HomeMy WebLinkAbout1910-0457 - FLOOR PLAN 12-3-19PROJECT DATA: NAME: SAMPSON TENANT IMPROVEMENT ADDRESS: 21001 ORANGE AVE. FORT PIERCE, FL BUILDING AREA OFFICE 716 SQ.FT. RESTROOM 87 SQ. FT. 15T FLOOR STORAGE (CLOSETS) 46 SQ. FT. 2"D FLOOR STORAGE 849 SQ, FT. EXIST STORAGE 2905 SO. FT. TOTAL BUILDING AREA 4603 SQ. FT. OCCUPANCY CLASSIFICATION: STORAGE (S-1) OCCUPANCY LOAD PER FBC TABLE 1004.1.2: OFFICE: 716 SQ. FT. / 100 = 7.16 PEOPLE STORAGE (1ST & 2"D FL): 3800 SO FT. / 500= 7.6 PEOPLE m AT nr TTvenrtIV• 15PEOPLE CONSTRUCTION TYPE: VB ALLOWABLE AREA PER FBC TABLE 506.2: 9000 SQ. FT. BUILDING IS NON-SPRINKLERED TENANT SEPERATION BETWEEN SPACES PER FBC TABLE 508,4: NO SEPERATION REQUIRED REQUIREMENTS FOR AREA OF IMPROVEMENTS REQUIRED NUMBER OF FIXTURES PROVIDED NUMBER OF FIXTURES 1 WATER CLOSET 1 ADA WATER CLOSET I LAVATORY 1 ADA LAVATORY 1 SERVICE SINK 1 SERVICE SINK 1 DRINKING FOUNTAIN 1 DRINKING FOUNTAIN REQUIRED EXIT WIDTH PROVIDED EXIT WIDTH 36" 72" REQUIRED NUMBER OF EXITS PROVIDED NUMBER OF EXITS 2 2 TRAVEL DISTANCE ALLOWED TRAVEL DISTANCE PROVIDED 100 FT' "FT SCOPE OF WORK CONSTRUCT TENANT IMPROVEMENT ON INTERIOR OF EXISTING METAL BUILDING PER PLAN. INSTALL 2 NEW WINDOWS PER PLAN, NOTE 2"D Fj OOR HAS EXISTING MEZZANINE STRUCTURAL, ONLY TO BE FRAMED IN AS PER PLAN. NOTE: ALL CONSTRUCTION MUST COMPLY WITH THE FLORIDA BUILDING CODE 2017, 2017 PLUMBING CODE, 2017 ACCESSIBILITY, 2017 MECHANICAL CODE AND THE NEC, (NFPA 70) 2014 EDITION. ALL ADDITIONS, REPAIRS, AND ALTERATIONS MUST COMPLY WITH THE F.B.0 2017 FOR EXISTING BUILDINGS. NOTE: THIS BUILDING IS NOT PROVIDED WITH FIRE SPRINKLER SYSTEM, AND IT IS NOT PROPOSED TO BE PROVIDED WITH FIRE SPRINKLER SYSTEM. WALL AND CEILING FIMSH REQUIREMENTS: UNLESS OTHERWISE NOTED ALL WALL AND CEILING FINISHES SHALL BE CLASS A: FLAME SPREAD INDEX 0-25; SMOKE -DEVELOPED INDEX 0-450. COUNTERTOP 1) H.C. COUNTER AT BREAK ROOM SHALL COMPLY WITH FBC ACC 904.4, COUNTER TO BE 3411MEASURED FROM FINISHED FLOOR ELEVATION AND BE 30" MINIMUM WIDE. H.C. COUNTER TO HAVE KNEE AND TOE CLEARANCE PER FBC ACC 305. NOTES: -THE CONTRACTOR, SUBCONTRACTOR, SUPPLIER, ECT. SHALL VERIFY ALL DIMENSIONS, CONDITIONS AT JOB SITE, PLANS, SPECIFICATIONS, ECT. -STRUCTURAL FEATURES NOT DETAILED ON THESE PLANS WILL BE ADDRESSED BY THE ENGINEER AS CONSTRUCTION PROGRESSES. -ALL WRITTEN DIMENSIONS ON THESE DRAWINGS TAKE PRECEDENCE OVER SCALED DIMENSIONS, STRUCTURAL NOTES 1) DESIGN LOADS IN ACCORDANCE WITH ASCE7-10. 2) ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. 3) SPLITING OR CRACKING OF STRUCTURAL COMPONENTS DUE TO INSTALATION OF HARDWARE IS NOT PERMITED. 4) UNLESS OTHERWISE NOTED, THE INSTALLATION OF SPECIFIED HARDWARE' SHALL CONFORM TO THE MANUFACTURES INSTRUCTIONS AND STANDARD PRACTICIES. 5) ALL STRUCTURAL LUMBER TO BE SYP##2. WALL FINISH / INSULATION NOTES 1) ALL INTERIOR GYPSUM BOARD TO BE MIN.%- THICK WITH (13 GAGE, 13/8" LONG,19/64" HEAD; 0,098" DIAMETER,1 Yd' LONG, ANNULAR -RINGED; 5D COOLER NAIL, 0,086" DIAMETER, 1518" LONG,15164" HEAD; OR GYPSUM BOARD NAIL, 0.086" DIAMETER, 1 5/8" LONG, 9/32" HEAD) SPACED AT 7" O.C. FOR NAILS AND 12" O.C. FOR SCREWS. 2) WALLS AT SHOWER TO BE TILE. PROVIDE CEMENT, FIBER -CEMENT OR GLASS MAT GYPSUM BACKERS IN COMPLIANCE WITH ASTM C 1288, C 1325, C 1178, OR C 1278 AND INSTALLED IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AS BACKERS FOR WALL TILE IN TUB AND SHOWER AREAS AND WALL PANELS IN SHOWER AREAS. (PER FIRE 702.4.1 & FRC 702.4.2). 3) ALL GYPSUM BOARD MATERIALS AND ACCESSORIES SHALL CON1 4M TO ASTM C36, C 79, C 475, C $14, C 630, C 931, C 960, C 1002, C 1047, C 1177, C 1178, C 1278, C 1395, C 1390 OR C 1658 AND SHALL BE INSTALLED IN ACCORDANCE WITH THE PROVISIONS pF F1RC, AND ADHESIVES FOR THE INSTALLATION OF GYPSUM BOARD SHALL CONFORM TO ASTM C 557 4) INSULATION MATERIALS, INCLUDING FACINGS, SUCH AS VAPOR RETARDERS OR VAPOR PERMEABLE MEMBRANES INSTALLED WITHIN FLOOR -CEILING ASSEMBLIES, ROOF -CEILING ASSEMBLIES, WALL ASSEMBLIES, CRAWL SPACES AND ATTICS SHALL HAVE A FLAME SPREAD INDEX NOT TO EXCEE9 25 WITH AN ACGp A"VQj $M[PKE-DEVELOPEp 1NDFON NQT TO "fPFD 1P WHEN TEST O I �VfQ"4NCE WITH ASTM E 84 OB UIq 723, L1&44-T _Y vlt&&6i Pa19e� wo2+C C � 2 �il2a/l% , WINDOW 'DOOR SCHEDULE 1 54" W X 36" H SINGLE HUNG WINDOW 2 3068 DOOR 3 3068 S.C. DOOR (45 min. fire rated) 4 2868 DOOR 5 4068 81-FOLD DOOR ED EXISTING DOOR 3070 ER EXISTING ROLL UP DOOR s O. O L K ar � O• NS �ii O o lOglB a _4ST B �op�� �d w 6 ��•�'l ,u 0SHEET NUMBER tv = ®V N' I �O (4 \ �''�QFfsslol t splWHAMRK ENGINEERING 09WPOIN G. HUTCHINiON P.E. #70878 11 v 3 LIFE SAFETY SCHEDULE EX EXIT LIGHT WITH BATTERY BACKUP EM EMERGENCY LIGHT WITH BATTERY BACKUP EM/EX EXIT AND EMERGENCY LIGHT COMBO WITH BATTERY BACKUP FE FIRE EXTINGUISHER TRAVELPATH NOTES: THE EXIT DOOR(S) SHALL REMAIN UNLOCKED AT ALL TIMES WHILE THE SPACE IS OCCUPIED. IF THIS IS A SECURITY ISSUE THE EXIT DOOR(S) MAY HAVE EMERGENCY PANIC HARDWARE. ALL LIFE SAFETY EQUIPMENT SFIALL BE TAGGED CURRENT AND IN PROPER WORKING CONDITION. S T 1 vo O pp •'1tp, C sweet wul�e ER _._ a _.. 