HomeMy WebLinkAboutBUILDING PLAN8'-I" T.O.B.
0'-0' = Finished Floor
Gulf Coast Supply and MFG 5v Crimp Meta roofing FL 411651.12
2L a. 5v crimp metal roofing attached to lgwood deck using 49 x 1.5"
wood screws with self sealing washer at 12" c.c. max spacing over AST!'
(type 2) 30 lb felt underlayment Installed wit h min. 4' side laps and 6"
laps fastened with corrosion resistant tin ca a and with 5" ring shank
spaced L o.c. at all laps and two staggered rows 12" o.c. field. A
deck to trusses using attachment detail on t Is sheet
12
4 F.SLOPE
Ns ,g\n e\.1-oROP C1 QNNur
NS t
P� Ti) AN(�SPECTORSTNA
11REU Ri �Si, v 1nl 1RD@P�arDES,.
rDLV >� i1'tl .
2"
H . .H.
5/8" thick light textured
® ® stu co on typical concrete
block construction
5;8" thick x 8"w cut Finish Columns with
coral fnished stucco bands 5/8" thick cut coral
finished stucco bands
ALLMANUFACTU G OMPLIANOE
U FAOTORS AND Si1MUST
G
WITH FRC ENERGY GODS
HEhryAIN ON pLL DOORS AND WINDONS
UN i INSPEOiTONS ARl" APPROVED
5/8" thick x 8"w cu
coral finished stucco band
LEFT ELEV,47ION =i c\inTinr.i \inT=C�
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12 51,
2L wood-
5v crimp metal roofing attached to plywood eck using #9 x L
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" o.c. at all laps and two staggered rows I o.c. in field. Attach
deck to trusses using attachment detail on this sheet
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL WIL51.12
26 wood"
5v crimp metal roofing attached to plywood deck using 49 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment Installed with min. 4 side laps and V and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
stucco on typical concrete U/ 0 unit1 c.ui, t.Vlui
block construction finished stucco bands
REAR ELEVATiON
- Overhangs at 1'-0" unless otherwise noted on Roof Plan
- Roof pitch at 4:12 unless otherwise noted
- Any changes to this plan shall be submitted to the architect
for approval In writing prior to starting construction.
- Return ALL Stucco Bands Into Window or Door.
1000
IV-0
12
SLOPE] 4
CONCEALED F
4RETHERESPO SRB�T 8e
RA77ACHMENTS
CONTRACTOR OFRECORD
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL UU51.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over A5TM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
?aced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
dpeck to trusses using attachment detail on this sheet
i JH
e'-I" T.O.B.
2
5/8" thick x 8"ll cut
coral finished stucco )ands 'H. ®® .
°
lO
3 5/8" thick x 8"w cut
coral finished stucco bands
�5/8, thick light textured
III t2g:111c:
stucco on typical concrete
block construction - - - -
----------------�--- - - - ------------ - - - - -- 0'-0" = Finished Floor I In Finish Columns wlth 5/8" thick light textured
5/8" thick cut coral stucco on typical concrete
finished stucco bands block construction
RIGHT ELEVATiON
Product Approval
SubTnittal Affidavit
Opening Schedule Swing
Doors, Overhead Doors, Sliding Doors. Windows k Skylights
Opening
NOA/FL
Product
Model #
Manufacturer Glass
Attachment method
Type
NUMBER
G iq. x gpcona W mir� ppnsytet on at mWNcc
car n end L o.c. theraeFter through PT �uck into eold
12,3
FLU 11499.2
Single Hung
Series 185
MI Windows
ram each
a� ��rlemtg min 2.5" edge distance m strict adherence
and doors
di111
spin
Overhead
Model 824/811
9'-4"
DAB
ss be xverr �•a aist"x eL""e-0ltl NLC Sseve eexae rt as ae.
h t2s• ee. r'$set`r w 1• old a ostmiee. InNae v.cc "o 6w,
ersctrt asenmmnw
A
L-0330.02
Garage Door
max. width
IL'-O" max height
w !a 5/Is• x I / IJ thread Iw acre®. m esc
ma a is• sits• es.x. - oc ee .vmtq edirr. to predrt spprwel
0.
W t/IL' mxlmlM1 mmdYr eimr4.
Elco 1/4' dia. tapam with min 1.25• embedment at 3" max
from corners and 11.5"" o.c. max thereafter in and jambs.
B
FLU ILL14.1
Fiberglass
smooth Pro
Jeld-Wan
Sliding Glass
MI Windows
trhead
all deM row thearneeftero the- max.
T ram raft corner and 1p cars
C
FLU 15332.2
Door
Series 420
and doors
PT Suck into sdld hided CMU wall maintaining min 2.5' edge distance
n strict adherence to the product atorovai.
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
For CMU use (2) 1/4' x 2 3/4' tapcons with min 1 1/4" embedment
CM-18531
MI Windows
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
Mullions
FLU 15353.8
vertical mullion
and doors
self tapping screws per chip as shown in product approval.
Roof
FLU 1101.12
5V Crimp
Gulf Coast Supply
2L ge 5v crimp metal roofing attached to pigwood deck using #9 x 1.5"
wood screws with Belt sealing washer at 12' o.c. max abating over ASTM D
Metal Roofing
and manufacturing
ltgpe 2) 30 lb felt underlagment installed with min. 4 side laps and 6" and
laps fastened with corraron resistant tin caps and with 1.25' ring shank nails
spaced G ,; at all ImI and two staggered rows 12' o.c. in field. Attach
deck to trusses using attachment detail on roof plan
SCALE: 1/4" = 1'-0"
2" x 4" top plate
NO IL
Date
on
Design Pressure
of Approved Tests
ALL MANUFkCTUPFS I.ARI_ES SHOWING
UFAOTOHS,iNDS113%I:UMPLUWCE
WrTM FRC ENERG" CODE MUST
REMAIN ON ALL tR)ORS AND WINDOWS
UNTIL INSPECTIONS ARE APPROVED
± 60 psf
10-9-21
+ 50.0/-(0.0 pat
+ 50.0 PSF
+ 48.2 P5F
Ft•
e
n Design Pressure
of Approved Teats
+ 118.9 PSF
- 108.5 PSF
Siding
Stucco on Block
Soffit
FL# 12198.3
Model T4 12" vented
1Caycan
Install using d x 2" battens at us o. I screwed to soffit framing using
x wood screws each truss. Install8" soffit to battens using
5.0 PSF
VIn 1 Soffit
y
.12" dia. x 1.5" ring shank d with /8" ilia.head-
0. di in
Hurricane
24 Gauge
Global Protection
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
washer at 12 I/2" o.c.
