0907-0243 RESIDENTIAL HVAC LOADS
A . SCANNED By St Lucie County James Allan Merritt Renovation HVAC Load Calculations for James Allan Merritt 804 Anita Street Fort Pierce, Florida FU RzsiDF.NPnAL. ",c HVAC LoADs Prepared By: Residential Energy Calc's Friday, August 14, 2009 J. Rhvac Residential Light Commercial HVAC Loads Elite SoftHiare Development, Inc KenLHumphrgy s ` James Allan MemftRenovatton .Port`_SamtLucie FL.34983 _ :.F. °. Pa e,2 Project Report benerawro'ect Information--'. Project Title: James Allan Merritt Renovation Designed By: Harvey E. Koehnen Project Date: Monday, July 13, 2009 Client Name: James Allan Merritt Client Address: 804 Anita Street Client City: Fort Pierce, Florida Company Name: Residential Energy Calc's i Desi' n°Data Reference City: Fort Pierce, Florida Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Elevation Sensible Adj. Factor: 1.000 Elevation Total Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Elevation Heating Adj. Factor: 1.000 Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Dry Bulb Difference Winter: 42 0 30 72 3 Summer: 90 78 50 75 61 .Check Fi ores ., = , 171 Total Building Supply CFM: 1,278 CFM Per Square ft.: 0.465 Square ft. of Room Area: 2,749 Square ft. Per Ton: 838 Volume (fr) of Cond. Space: 25,094 Saildin Loads- . Total Heating Required Including Ventilation Air: 45,154 Btuh 45.154 MBH Total Sensible Gain: 29,493 Btuh 75 % Total Latent Gain: 9,717 Btuh 25 % Total Cooling Required Including Ventilation Air: 39,211 Btuh 3.27 Tons (Based On Sensible + Latent) 3.28 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Rhvac Residential& Light:Commercial HVAC Loads _ EliteSofftware Development, Inc: Ken _Humphrey James`P&n Memtt Renova ion ,Port -Saint Lucie, FL 34983 age 37 Miscellaneous 'Reparf System 1 Rhem-.Or Equivalent Outdoor °; Outdoor., Indoor. `... Indoor Grains Input -Data, - Dr y Bulb,, - -Wet Bulb, Rel:Num - = D Bulb ' Difference Winter: 42 0 30 72 3.44 Summer: 90 78 50 75 61.09 System 2 Rheem° Or Equivalent Outdoor, ; - Outdoor -,indoor ; .indoor .. Grains, Input Data 4 "- D Bulb , ,fillet But , Re1.Hurn ,i .,D ,Bulb', -'Difference Winter: 42 0 30 72 3.44 Summer: 90 78 50 75 61.09 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./l00 ft. 0.1000 in.wg./l00 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside'Air Data = Winter Summer Infiltration: 0.281 AC/hr 0.149 AC/hr Above Grade Volume: X 25,094 Cu.ft. X 25,094 Cu.ft. 7,062 Cu.ft./hr 3,728 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 118 CFM 62 CFM Total Building Ventilation: 85 CFM 85 CFM -System 1- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) --System 2- Infiltration & Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference) Infiltration & Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference) Infiltration & Ventilation Sensible Loss Multiplier: 32.97 = (1.10 X 0.999 X 30.00 Winter Temp. Difference) Duct Load -_Factor Scenarios foF.Sy"stemal'. ' ' Attic Duct' 'i Duct Surface { From!. No.. ', T e Rescri tian = ; Location ; Ceilin" " LeaKa a ; ` lrisulation °;; , . 1 Supply Main Attic 16B 0.12 6 302 No 1 Return Main Attic 16B 0.24 6 56 No Duct Load Factor Scenarios for..S, tem 2 ' .. . - h Attic Ductl Duct; .Surface;: From. No. s T e - Descri lion Locatiari ='' Ceding Leakage?, insulationw . �-Area Ii'� -MDD� 1 Supply Main Attic 16B 0.12 6 420 No 1 Return Main Attic 16B 0.24 6 78 No Rhyac -i Residential& Light .Commercial MACLoads_ Elite Software Development, inc.] I ..Ump rey-, James Allan Memtt RthaVatibri .PorLSaintLucie, ', 34983 Page, Load Preview Rcsport.":,-...: SvS Svq i Has Nets Recl ft. 2 i Sen Lat Net; Sen' I Htg �Ilii i Act; Duct Scope AED; Ton Ton! ITon'! Area! Gainj Gain Gain� Loss; CFM CFMI CFMI Size Building 3.27 3.28: 83& 2,749� 29.49X 9,7171 39,211:' 45,154'! 55V 1,278� 1,278� ............ ... .. ......... ... . ... ... .... . System I ............. . .............. Yes'1.361.36. 1,118- ------ 12,208" .......... . .. 4..,080 . ............... ...... 16,288:! ... --------- ..... 18664: .......... 773.1. 129 9 9xI3 .. ......... ----------- - Ventilation --- --- --- --------------- .-822 -----...........------- - ---- ------------- .. . ........ . . ... ........ ......... . ..... .......... 577: ... ...--- 1,453: . ................. 2,030' ........ . 1,154: ......... ............. ......... ........... ........ .. Duct Latent 1,036� 1,036i ....... ..... -- -------- ----- ....... ..................... Zone 1 . .... . ..... ...... - . ....... 1,118 11,631: . . 1,591: . .......... ....... ........ 13,222: . 17,51 Os ................ 228� . ...... 529 ....... 9x13 1-Living ........... .......... ... 372 . ........ 2,517:� ........... 292' -- ----- ---- 2,809:: 4,7131 61 115 1-6 2-Nook . ............. .... .. .... . ...... I I v ... .. ...... I . ..... 