0 7087 2 W I NCHMARK ENGINEERING / '6� ss ONA��`'G?�\\ 139W PIN G. HUTCHINSON P.E. *708fsoi i u �- w C ZJini u i .J W.N IA — > CL m o QCL i�194- nl� I ELECTRICAL LOAD CALCULATIONS (PANEL EP) PER NEC 1698 S.F. @ 3.5 VA 27 RECPT'S @ 180 VA A/C HEAT REFRIGERATOR SIGN (FUTURE) WATER FOUNTAIN 4 LF STOREFRONT @ 200 VA MISC TOTAL 44953 = 187 A 240 USE: 200 A SERVICE 5943 VA 4860 VA 10000 VA 1200 VA 1200 VA 950 VA 800 VA 20000 VA 44953 VA PANEL: "EP" IMAINS: M.L.O TYPE: SQ. "D" OR ITE I BUS RATING: 1200A, 3W, SN MOUNTING: SURFACE VOLTAGE: 1120 / 240 / 1 / 60 CKT NO. POLES AMPS DESCRIPTION WIRE COND. CKT NO. POLES AMPS DESCRIPTION WIRE COND. 1 2 50 A/C CU #10 1 1/2" 2 2 60 A/C AHU #6 1" 3 4 5 2 30 WATER HEATER #10 1/2" 6 1 20 WATER FNT #12 1/2" 7 8 1 20 LIGHTING / RECPT'S #12 1/2" 9 1 1 20 1 LIGHTING / RECPT'S #12 1/2" 1 10 1 1 20 LIGHTING / RECPT'S #12 1/2" 11 1 20 LIGHTING / RECPT'S #12 1/2" 12 1 20 LIGHTING / RECPT'S #12 1/2" 13 1 20 LIGHTING / RECPT'S #12 1/2" 14 1 20 LIGHTING / RECPT'S #12 1/2" 15 1 20 LIGHTING / RECPT'S #12 1 1/2" 16 1 20 LIGHTING / RECPT'S #12 1/2" 17 1 20 LIGHTING / RECPT'S #12 1/2" 18 1 20 LIGHTING / RECPT'S #12 1/2" 19 1 20 LIGHTING / RECPT'S #12 1/2" 20 1 20 LIGHTING / RECPT'S #12 1/2" 21 1 1 20 1 LIGHTING / RECPT'S #12 1/2" 22 1 20 LIGHTING / RECPT'S #12 1/2" 23 1 20 LIGHTING / RECPT'S #12 1/2" 24 1 20 REFRIG #12 1/2" 25 1 20 LIGHTING / RECPT'S #12 1/2" 1 26 1 1 20 LIGHTING / RECPT'S #12 1/2" 27 - - JBOX WITH PULL STRING - 1" 28 SPACE 29 SPACE 30 SPACE 31 SPACE 32 SPACE 33 SPACE 34 SPACE 35 SPACE 36 SPACE 37 SPACE 38 SPACE 39 SPACE 40 SPACE 41J SPACE 42 SPACE C i� Cal I� 32 -170/41 V �-ZGol ELECTRICAL NOTES - ALL ELECTRICAL INSTALLATIONS AND EQUIPMENT SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE N.E.C. (NFPA 70) AS AMENDED, AND ALL LOCAL & STATE CODES IN FORCE AT THE TIME OF CONSTRUCTION. - GROUND SYSTEM IN ACCORDANCE WITH ARTICLE 250 N.E.C. - ELECTRICAL WIRING SHALL BE COPPER— TYPE THHN OR TYPE THW FOR WIRING WITH IN BUILDING; TYPE THWN UNDERGROUND OR ON BUILDING EXTERIOR. CONDUIT SHALL BE EMT WITH IN BUILDING; PVC UNDERGROUND; GRS FOR SERVICE ABOVE GROUND. - SYSTEM VOLTAGE SHALL BE 120/240 VOLT, SINGLE PHASE. - PANELBOARDS AND