Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE+4 . FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: THE GRAND CARLTON SCE NNF_D Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT BY Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL ,^ A Permit Number: St Lucie Coulii / Owner: Q i vc Jurisdiction: Design Location: FL, ST_LUCIE_CO_INTL County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1437.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Exterior R=11.0 187.33 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1446.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade (ft2) 1446 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(139.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 320 a. U-Factor: Dbl, U=0.54 99.23 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.586 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1446.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1446.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 46.91 PASS Total Baseline Loads: 48.19 I hereby certify that the plans and specifications covered by Review of the plans and 04E S qTB this calculation are in compliance with the Florida Energy specifications covered by this 04 Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'Orj WME OWNER/A P5- BUILDING OFFICIAL: DATE: N DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. FILE CG,��` 12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: ^ THE GRAND CARLTON Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Own; r: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEVELOPME Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 234 1872 No 2 1 1 Yes Yes Yes 2 WIC 54 432 No 0 1 No Yes Yes 3 MASTER BATH 63 504 No 0 1 Yes Yes Yes 4 M.BATH 56 448 No 0 1 Yes Yes Yes 5 KITCHEN 172 1376 Yes 0 1 No Yes Yes 6 BATH 45 360 No 0 1 Yes Yes Yes 7 BEDROOM 2 204 1632 No 1 1 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 526 4208 No 0 1 Yes Yes Yes 10 FOYER 50 400 No 0 1 Yes Yes Yes FLOORS Floor Type Space' Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 40 ft 0 234 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 54 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 9 ft 0 63 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 __-- 0 1 0 6 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 --- 0 1 0 7 Slab -On -Grade Edge Insulatio BEDROOM 2 34.2 ft 0 204 ft2 ---- 0 1 0 12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8SIab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 47 ft 0 526 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio FOYER 7 ft 0 50 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1524 ft2 240 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 234 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 54 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 63 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 5 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 6 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 7 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 526 ft2 0.1 Wood 10 Under Attic (Vented) FOYER 30 Blown 50 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 1 N=>SE Exterior Concrete Block - Ext InsiflEDROOM 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 2 S=>NW Exterior Concrete Block - Ext Insi3EDROOM 4.1 18 0 8 0 144.0 ft2 0 0 0.5 0 3 W=>NE Exterior Concrete Block - Ext InsdBEDROOM 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 4 S=>NW Exterior Concrete Block - Ext InsMASTER BA 4.1 9 0 8 0 72.0 ft2 0 0 0.5 0 5 S=>NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 6 N=>SE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 7 N=>SE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 8 E=>SW Exterior Concrete Block - Ext InfiEDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.5 0 9 SE=>W Exterior Concrete Block - Ext InfiffDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.5 0 _ 10 S=>NW Exterior Concrete Block - Ext InJ3ffDR0OM 2 4.1 4 0 8 0 32.0 ft2 0 0 0.5 0 _ 11 S=>NW Exterior Concrete Block - Ext InsalAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 12 N=>SE Exterior Concrete Block - Ext InsGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.5 0 12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo Space le Et In Et In Area R-Vahle Erart*on Ahsor w rrade% 13 W=>NE Exterior Concrete Block - Ext InsGiREAT/DINI 4.1 21 0 8 0 168.0 ft2 0 0 0.5 0 14 N=>SE Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 15 E=>SW Exterior Concrete Block - Ext Insul FOYER 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 16 N=>SE Exterior Frame - Wood GREAT/DINT 11 23 5 8 187.3 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated FOYER None .28 3 6 8 20 ft2 / Wall V # Ornt ID Frame Panes NFRC U-Factor SHGC 1 W=>NE 3 Metal Low-E Double Yes 0.54 0.25 3 # Floor Area 1 315 ft2 I # Scope Method I 1 Wholehouse Proposed ACH(50) 2 2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6 3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 2 3 4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 3 6 5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 4 0 # Floor Area 1 315 ft2 I # Scope Method I 1 Wholehouse Proposed ACH(50) GARAGE tiling Area Exposed Wall Perimeter A 315 ft2 24 ft INFILTRATION SLA CFM 50 ELA EgLA .000356 1349.6 74.09 139.34 HEATING SYSTEM Overhang Area Depth Separation Int Shade Screening .4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 .9 ft2 1 ft 0 in 1 ft 4 in None None .2 ft2 1 ft 0 in 1 ft 4 in None None .8 ft2 1 ft 0 in 1 ft 4 in None None .0 ft2 10 ft 0 in 1 ft 4 in None None Wall 8ft ACH .2669 Wall Insulation 11 ACH 50 7 # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 12/10/2017 5:25 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 Wall 8ft ACH .2669 Wall Insulation 11 ACH 50 7 # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 12/10/2017 5:25 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / -- Supply — — Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 320 ft2 Attic 80 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heating HJan H Feb ki Mar Apr I May Jun riJul i May ri Aug ri Sep rl Oct Oct Nov H Nov Dec H Venting Jan Feb Mar Jun Jul Aug Sep Oct Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 1 � FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, ST LUCIE_CO_INTL COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I ,vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/10/2017 5:25 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ftZ 7. Windows- Description a. U-Factor: Dbl, U=0.54 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.55 SHGC: SHGC=0.25 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: WYNNE DEVELOPMENT, FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftZ b. Frame - Wood, Exterior R=11.0 187.33 ftZ 1 c. N/A R= ftz 2 d. N/A R= ftZ 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1446.00 ftZ 1446 b. N/A R= ftZ Area c. N/A R= ftZ 99:23 ftZ 11. Ducts R ftZ a. Sup: Attic, Ret: Attic, AH: Attic 6 320 40.00 ftZ 12. Cooling systems kBtu/hr Efficiency ftZ a. Central Unit 34.8 SEER:15.00 B. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ftZ 13. Heating systems a. Electric Heat Pump 3.586 ft. 0.250 Area 14. Hot water systems 1446.00 ftZ a. Electric ftZ b. Conservation features ftZ None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: , City/FL Zip:Sk kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.97 Pstat e-t1j4iE SrArFo Gj'�rr�yy��rr�''• a r` �' .��` UN' tiff �caD ��v5 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 - wrightsoft® Project Summary Date: Entire House By: QUICK CALLS, INC. 317 ST.-LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466.6799 Fax 772A66-6796. Email: QUIC.KCALCS(AOL.COM. For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Q Design Information Weather. Fort Pierce,' FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 24753. Btuh Infiltration sensible Method Simplified Latent Cooling -Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Heat' Cool' % (none) Area (ft2) 1446 14 Equipment latent load -5521 Btuh Volume (W) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A" 030 Cond 25HBC536A`030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling . 34800 Btuh Actual'air flow 1160 cfm Actual air flow 1160. cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0:50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input — 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. + wrightsoft` 2017-Apr-11 09:29:38 ACC Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N wrigntsof . Right-JO Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946-Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM Job: Date: By: 1 Room name Entire House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ftz 297.0 ftz Ty Construction number U-value (Btuh/ftk*F) Or HTM (Btuh/ft2) Area (ft-) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 ? 