± 45.0 PSF
Panels
Flu 15016.2
Storm Panels
Products LLC
alongshesbottomeandc13" o.cdthatNthertop
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of
base -board
OPOSEOWOPK
ALLPP S
tNESe"OsACliROANIcORCT�PSS o
APES \R p B� F\E I \I ORDElk IOODES•
1/2" drywall ceding on truss I \ �ppPUOAR
OMPL� W
1/2" drywall on
2" x 4" studs at W' o.c.
2" x 4" P.T. bottom plate
4" concrete slab with fibermesh OR
L"x6" 410/10 WWM on 6 mil Via ueen over
clean compacted termite treated fill
Interior Non -Bearing Partition
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one lager of 15 lb felt using 8d nails. Substrate
to be 19/32" COX Plywood nailed at C o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
SLOPE 4
1110M
I[ A I
ICI
II�PI
FRONT ELE\/ATiON
SCANNED
BY
St Lucie County
ST. LUCIE COUNTY II IIjG DIVISION
REVIEWED FOR CO PIjANCE
REVIEWED BY
DATE 9�
MT PT OPLANS AND PERT MUSBEKEN]OB
SITE OR NO INSPECTION(S) WILL BE MADE
SCALE: 1/4" = 1'-0"
AN
5/8" thick x 8"w cut
coral finished stucco bands
FILE "
ALL CONTRACTOR WARRANTIES BEGiN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
FERMITTiNG INFORMATION (FORM 100)
Florida Building Code Residential: Sth Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: IL5 mph ultimate
Mean Roof Height: Il�'-O" Roof Pitch: 4:12
Internal 'sressure Coefficient: ±0.18
Subjectabditg to damage from: Weathering: Negligible Termites: Veru Heavu
Width of Roof End Zone: 3'-4" Wind Speed: 165 mph ultimate
Wind Exposure Classification: C 1.21 x O.L = 0.12G
Adjustment factor for Exposure Height: ASO design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; 0.6DL+O.4WL
Components t Cladding Wind Pressure (NET) Roof Zone: I. +20.11 pat
Roof Zone: 2. +20.4/-51.0 pat
Roof Zone: 3. +20.4/-84.0 pat
Componerts t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4. +35.8/-38.1 pat
Wall Zone. 5. +35.8/-41.8 oaf
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3 pat
Shear Walla Considered for Structure? Yes
Continuous Load Path Provided? yes
Are Components an Cladding Details Provided? Yes
Minimum Soil Bearing Pressure:2.500 psi. Presumptive: X Bg Teat: psi
This Building Shall Have the Following:
APPROVED SHUTTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: 31 psf ROOF DEAD LOAD: 10 pat
FLOOR LIVE LOAD: --1-5- oaf FLOOR DEAD LOAD: 10 pat
JOB ADDRESS:
- rc2d5
= Roof Zone I
Walla Zone 4
EM = Roof Zone 2
Walls Zone 5
END ZONE
Corner Zones
Roof Zone 3
Braden it Braden AIA, PA
Architects - Planners
411 S.E. Coconut avenue
Tel : (112) 28-1-8258
Fax : (-172) 281-8283
E-mail. bradenaiaecomcast. net
08 Atiiart_ FL 3.499G UAACC00032
Wynne Building Corp.
T h e C� r a n d Carlton
MODEL:
GARAGE
RIGHT
Da5e9-11 wn ;
Drawn by:
C.C.U.
Checked by:
D.R.B.
Revisions
Sheet
1
I .
OF 5
Comm #
12 - 21
Spanish Lakes
St. Lucie County Florida
FLOOR FLAN <_� CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = V-O"
I. Contractor to verify ALL notes and dimensions prior to 36" high by 4" diameter
steel crash at. Floor
po
proceeding with work. Flange with 4 - 3/s°
2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansion bolts into
q slab (3/8"t 50 ksl steel plate)
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
L 2%," . 2
4.
S.
NO dissimilar metals to tout .
ALL Concrete used for slabs shall be min. 2,500 PSI concrete -
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
ALL
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
6.
Drywall at ceilings shall be leveled and attached to bottom chord
-I.
of trusses with screws per FBC R702.3.5.
ALL wood in contact with concrete shall be pressure treated.
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10.
Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11.
Contractor to Provide a T-8" wide door at one bathroom for
2yi- 2yi
handicap accessibility requirements. %_"
G„ �2
12.
Lowest finished floor to be set by Governing Building Department
13.
surveyor to set in field.
Separation between residence and garage shall be per FBC R302.6
14.
Door between garage and residence shall be 1-3/4"t 20 min. rated door
w.H. = Water Heater
15.
Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC
450 FBC
R302.9I
R36
I6.
Wall and ceiling finishes shall have a smoke -developed index of not greater than per
.9,2
1-1.
All exposed attic insulation materials installed on attic floors shall have a critical radiant
r' x 6" P.T.
Buck nail
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation
deck or on the attic walls shall comply
block with case
prior to door
harden
attachme
materials exposed on the underside of the roof
18.
with F.B.C. R316 - see permit info box of code edition
Gyypsum board material shall conform to ASTM C36, C19, C415, C514, CL30, C931
C40, C1002, C1041,C1111, C1118, C1218, C1395, or C1396 and shall be installed
according to the following: (FBC R102.3.5)
Drywall
Thickness
Location
Orientation
Framing
Member
Max. spacing
p g
of fasteners
Nall sizing options for
Installation of drywall Into
Spacing
Maximum
wood framing members
Nails
Screws
2" x min. thickness
Ceiling
Perpendicular
24"
1"
12"
13ga 13/8'011oong with 19/64" head
0.098" diameter x 1 1/4" long
annular -ringed or 5d cooler nail
R.
