Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEa" - 6 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION r Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT ' �� Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY ®����%�S City, State, Zip: FT. P RCE , FL , O;t,,,�,�S2 Permit Number: Owner: -1 �� Jurisdiction: Design Location: ,; FL, ST_LUCIE_CO_INTL County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New constructiod 6r existing New (From Plans) 9. Wall Types (1437.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftz b. Frame - Wood, Exterior R=11.0 187.33 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 2 d. N/A R= ftZ 10. Ceiling Types (1446.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ftz 6. Conditioned floor area above grade (ftz) 1446 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(139.2 sqft.) Description Area a. Sup: Attic, Ret -Attic, AH: Attic 6 320 a. U-Factor: Dbl, U=0.54 99.23 ftz SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.55 40.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.586 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1446.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1446.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 46.91 PASS Total Baseline Loads: 48.19 I hereby certify that the plans and specifications covered by Review of the plans and 4'1~KE S7q?. this calculation are i compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. +nra''% -::_'' �`•'�,ti PREPARED Q DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 - I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/MT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. FILE 1 10/23/2017 4:55 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R400-2014 PROJECT Title: THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner: Total Stories: 1 Block/SubDivision: . # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY JVrisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: ' CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 234 1872 No 2 1 1 Yes Yes Yes 2 WIC 54 432 No 0 1 No Yes Yes 3 MASTER BATH 63 504 No 0 1 Yes Yes Yes 4 M.BATH 56 448 No 0 1 Yes Yes Yes 5 KITCHEN 172 1376 Yes 0 1 No Yes Yes 6 BATH 45 360 No 0 1 Yes Yes Yes 7 BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 526 4208 No 0 1 Yes Yes Yes 10 FOYER 50 400 No 0 1 Yes Yes Yes + FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 40 ft 0 234 ft2 ---- 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 54 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ft2 ---- 0 1 0 10/23/2017 4:55 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R406-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 --- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 54 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 5 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 6 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 7 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood 10 Under Attic (Vented) FOYER 30 Blown 50 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 10 MIMI Type_ 1 N=>SE Exterior Concrete Block - Ext InsiBEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block - Ext InsfOEDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block - Ext InsdflEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block - Ext IndMASTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 5 S=>NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 _ 7 N=>SE Exterior Concrete Block - Ext In§ffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 8 E=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0 9 SE=>W Exterior Concrete Block - Ext InfiffDR00M 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0 10 S=>NW Exterior Concrete Block - Ext InSEDROOM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0 11 S=>NW Exterior Concrete Block - Ext Insd1AUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 12 N=>SE Exterior Concrete Block - Ext InsGiREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0 10/23/2017 4:55 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R40S--2014 WALLS - Adjacent Space Cavity Width Height Sheathing Framing Solar Below 13 W=>NE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 21 0 8 14 N=>SE Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 15 E=>SW Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 8 16 N=>SE Exterior Frame - Wood GREAT/DINI 11 23 5 8 0 168.0 ft2 0 8.0 ft2 0 48.0 ft2 187.3 ft2 0 0 0.5 0 0 0.5 0 0 0.5 0.23 0.5 0 0 0 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V # Ornt ID Frame Panes NFRC U-Factor SHGC Overhang Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Double Yes 2 S=>NW 5 Metal Low-E Double Yes 3 E=>SW 8 Metal Low-E Double Yes 4 N=>SE 12 Metal Low-E Double Yes 5 W=>NE 13 Metal Low-E Double Yes 0.54 0.25 0.54 0.25 0.54 0.25 0.54 0.25 0.55 0.25 32.4 ft2 1 ft 0 in 6.9 ft2 1 ft 0 in 23.2 ft2 1 ft 0 in 36.8 ft2 1 ft 0 in 40.0 ft2 10 ft 0 in 1 ft 4 in Drapes/blinds 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None 1 ft 4 in None Exterior 5 None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .2669 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 10/23/2017 4:55 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FoRnn R4nq_gnlA HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None • SOLAR HOT WATER