0! 207 ------------ 207: - 3 9 . . _........... . .. ...--------....... -207: ---- 160: -- 2,702: 162: - 2,864 ------------- 1,9941; 26� - ------ 123 -1-4 ---- 1-7 ...3....K....i.t.c..h..e...n. ........ .......... . ... . ......... ......... .... 4-Bath 2 .. .. 95 --- 611; - W, ---- 6971 - 1,259� W --- 28� ....... . . -4 ........ . . ..... ..... . .. ........ . 5-Bedroom 3 170� .... .. .. ----------- 2,214. . ......... 309. 2,523-1 ............ 4,292 56MI ......... 101"1-6 .... ... .... ----------- 6-Bedroom 2 ..... ..... .... ..... ... ........ . .......... .... ..... .. . ....... . ....... ................ ... ..... .............. ......... ..... ..... ..... ..... 21 O'� .... ... ........ 3,381: ---- 742:: ------------------------- 4,1231 5,045� 66 . . ... .... 154: .... .... 1-7 .... ...... . .............. ......... . . .... ... ...... System 2 ...... 1. 1-..-.-1--- 1 . ... . ..... ................ - ... ........... ........... ............. .. No 1.91 1.92:' 849: .. .. ............... .......... .. . . ..... .... 1,631 ........ -.- ........ 17,285 ......... . . ........... 5,638 ...... 22,9231 ... ....... 7 91 749� IOxI5 Ventilation 8242; 2,075. 2,899: 1,649: .... ........... - ------- --- Duct Latent 1,474: 1,474;: - ----------- ... ................. Zone 2 ......... .. .............................. ......... ... 1,631 ....... 16,461 . 2,088: .............. 18,549� 24,842, 323� .......... ... 749, 10A 5 ............ - 7-Dining ........... . ... ......... .......... ............. . ............... 280; 3,780! ............ ....... 279 ..... 4,059' ........ 5,267 69 172 2-5 8-Walk in Closets . .......... ....... . ..... .... ... 130: ............ 748: . 72 820� .................. 2,363: . ................. 31: 1 34 1-4 - ---------------- - -------------------- 9-Master Bedroom --- . ..... ----------- -- 324!� ------- -------- . ......... 3,784: ..... . -- -------- 650�; -- 4,434' ------- 3,858 50 1721 2-5 10-Master Bath ............ .. . ... ...... ....... - ------ 185� ... .......... . ......... 1,857;: __ ..... .. .... 95, .......... . 1,952: 1,966: 26: 84:: 1-5 ...... .. .. . . .. ........ . . ......... - -- - ------- - 11-Utility -.- - ------ ..... .... ........ ... ....... . ................ . ..... -- - ------- 119; --- - ---- -------------------- 711' .300:- ------- 1,011 ---------- 2162 -- - 3: EM 32 1-4 ........ . .... .... .................. 12-Bath 3 . ............. .............. --- ---------- 57: 811 ----- ------ ......... 91: . . ............... .... ...... 902: . - . .. 11474� 19 .......... 37 1-4 .. .. ...... . .... ..... ........... .............. 13-Rec Room ... . . ---------- ----- ------- . . ..... ..... .......... q . .. ............. 460� ... .... 4,443 .. 601 ....................... 5,044• .. 9,159 ...... 202' 2-6 ---- ------- .. . ........... 14-Hall -------------- ------------- ---- . ... ..... ------ 76, ............. --- --- 3271 ...... ......... 0* ---- ----- 327: ---------- 539- 7� -------- 151. ---------- ----------------- 1-4 I Rhvac Residential & Light Commercial HVAC Loads EIRe.Software Development1 lnc. Ken Humphrey - " JamesAUlan.Mei ffi t Renovation Port Saint Lucie, FL 34983' Page 5 Total Building Summary Load$ Component Area Sen Lat Sen Total Description Quan Loss Gain ". Gain --Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 232.5 4,540 0 6,429 6,429 metal frame with break, u-value 0.65, SHGC 0.35 10A-m: Glazing -French door, single pane clear glass, 30 586 0 514 514 metal frame no break, u-value 0.65, SHGC 0.35 11 D: Door -Wood - Solid Core 63 738 0 639 639 11 P: Door -Metal - Polyurethane Core 21 91 0 91 91 13A-4ocs: Wall -Block, board insulation only, R-4 board 1647.3 7,065 0 3,605 3,605 insulation, open core, siding finish 12E-0sw: Part -Frame, R-19 insulation in 2 x 6 stud cavity, 167 170 0 170 170 no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 2747.8 2,640 0 3,517 3,517 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 260 10,591 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 26,422 0 14,965 14,965 People: 4 800 920 1,720 Equipment: 300 1,500 1,800 Lighting: 0 0 0 Ductwork: 12,049 2,511 8,831 11,342 Infiltration: Winter CFM: 118, Summer CFM: 62 3,881 2,579 1,024 3,603 Ventilation: Winter CFM: 85, Summer CFM: 85 2,802 3,528 1,401 4,929 AED Excursion: 0 0 852 852 Total Building Load Totals: 45,154 9,717 29,493 39,211 Check.Fi ores_ Total Building Supply CFM: 1,278 CFM Per Square ft.: 0.465 Square ft. of Room Area: 2,749 Square ft. Per Ton: 838 Volume (ft') of Cond. Space: 25,094 Building Loads, Total Heating Required Including Ventilation Air: 45,154 Btuh 45.154 MBH Total Sensible Gain: 29,493 Btuh 75 % Total Latent Gain: 9,717 Btuh 25 % Total Cooling Required Including Ventilation Air: 39,211 Btuh 3.27 Tons (Based On Sensible + Latent) 3.28 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. [Rhvac Residential & Ught Commetcial HVAC Loads Ken.Humphrey Elite Software Development, Inc: James.Allan MemttRenovation Port,Saint Lucie FL. 34983 - Pageg 6 System :, Rhea►,Or Egtaivalent' Summary Loads'..: . Component Area Sen Lat : Sen Total Description ;_ : -, ,.,. ,°:; Quan w ..... . Loss-' - ,.. Gain :..