/2
0.080" dia0 x 15/8" long with
Walls
Either
I6"
8"
I6"
Direction
16/64" head
OR
Gypsum board nail 0.086' dig.
x 15/8" with 9/32" head.
Ceiling
Perpendicular
24"
1"
12"
13ga 1 5/8" long with 19/44" head
0,098" diameter x 1 3/8" long
annular -ringed or bd cooler nail
x�
a
Walls
Either
16"
8"
l6"
0.092" dia. 1 1/8" long with
1/4" head
Direction
OR
Gypsum board nail 0.0915" dia.
x I 1/8" with 19/64" head.
-*60 2 yi' a
0 0
to
Masonry Beam
/
Walla
Install SGD thru buck Into
block with 3/l6" tap -con with lJ 010
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20" o.c. max
thereafter at sill per product arc
19. ALL ceramic the surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and installed I.A.W. manufacturers recommendations shall
be used as backer for the Wall tile in tub areas and wall panels in shower areas.
21. Insulation Includiapor permeable members installed
ng facings such as retarders or v
within floor-celling assemblies, roof -ceiling assemblies, wall, crawl spaces and attics
shall have a flame spread Index not to exceed 25 with an accompanying smoke
developed index not to exceed 450 when tested in accordance with 4STM E 84
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6' end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank malls
e aced 6 o.c. at all laps and two eta rows 12" o.c. in field. Attach
dpeck to trusses using attachment detail er this sheet
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) lod x 1 1/2" nails
12
ENGINEERED TRUSSES
<�F!_E_lt
24" o.c.) supporting Max.F
240o.c. TYPICAL
drawings by
lelolbs. uplift
(shop manufacturer)
R-30 blown fiberglass
Aluminum Drip �
Edge k Fascia
in bottom chord of trusses
I/2" drywall with smooth finish
2" x 6" Sub -Fascia
Two rows of beam block filled with concrete
and (U tt5 bar Cont. In each row. Substitute
precast lintel filled with concrete and (1)#5
Ka ycan full o vent vimgl soffit installed
bar cont, for bottom row over openings
ua dia shank x I S" long gale.
roofing nails with 3/8" dia. head per
product approval - see chart sheet #1
1/2" dryywall over I" x furring
R4.1 f-fod
strips aE I6" o,c. with
insulation on typical
8" Block walls
=i
All drywall to
be installed per FBC R102.3.1
5/8" thick light textured
is
and shall meet all pertaining ASTM codes.
stucco typical concrete
w
Mortar to be Type M" onig proportioned per FBC R601.1
block construction
and Mortar Jonts shall comply with FBC R601.2.1.
Provide Our-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar vert. w/
FIII cell with concrete and
30" overlap
(
at each filled cell
not ex
M. spacing shall not exceed
Max.bar g shall
48" unless otherwise noted
Wood
see foundation plan notes for
Base
spacing at openings
4" concrete slab with fibermesh OR
611x4" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Grade r
,.. .
IIII-III
III
If
ee
IIIIIIIII
it-IIII=
=
III
IIII-IIII
�� III _ �'''-
-Iill ii 14" x 14,,Concrete footing
He with (2) #5 bprs cont. and #5
T Y fi i C A L SEC. I O N transverse bars at 48" o.c.
Scale : 1/2" = I'-O"
N.T.S
I I J
fixed door
sliding door
1/2"
Bottom Track �I
Sill
Elliding Door Detail
At Masonry Wall NTS
AREA CALCULATIONS
Living A/C = 1446
Front Porch = 141
Rear Porch = 200
Garage = 321
sq.
sq.
sq.
sq.
ft.
ft.
ft.
ft.
Total Under
Roof= 2108
sq.
ft.
Total Cubic
Ft = 11,568
2" VTR
JIL
I
I
I
I
21' VTR
JIL
Mastery/�
Bath
i 2•hrl
2" l.f
Lev.
4' 2" VTR
31
c.
JIL
3� I
i I
2' 3" %
Sher.
Kit. Sink I
I
Kitchen 2 I
I
Lay.
3"
w.c.
Bath #2 Sher.
3°
C.O. Ta Septic
RLUMBiNG RISER
1" x 6" P.T. Buck nailed to
block with case hardened nails
prior to door attachment ,
Masonry Wall
ypical Flooring
Install SGD thru buck into
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval) a m b
Window
Schedule
lark
Size
Rough Coen.
Window Description
PRESSURE ZONE
I.
4'-5%"x 5'
3 %a"
54%a"x 63i;"
Single Hung
ZONE 4
2,
6'-2%"x 5'
3 %'
15" x 63 i;'
Single Hung
ZONE 4
3.
2'-2" x 3'
2 I/2"
2l1/2"x 38%a"
Single Hung
ZONE 4
4'T2%a"
54%a"x 54Ya"
Single Hung
ZONE 4
ALL Window
and mullions
ALL windows
ALL windows
All rough opening
with manufacturer
lii to be aluminum windows W/ tint
per elevations.
to withstand pressures in permit info box on sheet l
in bathrooms to be tempered
dimensions to be verified bg contractor
s specs prior to construction
Door
Schedule
lark
Size
Rough O enin
Door Description
PRESSURE ZONE
A
9'-0" X T-O"
108" x 84"
Overhead Garage Door
ZONE 4
B
3'-0" X
'-8"
41 %i"x 83%'
Fiberglass Panel - Inswing
ZONE 4
C
6'-0" X 6
-8"
74" x 81 %' Of : ;;LeA
Sliding Glass Door
ZONE 4
D
2'-0" X
'-8"
Solid Core -
Wood - 6-Panel -Bi-Fold Finished 24" x 81'/2'
E
2'-6" X 6
-8"
Solid Core -
Wood - 6-Panel
F
5'-0" X
'-8"
Solid Core -
Wood - 6-Panel - Bi-Fold
G
2'-8" x 6'
8" x 1 %4"
Solid Core Wood, Steel, or Masonite Door
H
2'-8" X 6
-8"
Solid Core -
Wood - 6-Panel
1
2'-6" X 6
-8"
Solid Core -
Wood - 6-Panel - Bi-Fold
K
2'-8" X 6
-8"
Solid Core -
Wood - 6-Panel - Bi-Fold
a
34'-O"
00 00 00 00
-
EGRESS
12" x 12" concrete column block filled
E
with concrete and (2) #1 bars vert. tied
O
Into lintels above
o
�
Covered Porch
i
IT-8"
O
❑° N
00 CDI I I I I El I El Ell O
E I © MASTER
E
_
I BEDROOM
q
8'-O" to 9'-8" A.F.F.
u� M
in
Vaulted edtng `� 8'-O" A.F.F.
n� v'
Flat Ceding
GAR AT
�
N
RgOM
®
I
O I
N
Rod Shelf
E
°
Vanity to e
I
I 34 Y2"high
N
I w i 6
H.B.