13A flocs ': ;.0.143 n ,, 4:00: 2.55 503 465 1862 -: 1184 . - 72 72 . 288: 183 4A5 tom •'•" , .0;770 , n' : 21,56. . 19 31 ; 38 0. 815 730. .'0 '0 13A-4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 1Ac1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 11 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A-0ocs 0.143 se 4.00 2.55 34 34 136 86 0 0 0 ` 0 VIJ 13AAocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550 1Ac1om 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 -a 13A-46cs 0:143 w 4:00 2.55 310 237 949 603 104 72 288 183 1"Ac1om 1.270 w 35t56 55.21 32 2 1140 1770 32 2 1140 1770. .. _ 0}770 w 21.56 •19.31 41 . 41 '. 880 ::. 788 0 - .0 .. 0: .. 0 P ,4A5r2om 12C-0sw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C .. 16Q-30md 0.032 -. 0 90' ,.. : 2.3.2 1446' 1446 -. 1296 :: 3354 297' :,.., 297 ` .:... 266 F 22A tpl 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED e)xursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 1-1520 5053 4925 15 Ductloads 32%1 490/o 5654 8536 32% 49% 1601 2400 Total room load 23503 26056 6653 7325 Air required (cfm) 1160 1160 1 1. 328 326 Calculations approved byACCA-to meet all requirements of Manual J 8th Ed. . -�- wrightsoft, 2017-Apr-11 09:29:38 .�P. Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N + wrightsoft RighW@ Worksheet Job: Entire House Date` QUICK CALCS, INC. By: .317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM �1 Room name WIC KrrCHEN 2 EVosed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 9.0 ft 54.0 ft2 1.0 x 1720 ft 172.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load . Area (ft') Load number (Btuh/ft'L-"F) (Btu 2) or perimeter (ft) (Eat h) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Grass WP/S Heat Cool 6 ;4AS-2 _: 13AAocs .."0.143 0.770 0.143 �n. ` . ri a 4;00: 21:56 4.00 2:55 19:31 2.55 :0 0 0 U 0 .0 p 0 0. ., 0 0 0 ; -,0 0 0 , 0 0. 0 0 0 0 0 0 0 11 -G 1A-c1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W.. ._ ,13A-4ws 0:143 se. 4.00 255 0 0 0.• 0 0 0 -0 0 y/ I-C 13AAocs 1Aclom 0.143 1.270 s s 4.00 35.56 255 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1:1:2-4M-2om 13A-0ocs : '1Ac1om - 0.143 1.270 w w 4.00, 35.56 255 • 55.21 . 0 0 0 0 0 0 .0 0 0' 6 0 0 A 0 0 ' 0 P . 12C-0sw .0.770 0.091 .w - 21:56 2.55 19.31 1.28 0 0 . 0 0 0 0 0 0 0 64 0: 64 0 163 0 82 Al ,16A-30Mu"., 0.032 .. twiv : -2 32 54 54 48 .. ; 125 .-. ,172 172 154 .399 F 22A tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less e)demal load 0 0 .0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49%1 15 57 32%1 499/6 100 1126 Total room load 64 174 418 3437 Air required (cfm) 31 8 21 153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. --, wcightsoft• . Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - - wrightsofta Right-M Worksheet Job: Entire House Bate` By: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@,AOL.COM ) Room name BATH BEDROOM-2 2 wall 5.0 ft 34.2 ft 3 =ed Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 9.0 x 5.0 ft 1.0 x 203.5 ft 5 Room area 45.0 ft2 203.5 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) number (Btuh/ft'L°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 _yJ 13A,ocs 0:143 ri ° 4.00 2.55 40 40 160 ;: 102 • 128 .- 128 ; 519 326; ;4A5 tom := 0.770 n ; • 2158 19:31; 0 ' . 0. 0 a 0 , 0 13A-4ocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143 11 1Ac1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 W V�1 13A-0ocs 13A-4ocs 0.143 0.143 se s .4.00 4.00 2.55 2.55 0 0 0 0 0 0 0 0 34 32 34 32 136 128 86 81 I---G IA-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A41ocs 0.143 w 4.00 2.55 0' 0 0 0 0• 0 0 0 1A c1om; 1.271 w 35.56 55:21 0 0 0, 0 0 0 0; 0, „4P 2om 12C-0sw 0770 0.091 .w - 21 56 2.55 19 31 1.28 0 0 0 0 0 0 ' U 0 0 '0.-M. 0 0 0 0 0 P 0.032 - -. .0.90. 232 45: 45.. 40., . 104; .. 204 `„ . 204 . :..182 `' .. 472 F 22A:tp1 0.989 - 27.69 0.00 45 5 138 0. 204 34. 