- Gain ; , _ .. Gain. 1A-cb-o: Glazing -Single pane, operable window, clear, 117 2,285 0 2,529 2,529 metal frame with break, u-value 0.65, SHGC 0.35 11 D: Door -Wood - Solid Core 42 492 0 426 426 13A4ocs: Wall -Block, board insulation only, R-4 board 649.4 2,785 0 1,421 1,421 insulation, open core, siding finish 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1117.7 1,074 0 1,430 1,430 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 98 3,992 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 10,628 0 5,806 5,806 People: 2 400 460 860 Equipment: 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 5,050 1,036 3,692 4,728 Infiltration: Winter CFM: 56, Summer CFM: 29 1,832 1,191 473 1,664 Ventilation: Winter CFM: 35, Summer CFM: 35 1,154 1,453 577 2,030 System 1 Rhem Or Equivalent Load Totals: 18,664 4,080 12,208 16,288 Che& R ures Supply CFM: 529 CFM Per Square ft.: 0.473 Square ft. of Room Area: 1,118 Square ft. Per Ton: 822 Volume (fF) of Cond. Space: 10,758 System Loads, Total Heating Required Including Ventilation Air: 18,664 Btuh 18.664 MBH Total Sensible Gain: 12,208 Btuh 75 % Total Latent Gain: 4,080 Btuh 25 % Total Cooling Required Including Ventilation Air: 16,288 Btuh 1.36 Tons (Based On Sensible + Latent) 1.36 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. rN fr Rhvac Residential_ Light Commercral HV10.0 Load`s Keri Humphrey Elite Software Development, Inc. James Allan Memft Renovation Rort`Samt Lucie FL . 34 83 ....: w . Pa e7; Sysiem-2 Rheem'Or'Equivalent SUMMary LoadS' . : Cotnponenf Area i, Sen Lat , Sen.,"- Total Description.. Quan . Loss - -:Gain ; - Gain--`-. :Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 115.5 2,255 0 3,900 3,900 metal frame with break, u-value 0.65, SHGC 0.35 10A-m: Glazing -French door, single pane clear glass, 30 586 0 514 514 metal frame no break, u-value 0.65, SHGC 0.35 11 D: Door -Wood - Solid Core 21 246 0 213 213 11 P: Door -Metal - Polyurethane Core 21 91 0 91 91 13A-4ocs: Wall -Block, board insulation only, R-4 board 997.9 4,281 0 2,184 2,184 insulation, open core, siding finish 12E-Osw: Part -Frame, R-19 insulation in 2 x 6 stud cavity, 167 170 0 170 170 no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1630 1,566 0 2,087 2,087 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 162 6,599 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil - - .._..-- - ......_ ..... ...... ...... .. - Subtotals for structure: 15,794 0 9,159 9,159 People: 2 400 460 860 Equipment: 300 300 600 Lighting: 0 0 0 Ductwork: 6,999 1,474 5,139 6,613 Infiltration: Winter CFM: 62, Summer CFM: 33 2,049 1,388 551 1,939 Ventilation: Winter CFM: 50, Summer CFM: 50 1,649 2,075 824 2,899 AED Excursion: __.._---------- - . ......_._------- 0 0 852 852 System 2 Rheem Or Equivalent Load Totals: 26,490 5,638 17,285 22,923 Cheek, Fi ores- Supply CFM: 749 CFM Per Square ft.: 0.459 Square ft. of Room Area: 1,631 Square ft. Per Ton: 849 Volume (W) of Cond. Space: 141336 S `sfem Loads Total Heating Required Including Ventilation Air: 26,490 Btuh 26.490 MBH Total Sensible'Gain: 17,285 Btuh 75 % Total Latent Gain: 5,638 Btuh 25 % Total Cooling Required Including Ventilation Air: 22,923 Btuh 1.91 Tons (Based On Sensible + Latent) 1.92 Tons (Based On 75% Sensible Capacity) Notes, Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. 9 Rhvac Residential & Light Commercial HVAC Loads Elite software Dey�lopment, Inc:; on, Ken:Humphrey r ` James`Allan Memft Renovation. ,. Lucie FL:;34983 . :` Page 8 Systom -I, Zo► 6 -l' Surii-M:ary-Loads (Average L®ad Procedure for Rooms) :. :. ' :: Co[npone►t - <; Area : _ : Seri La#_ .. Sen Total Descri lion ,, .. - -, :..r : Quan �;.4 . =Loss .` Gain -. Gain -Gain;. 