FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: THE GRAND CARLTON SCE NNF_D
Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT BY
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL ,^ A Permit Number:
St Lucie Coulii /
Owner: Q i vc
Jurisdiction:
Design Location: FL, ST_LUCIE_CO_INTL
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1437.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Exterior
R=11.0 187.33 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1446.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (ft2) 1446
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(139.2 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 320
a. U-Factor: Dbl, U=0.54 99.23 ft2
SHGC: SHGC=0.25
b. U-Factor: Dbl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.586 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1446.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1446.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.096 Total Proposed Modified Loads: 46.91
PASS
Total Baseline Loads: 48.19
I hereby certify that the plans and specifications covered by
Review of the plans and
04E S qTB
this calculation are in compliance with the Florida Energy
specifications covered by this
04
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
DATE:
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
G'Orj WME
OWNER/A P5-
BUILDING OFFICIAL:
DATE: N
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
FILE CG,��`
12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: ^ THE GRAND CARLTON Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Own; r:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135
Street:
WYNNE DEVELOPME
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
TMY Site Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST_LUCIE_CO_INTL FL VERO_BEACH_MUNI 2 39
90
70
75 299
58
Medium
BLOCKS
Number Name
Area Volume
1 Entire House
1446 11568
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM
234 1872 No
2
1
1 Yes
Yes
Yes
2 WIC
54 432 No
0
1 No
Yes
Yes
3 MASTER BATH
63 504 No
0
1 Yes
Yes
Yes
4 M.BATH
56 448 No
0
1 Yes
Yes
Yes
5 KITCHEN
172 1376 Yes
0
1 No
Yes
Yes
6 BATH
45 360 No
0
1 Yes
Yes
Yes
7 BEDROOM 2
204 1632 No
1
1
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
526 4208 No
0
1 Yes
Yes
Yes
10 FOYER
50 400 No
0
1 Yes
Yes
Yes
FLOORS
Floor Type
Space' Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 40 ft 0
234 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
54 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH 9 ft 0
63 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
172 ft2
__--
0 1
0
6 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft2
---
0 1
0
7 Slab -On -Grade Edge Insulatio
BEDROOM 2 34.2 ft 0
204 ft2
----
0 1
0
12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8SIab-On-Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 47 ft 0
526 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio FOYER 7 ft
0
50 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
#
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Gable or shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1446 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
234 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
54 ft2
0.1
Wood
3
Under Attic (Vented) MASTER BATH
30
Blown
63 ft2
0.1
Wood
4
Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
5
Under Attic (Vented) KITCHEN
30
Blown
172 ft2
0.1
Wood
6
Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
7
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
526 ft2
0.1
Wood
10
Under Attic (Vented) FOYER
30
Blown
50 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing
Solar
Belo w
1
N=>SE
Exterior Concrete Block - Ext InsiflEDROOM
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
2
S=>NW
Exterior Concrete Block - Ext Insi3EDROOM
4.1 18
0 8
0
144.0 ft2
0
0
0.5
0
3
W=>NE
Exterior Concrete Block - Ext InsdBEDROOM
4.1 13
0 8
0
104.0 ft2
0
0
0.5
0
4
S=>NW
Exterior Concrete Block - Ext InsMASTER BA
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
5
S=>NW
Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
6
N=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
7
N=>SE
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
8
E=>SW
Exterior Concrete Block - Ext InfiEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.5
0
9
SE=>W
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.5
0
_ 10
S=>NW
Exterior Concrete Block - Ext InJ3ffDR0OM 2
4.1 4
0 8
0
32.0 ft2
0
0
0.5