946 0 6 c)AFD excursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 01 0 0 13 internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 320% 490/c 135 104 32% 49% 1131 1764 Total room load 560 318 4702 5203 Air required (cfm) 28 14 232 232 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 6A -�- wrigFftsoft' Right -Suite@ Universal2017 17.0.14 RSU08101 2017-Apr-11 0 Page 3 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N + wrightsoft' Right-M Worksheet Job: Entire House Date` By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM �1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 , . 13A4ocs ., ;4A5 tom ; 0:143 :0)770 n `r . n ` 4.00, 21 t56 -2 56 19.31 . 0 0 0 0 0 : 0 :. 0 0 - . 255 38 -. 217 - 0 869 : 815 'S52 730 T=13AAocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 11 1A-clom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -G W. V�/ L--C :1MA= 13AAocs 1A-clom 0;143 0.143 1.270 se s s .4.00 4.00 35.56 2.55 2.55 34.77 0 48 0 0 48 0 0 192 0 0 122 0 0 0 0 0 0 0 .0 0 0 0 0 0 13"&s - 1Aclom, . - 0.143,- 1,270 w w 4:00 35.56 2.55 55.21 0 .0 0 0 0 0 0 . 0 206 . 0 165 0 661 0, 420 . 0 4A5 tom: ;0 770 . w 27.56 19:31 0. 0.: 0 0. 41 41 :' WQ > 788 P 12C-0sw 0.091 - 2.55 1.28 56 56 143 72 0 0 0 0 C :16A-30md. ,: '0 032 r . = ' : ;0 90 :.. 2 3..2 ` ' 42' . 42 . 38 ... 97, ,.. 526 , 526 : 471 : ,. . -1220 F 22A-tpl ol 0.989 27.69. 0.00 42 6 166 0. 526. 47 1302. 0 6 c)AED excursion -22 668 Envelope loss/gain 539 276 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 1 01 0 Subtotal Qines 6 to 13) 643 298 5994 5112 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 321/o 49% 204 145 32% 49% .18991 2490 Total room load 846 443 7892 7602 Air required (cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �A -- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 4 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N c wriohtsoft° RighW@ Worksheet Job: ERM6 House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 E)gmed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 50.0 ft 7.0 x 8.0 ft 5 Room area 50.0 ft2 56.0 ft2. Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2L°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter. (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A�ocs : -0.143 n; 4s00 2'55 8 8 32 _ .. 20 -:: 0 `- 0 `: 0 0 :4A5-2om - . 0.770 n'". 24:56 19:3.1 0 .. 0 .. 0 • .. 0 ' .. 0.: 0.. 0.. 13AAocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 IA-clom 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 6.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W 13A4ocs O.-W se 4.00 2.55 0 0 0. 0 0 0 6 0 t-G 13A-4ocs 0.143 s 4.00 2.55 0 0 0 0 64 57 228 145 1Ac1om 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13A-4ocs .0.143 w 4.00 2.55 0 0 0 .0 0 0 .0 0. 1Ac1om 1.270 w. 35.56 5521 0 0 0 0 -ID 0: 0 -0 4A5 tom .: 0 770 , :w: ` , 21:51 19r31 0 . 0 : 0 :0 `: 6 b 0 0 P 12C-0sw, 0.091 - 2.55 1:28 72 72. 183 92 0 0 0 0 C., .. ,16A-30md . 0:032 '. - : .0190 .. 2132 .50 50 45 ;. • 116 ... :56 ` = 56 ' ..:..-56 130 F 22/Mtpl 0.989 - 27.69 0.00. 50 7 194. 0 56 8 222. 0 6 c)AED ecuision 39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 885. . 516 Less extemal.load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32% -7 49% 280 251 Total room load 1202 787 1166 768 Air required (cfm) 59 35 58 34 Calculations approved byACCA to meet all requirements of Manual .J 8th Ed. '' wrtightsOft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-19 0 Page 5 ...nick Calcs%DocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N -f° wrightsoft- Duct System Summary Dab Entire House BY: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM Project• • For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 .in H2O 0.260 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (in) Duct Matl . Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 OxO VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox 0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 .135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 SO LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BAn+A h 768 58 34 0 0 ox0 VIFx 0 0 wlc c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x - 0 VinlFlx ti wri htSoft° 2017-Apr-1109:29:38 9 Right -Suite® Universal 2017 17.0.14 RSU08101 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 1 r Return Branch Detail Table Name Grille Size (in) . Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm). Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 OxO. 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft° 2017-Apr-1109:29:38 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N