L S E T 1 0
O
8'-0" to T-8" A.F. 2" x 6" knee -wall
below top W_ O M
Vaulted Ceiling I counter I rr, rU
DiNING I I
_ __
ROOM L LINEN
I a,� 8„ Rod Shelf A81NET
E O
W
(111 if
I SAT
O
O
Vanity to be i �� °
E
W
34 %2 ,high I I
O
Nc
High Wall I
E
KII T C H E N m
iv I-I/2"- J
Vent
throug
ryer
wall
_ - i
- - �ver�iang 8'-0" A.F.F.
N t
0 Flat Ceding - u
0
H.E
`0
Upper cabinets to
extend over Ref.
II
v
u 1 I
" Filler N
ffccTTppuu yy�� _ .�
ATH _ _ 31C
4'-O"
Nad-viatsnm-
O O Rod it Shelf
e -II Batts Wei
_
4"cli Steel Ballard
I
aefi- Q$tgd. $n this sheet
Ln
F j F 22" x 5-4-
O Attic Access Provide auto
N
wth light l closer
Q Q
E
8'-0" A.F.F. OL 22"
UU�
Flat ceiling Ln 4„ 150 Amp
o
6'-O" g
Panel
Meter
FLLN
a
m
1O\ SECOND
0
BEDROOM E ERGEN Y
GARAGE
N GRESS
_
EEI IMT EE 8' 4" A.F.F.01L O
E
m
E Flat Ceiling
CIA
o
EGRESS r-----------------i
O
E Block wall in
OE ao E E O" _ I garage to be I
v
struck block
O O I I
O
COV E R D
O
12" x 12" concre a column block filled I i
ith concrete and (2) #1 bars vert. tied ORC
n
into II tels above I
s
6" 4' 2" I
I ® I I
Z1
E
E
N
0
° ` 00 091
4'-2"
2, 8"
2'-8"
5'-4"
Install windows thru buck into
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at lambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall -\ / \ Buck to be I" x 4" PT
ALL Exterior doors to Withstand pressures stated in permit info Al Varies
box on sheet UI
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
All rough o eninc dimensions to be verified by contractor Detail at wlndowS
With manufa turer s specs prior to construction
Braden t Braden AIIA, FA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (112) 281-8283
E-mail: bradenaia6comcast.net
Stuart. FL 34994 #AACOO0032
1"x4" P.T. Buck nailed to INSTALL VULKEM BLOCK SEALANT
block with case hardened nails ON ALL JAMB, HEADER, AND
prior to window attachment SILL BLOCK PRIOR TO BUCK
INSTALLATION
NTS
gnne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
Oil
Attach buck to block wall with
1/4" dia. Elco conc screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max From each corner thru
Exterior face 2" x 6" PT Buck
of wall
' aries
#8 Wood screws thru Jamb into buck
at each hinge and 15" o.c. max and
Detail at Door prior to door attachment
MODEL: Date Drawn : Revisions
5-9-I1
GARAGE Drawn by;
RIGHT C.C.U.
Checked by:
D.R.B.
Sheet
2.
OF 5
NTS
Comm #
12-21
39'-U
2
W3
4
TRUCTURAL MOTES:
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
9,
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSI AT 28 DAYS
IC
CELLS, AND SEAMBE MIN. 3000 PSI
MPSI L4,000 AT
PSI GROUTED
BEL3000 OR MIX 28LDAYS
POISON SOIL AND COVER W/ 4 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
Ii
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
13
MACHINE COMPACTED TO A MINIMUM OP 2500 PSI IN AREA OF
BUILDING CONSTRUCTION
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
15
ATTENTION OF THE ARCHITECT.
16
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
IZ
FOuAD/471ON FL/4N
SLOPE ALL FOR H SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WIND VELOCIT = PER PERMIT INFO BOX ON SHEET #I
EXPOSURE ="C"
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-I6, 8
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 307 STEEL.
ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2",
LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
USE STRUCTURAL, GRADE WOOD WITH A MINIMUM Fb OF 1600 FBI
ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
ALL LUMBER IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
1. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification Of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
�{. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and I #5 bar vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings Upp to 5'—Il" wide.
Provide (2) filled cells on each side of openings from (o'—O" to 9'—II"
and Provide (3) filled cells on each side of openings from IO'—O" and up
Contractor to see plans for any other condition used. Foundation walls
shall have filled cells at 24" O,c. unless otherwise noted (see section)
6. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A—I6 and
A- 35 specifications. ALL Anchors to be A-307 Steel,
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
Le
45 bar vert. w/ Thicken edge to 8"x8"
30" overlap SEE TYPICAL with concrete and
at each filled cell ECTIONS one 95 bar continuous
4" concrete slab with fibermesh OR GRADE
6"xb" #10/I0 WWM on Io mil Visqueen over
clean compacted termite treated fill
ctl
11 4111�1'1 III I I 14"w x 14"d concrete monolithic
_„ OF
footing with 12) =5 bars cont.
14„
TYPICAL FOOTING DETAIL
4" concrete slab with fibermesh OR
6 x6 #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
45 bar cont.
Step per
foundation plan
v O.
