HomeMy WebLinkAboutRevision 3-14-13I 1 I J DISTANCE i OUTSIDE e CORRIDOR LEV 48 SF ENSURE THIS A 1 HR 11 FIRE WALL TO U/S OF DECK PER UL#U465. DETAIL INCLUDED WITH THESE DOCUMENTS. ENSURE THIS DOOR & FRAME HAS CLOSER, PUSH —PANEL HARDWARE MIN. 45 MINUTE FIRE RATINGS & UL LABELS oo 0000ao 0000 00000 000000 0 PLUMBING FIXTURES CALC: ASSUMING EXCEPTION FOR GAMES & EMPLOYEES OCCUPANY APPROVED: PLUMBING FIXTURES PER TABLE 403.1 2010 FPC: FOR 82 MALES: /125 = 1 WC: FOR 82 FEMALES: /65 2 WC; TOTAL WC'S REQUIRED: 3 LAV'S AT 1 /200 PEOPLE = MIN. (1) FOR EACH GENDER; 1) SERVICE SINK REQUIRED; HIGH LOW DRINKING FOUNTAINS EXISTING TO REMAIN. INTERIOR FINISHES: 1, NO CHANGE TO EXISTING FINISHES EXCEPT IN RESTROOM REMODEL, WHICH ARE TO MATCH EXISTING; 2. MINIMUM FINISHES TO MEET BELOW, AS PREVIOUSLY APPROVED BY COUNTY; 3. INTERIOR WALL & CEILING FINISHES SHALL BE AS FOLLOWS: GENERAL ASSEMBLY AREAS AND LOBBIES: INTERIOR WALL AND CEIL'G FIN. MATERIALS SHALL BE CLASS 'A' OR CLASS 'B'; REMAINING SPACES: CLASS B (<76 FLAME SPREAD & 451 SMOKE DEV.); ENSURE 20MIN DOOR w/ CLO A MAX. TRAVEL CORRIDORXw 'DISTANCE: O103'-0" ENSURE. 20MIN. DOOR w/ CLOSER COUNSELING RM T / 0 FI C WAITING AREA / aD A I THIS ROOM AREA:309 SF NEW. DIVIDED BY 15 SF = 21 EMERGENCE OCCUPANTS LIGHT CORRIDOR WALLS ARE i 1 HOUR . ENSURE 20MIN. RATED FIRE BARRIERS DOOR w/ CLOSER mX. j ELIMINATE OR REVERSE.. THIS DOOR TO OUTSWING. IF DOOR TO REMAIN, DOOR &. FRAME MUST HAVE A CLOSER, PUSH —PANEL HARDWARE & MIN. '20 MINUTE FIRE RATINGS. R), COUNSELING RMTHISROOMAREA:382 SF w/ 37 SEATS OCCUPANTS) GROUP COUNSELLING SEATING 6--0" 3" SANI LINE FOR ill FIXTURES ALONG 12" PLUMBING WALL TO BE ABOVE FINISHED FLOOR DUE TO CONFLICTS IN j FLOOR BELOW. I ao MEN \\ PUT NEW FAN & II I ® A LIGHT ON SAME he ss'xw RESTROOM CIRCUIT C 1 ALL NEW FIXTURES THIS jRESTROOM LAUNDRY —TYPE JANITOR CLOSET NEW ADA \ COMPLIANT 7` HI -LOW D.F. ENSURE MIN. / 18" HERE w/ HI -LOW D.F. NEW 12" PLUMBIN( WALL FOR WALL MOUNT VALVE WC. I NEW WALL MINT WC'S & EXISTING LAV'S RELOCATED THESE TWO RESTROOMS. KEEP ON SAME CIRCUITS COUNSELING RM 60'-0" 24'-6" B BU NES -OFFI ACC SORY ARE,A 203F ELECTRICAL_ NOTES:_ 1. ALL LOAD CALC'S TO BE CHECKED BY FLORIDA LICENSED ELECTRICIAN; 2. ALL WORK TO FLORIDA ELECTRICAL CODE & REQUIREMENTS OF FPL; 3. CONDUCTORS TO BE #12 CU, OFF EXISTING CIRCUIT FROM EXISTING PORCH. ALL INSULATION TO BE THHN; CONDUIT AS FOLLOWS: PVC BELOW GROUND; RIGID FROM U/G TO SERVICE; BOX FOR EXTERIOR LITE ON HOUSE; AC, MC OR EMT CONDUIT ELSEWHERE. 4. PROTECTIVE RATINGS SHALL COMPLY WITH NEC 110-9 AND NEC 110-10. 