0
_ 11
S=>NW
Exterior Concrete Block - Ext InsalAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.5
0
12
N=>SE
Exterior Concrete Block - Ext InsGREAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.5
0
12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Belo
Space
le Et
In
Et In Area
R-Vahle
Erart*on
Ahsor
w
rrade%
13
W=>NE
Exterior
Concrete Block - Ext InsGiREAT/DINI
4.1 21
0
8 0 168.0 ft2
0
0
0.5
0
14
N=>SE
Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0 8.0 ft2
0
0
0.5
0
15
E=>SW
Exterior
Concrete Block - Ext Insul FOYER
4.1 6
0
8 0 48.0 ft2
0
0
0.5
0
16
N=>SE
Exterior
Frame - Wood GREAT/DINT
11 23
5
8 187.3 ft2
0.23
0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E=>SW
Insulated FOYER
None
.28 3
6 8
20 ft2
/
Wall
V #
Ornt ID
Frame
Panes
NFRC
U-Factor SHGC
1
W=>NE 3
Metal
Low-E Double
Yes
0.54
0.25 3
# Floor Area
1 315 ft2
I # Scope Method
I 1 Wholehouse Proposed ACH(50)
2
2 S=>NW 5 Metal Low-E Double Yes 0.54 0.25 6
3 E=>SW 8 Metal Low-E Double Yes 0.54 0.25 2
3
4 N=>SE 12 Metal Low-E Double Yes 0.54 0.25 3
6
5 W=>NE 13 Metal Low-E Double Yes 0.55 0.25 4
0
# Floor Area
1 315 ft2
I # Scope Method
I 1 Wholehouse Proposed ACH(50)
GARAGE
tiling Area Exposed Wall Perimeter A
315 ft2 24 ft
INFILTRATION
SLA CFM 50 ELA EgLA
.000356 1349.6 74.09 139.34
HEATING SYSTEM
Overhang
Area Depth Separation Int Shade Screening
.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5
.9 ft2 1 ft 0 in 1 ft 4 in None None
.2 ft2 1 ft 0 in 1 ft 4 in None None
.8 ft2 1 ft 0 in 1 ft 4 in None None
.0 ft2 10 ft 0 in 1 ft 4 in None None
Wall
8ft
ACH
.2669
Wall Insulation
11
ACH 50
7
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
12/10/2017 5:25 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
Wall
8ft
ACH
.2669
Wall Insulation
11
ACH 50
7
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1
12/10/2017 5:25 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
# Area
Volume
FEF
None
None
ft2
DUCTS
/
-- Supply —
— Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 320 ft2
Attic
80 ft2 Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Heating HJan
H Feb
ki Mar
Apr I
May Jun riJul
i May ri
Aug
ri
Sep
rl
Oct
Oct
Nov
H Nov
Dec
H
Venting Jan
Feb
Mar
Jun Jul
Aug
Sep
Oct
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
1 �
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: THE GRAND CARLTON Builder Name: WYNNE DEVELOPMENT
Street: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, ST LUCIE_CO_INTL
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
,vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
12/10/2017 5:25 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftZ
7. Windows-
Description
a. U-Factor:
Dbl, U=0.54
SHGC:
SHGC=0.25
b. U-Factor:
Dbl, U=0.55
SHGC:
SHGC=0.25
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
WYNNE DEVELOPMENT, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ftZ
b. Frame - Wood, Exterior
R=11.0
187.33 ftZ
1
c. N/A
R=
ftz
2
d. N/A
R=
ftZ
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ftZ
1446
b. N/A
R=
ftZ
Area
c. N/A
R=
ftZ
99:23 ftZ
11. Ducts
R ftZ
a. Sup: Attic, Ret: Attic, AH: Attic
6 320
40.00 ftZ
12. Cooling systems
kBtu/hr
Efficiency
ftZ
a. Central Unit
34.8 SEER:15.00
B. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ftZ
13. Heating systems
a. Electric Heat Pump
3.586 ft.
0.250
Area
14. Hot water systems
1446.00 ftZ
a. Electric
ftZ
b. Conservation features
ftZ
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: , City/FL Zip:Sk
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
Pstat
e-t1j4iE SrArFo
Gj'�rr�yy��rr�''• a r` �' .��` UN'
tiff
�caD ��v5
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
12/10/2017 5:25 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
- wrightsoft® Project Summary Date:
Entire House By:
QUICK CALLS, INC.
317 ST.-LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466.6799 Fax 772A66-6796. Email: QUIC.KCALCS(AOL.COM.
For: THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
Notes: Q
Design Information
Weather. Fort Pierce,' FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Outside db
90
OF
Inside db 70 OF
Inside db
75
OF
Design TD 28 OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 17848 Btuh
Structure
17520
Btuh
Ducts 5654 Btuh
Ducts
8536
Btuh
Central vent (0 cfm) 0 Btuh
Central vent (0 cfm)
0
Btuh
(none)
(none)
Humidification 0 Btuh
Blower
0
Btuh
Piping 0 Btuh
Equipment load 23503 Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipment load
0.95
24753.