(2) #5 bars cont, bottom steel
12"
DETAIL AT GARAGE STEPDOUIN
SCALE 1/2"
12" x 12" concrete column
block filled with concrete
and (2) tt'1 bars vert. tied
into lintels above
Top of Tooter
14" below finished flc
"
LT
Verify house slab
height in field
30"x30"xl6" concrete
column rooting with (4)
#5 bars each way
1=i 30" r1
COLUMN FOOTING DETAIL
LE 1/2" '-U
SCALE: 1/4" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
4" concret,e slab with fibermesh OR
(."xi;" 410/10 WWM on 10 mil Visqueen over
clean comekicted termite treated fill
PORCH SLAB EDGE
B
45 bar vert. w/
30" overlap
at each filled cell
Adjust curb height
based on gar. floor
slope.
#5 bar in curb \
\SEE TYP
AECTION
4" con
6"xb" 410,
clean c
i:s
ETAIL
tLE 1/2" = 1'-0"
slab with fibermesh OR
wM on 10 mil Visqueen over
Led termite treated fill
x 14"d concrete monolithic
is with (2) 45 bars cont.
r=ARAnE CURB DETAIL
c
4.
2" x 6" PT wood secured with \
3/8"ilia. x 6" anchor bolt at 18" ci,c.overhead
jamb per
��
track secured to wood
acturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED
IN PERMIT INFO BOX ON SHEET #I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER, MAKE AND MODEL.
NTS
a
V
Filled Cell Masonry Column With One
#5 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Sinale Filled Cell Column
NTS
Filled Cell Masonry Column With One
95 From Footing To Beam Each,
Conc. Fill To Be 3000 FBI
See Floor Plan For Location
Double Filled Cell Column
NTS
20'-0" 4'-0.
00 OOi�il :1:i 00 00
L
° -I ------- I-------- �r---=-------
O
I
Filled cell under -
girder above O i FI I
E
I = Rear Patio/Slab
I� Ul 2—to be poured separate -7 L , I
house
a- from the slab.
I o IN IE
cn r
Thicken footing to I
I
I 24"w x 14"d x 24"L
a E I under filled cell FI I
�� E ° E O0 under girder bearing.
— — — — — — J
4, 1�
Rear Patio/Slab to I
—
° I he flush with bottom of
sliding door recess. I
1 Slope 1/2"
Qv ra
OO
v-
I
Na_
_a I
E
EI I
Fi
°
0
I
H.B.
4" concrete slab with fibermesh OR
6"xb" UIO/10 WWM on 6 mil Visqueen over
I clean compacted termite treated fill
Fi 1
0
�7
_
I
I
° �
°
FI
I
2) t
�I
4' O"
of f
A/C
#I
__ -- — — ——
;1- —lE
4"0 Steel Ballard I
o
W ®filled w/ Concrete
>1II F
EI Q1,0, I°o to
w I
a.v
I I I Wm E I
FI- I E G
r—
/ a v O
IS
I F I / I _ 00 `u N
oL--_—_ _—_—_ _—_—�� 105 �o� I
OD O TTTT
U_ 8I
8
a I O 14'_C a
r
� I
I—i F4 r 8-4E t — — — — Recess for � — _ E
°--------- EO Garage Door 00 00
° EE
L
3 F
1,12" x 12" concrete column block filled
with concrete and (2) 41 bars vert. tied
into lintels above
FILE C
FOOTING
SCHEDULE
Description
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
Isize
12"W
X 12"D
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
30"
x 3o" x 16"D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
8"W
x 8"D
THICKEN SLAB EDGE
WITH 1 45 BAR CONTINUOUS
F5
14"W
With
x 14"D
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB s O'-O"
Braden Braden ,41�4,
ulgnne Building Corp.
MODEL:
Date Drawn :
Revisions :
Sheet
Comm #
Architects — Planners
411 S.E. Coconut Avenue
T� e G r o n d C d r l t on
GARAGE
RIGHT
5-9-1�
Drawn by:
12 — 2 �I
0Tel : (112) 281-8258
C.Q.U.
Fax : (112) 28�-8283
Spanish Lakes
Checked by:
E-mail: bradenaia5comcast.net
Stuart. FL 34996 #AAC000032
St. Lucie County Florida
D.R.B.
OF 5
a
Q.A.•
ring shank
e
.8d
Concrete
/ Lintel
Column
Verlfy wlth Plarii
12"x 12"
Column Block
Provide 3:5 bars with min. 48 bar
diameters overlap into beam. Tie
Filled cell steel into continuous
beam block steel
Provide Cast -Crete
8118-OB/OT precast
lintel set in mortar
Min. 8" Bearing
4"
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calls for it.
e PT I Buck
wd pert jamb
Into filled c
Filled Cell
Provide #5 bars with min. 48 bar
diameters overlap in filled cell. Tie
filled cell steel into continuous
Tooter steel.
t I I!s
+ I I Concrete Footing
- J..` T---li• + }-�- (see footer schedule
for exact sizes)
DETAIL AT WIN60W OPENING IN
Scale: 1/2" = 1'-0"
CBS WALL
v
n
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to vert. leg of
truss with IOd x 1.5' nails at 4" o.c.
Install Simpson MGT into wall using
�5/8" dia. threaded rod set min. 12"
into wet beam and (22) IOd nails into truss
v#1 Rebar
Reber 48 Bar Dial.
Mln. ,Overlap TRU iS BLOCKING DETAIL
t0 1-Intl Attachment AT GIRDER STRAPPING
AT CENTER BEARING POINT
NTS
1/8' thick light textured stucco installed per
ASTM C 924 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D T4pe 2 felt paper using ad nails. Substrate\
to be 19/32, CDX Plywood nailed at 6" o.c. in field ?�
and edges with IOd ring shank nails into studs.