SYSTEM FSEC Collector Storage Cent # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS / -- Supply — — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 320 ftZ Attic 80 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[� ]] Jan Heatin[X] Jan [[ ]] Feb [X] Feb [[ ]] Mar [X] Mar [ [ ] Apr j ]Apr j May rj Jun rlJul May Jun Jul Aug AuSep rl Se [ ] [ ]Oct Oct Nov Nov Dec Dec Ventin [[ ]] Jan [[ ]] Feb [[X]] Mar [X] A r May Jun Jul Aug Se [X] Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/23/2017 4:55 PM EnergyGauge@) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/23/2017 4:55 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEVELOPMENT, FT. PIERCE, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftZ 7. Windows- Description a. U-Factor: Dbl, U=0.54 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.25 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftz b. Frame - Wood, Exterior R=11.0 187.33 ft 1 c. N/A R= ftZ 2 d. N/A R= ftZ 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1446.00 ftZ 1446 b. N/A R= ftZ c. N/A R= ftZ Area 11. Ducts R ftZ 99.23 ftZ a. Sup: Attic, Ret: Attic, AH: Attic 6 320 40.00 ftZ 12. Cooling systems kBtu/hr Efficiency ftZ a. Central Unit 34.8 SEER:15.00 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ftZ 13. Heating systems a. Electric Heat Pump 3.586 ft. 0.250 Area 14. Hot water systems 1446.00 ftZ a. Electric ftZ b. Conservation features ftZ None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: d�D Address of New Home: ���"' � � �� City/FL kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.97 Pstat 04Z'E1E STgTG,O.t *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/23/2017 4:55 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 1! � Project Summary oa `- wrightsoft Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-366-6799 Fax 772-466.6796 Email: QUICKCALCS@AQL.COM. For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db . 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 He 1446 Cc 1446 Area ft Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual'airflow . Air flow factor Static pressure Space thermostat Capacity balance point = 32 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 27 0 1160 cfm 0.049 cfm%Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE 90 OF 75 OF 15 OF 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 - Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipmenf sensible load 24753 Btuh Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Airflow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .c. + wrightsoft` 2017-Apr-11 09:29:38 �� RightSuite® Universal 2017 17.0.14 RSU08101 .Page 1 ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N s - wrightsoft' Right-JO Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946-Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House BEDROOM 2 E:gosed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6 13A4ocs.- 0.143 :. n . 4700 2.55 ` ' ' 503 466 . ' 1862 > 1184 72 •' 72 . 268 ' 183 ;4A52dm 0i770 . n" 21:56 . 19i31 " 38 0 815 730 . :" 0 0 " ;0 A 13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 1A-c1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W Vt/ L--G :13A . 13A4ocs 1Ac1am 0.143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 34 360 7 34 353 7 136, 1414 247 86 899 241 0 216 0 0 216 0 -0 865 0 0 550 0 13A4ocs 1Ac1om ' ;4A5 tom 0.143 1.270 .0.770 w w ` w 4.00 35.56, 21.56 2.55 55.21 19.31 310 32 41 237 2 . 41 949 1140 880 603 1770 : 788 104 32 0 .72 2 • - 0 286 1140 0 183 1770 0 P 12C-0sw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 .c, : 4 `�16A=80md ' - 0:032 - 0:90 . 2.32 1446 -1446 1295 ,= 3354 297: 297 266 .689 F ,- 22A tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal pins 6 to 13) 17848 17520 5053 4925 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503 26056 6653 7325 Air required (cfm) 11160 1160 328 326 Calculations approved by ACC , to meet all requirements of Manual J 8th Ed. wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 ,Mpg ...uick CaIcslDocuments\THE GRAND CARLTON-1446.rup Calc = MJB Front Door faces: N Page 1 9 m OX ro O D Z m �L N � V C1 O II A Ca W c 0 � O O O O 0 N Z ' o1A W N p) O UTA WN-+ o O pD :fl (gyp (gyp ur $.� [mil �, -n o.-u �O7 �O0 :p0 Zpl $ o 0 A o jvil 33 .. .N TNAp DW DWW-'D CA 3 N ur �CD �+. 3 p - N3 �n - m ; 0CL O � - �p0o000.-A0-+y0a A0 c0po�.pp p 0.0ID CO �L N VlN CD fD m77 O V.tOpN�. QIA NAA.pA OC71 D� O OA�OA (0000071.0 WO'WOON�O;O� CAS -i ' . CON->•t0 (ll [JAt SJ tptN� O ([J�(fN��V . O.N ONo-W+-N-�m Vma NCD (Wn�-W+N 0co N m� o V too oo OOo oo OO:O 3� a m 0 O x x Z O Z rn O O WOO Oo' 0000000O C x O C co 0 W0 fnA000 oo OD OAoo CD o OO oo ooO �� TO. ODA 0V000 V 00 00 V to .O (Nn00 o000000000, N O 'N N A O. O'O O O CD00000 N 3� x J OD O o x .O No O.00000 OO OCO � x x o0 2 N Z i' >OD SV000 .I oo V p ) .oAi000O.Oo000oD0.FL 11-- oS x . •, ,_ .. _ W W T-000 gN O CO GO 00 O cooN0000000000;G C to 0 ►• 3 ell. O 0 N G cD C n W CD rt - - wrightsoft- Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM 1 Room name BATH BEDROOM 2 2 Exposed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ft2 1.0 x 203.5 ft 203.5 ft2 Ty Construction U-value Or HTM Area (ft5 Load Area (ft2) Load number (13tuh/ft2 °F), (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 . 13AAocs. - 0.143 „ n _: 4:00 2.55 40 40 160 :: 102 128- 128 513 326 .0.770 ri .. 