Nov
[X] Oct Nov
[[XX]] Oct Nov
Dec
� Dec
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
-Schedule Type
1
2
3
4
5
Its 6
7
8
9
10
11
12
'Cooling (WD)
AM
78
78
78
78
78
1' 78
78
78
80
80
80
80
PM
80
80
78
78
78
`, 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
�1,178
78
78
78
78
78
78
PM
78
78
78
78
78
.78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
�68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
it
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
a.d
FORM 1100A-08
• Code Compliance Cheklist
Residential Whole Building Performance Method A - Details
ADDRESS: 804 Anita Street PERMIT #:
Fort Pierce, FL,
INFILTRATION REDUCTION COMPLIANCE CHECKLIST
COMPONENTS
SECTION
REQUIREMENTS FOR EACH PRACTICE
CHECK
Exterior Windows & Doors
N1106.AB.1.1
Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area.
Exterior & Adjacent Walls
N1106.AB.1.2.1
Caulk, gasket, weatherstrip or seal between: windows/doors &
frames, surrounding wall; foundation & wall sole or sill plate; joints
between exterior wall panels at comers; utility penetrations;
between wall panels & top/bottom plates; between walls and floor.
EXCEPTION: Frame walls where a continuous infiltration barrier is
installed that extends from, and is sealed to, the foundation to the
top plate.
Floors
N1106.AB.1.2.2
Penetrations/openings > 1/8" sealed unless backed by truss or
joint members.
EXCEPTION: Frame floors where a continuous infiltration barrier
is installed that is sealed to the perimeter, penetrations and seams.
Ceilings
N1106.AB.1.2.3
Between walls & ceilings; penetrations of ceiling plane to top floor;
around shafts, chases, soffits, chimneys, cabinets sealed to
continuous air barrier; gaps in gyp board & top plate; attic access.
EXCEPTION: Frame ceilings where a continuous infiltration barrier
is installed that is sealed at the perimeter, at penetrations and
seams.
Recessed Lighting Fixtures
N1106.AB.1.2.4
Type IC rated with no penetrations, sealed; or Type IC or non -IC
rated, installed inside a sealed box with 1 /2" clearance & 3" from
insulation; or Type IC with < 2.0 cfm from conditioned space,
tested.
Multi -story Houses
N1106.AB.1.2.5
Air barrier on perimeter of floor cavity between floors.
Additional Infiltration reqts
N1106.AB.1.3
Exhaust fans vented to outdoors, dampers; combustion space
heaters comply with NFPA, have combustion air.
OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
COMPONENTS
SECTION
REQUIREMENTS
CHECK
Water Heaters
N1112.AB.3
Comply with efficiency requirements in Table N112.ABC.3. Switch
or clearly marked circuit breaker (electric) or cutoff (gas) must be
provided. External or built-in heat trap required.
Swimming Pools & Spas
N1112.AB.2.3
Spas & heated pools must have covers (except solar heated).
Non-commercial pools must have a pump timer. Gas spa & pool
heaters must have a minimum thermal efficiency of 78%.
Heat pump pool heaters shall have a minimum COP of 4.0.
Shower heads
N1112.AB.2.4
Water flow must be restricted to no more than 2.5 gallons per
minute at 80 PSIG.
Air Distribution Systems
N1110.AB
All ducts, fittings, mechanical equipment and plenum chambers
shall be mechanically attached, sealed, insulated and installed in
accordance with the criteria of Section N1110.AB.
Ducts in unconditioned attics: R-6 min. insulation.
HVAC Controls
N1107.AB.2
Separate readily accessible manual or automatic thermostat for
each system.
Insulation
N1104.AB.1
Ceilings -Min. R-19. Common walls -frame R-11 or CBS R-3 both
N1102.6.1.1
sides. Common ceiling & floors R-11.