Btuh
Infiltration
sensible
Method Simplified
Latent Cooling -Equipment
Load Sizing
Construction quality Average
Fireplaces 0
Structure
3203
Btuh
Ducts
2318
Btuh
Central vent (0 cfm)
0
Btuh
Heat' Cool'
%
(none)
Area (ft2) 1446 14
Equipment latent load
-5521
Btuh
Volume (W) 12511 12511
Air changes/hour 0.45 0.23
Equipment total load
30274
Btuh
Equiv. AVF (cfm) 94 48
Req. total capacity at 0.70 SHR
2.9
ton
Heating Equipment Summary
Cooling Equipment
Summary
Make Carrier
Make Carrier
Trade CARRIER AIR CONDITIONING
Trade CARRIER AIR CONDITIONING
Model 25HBC536A" 030
Cond 25HBC536A`030
AHRI ref 7914585
Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 8.5 HSPF
Efficiency 12.0 EER,
15 SEER
Heating input
Sensible cooling
24360
Btuh
Heating output 34600 Btuh @ 47°F
Latent cooling
10440
Btuh
Temperature rise 27 OF
Total cooling
.
34800
Btuh
Actual'air flow 1160 cfm
Actual air flow
1160.
cfm
Air flow factor 0.049 cfm/Btuh
Air flow factor
0.045
cfm/Btuh
Static pressure 0.50 in H2O
Static pressure
0:50
in H2O
Space thermostat
Load sensible heat ratio
0.83
Capacity balance point = 32 OF
Backup:
Input — 7 kW, Output = 23009 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
+ wrightsoft` 2017-Apr-11 09:29:38
ACC Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
wrigntsof . Right-JO Worksheet
Entire House
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946-Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM
Job:
Date:
By:
1
Room name
Entire House
BEDROOM
2
Exposed wall
156.2 ft
49.0 ft
3
Room height
8.7 ft d
8.0 ft heat/cool
4
Room dimensions
1.0 x 297.0 ft
5
Room area
1445.5 ftz
297.0 ftz
Ty
Construction
number
U-value
(Btuh/ftk*F)
Or
HTM
(Btuh/ft2)
Area (ft-)
or perimeter (ft)
Load
(Btuh)
Area (ft')
or perimeter (ft)
Load
(Btuh) .
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
?
13A flocs ':
;.0.143
n ,,
4:00:
2.55
503
465
1862
-: 1184
. - 72
72
. 288:
183
4A5 tom •'•" ,
.0;770
, n' :
21,56.
. 19 31
; 38
0.
815
730.
.'0
'0
13A-4ocs
0.143
a
4.00
2.55
128
83
333
212
0
0
0
0
1Ac1om
1.270
a
35.56
87.29
24
2
848
2082
0
0
0
0
11
11DO
0.390
a
10.92
11.31
21
21
229
238
0
0
0
0
W
13A-0ocs
0.143
se
4.00
2.55
34
34
136
86
0
0
0
` 0
VIJ
13AAocs
0.143
s
4.00
2.55
360
353
1414
899
216
216
865
550
1Ac1om
1.270
s
35.56
34.77
7
7
247
241
0
0
0
0
-a
13A-46cs
0:143
w
4:00
2.55
310
237
949
603
104
72
288
183
1"Ac1om
1.270
w
35t56
55.21
32
2
1140
1770
32
2
1140
1770.
.. _
0}770
w
21.56
•19.31
41
. 41
'. 880
::. 788
0
- .0
.. 0:
.. 0
P
,4A5r2om
12C-0sw
0.091
-
2.55
1.28
192
192
489
246
0
0
0
0
C ..
16Q-30md
0.032
-.
0 90'
,.. : 2.3.2
1446'
1446
-. 1296
:: 3354
297'
:,.., 297
` .:... 266
F
22A tpl
0.989
-
27.69
0.00
1446
156
4325
0
297
49
1357
0
6
c)AED e)xursion
918
627
Envelope loss/gain
14961
13349
4204
4003
12
a) Infiltration
2887
791
848
232
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
6
1380
3
690
Appliances/other
2000
0
Subtotal (lines 6 to 13)
17848
17520
5053
4925
Less extemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
17848
1-1520
5053
4925
15
Ductloads
32%1
490/o
5654
8536
32%
49%
1601
2400
Total room load
23503
26056
6653
7325
Air required (cfm)
1160
1160
1
1.