21 5fi ` 19;31, - 0 - 0 - 0 0 0 : 0, 0 : `0 13AAocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143 11 1A-c1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 W .13AAocs 0.143 se 4.00 2.55 0 0 0 0 34 .34 136 86 W L- G 13AAocs 1Ao1om 0.143 1.270 s s 4.00 35.56 2.55 34.77 0 0 0 0 0 0 0 0 32 0 32 0 128 0 81 0 13AAocs ` 0.143 w 4.00 2.55 0 0 0 0 0 0 .0 0 1A clom 1:270 w 35.56 . 55.21 0 0 0 0 0 0 0• 0 F 4A5 tom :. 12C-0sw 0:770 0.091 .w 21:56 2.55 19.31 1.28 0 0 0 0 '. 0 0 0 0 l) 0 t) 0 0 0 0 0 C". 4 -gomd. _ 0.032 - 0.90 2.32 45. 45. 40 104- 204 204. 182_- :. 472 F 22A tpl 0.989 - 27.69 0.00 45 6 138 0 204 34 9.46 0 6 c)AED excursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 1 0 0 Subtotal Pines 6 to 13) 425 214 3571 3498 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 32% 49% 135 104 32% 49%1 1131 1704 Total room load 560 318 4702 5203 Air required (cfm) 28 14 232 232 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. 38 . mk wrrtghtsotFt Right-SuiteG) Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29 Page 3 ...ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wrightsoft' Right-M Worksheet Job: Entire House Date` By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a(AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft' 1.0 x 526.0 ft 526.0 ft2 Ty Construction number U-value (Btuh/ftz°F) Or HTM (Btuh/ft2 Area (fV) or perimeter (ft) Load (Btuh): Area (ftg or perimeter (ft) Load (Btuh) Heat Coal Gross WP/S Heat Cool Gross WPM Heat Cool 6 •yJ L _G 13A�ocs: - : :'_4A5 tom . `- 0A43 O:T/0 •-.n' ri 4'.00 21:56 2.55 19.31. 0 " . 0 - 0 0 0 0 . 0 0 255 . 38 217 ' : '0 -869 :552 730 13A4ocs 0.143 a 4.00 Z55 0 0 0 0 0 0 0 0 11 IA-clom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 'VA-4ocs 13A4ocs 1A-clom 0;143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 0 48 0 0 48 0 0 192 0 0 122 0 0 0 0 0 0 0 0 0 0 0 0 0 13A flocs 1Ac1om:. •4A5 2ohl; . 12C-0sw 0.143 1.270 0.776 0.091 : w ..w • w - 4.00 35.56. 21.56 2.55 2.55 55.21 19.31 1.28 0 0 0 56 0 0 0-- 56 0 0 0 143 0 0 . 0 72 206 0 41 0 165 0 41. 0 661 0, .880 0 420 0 :788 0 P C 16A 30mtl" '0.032 = 0.90 : 2.32 ` 42 42 ': 3t3 9Z : _ 526: .- . "526. 471, .:. • 1220 F 22A tpl 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 0 6 c)AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 2490 Total roomload 846 443 7892 7602 Air required (cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -- wrightsoft- 2017-Apr-11 09:29:38 Ae'r--A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 ...uick Calcs\Documents\THE GRAND CARLTON•1446.rup Cale = MJ8 Front Door faces: N -- wrightsoft° RightJO Worksheet Job: Entire House Date` By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name FOYER M. BATH 2 3 =ed wall Room height 7.0 ft 8.0 ft heat/cool 8.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 50.0 ft 50.0 ft2 7.0 x 8.0 ft 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Stuh/ft'-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Coot Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 ' 13A-flocs- � 4A5 tom ` 13A4ocs : 0:143 :0.770 0.143 n,'. n' . a '4.00' .. 21:56 4.00 ` 2:55 19.31' 2.55 8 0 48 . • 8 0 27 32 0 108 - 20 0 69 0 p 0 0 .. 0 0 0 . 0 0 0 -0 0 1 1Aclom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 W t-G0.143 ..13A4ocs 13A4ocs 0:143 se s 4.00 4.00 2.55 255 0 0 0 0 0 0 0 0 0 64 0 57 0 228 0 145 1Aclom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13AAocs .0.143 w 4.00. 255 0 0 0 .0 0 0 :0 0. Na 1Aclom 4A5 tom . 12C-0sw 1.270 0.770 6.091 w .:w: - 35.56 21.56 2.55 - 55.21 . 19:31 1:28 0 0 72 0 0: 72 0- 0 183 0 .0 92 0 0 0. 0 0. 0 0 0 0 0 .. 0 0 . P ;16A-30md _ . -. 6.0.32. _ 0.90 2.32 50 .50 46 116 56 56 50, ;130 F 22A tpl 0.989 27.69 0.06 50 7 194 0 56 8 222 0 6 c)AED exursion -39 138 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 8851 516 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32% 49% 280 251 Total room load 1202 787 1166 768 Air required (cfm) 59 35 1 581 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 1 -F' wrightsoft' Right -Su te® Universal 2017 17.0.14 RSU06101 2017-Apr-11 09:29:38 leek Page 5 ..uick CalcslDocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wrightsoft� Duct System Summary gat : Entire House By: QUICK CALCS,INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM rroject intormation For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL External static pressure Pressure losses Available. static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 .in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 OxO VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 &0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox 0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 S12 GREAT/DINING-A h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 SO LAUNDRY h 846 42 20 0.861 4.0 Ox 0 VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 VIFx 0 0 WIC c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx 2017-Apr-11 09:29:38 Arckwrightsofta Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in)' . Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) . Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft° R2017-Apr-1109:29:38 ��9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ..uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N