Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
SCANNED K BY �O�"o R405-2014 St Lurie M FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION •Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON 299 Builder Name: WYNNE DEVELOPMENT Street: THE CARLTON 299 Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: C� Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ft2 b. Frame - Wood, Adjacent R=11.0 192.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1474.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 6. Conditioned floor area above grade (ft2) 1474 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(141.3 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor: Sgl, U=0.54 101.25 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1473.5 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1473.50 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 48.42 PASS Total Baseline Loads: 48.48 I hereby certify that the plans and specifications covered by Review of the plans and STA?A this calculation are in compliance with the Florida Energy specifications covered by this D�ZKE Code. " calculation indicates compliance �O 1 with the Florida Energy Code. rurr'%' : ��°�. ��;, PREP RED Y' Before construction is completed r `' DATE: -� `� this building will be inspected for j a y �- compliance with Section 553.908 * I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. COD WE OWNER/ BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 5/31 /2017 11:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1474 Lot # Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE CARLTON 299 Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1474 11792 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 329 2632 No., 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 329 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ---- 0 1 0 5/31/2017 11:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 ` FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1553 ft2 246 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1474 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 329 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood WALLS Adjacent Space Cavity Width 10 Wall Type_ R-1/allie Et In Height Et In Area Sheathing Framing RA/al-le Erqctuon Solar Ahqor Below rr:;rip% 1 NE=>SW Exterior Concrete Block - Ext InsiBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 2 SW=>NE Exterior Concrete Block - Ext InsIREDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.6 0 3 NW=>SE Exterior Concrete Block - Ext InsiHEDR00M 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 5 NE=>SW Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 _ 6 NE=>SW Exterior Concrete Block - Ext IndMDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 7 SE=>NW Exterior Concrete Block - Ext InREDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 S=>N Exterior Concrete Block - Ext InREDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.6 0 _ 9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.6 0 12 SW=>NE Exterior Concrete Block - Ext InsL AUNDRY 4.1 6 0 8 - 0 48.0 ft2 0 0 0.6 0 13 NE=>SW Exterior Concrete Block - Ext InsGREAT/DINT 4.1 26 0 8 0 208.0 ft2 0 0 0.6 0 14 NW=>SE Exterior Concrete Block - Ext Ins6REAT/DINT 4.1 20 0 8 0 160.0 ft2 0 0 0.6 0 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 ft2 0.23 0.6 0 5/31/2017 11:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 " DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall # Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 0.54 0.25 32.9 ft2 1 ft 0 in 1 ft 4 in 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in 0.54 0.25 24.0 ft2 6 ft 0 in 1 ft 4 in 0.54 0.25 37.5 