LOAD CENTERS SHALL BE SQUARE "D", ITE, OR APPROVED EQUAL. - ALL CONDUCTORS AND BUS BARS SHALL BE COPPER. - ALL MATERIAL SHALL BE U.L. APPROVED. - PROVIDE ALL NECESSARY PERMITS REQUIRED. - PROVIDE TEMPORARY SERVICE FOR USE BY ALL TRADES DURRING CONSTRUCTION: - PROVIDE A TYPEWRITTEN DIRECTORY FOR EACH PANELBOARD OR LOAD CENTER. - PROVIDE ALL EMPTY CONDUIT WITH PULL STRING AS REQUIRED BY PHONE CO. — VERIFY ALL REQUIREMENTS PRIOR TO BIDS. - CONTRACTOR SHALL MAKE FINAL ARRANGEMENTS FOR TELEPHONE AND ELECTRICAL SERVICE. VERIFY TRANSFORMER LOCATION AND SERVICE POINTS FOR ALL UTILITIES PRIOR TO BIDS. - VERIFY ALL EQUIPMENT ELECTRICAL REQUIREMENTS BEFORE INSTALLATION. IE 0 N II fro , 1:1 No C- �gtirf - IN/ai �L1 N Ib1L I 12 E 0 V V � cLM U .' @J Z N Z J LU ..I t ��CL ti E W Meu�-r �22 i'rY4lC�aL-) � 0 Q W Z SCANNEd St Lu e Count Z o � O � GLS N wlbT�r� rk y� � I 'sr - VOA-p .T `J \\\�o �t tH u rlC��ii Cpv CF NT --�.. -, ^ I..-_ .. ,Su �\\OSHEET NUMBER ' W Cn cl ENGINEERING 2 09NCHMARK ENG/��0'FS- O ONA ���`\\ ✓ 13QW POI)N G. HUTCHINSON P.E. #70878 ��//0111110\\�� `P � -- MCP. TiNwr- i n I}GA//4N lul r wd lie K)OTRICIale XA11 Ili 711< 4J �,�Yqy LAB vd. N + 4 I PLUMBING SCHEDULE: To YOr rzie ME -fa AW7 OW } GATE VALVE COLD WATER PIPING HOT WATER PIPING / TEMPERED >/ Tv J - VENT THROUGH WALL DRAIN WASTE VENT PIPING PLUMBING NOTES: VTW Z" ,";mw WNT 1�12" -2 riI F� 1) ALL WORK SHALL BE IN ACCORDANCE WITH THE FBC 2017-PLUMBING - 2) DWV PIPING SHALL BE SCHEDULE 40 PVC. 3) WATER PIPING IN BUILDING SHALL BE ONE OF THE FOLLOWING: TYPE L COPPER. 4) SLEEVE ALL PIPING IN CONTACT WITH CONCRETE OR UNDERGROUND WITHIN BLDG. r' 5) WATER HEATER SHALL HAVE TEMPERED VALVE. 6) WATER CLOSET AND LAVARORY AT H.C. RESTROOM SHALL BE H.C. APPROVED. OUTSIDE AIR SCHEDULE per 2077 FMC TABLE 403.3 VENTILATION EXHAUST NET ACTUAL CFM PIP CFM I M PROVIDE SPACE OCCUPIED OCCUPANCY y pm Na 56" 6 5 0.06 OFFIC! "t cim Na , 79 2 5 012 BRFAR ROOM p dl0 2W dm 0 p 0.08 RlSTROOM t05 L(f0 Na 2 0 0.12 } LIGHT STORAGE GE 6 cfm Na r' 0 STORAGE 0.12 G@ CLOSETS 2tfi clm 2m Cf^ TOTALS 1760 10 — F LLIO [ANIo in 15 I ,�, -4 P So �C�a L !$oo� b�'ai•� Z/� 1l9N x 14" YET ttT HVAC SCHEDULES AND NOTES: EXHAUST FANS SHALL BE GREENHECK OR EQUAL SP SERIES NEW HVAC UNIT SHALL BE TRANE OR EQUAL SPLIT SYSTEM WITH CFM INDICATED AT 0.25 " SP. RUN 6" DIAMETEREXHAUST THRU WALL WITH Wp SCUPPER. DX UNIT, 16.0 SEER MIN., WITH HEAT STRIP AS INDICATED. MAINTAIN 10, SEPARATION FROM ANY O/A INTAKE. UNITS SHALL BE SPLIT SYSTEM 3.5 TON UNIT. LENNOX PAINT ALL HVAC GRILLES/REGISTERS/DIFFUSERS WHITE. 