328
326
Calculations approved byACCA-to meet all requirements of Manual J 8th Ed.
. -�- wrightsoft, 2017-Apr-11 09:29:38
.�P. Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1
...ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
+ wrightsoft RighW@ Worksheet Job:
Entire House Date`
QUICK CALCS, INC. By:
.317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM
�1
Room name
WIC
KrrCHEN
2
EVosed wall
O ft
O ft
3
Room height
8.0 ft heat/cool
8.0 ft heat/cool
4
5
Room dimensions
Room area
6.0 x 9.0 ft
54.0 ft2
1.0 x 1720 ft
172.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
. Area (ft')
Load
number
(Btuh/ft'L-"F)
(Btu 2)
or perimeter (ft)
(Eat h)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cool
Grass
WP/S
Heat
Cool
6
;4AS-2 _:
13AAocs
.."0.143
0.770
0.143
�n. `
. ri
a
4;00:
21:56
4.00
2:55
19:31
2.55
:0
0
0
U
0
.0
p
0
0.
., 0
0
0
; -,0
0
0
, 0
0.
0
0
0
0
0
0
0
11
-G
1A-c1om
11DO
1.270
0.390
a
a
35.56
10.92
87.29
11.31
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
W.. ._
,13A-4ws
0:143
se.
4.00
255
0
0
0.•
0
0
0
-0
0
y/
I-C
13AAocs
1Aclom
0.143
1.270
s
s
4.00
35.56
255
34.77
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1:1:2-4M-2om
13A-0ocs :
'1Ac1om -
0.143
1.270
w
w
4.00,
35.56
255
• 55.21
. 0
0
0
0
0
0
.0
0
0'
6
0
0
A
0
0
' 0
P
.
12C-0sw
.0.770
0.091
.w
-
21:56
2.55
19.31
1.28
0
0
. 0
0
0
0
0
0
0
64
0:
64
0
163
0
82
Al
,16A-30Mu".,
0.032
..
twiv
:
-2 32
54
54
48
.. ;
125
.-.
,172
172
154
.399
F
22A tpl
0.989
-
27.69
0.00
54
0
0
0
172
0
0
0
12
a) Infiltration
0
0
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
2000
Subtotal (lines 6 to 13)
48
117
317
2311
Less e)demal load
0
0
.0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
48
117
317
2311
15
Duct loads
32%
49%1
15
57
32%1
499/6
100
1126
Total room load
64
174
418
3437
Air required (cfm)
31
8
21
153
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
--, wcightsoft• . Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 2
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
- - wrightsofta Right-M Worksheet Job:
Entire House Bate`
By:
QUICK CALLS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@,AOL.COM
)
Room name
BATH
BEDROOM-2
2
wall
5.0 ft
34.2 ft
3
=ed
Room height
8.0 ft heat/cool
8.0 ft heat/cool
4
Room dimensions
9.0 x 5.0 ft
1.0 x 203.5 ft
5
Room area
45.0 ft2
203.5 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
number
(Btuh/ft'L°F)
(Btuhlft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
_yJ
13A,ocs
0:143
ri °
4.00
2.55
40
40
160
;: 102
• 128
.- 128
; 519
326;
;4A5 tom :=
0.770
n ;
• 2158
19:31;
0
' . 0.
0
a
0
,
0
13A-4ocs
0.143
a
4.00
2.55
0
0
0.
0
80
56
225
143
11
1Ac1om
11DO
1.270
0.390
a
a
35.56
10.92
87.29
11.31
0
0
0
0
0
0
0
0
24
0
2
0
848
0
2082
0
W
V�1
13A-0ocs
13A-4ocs
0.143
0.143
se
s
.4.00
4.00
2.55
2.55
0
0
0
0
0
0
0
0
34
32
34
32
136
128
86
81
I---G
IA-c1om
1.270
s
35.56
34.77
0
0
0
0
0
0
0
0
13A41ocs
0.143
w
4.00
2.55
0'
0
0
0
0•
0
0
0
1A c1om;
1.271
w
35.56
55:21
0
0
0,
0
0
0
0;
0,
„4P 2om
12C-0sw
0770
0.091
.w
-
21 56
2.55
19 31
1.28
0
0
0
0
0
0
' U
0
0
'0.-M.