ft2 1 ft 0 in 1 ft 4 in 0.55 0.25 40.0 ft2 8 ft 0 in 1 ft 4 in Drapes/blinds None None None Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315ft2 315ft2 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1375.7 75.53 142.04 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector System Model # Collector Model # Area Storage Volume FEF None None ft2 5/31/2017 11:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM.R4n5-2W4 ' DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V • # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 85 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Heat ng HJan HFeb Mar AprApr I jMa Jun rj rl Jul Aug rl Sep ri 0 Nov Dec HDec Venting Jan Feb X Mar May Jun Jul Aug Sep Occt t X Nov Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/31/2017 11:20 AM EnergyGaugeg) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 ' FOR.M R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON 299 Builder Name: WYNNE DEVELOPMENT Street: THE CARLTON 299 Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air. barrier shall be installed in the building envelope. Exterior thermal envelope containsa continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall,doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and . framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall. extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 5/31/2017 11:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORt4 R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 .The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows** Description a. U-Factor: Sgl, U=0.54 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 SHGC: SHGC=0.25 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: THE CARLTON 299, FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation _ Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1250.00 ftz b. Frame - Wood, Adjacent R=11.0 192.00 ft 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1474.00 ft2 1474 b. N/A . R= ft2 Area c. N/A R= ft2 101.25 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 325 40.00 ft2 12. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A, R= c. N/A R= ft2 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPR8.50 3.832 ft. 0.250 Area 14. Hot water systems 1473.50 ft2 a. Electric Cap: 40 gallons EF: 0.97 ft2 b. Conservation features ft2 None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: �(p Address of New Home: �CQ�b. City/FL Zip: s\,_ ItIR `q 0 .t%E ST,q?F 0 G'pD WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/31/2017 11:20 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 - - wrightsoft- Project Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN.; FT. PIERCE, FL 34946 Phone: 77246"799 Fax 772.466-6796 For: WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL ..;(Notes: Design Information Weather. Fort Pierce, FL, US Winter Design -Conditions Outside db Inside db Design TD Job: Date: By: Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 18188 Btuh Ducts 5654 Btuh Central vent (0.cfm) 0 -Btuh (none) Humidification 0 Btuh Pi in Equipment load 23842 Btuh Infiltration Method Simplified Construction quality. Average Fireplaces 0 Area (ftz) Heatingg Cooling 1474 Volume (ft3) 12227 Air changes/hour 12227 Equiv. AVF (cfm) 0 9 0.47 47 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Modelref 25H8C536A*030 AHRI 7914585 Efficiency Heating. input . Heating output Temperature rise Actual airflow Air flow factor Static pressure Capacithermostat, oint = 33 OF Backup: 8.5 HSPF 34600 Btuh @ 470F 27 OF. 1160 cfm 0.040 cfmlBtuh 0.50 in H2O Input = 7 kW,: Output = 23009 Btuh, 100 AFUE Calculations 90 OF 75 OF 15 OF 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17877 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 25093 Btuh Latent Cooling Equipment Load Sizing Structure 2958 Btuh Ducts 2319 Btuh Central vent (0 cfm) 0 Btuh none Equipment latent load 5277 BtUh, Equipment total load' 30370 Btuh Req. total capacity at 0. 