14ACX-041.230* WITH CBA38MV48-330*+TDR, WITH 9 KW HEAT STRIP, 208/230/1/60. PROVIDE OUTSIDE MAKE UP AIR FOR EACH UNIT- SET CFM AT MANUAL "N" REQUIREMENT. MAINTAIN MINIMUM 10' MOUNT NEW UNIT ON STAND WITH PAN WITH DRAIN AND SEPARATION FROM EXHAUST OPENINGS. FLOAT SWITCH FOR UNIT SHUT DOWN. PROVIDE FIRE DAMPERS AT ALL FLOOR / WALL/CEILING PROVIDE THERMOSTAT FOR EACH UNIT - HONEYWELL, TRANE OR EQUAL "ON - AUTO" FAN AND "HEAT/COOL" PENETRATIONS AS MAY BE REQUIRED TO MAINTAIN FIRE SETTINGS. RATINGS OF SAME - VERIFY REQUIREMENTS ( PERTAINS TO ALL DUCTWORK PENETRATIONS). DUCTWORK SHALL HAVE JOINTS AND SEAMS SEALED WITH INSTALL ALL UNITS TO BE COMPLETELY ACCESSIBLE. APPROVED TAPE APPLIED WITH ADHESIVE TO MAKE JOINTS AIR TIGHT. DUCTS SHALL BE REINFORCED FOIL FACED 1-1/2" REFER TO ARCHITECTURAL SECTIONS FOR CEILING HEIGHT FIBERGLASS INSULATION BOARD (R-6 MINIMUM) FLEX DUCT SHALL BE UL 181 THERMAFLEX OR EQUAL WITH RESTRICTIONS - ALL EQUIPMENT AND MATERIALS SHALL FOIL BACK INSULATION. PROVIDE SPIN -IN CONNECTION FIT IN THE SPACE PROVIDED. MAKE MODIFICATIONS AS WITH INVERTER AND VOLUME DAMPER FOR EACH FLEX REQUIRED TO ACCOMPLISH SAME. TAKE -OFF FROM THE MAIN TRUNK DUCTWORK. REGISTERS/GRILLS/DIFFUSERS SHALL BE METALAIRE OR THE CONTRACTOR SHALL FURNISH A COMPLETE MATCHED EQUAL UNLESS OTHERWISE SCHEDULED - ALL ALUMINUM COMPONENT HVAC SYSTEM IN ACCORDANCE WITH THESE CONSTRUCTION UNLESS OTHERWISE REQUIRED TO MEET DRAWINGS, LOCAL CODES, AND THE LATEST EDITIONS OF NFPA FIRE RATINGS. 90A & 90B, ANSI 8-9.1 MECHANICAL REFRIGERATION, SMACNA, ASHRAE, AND STATE OF FLORIDA ENERGY EFFICIENCY CODE SAR'S (SUPPLY AIR REGISTERS) SHALL BE METAL AIR OR FOR BUILDING CONSTRUCTION - EQUAL. SAD'S (SUPPLY AIR DIFFUSERS) SHALL BE SERIES 5000, M-6, S- THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS ANDINSPECTIONS 4, D-5, OF THE SIZES SHOWN. S-1: ONE WAY; S-2: TWO WAY, FROM GOVERNING AGENCIES AND FURNISH A WRITTEN GUARANTEE THAT ALL WORK SHALL BE FREE FROM ETC. UNLESS OTHERWISE NOTED, SAD'S SHALL BE 6" X 6" DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF (UP TO 125 CFM); 9" X9" (130 TO 290 CFM); 24" X 24" FOR 300 ONE YEAR FROM THE DATE OF EQUIPMENT START UP AND CFM AND LARGER. USE M-2 DIFFUSERS FOE DRYWALL FINAL ACCEPTANCE. MANUFACTURER'S INSTRUCTIONS AND