0
0
0
0
0
P
0.032
- -.
.0.90.
232
45:
45..
40.,
. 104;
.. 204
`„ . 204
. :..182
`' .. 472
F
22A:tp1
0.989
-
27.69
0.00
45
5
138
0.
204
34.
946
0
6
c)AFD excursion
-16
-85
Envelope loss/gain
339
190
2978
3106
12
a) Infiltration .
87
24
593
162
b) Room ventilation
0
01
0
0
13
internal gains: Occupants @ 230
0
0
1
230
Appliances/other
0
0
Subtotal (lines 6 to 13)
425
214
3571
3498
Less extemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
425
214
3571
3498
15
Duct loads
320%
490/c
135
104
32%
49%
1131
1764
Total room load
560
318
4702
5203
Air required (cfm)
28
14
232
232
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
6A -�- wrigFftsoft' Right -Suite@ Universal2017 17.0.14 RSU08101 2017-Apr-11 0 Page 3
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
+ wrightsoft' Right-M Worksheet Job:
Entire House Date`
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM
�1
Room name
LAUNDRY
GREAT/DINING
2
Exposed wall
6.0 ft
47.0 ft
3
Room height
8.0 ft heat/cool
9.8 ft heat/cool
4
5
Room dimensions
Room area
7.0 x 6.0 ft
42.0 ft2
1.0 x 526.0 ft
526.0 ft2
Ty
Construction
number
U-value
(Btuh/ft2-°F)
Or
HTM
(Btuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Area (ft2)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
,
.
13A4ocs .,
;4A5 tom ;
0:143
:0)770
n `r
. n `
4.00,
21 t56
-2 56
19.31
. 0
0
0
0
0
: 0
:. 0
0
- . 255
38
-. 217
- 0
869
: 815
'S52
730
T=13AAocs
0.143
a
4.00
2.55
0
0
0
0
0
0
0
0
11
1A-clom
11DO
1.270
0.390
a
a
35.56
10.92
87.29
11.31
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
-G
W.
V�/
L--C
:1MA=
13AAocs
1A-clom
0;143
0.143
1.270
se
s
s
.4.00
4.00
35.56
2.55
2.55
34.77
0
48
0
0
48
0
0
192
0
0
122
0
0
0
0
0
0
0
.0
0
0
0
0
0
13"&s -
1Aclom, . -
0.143,-
1,270
w
w
4:00
35.56
2.55
55.21
0
.0
0
0
0
0
0
. 0
206
. 0
165
0
661
0,
420
. 0
4A5 tom:
;0 770
. w
27.56
19:31
0.
0.:
0
0.
41
41
:' WQ
> 788
P
12C-0sw
0.091
-
2.55
1.28
56
56
143
72
0
0
0
0
C
:16A-30md. ,:
'0 032
r . = '
: ;0 90
:.. 2 3..2
` ' 42'
. 42
. 38
... 97,
,.. 526
, 526
: 471
: ,. . -1220
F
22A-tpl
ol
0.989
27.69.
0.00
42
6
166
0.
526.
47
1302.
0
6
c)AED excursion
-22
668
Envelope loss/gain
539
276
4997
4379
12
a) Infiltration
104
28
997
273
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
2
460
Appliances/other
1
01
0
Subtotal Qines 6 to 13)
643
298
5994
5112
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
643
298
5994
5112
15
Duct loads
321/o
49%
204
145
32%
49%
.18991
2490
Total room load
846
443
7892
7602
Air required (cfm)
42
20
390
338
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
�A -- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 4
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
c
wriohtsoft° RighW@ Worksheet Job:
ERM6 House Date:
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
FOYER
M. BATH
2
E)gmed wall
7.0 ft
8.0 ft
3
Room height
8.0 ft
heat/cool
8.0 ft
heat/cool
4
Room dimensions
1.0
x
50.0 ft
7.0 x
8.0 ft
5
Room area
50.0 ft2
56.0 ft2.
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft2)
Load
number
(Btuh/ft2L°F)
(Btuh/ft2)
or perimeter
(ft)
(Btuh)
or perimeter.
(ft)
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
6
13A�ocs :
-0.143
n;
4s00
2'55
8
8
32
_ ..
20 -::
0
`-
0
`:
0
0
:4A5-2om - .
0.770
n'".
24:56
19:3.1
0
..