70 SHR 3.0 ton Cooling EqujpMent summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A''030 Coil FX4DN(B,F)037 AHRlref 7914585 Efficiency Sensible coolin 12.0 EER, 15 SEER Latent cooling 9 - 24360. Stuh Total cooling10440 Actual air flow 34800 BtUh Airflow factor ' 1160 Btuh Static pressure 0.044 m Load cf sensible heat ratio 0.50 in HBOtuh 0.83 ACCA to meet all require ACM " wrightsoft- •••WrightsoR HI/ACIWYNNE Right -Suite® Universal20.17 17,0.14 RS008101 THE GRAND CARLTON-299.rup Cale = MJ8 Front Door races: N of Manual J 8th Ed. 2017Apr1017.J4:53 page 1 - +- wrightsoft' Right-M Worksheet Job: Entire House Date` QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 FVosed wall 156.2 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heat/cool 4 5 Room dimensions Room area 1473.5 ftz 1.0 x 329.0 ft 329.0 ft' T y Construction U-value Or HTM rea A Area number (Btuh/Wt PF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 ; 13A�oce 1A�lorrr• 9.1. 1.270 rie ne' 4 00 , 35;56: .. 2.55 70.43 .. 479 38 - 442 0 �:1768 1344 1124 2662 ' _ :80 0 80 0 320 204 13A-4ocs 0.143 se 4.00 2.55 128 83 331 210 0 0 0 0 11 1A-clom 1100 1.270 0.390 se se 35.56 10.92 34.77 11.31 24 22 48 22 848 236 829 244 0 0 0 0 0 0 0 0 -W . . VI! t-G MMocs 13A4ocs 0.143 0.143 s sw 4.00 4.00 2.55 2.65 34 360 34 •353 136 1414 86 899 0 224 0 224 .' 0 897 0 570 1A-clom 13A4ocs . Xclom 1.270 0.143. 1.270 sw nw . nw 35.56 4.00 35:56 42.91 2.55 . 45.24 7 290 . - 33 11 .217 0 247 867 1162 298 551 1478 0 112 33 0 79 .0 0 318 1162 0 202 1478 P :C .. 05.20m .. 12C-0sw :16A rrfd :0.770 0.091 0:032 .,nw - - 21.56 2.55 .:0:90, 27.54 1.28 ; 2 32 41 192 1474 . 0 192 , 1474 880 489 ' 1320 1124 246 .. 3419 0 0 . 329 . 0 0 329 . 0 0 295. 0 0 763 F 22A tpl 0.989 - 27.69 0.00 1474 156 4325 0 32.9 52 1440 0 6 c)AED excursion 784 680 Envelope loss/gain 15366 13954 4432 3897 12 a) Infiltration 2822 773 909 249 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 2 460 Applianceslother 2000 0 Subtotal Qines 6 to 13) 18188 17877 5341 4606 Less exdemal load 0 0 0 0 Less transfer 0 0 0 6 Redistribution 0 0 0 0 14 Subtotal 18188 17877 5341 4606 15 Duct loads 31% 48% 5654 8536 31% Q%l 16M 2199 Total room load 23842 26413 T7001 6805 Air required (cfm) 1160 1160 341 299 Calculations approved byACCA to meet all requirements- of Manual J 8th Ed. `A- Wrightsotft' 2017-Apr-10 1 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N + Wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 Exposed wall 0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 ft 5 Room area 63.0 ft2 56.0 ft2 Ty Construction U-value Or HTM Area 2 (ft2) Load number (Btuhlftz.°F) (Btuh/ft2) or perimeter (ft) (Stuh) oorperimeter (ft) (Btuh) Heat Coot Gross WP/S Heat Cool Gross WP/S Heat Cool 6 V►I 1 IA46cs.`: - . 0143 ne', 4.00 2.55 '. 0 0 :. 0 , 0 0 ' 0 ;U 0 t-C 1A-c1om .1.270 , rie: 35:56 70t43 0 0 .. U 0 0 ' ` 0 ,, ;0 0 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 IA-clom 1.270 se 35.56 34.77 0 0 0 0 0 0 0 0 11 11D0 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 W.. 13A-4ocs 0143 s 4.00 Z55 0 0 % 0 0 0 10 0 V�/ 13A4ocs 0.143 sw 4.00 2.55 0 0 0 0 64 57 228 145 --G 1Ao1om 1.270 sw 35.56 42.91 0 0 0 0 7 5 247 298 13AAocs 0.143 nw 4.00 2.55. 0 0 0 0 0 0 0 0 1A clom ; . 1.2.70 .mv 35.56 45.24 0 0 0 .0 .. 0 p : 0 : -o 4A52om - _ 0.770 .nw" . 21.56 27:54 : 0 . 0 . 0 0 . 0 0.'. 0 0 P, 12C-0sw. 0.091 - 2.55 . 1.28 0 0 0 0 0 0 0 0 C M6A30md o:on , - 0:90 . 