5. EXISTING ELECTRICAL FIXTURES ARE NOT SHOWN, EXCEPT LIFE SAFETY DEVISES & NEW FIXTURES FOR THIRD RESTROOM & SOME ADDITIONAL EMERG. LIGHTS AS INDICATED; 6. EXISTING PANEL TO HAVE MAIN CIRCUIT BREAKER AT METER PACK, PER NEC 230-70-A-1; 7. PLACE NEW RESTROOM FAN & LIGHT ON EXISTING RESTROOM CIRCUIT; 8. PLACE (4) NEW EMERG. LITES ON EXISTING EMERG. LIGHTS CIRCUIT; 2ND FLOOR TENANT SPACE ELECTRICAL LOAD - 200A SERVICE PER NEC 220.87, IN LIEU OF A CALCULATION, 13 MONTHS OF DEMAND LOAD ARE PROVIDED FOR THIS SERVICE. THE ADDITION OF (1) EMERGENCY LIGHT, (1) RESTROOM LIGHT & (1) RESTROOM FAN, TOTAL OF NEW 200VA, FALLS WITHIN THE LOAD BELOW: SERVICE SINK LARGEST DEMAND READING: 3/10 OF 36,000W / 240 = 150A ® 125% = 187.5A < 200A - OK. NEW 12" O I PLUMBING WALL SANI LINE FOR FIXTURES ALONG 12" PLUMBING WALL TO BE ABOVE FINISHED JANITOR. FLOOR DUE TO CONFLICTS IN I\ CLOD FLOOR BELOW. MENI \ 1 ® \\ I 1 A wo I NEW ADA COMPLIANT Hl- LOW,I,D.F. ENSURE 20MIN. DOOR . ® LOSERHLE MEETING ROOM SEE. SEATINIG P.LAN1 THIS PAGE FOR THIS 1 REVERSE THIS N A R TO Ob- SWING ® J a. ILI 11' AREA F, OM . R: si'. LLIC4L : OLJNTY iI r-4UI ^ING DIVISION L7r`. r;EwED 9EVI J D 3Y DA" fE PUNS A D P RMIT . rz r •,;-•^:• ELIMINATE OR REVERSE THIS DOOR TO OUTSWING. IF DOOR TO REMAIN, DOOR & FRAME MUST HAVE A A CLOSER, PUSH —PANEL HARDWARE' & MIN. 20' f MINUTE FIRE RATINGS. / ENSURE 20MIN. COUNSELING ` RM DOORw/ CLOSER . ft ft A WAITING AREA l 1 r-------------- . 1 1 a COUNSELING ; COUNSELING RM I RM 1I . 1 1 15- 104" 37'- 11" 0 i RM CORRIDOR ENSURE DOOR HAS A CLOSER & PUSH —PANEL HARDWARE EXIT DOORS: V_ 1. ALL EXIT DOORS & DOORS LEADING TO THE EXITS SHALL BE EQUIPPED w/ FIRE RATED PUSH -PANEL (PANIC) HARDWARE 1 HR FIRE RATED WALL TO U/S OF DECK PER UL#U465. NEW 2x4 ® 24" O.C. w/ 1/ 2" GYP. BIRD EACH SIDE w/ 3.5" BATT INSUL. NEW 2x3 @ 24" O.C. w/ 1/2" W. P. GYP. BIRD ONE SIDE SIDE w/ 3. 5" BATT INSUL. TOTAL NET AREA:2,850 SF A-3 BTOTAL NET AREA:253 SF LESS THAN 10% FLOOR AREA) REMODEL 8c LIFE SAFETY PLAN SCALE: 1 /4"=1 '-O" RECE0 yq ` VE MAR 19 1013 Ln o zr--- o Q t C O q C jOO j r U 1 c L Q O _ 0 v r 0 C rn0 U c w r O ( D r N U) Q C 0 z n, D Q THESE DRAWINGS CONTAIN ARCHITECTURAL SYMBOLS USED FOR GRAPHIC PURPOSES ONLY. SIZE AN LOCATION MAY VARY TO MEET MANUFACTURER'S SPECIFICATIONS. DO NOT SCALE DRAWINGS. ANY QUESTIONS ABOUT DIMENSIONS, CONTACT DESIGNER. COPYRIGHT OF RAYMOND CHLAD COPY OR USE ONLY WITH PRIOR PERMISSION. ce LLI z W uj u uj uj Z0 Z W START DATE: 10.17.1 NO. REVISION/ISSUE DATE 0 1ST -REVISION 01.09.1 2ND- REVISION 02.05.1 3RD- REVISION 02.13.1 4 4TH-REVISION 03.19.1 CLIENT: DR. TOLEDO NEW LIFE 905 PRIMA VISTA BLVD PORT ST. LUCIE, FL Raym° ntl Chladny Licensed Architect #AR-0017475 A= 2 ENLARGEDRESTROOMPLANSCALE: 3/8"=1'-O" A