0
..
0
• ..
0 '
.. 0.:
0..
0..
13AAocs
0.143
a
4.00
2.55
48
27
108
69
0
0
0
0
IA-clom
1.270
a
35.56
87.29
0
0
0
0
0
0
0
0
11
11DO
6.390
a
10.92
11.31
21
21
229
238
0
0
0
0
W
13A4ocs
O.-W
se
4.00
2.55
0
0
0.
0
0
0
6
0
t-G
13A-4ocs
0.143
s
4.00
2.55
0
0
0
0
64
57
228
145
1Ac1om
1.270
s
35.56
34.77
0
0
0
0
7
7
247
241
13A-4ocs
.0.143
w
4.00
2.55
0
0
0
.0
0
0
.0
0.
1Ac1om
1.270
w.
35.56
5521
0
0
0
0
-ID
0:
0
-0
4A5 tom .:
0 770
, :w: `
, 21:51
19r31
0
.
0
:
0
:0 `:
6
b
0
0
P
12C-0sw,
0.091
-
2.55
1:28
72
72.
183
92
0
0
0
0
C., ..
,16A-30md .
0:032
'. - :
.0190
..
2132
.50
50
45
;. •
116 ...
:56
`
= 56
' ..:..-56
130
F
22/Mtpl
0.989
-
27.69
0.00.
50
7
194.
0
56
8
222.
0
6
c)AED ecuision
39
-38
Envelope loss/gain
792
496
747
478
12
a) Infiltration
121
33
138
38
b) Room ventilation
0
0
0
0
13
Internal gains:
Occupants @
230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
913
529
885.
.
516
Less extemal.load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
913
529
885
516
15
Duct loads
32%
49%
289
258
32%
-7
49%
280
251
Total room load
1202
787
1166
768
Air required (cfm)
59
35
58
34
Calculations approved byACCA to meet all requirements of Manual .J 8th Ed.
'' wrtightsOft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-19 0 Page 5
...nick Calcs%DocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N
-f° wrightsoft- Duct System Summary Dab
Entire House BY:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM
Project• •
For. THE GRAND CARLTON
WYNNE DEVELOPMENT, FT. PIERCE, FL
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50 in H2O
0 in H2O
0.50 .in H2O
0.260 / 0.250 in H2O
0.285 in/100ft
1160 cfm
Cooling
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.285 in/100ft
1160 cfm
176 ft
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(In)
H x W
(in)
Duct
Matl .
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 560
28
14
0.364
4.0
OxO
VIFx
22.4
115.0
st1
BEDROOM 2
h 4702
232
232
0.360
7.0
OxO
VIFx
23.9
115.0
st1
BEDROOM -A
h 3327
164
163
0.300
6.0
Ox 0
VIFx
31.8
135.0
st2
BEDROOM-B
h 3327
164
163
0.285
6.0
Ox0
VIFx
40.6
135.0
st2
FOYER
h 1202
59
35
0.505
4.0
ox0
VIFx
4.0
95.0
GREAT/DINING
h 3946
195
169
0.300
7.0
ox0
VIFx
31.8
135.0
st2
GREAT/DINING-A
h 3946
195
169
0.300
7.0
Ox0
VIFx
31.8
.135.0
st2
KITCHEN
c 3437
21
153
0.379
6.0
Ox 0
VIFx
17.0
115.0
SO
LAUNDRY
h 846
42
20
0.361
4.0
OxO
VIFx
23.3
115.0
st1
M. BAn+A
h 768
58
34
0
0
ox0
VIFx
0
0
wlc
c 174
3
8
0.309
4.0
Ox0
VIFx
27.0
135.0
st2
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FR
(fpm)
(In)
(in)
Material
Trunk
st2
Peak AVF
721
672
0.285
918
12.0
0 x 0
VinlFlx
st1
st1
Peak AVF
1043
1091
0.285
1020
14.0
0 x - 0
VinlFlx
ti wri htSoft° 2017-Apr-1109:29:38
9 Right -Suite® Universal 2017 17.0.14 RSU08101
...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 1
r
Return Branch Detail Table
Name
Grille
Size (in) .
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm).
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
OxO.
1160
1160
0
0
0
0
Ox 0
VIFx
wri htsoft° 2017-Apr-1109:29:38
9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2
...uick CalcslDocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N