2.32 63 63 56 :.. 146 ` 56 . ° 56 50 130 F 22p tpl 0.989 - 27.69 0.00 63 0 0 0 56 8 222 0 6 c)AED excursion -2 225 Envelope loss/gain 56 145 747 798 12 a) Infiltration 0 0 140 38 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 0 Subtotal pines 6 to 13) 56 145 887 836 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 145 887 836 15 Ductloads 31% 48% 18 69 31% 48%1 276 399 FTTotal room load 1 7 74 214" 1162 1235 Air required (cfm) 4 9 57 54 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. ,gig& -� wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 2 ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 Front Door faces: N �+ wrightsofN Right-JO Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email: QUICKCALCS ,AOL.COM 1 Room name KrrCHEN BATH 2 =ed wall 0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 192.0 ft 192.0 ft' 9.0 x 5.0 ft 45.0 ftz Ty Construction U-value Or HTM Area (ftj Load Area (ft-) Load number (Btuh/ft'L°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 . !. G MAocs' 16m 13AAocs 0.143 1:27,0 0.143 ne% ne se 4 00. 3556 4.00 2;55 70.43 2.55, . 0 : . 0. 0 0. 0 0 0 0 0 : 0 0 0 40 0 0 40 '• °0 0 : 160 . •,0 0 102 .0. 0 11 ���---DDD_ 1Aclom 11D0 1.270 0.390 se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W� V1/ �--G 13AAo6s 13A-4ocs 0.143: 0.143 s sw 4.00 4.00 2.55 2.55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1Ao1om 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 T;i13A-0ocs ':,4A5-2onn ' 1Aclom: :. 12C-0sw _ 16A30md,' 0.143 1.270 0.770 0.091 0.032. : nw : nw ::nw - ' - 4.00 35.56 21.56 2.55 0.90 2.55 45.24 27.54 1.28 ': 2.32 0 .0 .- 0 64 .: 192 0 0 0 64 _ 192 0 0 0 163 172 0 0 0 82 , 445 0 01 0 0 45 0 0 0 0 45 .0 0 0 0 40 0 . -0 "." 0. 0 :, 104' P F 22A-tp1 0.989 - 27.69 0.00 192 0 0 0 45 5 138 0 Tl 6 c)AED excursion -27 -2 Envelope loss/gain 335 501 339 204 12 a) Infiltration 0 0 87 24 b) Room ventilation 0 0 0 0 13 IntBmal gains: Occupants @ 230 0 0 0 0 Appliances/other 20001 0 Subtotal Qines 6 to 13) 335 2501 426 228 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 .0 14 Subtotal 335 2501 426 228 15 Duct loads 1 31% 48% 104 1194 31% 48%1 133 109 Total room load 439 3695 559 336 Air required (cfm) 21 162 27 15 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- RightSuite@ Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 P A&k . age 3 ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 Front Door faces: N wrilghtsoft° RighW@ Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name BEDROOM 2 ENTRY 2 Exposed wall 32.2 ft 7.0 ft 3 Room height 8.0 It heat/cool 8.0 It heat1cool 4 5 Room dimensions Room area 1.0 x 203.5 ft 203.5 ft2 1.0 x 55.0 ft 55.0 ft2 Ty Construction number U-value (Btuh/ftk°F). Or HTM (Btuhlft2) Area (ft2) or perimeter (ft) Load (Btuh). Area (ft2) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 ,I-4ocs ,. ,1Ac1om 13A4ocs O:A43 1:270 0.143 ne' net se ' 4 00 35.56 4.00 2 55 70.43 2.55 . .. ..128 r` 0 80 128 0 56 513 0 225 326 0 143 - -0, 0' 48 0 ' 0 26 :. 0 106 : ".:0 0 67 11 1Aclom 11DO 1.270 0.390 se se 35.56 10.92 34.77 11.31 24 0 24 0 848 0 829 0 0 22 0 22 0 236 0 244 w y/ Y. G 13A4ocs 13A4ocs 1Aclom 0.143 0.143 1.270 . s sw sw 4.00 4.00 35.56 2.55 2.55 42.91 34 16 0 34 16 0 136 64 0 . 86 41 0 0 8 0 0 8 0 0 32 0 0 20 0 13A46cs 1Aclom. AA5.20m . 12C-0sw .16A 3004 = . 0.143 1.270 0;770 0.091 0 032 -nw - nw nw : - 4:00, 35.56 2f:56 2.55 0.90, 2:55 , 45:24 27.54 , 1.28 . 2.32 0 . 0 0, 0 204 0 0 0 0 204 0 0 0 0 182,.. 0 0 0 0 472 0- 0 72 : •. 55 % 0 0 0. 