1A-cb-o: Glazing -Single pane, operable window, clear, 117 2,285 0 2,529 2,529 metal frame with break, u-value 0.65, SHGC 0.35 11 D: Door -Wood - Solid Core 42 492 0 426 426 13A-4ocs: Wall -Block, board insulation only, R-4 board 649.4 2,785 0 1,421 1,421 insulation, open core, siding finish 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1117.7 1,074 0 1,430 1,430 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 98 3,992 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 10,628 0 5,806 5,806 People: 2 400 460 860 Equipment: 0 1,200 1,200 Lighting: 0 0 0 Ductwork: 5,050 0 3,692 3,692 Infiltration: Winter CFM: 56, Summer CFM: 29 1,832 1,191 473 1,664 System 1, Zone 1 Load Totals: 17,510 1,591 11,631 13,222 Supply CFM: 529 CFM Per Square ft.: 0.473 Square ft. of Room Area: 1,118 Square ft. Per Ton: 1,012 Volume (ft3) of Cond. Space: 10,758 Zone Loads Total Heating Required: 17,510 Btuh 17.510 MBH Total Sensible Gain: 11,631 Btuh 88 % Total Latent Gain: 1,591 Btuh 12 % Total Cooling Required: 13,222 Btuh 1.10 Tons (Based On Sensible + Latent) 1.10 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. Rhvac Residential & Light commeraal HVAC Loads Elite Software Development, Inc. Ken Humphrey James:Allan Memo Renovatton L . e Pa'9uceFL4983PorfSaint System►m m 2, Zano 2 Suary Loads (overage Load Procedure for Rooms) :.. Component Area' . Sen " Lat ' Sen Total' Qescri Lion Quan - LQss:. ,.. ...:,Gain.. .. Gain Gain 1A-cb-o: Glazing -Single pane, operable window, clear, 115.5 2,255 0 3,900 3,900 metal frame with break, u-value 0.65, SHGC 0.35 10A-m: Glazing -French door, single pane clear glass, 30 586 0 514 514 metal frame no break, u-value 0.65, SHGC 0.35 11 D: Door -Wood - Solid Core 21 246 0 213 213 11 P: Door -Metal - Polyurethane Core 21 91 0 91 91 13A-4ocs: Wall -Block, board insulation only, R-4 board 997.9 4,281 0 2,184 2,184 insulation, open core, siding finish 12E-Osw: Part -Frame, R-19 insulation in 2 x 6 stud cavity, 167 170 0 170 170 no board insulation, siding finish, wood studs 16C-30: Roof/Ceiling-Under Attic with Insulation on Attic 1630 1,566 0 2,087 2,087 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, White or Light Color Shingles, Any Wood Shake, Light Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor -Slab on grade, No edge insulation, no 162 6,599 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 15,794 0 9,159 9,159 People: 2 400 460 860 Equipment: 300 300 600 Lighting: 0 0 0 Ductwork: 6,999 0 5,139 5,139 Infiltration: Winter CFM: 62, Summer CFM: 33 2,049 1,388 551 1,939 System 2, Zone 2 Load Totals: 24,842 2,088 16,461 18,549 Check Figures ; Supply CFM: 749 CFM Per Square ft.: 0.459 Square ft. of Room Area: 1,631 Square ft. Per Ton: 1,053 Volume (ft?) of Cond. Space: 14,336 Total Heating Required: 24,842 Btuh 24.842 MBH Total Sensible Gain: 16,461 Btuh 89 % Total Latent Gain: 2,088 Btuh 11 % Total Cooling Required: 18,549 Btuh 1.55 Tons (Based On Sensible + Latent) 1.55 Tons (Based On 75% Sensible Capacity) Notes Calculations are based on 8th edition of ACCA Manual J. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads. ]Rh Residential tight Comrnercral HVAC Loads Ken Humphrey s Elite Software Development, Inc: James'Allan,Up, Renovation Port Samt Lvucie, FL. 34983 y ,F.., Pa a 14 Detailed ROOM Loads -:Room:l:= Living (Average1oad. Procedure)''.", General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 24.8 ft. System Number: 1 Room Width: 15.0 ft. Zone Number: 1 Area: 372.0 sq.ft. Supply Air: 115 CFM Ceiling Height: 11.0 ft. Supply Air Changes: 1.7 AC/hr Volume: 4,092.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 9 CFM Runout Air: 115 CFM Percent of Supply.: 8 % Runout Duct Size: 6 in. Actual Summer Vent.: 8 CFM Runout Air Velocity: 583 ft./min. Percent of Supply: 7 % Runout Air Velocity: 583 ft./min. Actual Winter Infil.: 14 CFM Actual Loss: 0.217 in.wg./100 ft. Actual Summer Infil.: 7 CFM Item Area -U-- Htg " Sen -Cl g Lat Sen'. Description Quantity Va{tie°" HTM ;::, Bass.:': HTM . ': Gain., ` Gain S -Wall-13A-4ocs 24.8 X 8 132.4 0.143 4.3 568 2.2 0 290 S-Door-11 D 3 X 7 21 0.390 11.7 246 10.1 0 213 S-Door-11 D 3 X 7 21 0.390 11.7 246 10.1 0 213 S -GIs-1A-cb-o shgc-0.35 1 00%S 24 0.650 19.5 468 17.1 0 410 (2) UP-Ceil-16C-30 24.8 X 15 372 0.032 1.0 357 1.3 0 476 Floor-22A-ph 25 ft..Per. 25 1.358 40.7 1,019 0.0 0 0 Subtotals for Structure: 2,904 0 1,602 Infil.: Win.:13.6, Sum.: 7.0 198 2.268 450 0.585 292 1.16 Ductwork: 1,359 799 Room Totals: 4,713 292 2,517 Rhvac Residential & Light Commercial HVAC Loads Elite Software DeXelopment, Inc. KertHumphrey _ James Allan Memft Renovation: Port:Sarnt Lucie FL= 34983 Pa a 11 Detailed Room Loads:.- R, 6bm`2' _ Nook.(AVeMa LiJa�d .Procedure) Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 8.5 ft. Zone Number: 1 Area: 111.0 sq.ft. Supply Air: 9 CFM Ceiling Height: 10.0 ft. Supply Air Changes: 0.5 AC/hr Volume: 1,105.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 9 CFM Percent of Supply.: 4 % Runout Duct Size: 4 in. Actual. Summer Vent.: 1 CFM Runout Air Velocity: 108 ft./min. Percent of Supply: 7 % Runout Air Velocity: 108 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.014 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area " -U- ;.' Htg Seri; CI g Lat' Seri: Descn fiori Quanf .. Va{ue. , , :. , . HTM' :Lass : . - -HTM ' � ,Gain --�. � Gain UP-Ceil-16C-30 13 X 8.5 110.5 0.032 1.0 106 1.3 0 141 Floor-22A-ph 1 ft..Per. 1 1.358 40.7 41 0.0 0 0 Subtotals for Structure: 147 0 141 Infil.: Wn.