Gulf Coast Supply and MFG Sv Crimp Metal roofing FL #116E
26 ga. Sv crimp metal roofing attached to plywood deck using
wood screws with self sealing washer at 12" o.c. max spacing o'
(type 2) 30 lb felt underlayment installed with min. 4' side la
laps fastened with corrosion resistant tin caps and with 1.25" 1
spaced 6 o.c. at all laps and two staggered rows 12" o.c. in
deck to trusses using attachment detail on this sheet
Additional Precast Lintel
Lintel
Bar
Clear
"A"
tt5 bare
CLEAR
Length
Length
Span
Bars
Bars
i
2'-8"
-6"
2.43
none
2'-10"
2'-2"
2,93
none
`----' `----'i �----
8F8-OBAT BF8-IB/IT BF8-IB/2T
4'-0"
3'-10"
2'-8"
2,93
none
Additional
4'-6"
3, -2"
2,43
none
_ #5 bars `•
�.+. �:'1!":`
CLEAR
- ne Row of "H"',;
7r Block Above .�
5'-4"
5'-2"
4'-O"
2,43
none
5'-10"
5'-8"
4'-6"
2,#4
none
Precast Lintel in
':`•:'';
-4"
S'-4"
2.44
none
I I Additional
i #5 bars '
'L----" '`----''"
6'-2"
2.#5
none
BFIL-IBAT BFIL-8/2"r
"
1'-10"
T-O"
2,45
none
NOTES:
I. min. coverage of steel=1.5"
2. min. bearing required a ea. end=8"
ALL reinforcing steel is grade 60.
3. standard for remf. steel=ASTM A615
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL
SCHEDULE
Window
Kowa of
" " k
Max
Gravely
Max
Uplift
Max
Lateral
Mark
oUniit�
Lintel
Cast -Crete
Above
Bottom
slze
".P.,sae
Load(PLF
Load
Load
Width
Size
Specification
" a
steel
L22
2'-2"
3'-V
SF8-OBAT
1
85
1 3044
1369
1024
L31
2'-L"
4'-O"
8F8-OBAT
I
s5
25L1
1513
1L3
2'-8"
L45
4'-5"
5'-10"
8F8-OB/IT
I
are
IIOS
909
334
L50
5-0"
L'-v
BF8-OBAT
1
85
1238
835
121
LLO
4'-8.
1'-L'
BF8-OB/IT
I
#5
1011
121
534
LBO
B'-On
T-4"
BF8-I15/2T
I
#5
2
s5
152
Sail
512
L90
9'-0"
10'-4"
BF8-I5/2T
I
#5
2
s5
L43
530
401
L90B
T-O"
10'-L"
8FIL-I13/2T
ONE
1
#5
2
a5
1533
1183
401
LI00
10'-0"
II'-4"
BF8-IB/2T
1
#5
2
#5
582
494
452
LIOOB
10'-O"
ll'-"S'
812I4-6/2T
ONE
1
#5
2
#5
13LL
1028
452
LI20
IT -On
13'-4"
BF8-I15/2T
1
#5
2
s5
411
428
324
L120B
12'-0'
13'-4"
8FIL-I15/2T
ONE
1
tt5
2
a5
1015
110
324
LI40 14'-0"
15'-4"
8FIL-8/2T ONE
1 tt5 2
s5
1250
609
254
LILO IL'-O"
IT-4"
are-IB/2T
I #5 2
85
300
192
194
1_I1.015 IL'-O"
11'-4"
BFI6-IB/2T ONE
I #sT 2
1 85
1 950
Boo
194
- ALL LINTELS SHALL
BE MADE BY
CAST-CRETE•
- LINTELS
SHALL
BE FILLED SOLID WITH
3000 PSI
CONCRETE
- REFER TO CAST-CRETE
CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION,
AND
SAFE LOAD REQ.
REQUIREMENTS
- LINTELS
OVER
14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor et each truss
with (10) IOd x 11/2' nails -
( 24" o.c.) supporting Max.
1810ibs. uplift
Aluminum Drip _
Edge ! Fascia
2" x 6" Sub-F
Aluminum Drip
12 Edge t Fascia
#9 x 1.5"
er ASTM D
s and 6" end
ng shank nails Flash and Counter
field. Attach flash
Nail ledger to
gable end truss
with (2) IOd Is
at each web
12
4
1/2' think stucco on 3/8" hi -rib lath
attached to horizontal and vertical wood
12° framing with nails or staples to provide
no less than 1-3/4" penetration into
horizontal wood framing and 3/4" penetration
into vertical wood framing members
Kagcan full o vent vinyl soffit installed
using 1/8' die shank x 15" long gals.
roofing nails with 3/8" diat head per
product approval - see chart sheet #1
12' x 12' concrete column
block filled with concrete
and (2) #1 bars vert. tie
into lintels above
thicken edge to Vx8"
with concrete and \
one #5 bar continuous
BEYOND
Top of footer
16" below finished floor
a
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#S bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Step per foundation plan
Slope per foundation plan 'r
O
N
W
Co erete Anchors Per
Ma ufacturera Spec.
Poured Concrete or
concrete block wall I/4"Max.
Aluminum Panel
I Saes per manufacturer
I•
d'
See Tuncel Stud Detall
' 1/8" x 3/32" Wing Nut w/
appropriate washer and spacing
I> per manufacturer's Details
LL g Oc3'
h"m glee i c c
I
J i
AM
I a
i m � m
I
I �
I —
I
I
I
I I IBlS'
I
I
Stud Detail
Poured Concrete or nTa
concrete block well Stud w/ Die Cast Zinc
Nickel Plated Wing Nut
i.i•
Concrete Anchors Per �.
Manufacturers Spec.
Flush Mounted Shutter Detail
nt5
W ood
Base
Brace Gable end
with 2" x 4" SYP tt2
8ft back nailed to bottom
of top chords using (2) IOd
nails at each truss
PRE-ENGINEERED WOOD TRUSSES
® 24"o.c. TYPICAL
( shop drawings by manufacturer )
f
f
R-30 blown fiberglass
in bottom chord of trusses
-1/2" drywall with smooth finish
Two rows of beam block filled with concrete
.and (1) #S bar cons. in each row. Substitute
precast lintel filled with concrete and (1) #5
bar cont. for bottom row over openings
1/2" drgwall over 1" x furringg
strips at IL" o.c. with R4.1 fi-foil
-insulation on t pical 8" Block walls
Simpson HETA 20
hurricane anchor at each truss
( 24" o.c.) supporting Max.