CEILINGS. GUARANTEES SHALL BE GIVEN TO THE OWNER. RAG'S SHALL BE TYPE RHF-TB OF THE SIZES SHOWN ON THE THE CONTRACTOR SHALL BE RESPONSIBLE FOR BALANCING THE PLANS. TG'S (TRANSFER GRILLES) SHALL BE 16/16 OR OF THE HVAC SYSTEM TO MEET THE CRITERIA ON THE PLANS AND SHALL RETURN TO THE SITE TO RE -BALANCE THE HVAC SYSTEM SIZES SHOWN ON THE PLANS. PROVIDE I" T/A FILTERS. AFTER OCCUPANCY TO SATISFY SPECIFIC INDIVIDUAL REQUIREMENTS. ewv' j:S aw 4 1, I'zq 1';' i crl� VA f I low I r I i TI n q 9 � I dd � I O IQ In I u ^= U. I11 U U z N Ln Z yc LU C N A LUO C Q acCL ti W Yg I I cfi w P I01 L tyr- US W W NEW D W LL HI Some o z Nk a vIN s Q N1 & Z I$ H Z >I SCANNED o BY In St Lucie Count OC N 1' y I _1 I 62 u i2 5 0 CO 14!�tv C R ��HiUT� ®MP IDR /A\ 1 w. �� �� tis �Cl � �A ! S T C i+t� �,_-_ ___..�^#.�_ .. Ft)u `ILbL�: • a • � OVN NUM6ER a... Pip L 'G �1 NCHMRRK ENGINEERING j/jFsst�i 13PW OIN G. HUTCHINSON P.E. #70878 011 EXISTING STEEL B JOIST 1 ''/z" X 3 5/8" META. RUNNER 1 %2" X 3 5/8" META. STUDS @ 241, O.C. 1 %2" X 3 5/8" META RUNNER WITH %a': 1" EMBED TAPCON 24" O.C. EXISTING CONCRE FLOOR EXISTING ROOF DECK — EXISTING STEEL I -BEAM 1 '/z" X 5 5/8" METAL RUNNER 2X6 WOOD FIRE BLOCKING BETWEEN STUDS 5/8" TYPE-X DRYWALL EACH SIDE 1 ''/z" X 5 5/8" METAL _ STUDS @ 24" O.C. 1 '/2" X 5 5/8" METAL RUNNER WITH/4" X 1" EMBED TAPCONS AT 24" O.C. EXISTING CONCRETE FLOOR OVER METAL DECK OVER EXISTING STEEL BAR JOIST EXISTING STEEL I -BEAM 1 %" X 5 5/8" METAL _ RUNNER 2X6 WOOD FIRE BLOCKING BETWEEN — STUDS 5/8" TYPE-X DRYWALL _ EACH SIDE 1 '/2" X 5 5/8" METAL _ STUDS @ 24" O.C. 1 '/2" X 5 5/8" METAL RUNNER WITH''/."X _ 1" EMBED rAPCONS AT 24" O.C. EXISTING MET, PURLINS AT +/- %2" DRYWALL 1 'h" X 1 %z" ME] PURLINS @ 24" 1 '/z" X 3 5/8" MI RUNNER WITH 1" EMBED TAP( 24" O.G. EXISTING CONi FLOOR LR-30 FIBERGLASS BATTS INSULATION DROP CEILING 2X4 R-13 FIBERGLASS BATTS INSULATION R-30 FIBERGLASS BATTS INSULATION ''/2" C-CORE DRYWALL OVER 12 ga METAL FURRING CHANNELS AT 24" WITH 414 X 2'/2" SMS EACH EXISTING BAR JOIST R-13 FIBERGLASS BATTS INSULATION YPICAL N'Ed WALL SECTION r�;l it/to/ lei FIBERGLASS BATTS :ATION 'ING SIDING 0 nts.. 2X TREAD (12") 1X RISER (6.6") 4X4 WOOD GUARI SUPPORT AT 60" 0 2X12 WD STAIR S1 (1) EACH SIDE AN] O.C. MAX SIMPSON HGAM R SDS Yd' X 1 1/2" ANI X 1 3/4" TITEN EACI STRINGER EXISTING CONCRI FLOOR PROVIDE (2 LAYERS) OF 304 FELT BETWEEN STRINGERS AND CONCRETE 1 '/z" CONTINUOUS