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 60 66 Room Totals: 207 0 207 Rhvac Residential & Light Commercial HVAC Loads Ken Humphrey - _ Elite Software DeveIopment, Inc. James_ Allan Merritt Renovafion Port Samt Lucie FL 34983. Pa e'12 Retailed Room Loads Room 3 =Kitchen (Average Loac1 Procedure) . General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 12.3 ft. Zone Number: 1 Area: 160.0 sq.ft. Supply Air: 123 CFM Ceiling Height: 11.0 ft. Supply Air Changes: 4.2 AC/hr Volume: 1,759.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 123 CFM Percent of Supply.: 3 % Runout Duct Size: 7 in. Actual Summer Vent.: 8 CFM Runout Air Velocity: 460 ft./min. Percent of Supply: 7 % Runout Air Velocity: 460 ft./min. Actual Winter Infil.: 8 CFM Actual Loss:- 0.110 in.wg./100 ft. Actual Summer Infil.: 4 CFM Item Area ' -U- Htg Sen :• Clg - Lat Sen I -Description -- -Quantity ,: Value . . HTM :, - - Loss -HTM . Gain,-- Gain N -Wall-I3A-flocs 10 X 11 101 0.143 4.3 433 2.2 0 221 N -GIs-1A-cb-o shgc-0.35 1 00%S 9 0.650 19.5 176 17.1 0 154 UP-Ceil-I6C-3013 X 12.3 159.9 0.032 1.0 154 1.3 0 205 Floor-22A-ph 10 ft..Per. 10 1.358 40.7 407 0.0 0 0 Subtotals for Structure: 1,170 0 580 Infil.: Win.: 7.6, Sum.: 3.9 110 2.264 249 0.582 162 64 Ductwork: 575 858 Equipment: 0 1,200 Room Totals: 1,994 162 2,702 Rhvac Residential & Light Commercial HVAC Loads - Elite$oftware Deyelopment,'.lnc. Ken Humphrey JamesAllan Merritt Renovation Port' Saint Lucie, FL 349i33 Page 13 Detailed Room Loads= Room 4 - Bath 2` (Average Load Procedure) . •General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 13.0 ft. System Number: 1 Room Width: 7.3 ft. Zone Number: 1 Area: 95.0 sq.ft. Supply Air: 28 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.2 AC/hr Volume: 759.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 28 CFM Percent of Supply.: 9 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 319 ft./min. Percent of Supply: 7 % Runout Air Velocity: 319 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.116 in.wg./100 ft. Actual Summer Infil.: 2 CFM 'Item Area -U- Htg _ _ -Sen Clg . Lat'. Sen Descri Lion ,----Quantity'.,, Value HTM : Loss;: HTM Gain, - -Gain N -Wall-I3A-flocs 7.3 X 8 49.4 0.143 4.3 212 2.2 0 108 N -GIs-1A-cb-o shgc-0.35 100%S 9 0.650 19.5 176 17.1 0 154 UP-Ceil-16C-30 13 X 7.3 94.9 0.032 1.0 91 1.3 0 121 Floor-22A-ph 7 ft..Per. 7 1.358 40.7 285 0.0 0 0 Subtotals for Structure: 764 0 383 Infil.: Win.: 4.0, Sum.: 2.1 58 2.260 132 0.582 86 34 Ductwork: 363 194 Room Totals: 1,259 86 611 RhVac Residential & Light Commercial HVAC Load_ s Elite Software Development, Inc. Ken Humphrey James Allan Merritt Renovation - .Pott Saint Lucie FL 34983 Page 14 Detailed Room Loads --'Room 5 = Bedroom 3 (Average Load Procedure) :. General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 14.2 ft. System Number: 1 Room Width: 12.0 ft. Zone Number: 1 Area: 170.0 sq.ft. Supply Air: 101 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.4 AC/hr Volume: 1,363.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 9 CFM Runout Air: 101 CFM Percent of Supply.: 9 % Runout Duct Size: 6 in. Actual Summer Vent.: 7 CFM Runout Air Velocity: 513 ft./min. Percent of Supply: 7 % Runout Air Velocity: 513 ft./min. Actual Winter Infil.: 14 CFM Actual Loss: 0.169 in.wg./100 ft. Actual Summer Infil.: 7 CFM Item Area.; _U= Htg; Sen CIg Lat Sen Description Quantit Value' - HTM ; - Loss;: HTM - Gain , Gain N -Wall-13A-4ocs 12 X 8 81 0.143 4.3 347 2.2 0 177 E -Wall-I3A-flocs 14.2 X 8 98.6 0.143 4.3 423 2.2 0 216 N -GIs-1A-cb-o shgc-0.35 1 00%S 15 0.650 19.5 293 17.1 0 257 E -GIs-1A-cb-o shgc-0.35 33%S 15 0.650 19.5 293 34.7 0 520 UP-Ceil-I6C-3014.2 X 12 170.4 0.032 1.0 164 1.3 0 218 Floor-22A-ph 26 ft..Per. -._. _...._._. ........... 26 1.358 - _.. ___.. 40.7 1,059 -..-.._. _ ......_.... . �_.... ......... .. 0.0 ---._.. ...._..._ 0 0 Subtotals for Structure: 2,579 0 1,388 Infil.: Win.: 14.4, Sum.: 7.4 210 2.266 475 0.587 309 123 Ductwork: 1,238 703 Room Totals: 4,292 309 2,214 Rhvac Residential & Light Commercial HVAC Loads' Elite Software Development, Inc.` Ken Humphrey James Allan Merritt Renovation .Port -Saint Lucie, FL 34983 Page 15 Detailed Room Loads'- Roan'6'. Bedroom2 (Average Load'Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 15.0 ft. System Number: 1 Room Width: 14.0 ft. Zone Number: 1 Area: 210.0 sq.ft. Supply Air: 154 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 5.5 AC/hr Volume: 1,680.