1810 lbs. uplift
Strap truss to wall using Simpson MGT with
5/8" dia. threaded rod with min 12" embedment
into beam either wet set or in epoxy with
(22) IOd nails into truss. Add blocking to
( -!`ETA 1 truss leg per detail on this sheet
S
CA
..
.; :'
.:
,..':
L90
L90
LLO
BI
�r
BI
BI
O
ro
ls'r L90 BI
i
�
E31
LLD�/Z
�
I W
~
1
12
_ZZ
�
XI
:�tl //x W
LZ��/Z I
a3 ZZ
II rn�
VJ —?
2"
[L=3
I -LJ I
//
I,
W
S OPE N
I
U
W ��
W otn
I 1 N3
z
I
N
Q
i
YL
W
I
O
Qi
`,
H
f
BI L31
L
='
1;.
N
--
Pik,
-- -- — ' --
V
—
cy N
Gulf Coast Suppig and MFG Sy
Crimp Metal roofing FL 3*1101.12
<
woo screws with self sealing w
sher at 12" o.c. max spacing over ASTM D
-
Itype 2) 30 lb felt underlaym
t installed with min. 4' side laps and 6" end
laps fastened with corrosion re
istant tin caps and with 1.25" ring shank nails
eck to trusses using ttachme
t detai on this sheet
/C
BI
#I
I
r- ---
O
Attic Access
I
Q
with fight SLOPE
BI 1 I U ubbe
I I T( Idof
1
ted
T
I
8'-0' MAX.
I
with 2" x
8ft back
I ( T 5
5
of top the
I
T1
1
I
n
I
Z I
2"
I L
I
I
p I
I
BI I BI 1
1
I
BI L45
=
V
1
Q
...
BI
N
rn
W
50 on
hurrlca Lint
ET
r at
2
each
trus
N
BI
( c.)
uppo
ting'lax.
It"1810
bs. u
lift
BI
BI
pLTO10
BI
LLO
L90B
snVol;
FlILLLL
a 'it-
JC4
Brace Gable enc
4" SYP 42 min
nailed to bottort
rds using (2) IOc
ails at each truss
1
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes. ETA 2O
ao Mortar to be Type "M" on proportioned per FBC R601.1
and Mortar shall comply with FBC R401.2-1.
FILE C )�
Provide Our
-O--O-Rock at all wet areas (ex. shower
s, tubs etc...)
Fill cell with concrete and ROOF P L" 4 I �l (U 45 Max. sppbar vert. (typicaU.
sh
48" unless notherwi eonoted exceeel
see foundation plan notes for - OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET
spacing at openings - ROOF PITCH AT -4:12 UNLESS OTHERWISE NOTED ON THIS SHEET
4" concrete Blab with fibesh - TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
mil Vlsqueen over
6"x6" #10/10 WWM on 6 mil en
clean compacted termite treated fill - ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
STARTIN CONSTRUCTION
f
111i- I�II_lill 3 7�plcal Section at Front Forch
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO G
- ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
- ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
- CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
1=nlPM RnbPn �;11PV�Y TO TRUSS r—OMP,ANY PRIOR TO TRUSS CONSTRUCTION
Braden It Braden AIA, PA
Wynne Building Corp.
MODEL:
Date Drawn:
Revisions :
Sheet
Comm
Architects - Planners
411 S.E. Coconut Avenue
The Grand Carlton
GARAGE RIGHT
5-9-11
Drawn by:
12-21
Tel (712) 281-8258
C.C.U-
.
Fax : (172) 287-8283
Spanish Lakes
Checked bg:
E-mail: bradenaia comcast.net
Stuart- FL 3499G #AAC000032
St. Lucie County Florida
D.R.B.
OF 5
PANEL
"A"
Poles
BR
Load
wire
Description
circ#
curt#
Description
Wire
Load
BR
Poles
2
40
1.0 kw
#8
A/C comp
1
2
AHLI
#lo
3.5 kw
30
2
3
5
4
4
Range
2
30
4.5 kw
#10
40 gal. water HTR
U.12.0
kw
50
2
9
e
10
2
1
20
1.8 kw
#12
Pump
Dr er
410
5.0 kw
30
II
13
12
14
Dishwasher
1
20
1.5 kw
#12
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Microwave
Is
IL
Refrigerator
#12
1.2 kw
20
1
1
20
1.5 kw
#12
Kitchen S.A.C.
I,
I8
Recepts
#12
20
1
I
20
1.5 kw
tt12
Kitchen S.A.C.
19
20
Recepts
#12
20
1
1
20
1 1.2 kw
#12
Clothes Washer
21
22
Recepts
Recepts
#12
20
1
1
20
0.81 kw
#12
Garage Door Opener
23
24
912
20
1
1
20
1.4 kw
#12
25
24
Recepts
#12
20
1
1
20
1.92 kw
#12
27
28
Recepts
#12
20
1
1
20
#12
General Lighting
29
30
Recepts
#12
20
1
1
20
#12
1 General Lighting
31
32
Recepts
#12
20
1
1
20
#12
General Lighting
33
34
Exterior GFCI
#12
-
20
1
1
20
#12
General Lighting
35
3t.
Bathroom GPI
S12
20
1
1
20
#12
Smoke Detectors
3-1
38
General Lighting
#12
20
1
I
20
#12
Bathroom GPI
39
40
General Lighting
#12
20
1
spare
41
42
spare
PANEL "A" LOAD CALCULATION SHEET
Load Description Ot - Watts Total(Watts)
General Lighting .(3. ,watts, sq.. ft.). .. . ... . 11 ..... . .....
Small Appliance. Clrcutt(s)..... ........ , , . .. ..........
Range ....... .................. .................. ..........
Refrigerator..................................................
Microwave
.................................................................
Dish Washer
. Clothes.,Washer...............................................1
Clothes Dryer ................................................
Water Heater
Water. _Pump ..................................................
.Garage Door , Opener
1135
3
5,205
2
1,500
3,000
1
12,000
12,000
1
1.200
1,200
1
1,500
1.500
.