HANDRAIL WITH BRACKETS AT 60" O.C. 2X8 CONTINUOUS TOP PLATE 2X4 WOOD TOP PLATE 2X4 WOOD STUDS AT 24" O.C. —'/z" DRYWALL BOTH SIDES 4X4 WOOD POST AT 60" S - 9 O.C. MAX 2X4 )IOTTOM PLATE m 4X4 WITH (2)-'/2" LANDING FFE AND THRU BOLT$ TO STRINGER LEADING EDGE OF STAIR TREAD i/Y TYP. GUARDRAIL / HANDRAIL SECTION nts... 4X4 WOOD GUARDRAIL SUPPORT AT 60" O.C. MAX 2X12 WD STAIR STRINGER (1) EACH SIDE AND 24" O.C. MAX 2X TREAD (12") -- 1 X RISER (6.6") WALL ENTIRE UNDERSIDE OF STAIRS TO BLOCK OFF UNDERSIDE OF STAIRS TYPICAL STAIR SECTION nts... "SIMPSOM" MTS12 WITH (14) — I Od NAILS EACH STAIR STRINGER DBL 2X4 WOOD TOP PLATE 2X4 WOOD STUD AT 16" O.C. WITH SIMPSON SP6 EACH � STUD TOP AN BOTTOM WITH (6)- 10d Yg4 TYPE X DRYWALL BOTH SIDES P.T. 2X4 WOOD BOTTOM PLATE WITH %d' X 3" TAPCONS AT 16" O.C. E O u Z R .. ag LL d LM v LM aU = J u1 Z W C n J m l� W O O IL m E W — WALL/DOOR HAND RAIL / GUARD RAIL -- PER DETAIL (2 LAYerzs) -%" T&G PLYWOOD WITH ' k #10 X 2" SCREWS AT 4" O.C. 2X12 WOOD JOIST AT 24" O.C. WITH "SIMPSON" H3 WITH (8)- 8d NAILS EACH INTERSECTING JOIST BELOW 2X12 WOOD JOIST AT 24" O.C. WITH "SIMPSON" H3 WITH (8)- 8d NAILS EACH W INTERSECTING JOIST � {L BELOW _ W u OUj 1 L A— 2X$ WORD JOIST AT I0" "SIMPSON" 0 O.C. WITH 113 WITH (8)- 8d NAILS EACH END TO WALE, Z ' s a4 DBL 2X6 WOOD TOP W PLATE :r 0 '` Z 2X6 WOOD STUD AT 16" � O.C. WITH SIMPSON SP6 EA414 STUD TOP AND Z BOTTOM WITH (6)- IOd Q l$ TYPE X DRYWALL r BOTH SIDES /0//� L P.T. 2X6 WOOD BOTTOM g N PLATE WITH'/," X 3" TAPCONS AT 16" Q.C. ca t SCANNED IC' BY `tHlu r C/ UZ LO p BENCHMARK ENGINEERING BOWDOIN G. HU'TCHINSON P.E. #70878 TOTAL RISE:10'-0" (120") �St Lucie County (18) RISERS EACH AT 6.6" (17) TREADS EACH AT 12" 0 . 1'/, 1'!s 1 42-M 39 Grab Bar i CLEAR i FLOOR !SPACE b "FCC" D.ETAULS N.Ts 43 BARS X 12" LONG DRILLED OUT & EPDXI[.?I? WITH 6" MINIMUM EMBEDMENT @ 24" O.C. ALL AREAS ADJACENT TO EXISTING FOUNDATION EXISTING CONCRETE FLOOR /FOUNDATION 6" THICK (2500 PSI) CONCRETE SLAB OVER VAPOR BARRIER ON CLEAN COMPACTED CHEMICALLY TREATED FILL �_t ` `I �I�IIl�I�! = ,s,:tL 4t FLOOR REPAIR DETAIL nts.. LOCATED AT ALL AREAS REQUIRED FOR NEW PLUMBING INSTALLATIONS i(' UTU - Planning & Development Services Department Building & Regulations Division ' Product Review Affidavit Building Permit # OwnersName 17L\wnPSoN Applicant: Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass T ype Method of Attachment Windows Mullions + 3}'l -49,4 N /� 4/-55 r»ty 185 4H FI.d IIIMI IMVIu,'( # to >< I v4" !