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 10 CFM Runout Air: 154 CFM Percent of Supply.: 7 % Runout Duct Size: 7 in. Actual Summer Vent.: 10 CFM Runout Air Velocity: 576 ft./min. Percent of Supply: 7 % Runout Air Velocity: 576 ft./min. Actual Winter Infil.: 16 CFM Actual Loss: 0.171 in.wg./100 ft. Actual Summer Infil.: 8 CFM Item area- -U- . Htg Sen ; Clg,- Lat Sen Description Quanti , Value- - HTM Loss HTM= Gain Gain E -Wall-I3A-flocs 14 X 8 97 0.143 4.3 416 2.2 0 212 S -Wall-13A-flocs 15 X 8 90 0.143 4.3 386 2.2 0 197 E -GIs-lA-cb-o shgc-0.35 33%S 15 0.650 19.5 293 34.7 0 520 S -GIs-1A-cb-o shgc-0.35 100%S 30 0.650 19.5 586 17.1 0 514 (2) U P-Ceil-1 6C-30 15 X 14 210 0.032 . 1.0 202 1.3 0 269 Floor-22A-ph 29 ft..Per. 29........ - ..1.358.._.._ .._ .._._.40.7------- - 1'181 0.0 - 0--- ..- .....0 Subtotals for Structure: 3,064 0 1,712 Infil.: Win.: 16.0, Sum.: 8.2 232 2.267 526 0.586 342 136 Ductwork: 1,455 1,073 People: 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 5,045 742 3,381 Rhvae - Residential & Light Commercial HVAC Loads , —Elite Software Development, Inc. Ken Humphrey James'Allan Merritt Renovation .Port Saint Lucie FL U983 Page 16 Detailed Room Loads *. Room T '. Dining (Average Load Procedure) General Calculation Mode: Hig. & clg. Occurrences: 1 Room Length: 19.3 ft. System Number: 2 Room Width: 14.5 ft. Zone Number: 2 Area: 280.0 sq.ft. Supply Air: 172 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.6 AC/hr Volume: 2,239.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 11 CFM Runout Air: 86 CFM Percent of Supply.: 6 % Runout Duct Size: 5 in. Actual Summer Vent.: 11 CFM Runout Air Velocity: 631 ft./min. Percent of Supply: 7 % Runout Air Velocity: 631 ft./min. Actual Winter Infil.: 13 CFM Actual Loss: 0.326 in.wg./100 ft. Actual Summer Infil.: 7 CFM Item Area -U- : Htg : Sen.. _ Clg Lat Sen Description - 1. Quantity.' Value HTM : --Loss • HTM Gain ; Gain E -Wall-13A-flocs 19.3 X 8 124.4 0.143 4.3 534 2.2 0 272 N -Wall-13A-flocs 10 X 8 50 0.143 4.3 215 2.2 0 109 E -GIs-1A-cb-o shgc-0.35 33%S (2) 30 0.650 19.5 586 34.7 0 1,040 N -GIs-10A-m shgc-0.35 100%S (2) 30 0.650 19.5 586 17.1 0 514 UP-Ceil-16C-3019.3 X 14.5 279.8 0.032 1.0 269 1.3 0 358 Floor-22A-ph 29 ft..Per. 29 1.358 40.7 1,181 0.0 0 0 Subtotals for Structure: 3,371 0 2,293 Infil.: Win.: 12.5, Sum.: 6.7 234 1.758 412 0.474 279 111 Ductwork: 1,484 1,180 AED Excursion: 196 Room Totals: 5,267 279 3,780 Rhvac Residential 1£ Light Commercial HVAC Loads Ken Humphrey Elite Softwrare Development,.lnc. James Allan Memft Renovation Port Saint Lucie FL 34 63" Page 17 Detailed Room Loads - Room 8 ' Wa1k in 'Closets' (Average "Load Procedrare) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 18.5 ft. System Number: 2 Room Width: 7.0 ft. Zone Number: 2 Area: 130.0 sq.ft. Supply Air: 34 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.0 AC/hr Volume: 1,036.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 5 CFM Runout Air: 34 CFM Percent of Supply.: 14 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 390 ft./min. Percent of Supply: 7 % Runout Air Velocity: 390 ft./min. Actual Winter Infil.: 3 CFM Actual Loss: 0.173 in.wg./100 ft. Actual Summer Infil.: 2 CFM Item Area -U- Htg Sen Clg : Lat Sen Description Quantity Value. HTM -Loss; - HTM . Gain:,- Gain W -Wall-13A-flocs 7.5 X 8 60 0.143 4.3 257 2.2 0 131 S -Part-15'/15°-12E-0sw 18.5 X 8 148 0.068 1.0 151 1.0 0 151 UP-Ceil-16C-3018.5 X 7 129.5 0.032 1.0 124 1.3 0 166 Floor-22A-ph 26 ft..Per. 26 1.358 40.7 1,059 ........._......._.. _...._.._..._.__............ 0.0 0 _.__........... _......... 0 _._...... Subtotals for Structure: 1,591 0 448 Infil.: Win.: 3.2, Sum.: 1.7 60 1.767 106 0.467 72 28 Ductwork: 666 234 AED Excursion: .... .. _._.. .._._ 39 .._..__... . Room Totals: 2,363 72 748 Rhvac Residential t£ Light Commercial HVAC Loads Ken Humphrey Elite Software Development, Inc. James'Allan Merritt Renovation_ .Port Saint Lucie FL N983 Page 18 Detailed Room Loads:., -Room 9 = -Master Bedroom (Average Load Procedure),: = Genera! Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 18.5 ft. System Number: 2 Room Width: 17.5 ft. Zone Number: 2 Area: 324.0 sq.ft. Supply Air: 172 CFM Ceiling Height: 12.0 ft. Supply Air Changes: 2.7 AC/hr Volume: 3,885.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 8 CFM Runout Air: 86 CFM Percent of Supply.: 5 % Runout Duct Size: 5 in. Actual Summer Vent.: 11 CFM Runout Air Velocity: 631 ft./min. Percent of Supply: 7 % Runout Air Velocity: 631 ft./min. Actual Winter Infil.: 11 CFM Actual Loss: 0.327 in.wg./100 ft. Actual Summer Infil.: 6 CFM Item Area -U- Htg „ Sen Clg Lat :, Sen Description Quantity', Value'; � HTM -Loss . HTM Gain.: Gain W -Wall-13A-4ocs 17.5 X 12 180 0.143 4.3 772 2.2 0 394 W -GIs-lA-cb-o shgc-0.35 33%S 30 0.650 19.5 586 34.7 0 1,040 (2) UP-Ceil-16C-3018.5 X 17.5 323.8 0.032 1.0 311 1.3 0 414 Floor-22A-ph 18 ft..Per. 18 1.358 40.7 733 0.0 0 0 Subtotals for Structure: 2,402 0 1,848 Infil.: Win.: 11.2, Sum.: 6.0 210 1.757 369 0.471 250 99 Ductwork: 1,087 1,181 AED Excursion: 196 People: 200 lat/per, 230 sen/per: 2 400 460 Room Totals: 3,858 650 3,784 Rhvac Residential & Light Commercial HVAC Loads Ken Humpliiey _ _ ; ` Elite Software Development, Inc. James_ Allan Merritt Renovation -Port Saint Lucie , FL 34983 . Pa a 99 Detailed Room Loads- Room .10 - Master Bath (Average Load Procedure) ' - Genera! Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 18.5 ft. System Number: 2 Room Width: 10.0 ft. Zone Number: 2 Area: 185.0 sq.ft. Supply Air: 84 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.4 AC/hr Volume: 1,480.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 4 CFM Runout Air: 84 CFM Percent of Supply.: 5 % Runout Duct Size: 5 in. Actual Summer Vent.: 6 CFM Runout Air Velocity: 620 ft./min. Percent of Supply: 7 % Runout Air Velocity: 620 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.315 in.wg./l00 ft. Actual Summer Infil.: 2 CFM item Area -U- '. Htg - Sen ,, CIO . Lat . Sen Description - - . Quantity Value' HTM ' Loss;, HTM-.' Gain - - Gain W -Wall-13A-4ocs 10 X 8 57.5 0.143 4.3 247 2.2 0 126 W -GIs-lA-cb-o shgc-0.35 33%S 22.5 0.650 19.5 439 34.7 0 780 UP-Ceil-16C-30 18.5 X 10 185 0.032 1.0 178 1.3 0 237 Floor-22A-ph 10 ft..Per. 10 1.358 40.7 407 0.0 0 0 Subtotals for Structure: 1,271 0 1,143 Infil.: Win.: 4.3, Sum.: 2.3 80 1.763 141 0.475 95 38 Ductwork: 554 580 AED Excursion: 96 Room Totals: 1,966 95 1,857 Rhvac Residential & Light Commercial HVAC Loads',Elite Ken- Humphrey Software Development, Inc. James'Allan Merritt Renovation • Port Saint -Lucie FL' 34983.. Pa a 20 Detailed Room Loads = Room I = Utility (Allerage Load Procedure) -General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 12.5 ft. System Number: 2 Room Width: 9.5 ft. Zone Number: 2 Area: 119.0 sq.ft. Supply Air: 32 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 2.0 AC/hr Volume: 950.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 0 CFM Runout Air: 32 CFM Percent of Supply.: 1 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 370 ft./min. Percent of Supply: 7 % Runout Air Velocity: 370 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.157 in.wg./100 ft. Actual Summer Infil.: 0 CFM Item Area -U= Htg ' - Sen . Cig Lat-. Sen Description QdantiN,a Value HTM Loss HTM Gain,;.- Gain UP-Ceil-I6C-30 12.5 X 9.5 118.8 0.032 1.0 114 1.3 0 152 Floor-22A-ph 1 ft..Per. 1 1.358 40.7 41 0.0 0 0 Subtotals for Structure: 155 0 152 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 61 222 AED Excursion: 37 Equipment: -- _........_......._.. 300 ......... 300 -._. Room Totals: 216 300 711 [Rhvac Residential & Light Commercial HVAC Loads Ken Humph ey Elite Software Development, Inc. James Allan Merritt Renovation Port -Saint Lucie FL 34983 - Page 21 Detailed Room Loads = Room 12 - Bath 3"(Average Load Procedure) = . General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 9.5 ft. System Number: 2 Room Width: 6.0 ft. Zone Number: 2 Area: 57.0 sq.ft. Supply Air: 37 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 4.9 AC/hr Volume: 456.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 3 CFM Runout Air: 37 CFM Percent of Supply.: 8 % Runout Duct Size: 4 in. Actual Summer Vent.: 2 CFM Runout Air Velocity: 423 ft./min. Percent of Supply: 7 % Runout Air Velocity: 423 ft./min. Actual Winter Infil.: 4 CFM Actual Loss: 0.203 in.wg./100 ft. Actual Summer Infil.: 2 CFM Item Area -U- , Htg `, Sen . CIg Lat Sen Descri lion Quantity: Value - ::HTM Loss. HTM , Gain;'- Gain W -Wall-13A-flocs 9.5 X 8 67 0.143 4.3 287 2.2 0 147 W -GIs-IA-cb-o shgc-0.35 55%S 9 0.650 19.5 176 28.9 0 260 UP-Ceil-I6C-30 9.5 X 6 57 0.032 1.0 55 1.3 0 73 Floor-22A-ph 10 ft..Per. 10 1.358 40.7 407 _................... .................. 0.0 .... .......... 0 -...... 0 ___........ Subtotals for Structure: 925 0 480 Infil.: Win.: 4.1, Sum.: 2.2 76 1.763 134 0.474 91 36 Ductwork: 415 253 AED Excursion: 42 Room Totals: 1,474 91 811 Rhvac Residential & Light Commercial HVAC Loads Ken Humphrey .- Elite Software Development, Inca James'A_llan Merritt- Renovation Port Saint Lucie FL 34983 Page 22 -Detailed Room `Loads:_ Room 13 - Rec Room (Average Load Procedure) General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 23.0 ft. System Number: 2 Room Width: 20.0 ft. Zone Number: 2 Area: 460.0 sq.ft. Supply Air: 202 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 3.3 AC/hr Volume: 3,680.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 2 Actual Winter Vent.: 18 CFM Runout Air: 101 CFM Percent of Supply.: 9 % Runout Duct Size: 6 in. Actual Summer Vent.: 13 CFM Runout Air Velocity. 