1
1,200
1,200
1.200
1.200
1
5,000
6,000
1
I
4,500
4.500
1.800
1,800
1
810
810
Total Watts
31.415
First 10000 Watts 0100%
1
10,000
10.000
Remainder 21,415 0140%
1
O
10,944
Electric Heat or A/C 10,000 e65%
1
10.000
10,000
Calculated Load
Watts
30.946
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 129.03
Panel Size Required = 150 Amps
Electrical Simbol Legend
$
Single Pole Switch
lRecessed
Can Light
$3
Double Pole Switch
®
Eyeball Recessed
Exhaust Fan
Ceiling Mounted Light
Wall Mounted Light
Pe
Push Button Switch
�AA
Duplex Outlet
Y
Special Receptacle
0-
Waterproof ground fault circuit
PC
Light with Pull Chain (attic)
®r
Floor Duplex Outlet
©
Computer Connection Jack
Flood Light
FE-m-1
Carbon Monoxide Detector
(D
Thermostat
m
Electrical Panel
Electrical Meter
Ceiling fan
©
Central Vac
IEE�
®
Smoke Detector
X1
©
Television Jack
FTFI
Telephone Jack
A DSC
I A/C Oisconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
PKR
Speaker Hook -Up
Intercom J
®= JUNCTION BOX TO SUPPORT A PAN
O = THERMOSTAT LOCATION
B/A = BALANCED AIR
Electric Notes:
I. Use copper wire onlg, no aluminum.
2. Provide and wire all required smoke detectors.
3. Contractor to verify location of electrical
service and provider.
4. ALL paddle fans shall be on a rheostat.
5. ALL bath and kitchen receptacles to be GFI protected.
6. ALL exterior outlets to be WP/GFI protected.
1. Recessed cans to be installed per NFPA requirements.
8. AFCI receptacles are required in all rooms except
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RM1402
10. A/C Refrigerant lines that are run thru slabs must be
sleeved in AVC
11. ALL A/C Equipment shall comply with energy calculation
12. All work shall be performed bg a licensed electrical
contractor, the completed system shall be full operative.
13. Contractor shall pay for all fees, permits, testin and
inspections including blower testing where required.
14. All work shall be coordinated with other trades to avoid
interference with the progress of construction.
15. All required insurance shall be provided for protection
against the public liability and property damage for the
duration of the work.
16- Contractor shall guarantee all materials and workmanship
free of defects for a period of not less than two years from
the date of acceptance or certificate of occupancy, or one
year from closing sale of house.
Correction of defects shall be completed without additional
charge and shall include replacements or repair of any
other phase of installation that may have been damaged.
PATIO/SLAB
I
GREAT
RGOM
I
I
I
Center Registers
149 CFM on ceding fan 19 CFM
xOIOxlOxl �
163 CFM
IOxI0x6
MASTER
BEDROOM
163 CFM
IOxlox6
I I - - - - - - - - - - - a
12x12x9
B/A
LOSET H.B.
8 CF
8x4x4 a
I 1
I 1
1 12" L 8x4x4
1 ,' - 34 M
DINING I �i _ _ ____Vent_thru
ROOM I ~ / \ I BAT Soffit
I �� o
o I
io^
°fe K
153 CFM
o � 12x12x1 It
Vent _thru_-- _ _ -� 'le x4 fib A ' 1 i� 8x4x4
Soffit A-� lei I O I
20x20 F 00 - - -
I T
I
A/C
14" 1 w 1 l" 22" x s4"- #I
Attic Access
232 CFM 1 $ °i4h light
12xbxl I Q QI L-----�
LJ6_ �^�-J'
J 150 Amp
Panel Meter
SECOND
BEDROOM 3xx GARAGE
1
12x12x8 j
B/A
COVERED
PORCH
MECH4NfC4L L,4YOU7
SCALE. I/4" = I'-O"
11. It is not the intent of these plans to show every minor detail
of construction. The contractor shall furnish and install
all items for a complete electrical system and provide all
the requirements necessary for the equipment to be placed in
proper working order.
18. All work shall be done in accordance with the N.E.C. and
shall comply with all local codes and ordinances, and shall
meet all standard requirements of the local electric utility
and telephone company.
19. The electrical system shall be complete g and effectively
grounded as required bg the latest edition of the N.E.C.
20. All material shall be new and shall bear underwriters'
labels where applicable.
21. All equipment and panel sizes shall be yerified before
ordering. The contractor shall provide circuit routings to
suit the Job conditions.
22. Furnish and install all fixtures as called for on the plans
or as selected bg others.
23. All raceways and pipes placed in or tfirough any concrete
slab shall be spaced a minimum of three diameters of the
largest conduit or pipe from any other service.
24. All exposed wire below 9'-1" shall be installed in metal EMT
conduit.
25. Dryer Vents to be installed per FBq RM1502
r----------------- 1
I
I I
I I
I I
I I
I 1
I I
I I
I
I I
I I
I I
#2/0 Aluminum feed
1 '/2' Conduit -.
2" PVC (
2" rigid service FPL
ELECTiRICA
A/C disc.
ISO
MCB
PANEL
are #6 copper wire
i #5 cont. rebar in slab
L RISER
- Contractor shall use AL-CU Landing lugs. NITS
- Contractor shall torque lugs I.A.W.
manufacturers recommend atlons which
shall be verified prior to construction
Braden It Braden AIIA, PA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (112) 287-8283
E-mail: bradenaia°comcast.net
Stuart. FL 34994 UAAC000032
H.B.
Exhaust Duct
Thru Soffit -
Wire For
+
Front Post
Light
PATIO/SLAB
ELEC7RIC,4L PL,4N
6' - 3"
G
Post Light with
I Photo call
Wynne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
Install oulet
under disc.
t shown for
clarity
FILE CG,�-
SCALE: 114" = 1'-0"
Attic Vertirg Calculations FBC 2309.7
Total Attic Space = 2124 sq. ft.
Venting Ratio 1/150 = 14.16 sq. ft. required
MODEL:
GARAGE
RIGHT
Provide A Continuous Vented Soffit
)ate Drawn Revisions
5-9-11
Drawn by:
C.C.U.
Checked by:
D.R.B.
Sheet Comm 9
E-1 112-21
OF 5