�w•I�eo `co:Qws a'r Fixed Glass Block Glass Skylights Sliding Glass Doors Swing Type Doors French Doors Garage Doors Hurricane Protection Roof Ventilation Roofing Material Revised 07/22/2014 I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: 136w10ota &, Signature: ON PLAu seal Design Prof: 6oN boles G N IJ TCH (NSo/ J Cert. No. '* O 8 4 f) Date: ) o I lr. SECTION EXISTING STEEL PURLIN SIDING TRIM 4" X 4" X 3/16" (30 ksi) STEEL ANGLE WITH (2)- V' THRU BOLTS EACH WAY 6" X I Oga (30 ksi) STEEL C-CHANNEL EACH SIDE OF WINDOW OPENING 2X 6 P.T. WOOD BUCK WITH#10 SMS TO STEEL FRAMING AT 4" O.C. (ALL SIDES, MAY REQUIRE (2)- 2X BUCKS IN SOME AREAS 4" X 4" X 3/16" (30 ksi) STEEL ANGLE WITH (2)-'/2" THRU BOLTS EACH WAY SIDING TRIM EXISTING STEEL PURLIN EXISTING CONCRETE FOUNDATION WINDOW OPENING IN EXIST. WALL nts.... Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: SAMPSON WINDOW OPENING Project Address: 21001 ORANGE AVE. FORT PIERCE, FL Permit #: Occupancy Type: B / S-1 Construction Type: v INSTRUCTIONS FOR USE: * This certification must be completed, signed, and sealed by the design professional of record. * Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code 2017 Edition with 20 _Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed —Partially Enclosed _ Open 3. Risk Category: _ I X II _ III IV Exposure Category: _ B X C _ D 4. Design Wind Velocity 160 mph 124 ASD N/A LRFD End Zone Width: 5 ft S. Mean Roof Height: 25 ft Roof Pitch: o.s :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft Ga 15'MRH, clearly label on all plan openings): N/A N/A N/A 37.1 37.1 N/A Zone 1: Zone 2: Zone 3: Zone 4: -40.3 Zone 5: 49.7 Garage: 7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: _ N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: 100 PSF Fence: N/A PSF Railings: 50/200 PLF / CONCENTRATED 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 20. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Bowdoin G. Hutchinson 70878 ON PLAN 10/16/2019 Signature, Date, and Seal SLCCDV Form # 020-12 Revised 3/15/12 tJS) DETAIL Print Name Cert # & Co. Cart Auth. Benchmark Engineering 806 Delaware Av. Fort Pierce, FL Company Name & Address ��' � • , /ice o �ry Ewa S / TA LO A BENCHMARK ENGINEERING //� Sslo� `� BOWDOIN G. HUTCHINSON P.E. #70878 A r z 4 LLI `z r Z �0�w v/ L Q U) SCANN BY St Lucie C Mi