515 ft./min. Percent of Supply: 7 % Runout Air Velocity: 515 ft./min. Actual Winter Infil.: 27 CFM Actual Loss: 0.170 in.wg./100 ft. Actual Summer Infil.: 14 CFM Item Area., -U- 'Htg Sen Clg � Lat Sen Description Quantify : Value ., HTM Loss,-- HTM : Gain ° - Gain W -Wall-13A-4ocs 20 X 8 148 0.143 4.3 635 2.2 0 324 N -Wall-I3A-flocs 23 X 8 163 0.143 4.3 699 2.2 0 357 E -Wall-13A-4ocs 20 X 8 148 0.143 4.3 635 2.2 0 324 N-Door-11 D 3 X 7 21 0.390 11.7 246 10.1 0 213 W -GIs-IA-cb-o shgc-0.35 41 %S 12 0.650 19.5 234 32.5 0 390 E -G Is-1 A cb-o shgc-0.35 41 %S 12 0.650 19.5 234 32.5 0 390 UP-Cell-16C-30 23 X 20 460 0.032 1.0 442 1.3 0 589 Floor-22A-ph 63 ft..Per. 63 1.358 40.7 2,567 0.0 0 0 Subtotals for Structure: 5,692 0 2,587 Infil.: Win.: 26.9, Sum.: 14.5 504 1.760 887 0.474 601 239 Ductwork: 2,580 1,387 AED Excursion: 230 Room Totals: 9,159 601 4,443 Rhvac Residential & Light Commercial HVAC Loads Ken Humphrey, ' . Elite Software Development, Inc. James Allan Memtt Renovation Port Saint Lucie FL 34983. Pa e23 Detailed Room Loads - R00M- '.14 = Hall (Average Load Procedure) ' General Calculation Mode: Htg. & clg. Occurrences: 1 Room Length: 25.4 ft. System Number: 2 Room Width: 3.0 ft. Zone Number: 2 Area: 76.0 sq.ft. Supply Air: 15 CFM Ceiling Height: 8.0 ft. Supply Air Changes: 1.5 AC/hr Volume: 610.0 cu.ft. Required Vent.: 0 CFM Number of Registers: 1 Actual Winter Vent.: 1 CFM Runout Air: 15 CFM Percent of Supply.: 7 % Runout Duct Size: 4 in. Actual Summer Vent.: 1 CFM Runout Air Velocity: 170 ft./min. Percent of Supply: 7 % Runout Air Velocity: 170 ft./min. Actual Winter Infil.: 0 CFM Actual Loss: 0.035 in.wg./100 ft. Actual Summer Infil.: 0 CFM !tern Area -U- Htg Sen , Glg Lat Sen Descri lion . Quartti Value - HTM ; Lass HTM Gain Gain S -Part-15'/15°-12E-0sw 5 X 8 19 0.068 1.0 19 1.0 0 19 S-Door-11 P 3 X 7 21 0.290 4.4 91 4.4 0 91 UP-Ceil-16C-30 25.4 X 3 76.2 0.032 1.0 73 1.3 0 98 Floor-22A-ph 5 ft..Per. 5 1.358 40.7 204 0.0 0 0 Subtotals for Structure: 387 0 208 Infil.: Win.: 0.0, Sum.: 0.0 0 0 0 0 0 0 Ductwork: 152 102 AED Excursion: 17 Room Totals: 539 0 327 --Zmnm1-- 1 Living 372 4,713 61 1-6 583 2,517 202 115 115 2 Nook 111 207 3 1-4 108 207 Q 9 9 3 Kitchen 160 1.994 26 1-7 480 2.702 162 123 123 � 4 Bath 95 1.269 16 1-4 319 611 86 28 38 / 5 Bedroom 3 170 4.292 56 1-8 613 2,214 308 101 101 8_Bedroom 221O5jJ45 GG 1-7576 3.381742164 154_ Ventilation 1,154 577 1.453 _. Duct Latent 1,02G__ System 1total 1.118 18,66422812,208 /[080528520 System 1 Main Trunk Size: 8x13 in. Velocity: 651 ft./min Loss per 1OOft.: 0.089 inmg Fc-odring system summary. Cooling, $ensible/Latent;� Sensible' Latent Total To split i" Btuh � Net Required: 1.36 7596/25% 12,208 4,080 16,288 Recommended: 1.38 75S6/2596 12,239 4,080 16^319 Type: Two Speed Heat Pump Model: RXBH17A05J Indoor Model: Brand: RHEBNCLASSC Description: HEAT PUMP Efficiency: Hi: Q/Lo:QCOP Comment: HSPF9'D Sound: Capacity: Hi: 18,6DO/Lo:QBtoh Sensible Capacity: n/m Latent Capacity: n/m AR/Reference No': n/a Cooling System Standard Air Conditioner RHEEM CLAGC CENTRAL AIR 14SEER 18,6OOBtuh 13,75OBtuh I , Rhvac Residential &Light Gommerclal HVAC Loads Elite'Software Development, inc. Ken Humphrey - mesMemtt Renovation- Port':Samt Lucie FL 34983 Pa a 25; System-2 Room Load Summary T Htg Min; Run Run Clg Clg ; Min Act Room Area } Sens Ht .l. Duct Duct Sens Lat .' CI S g. s g . Ys No ;, Name SF Btuh CFM Size Vet' Btuh Btuh„ . CFM ; CFM. —Zone 2- 7 Dining 280 5,267 68 2-5 631 3,780 279 172 172 8 Walk in Closets 130 2,363 31 1-4 390 748 72 34 34 9 Master Bedroom 324 3,858 50 2-5 631 3,784 650 172 172 10 Master Bath 185 1,966 26 1-5 620 1,857 95 84 84 11 utility 119 216 3 1-4 370 711 300 32 32 12 Bath 3 57 1,474 19 1-4 423 811 91 37 37 13 Rec Room 460 9,159 119 2-6 515 4,443 601 202 202 14 Hall 76 539 7 1-4 170 327 0 15 15 Ventilation 1,649 824 2,075 Duct Latent 1,474 „ System 2 total __.._._.:. __.1,631 26,490 323 - _.. ......... 17 285 -' ...... _... 5 638 _...! . ....... _.. 749 _......_........._..... 749 System 2 Main Trunk Size: 1 0x1 5 in. Velocity: 719 ft./min Loss per 100 ft.: 0.092 in.wg Caolin -S stem Summa ' . , Cooling . :, -, Sensible/Latent .-" Sensible ,: _ - Latent,;; `_ _ Total ' Tons "_ S iit:; Btuh,' Btuh '_: _- Btuh Net Required: 1.91 75% / 25% 17,285 5,638 22,923 Recommended: 1.92 75% / 25% 17,285 5,762 23,047 Actual: 1.97 74% / 26% 17,450 6,150 23,600 Equip ment Data " Heating System Coolinq System Type: Two Speed Heat Pump Standard Air Conditioner Model: RXBH17A05J Indoor Model: Brand: RHEEM CLASIC Description: CENTRAL AIR Efficiency: Hi: 0 / Lo: 0 COP 14 SEER Comment: HSPF 8.9 Sound: Capacity: Hi: 0 / Lo: 0 Btuh 23,600 Btuh Sensible Capacity: n/a 17,450 Btuh Latent Capacity: n/a 6,150 Btuh ARI Reference No.: n/a