72 .55 0 0', 0 183 . _ 49 0 : 0 0 92 : • 128 P C F 22A-tpl 0.989 - 27.69 .0.06 204 32 891 0 55 7 _ 194 0 12 a) Infiltration 564 164 122 $4 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 3422 2257 922 579 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3422 2257 922 579 15 Duct loads 1 31% 48-/6l 1064 1078 31%1 489/6 287 276 Total room load 4486 3335 1209 855 Air required (cfm) 218 146 159 38 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A wrightsofY Right-Sufte® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 4 ...Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 Front Door faces: N - wrightsoft°. Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 3* ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 . E)qposed wall 6.0 ft 46.0 ft 3 Room height 8.0 ft heat/cool 8.9 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 488.0 ft 488.0 1t2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2L-OF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 V�! 13A-0ocs .1Aclam :' 0.143 :1':270 ne 65: .; 4:00; - 35.56: ; 2.55 70.43 - 0 0 .0 0 0 0 0 0 231, '- 38 '. - 194 ` 0, = 775 1344 493 ., 2662 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11 1Ac1om 11D0 1.270 0.390 se se 35.56 10.92 34.77 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W, . VI/ �--G .13AAocs, 13AAocs 0.143 0.143 s sw 4.00 4.00 2.55 2.55 0 48 0 48 0 192 .0 12.2 0 0 0 0 0 0 0 0 1A-c1om 1.270 sw 35.56 42.91 0 0 0 0 0 0 0 0 13AA6cs 1q clam . 0.143 1.276 niw :. nw 4:00 35:56 2.55 45.24 0 0 0 0 0 0 0 0 ' 178 0 ' 137 0 5491 0 349 0 4A5-2om . VC-0sw 0.770 0.091 . nw - 21.56 2.55 27.54 1.28 0 56 0 56 0 143 0 72 41 0 0 0 . 880 0 ; 1124 0 P. C. . ;16A 30md 0.032 ' - 090 .: ' 2.32 42 42 38. 97 488 :_ .. 488 _ 437 1132 F 22A tpl 0.989 - 27.69 0.06 42 6 166 0 488 46 1274 . 0 6 c) AED o cursion -3 -56 Envelope loss/gain 539 288 5259 6704 12 a) Infiltration 105 29 895 245 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to.13) 644 317 6154 6409 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 644 3171 6154 6409 15 Duct loads 310 48% 200 151 31% 48% 1913 3060 1 Total room load 844 468 8067 9469 Air required (cfm) 41 21 1 1 .3931 416 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft* 2017-Apr-10 17:14:53 Right -Suite@ Universal 2017 17.0.14 RSU08101 Page 5 ...Wrightsoft WAC\WYNNE-THE GRAND CARLTON-299.rup Cale = MJ8 Front Door faces: N -- wrightsoft� Duct System Sulmmally Date: Entire House By: QUICK CALCS,INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799 Fax 772-466-6796 . Email: QUICKCALCS@AOL.COM r-roject Intormation For: WYNNE DEVELOPMENT THE CARLTON 299, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.284 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 559 27 15 0.376 4.0 Ox 0 VIFx 18.1 115.0 81:1 BEDROOM 2 h 4486 218 146 0.374 6.0 OxO VIFx 18.6 115.0 st1 BEDROOM -A h 3501 170 149 0.297 6.0 Ox0 VIFx 33.1 135.0 st2 BEDROOM-B h 3501 170 149 0.284 6.0 Ox 0 VIFx 41.1 135.0 st2 ENTRY h 1209 59 38 0.510 4.0 OxO VIFx 3.0 95.0 GREAT/DINING c 4735 196 208 0.318 7.0 Ox0 VIFx 22.4 135.0 st2 GREAVDINING-B c 4735 196 208 0.307 7.0 OxO VIFx 28.1 135.0 st2 KITCHEN c 3695 21 162 0.375 7.0 Ox0 VIFx 18.3 115.0 st1 LAUNDRY h 844 41 21 0.366 6.0 Ox 0 VIFx 21.6 115.0 st1 M. BATH h 1162 57 54 0.36..6 4.0 Ox0 VIFx 21.6 115.0 st1 WIC c 214 4 9 0.310 4.0 Ox0 VIFx 26.3 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 737 724 0.284• 689 14.0 0 x 0 VinIFIx st1 st1 Peak AVF 1101 1122 0.284 804 16.0 0 x 0 VinlFlx Wrl hts'oft` 2017-Apr-1017:14:54 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N h Return Branch Detail Table (dame Grille Size (in) Htg (cfm) clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist . Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx .► '�' wrightsoft° RightS2017-Apr-10 17:14:54uite@ Universal 2017 17.0.14 RSU08101 Page 2 �� ...Wrightsoft WACIWYNNE-THE GRAND CARLTON-299.rup Calc = MJ8 Front Door faces: N