Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014 \_I\)\ - 0`9a 3 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION �f Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GEMI% Street: �0 `�� Qif Builder Name: WYNNE BUILDING CORP. Permit Office:. ST. LUCIE COUNTY SCANNED City, State, Zip: FT. PIERCE, FL, Permit Number: BY Owner: Jurisdiction: {} Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate ?ri�`'I'�Ourlty 1. New construction or existing New (From Plans) 9. Wall Types (1806.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1550.30 ft2 b. Frame - Wood, Adjacent R=11.0 256.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 2 d. N/A R= ft2 10. Ceiling Types (1839.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1839.00 ft2 6. Conditioned floor area above grade (ft2) 1839 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151.5 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 185 a. U-Factor: Dbl, U=0.63 151.46 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.056 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems MAR 6i 2018 a. Electric Cap: 40 gallons 8. Floor Types (1839.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.082 Total Proposed Modified Loads: 55.14 PASS Total Baseline Loads: 56.26 I hereby certify that the plans and specifications covered by Review of the plans and 4 ViE ST.gT this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. nn,''�..;; .•;.�•. �, O PREPA DATE: Before. construction is completed this building will be inspected for compliance with Section 553.908 - * k Q V I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. y� COD with WE OWNER/AG NT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory�sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017 ALL PROJECTS require an envelope leakage test report with envelope leakage no greater tfrAkC.4.1.2). 3/5/2018 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 - PROJECT Title- GEMINI Bedrooms: 2 Address Type: Street Address Vuilding Type: User Conditioned Area: 1839 Lot # Owner Name: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 225 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V/ Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1839 14712 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 MASTER BEDROO 256 2048 No 0 1 1 Yes Yes Yes 6 ENTRY* 83 664 No 0 1 Yes Yes Yes 7 LAUNDRY 42 336 No 0 1 Yes Yes Yes 8 GREAT/DINING 568 4544 No 0 1 Yes Yes Yes 9 CLOSET 2 56 448 No 0 1 No Yes Yes 10 BATH 2 48 384 No 0 1 Yes Yes Yes 11 POWDER 42 336 No 0 1 No Yes Yes 12 SITTING ROOM 110 880 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 43 ft 0 343 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 4SIab-On-Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio MASTER BEDRO 51 ft 0 256 ft2 ---- 0 1 0 3/5/2018 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 83 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio GREAT/DINING 39 ft 0 568 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio CLOSET 2 1 ft 0 56 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio BATH 2 8 ft 0 48 ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulatio POWDER 1 ft 0 42 ft2 ---- 0 1 0 12SIab-On-Grade Edge Insulatio SITTING ROOM 22 ft 0 110 ft2 ---- 0 1 0 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or shed Metal 1938 ft2 306 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1839 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic (Vented) MASTER BEDRO 30 Blown 256 ft2 0.1 Wood 6 Under Attic (Vented) `ENTRY 30 Blown 8312 0.1 Wood 7 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 8 Under Attic (Vented) GREAT/DINING 30 Blown 568 ft2 0.1 Wood 9 Under Attic (Vented) CLOSET 2 30 Blown 56 ft2 0.1 Wood 10 Under Attic (Vented) BATH 2 30 Blown 48 ft2 0.1 Wood 11 Under Attic (Vented) POWDER 30 Blown 42 ft2 0.1 Wood 12 Under Attic (Vented) SITTING ROOM 30 Blown 110 ft2 0.1 Wood WALLS Adjacent Space Cavity Width 11 le Ft In Height Ft In Sheathing Framing Area R-Nial-le Enaction Solar Ah,,or Below rrarlp% 1 S=>NE Exterior Concrete Block - Ext InsiflEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.5 0 2 W=>SE Exterior Concrete Block - Ext InsftIEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 _ 3 S=>NE Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 4 N=>SW Exterior Concrete Block - Ext InsMASTER BE 4.1 24 0 8 0 192.0 ft2 0 0 0.5 0 3/5/2018 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 - WALLS -,� Adjacent Ornt In Wall lype SpaceAhc%orn Cavity Width Et Height Sheathing Framing Solar Below 5 E=>NW Exterior Concrete Block - Ext InsMASTER BE 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 6 S=>NE Exterior Concrete Block - Ext IndMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 7 E=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 8 S=>NE Exterior Concrete Block - Ext Insul ENTRY 4.1 , 1 0 8 0 8.0 ft2 0 0 0.5 0 9 S=>NE Exterior Concrete Block - Ext InstIIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 10 N=>SW Exterior Concrete Block - Ext InsGREAT/DINI 4.1 30 0 8 11 267.5 ft2 0 0 0.5 0 _ 11 W=>SE Exterior Concrete Block - Ext Ins8REAT/DINI 4.1 9 0 8 11 80.3 ft2 0 0 0.5 0 _ 12 N=>SW Exterior Concrete Block - Ext Insul BATH 2 4.1 8 0 9 5 75.3 ft2 0 0 0.5 0 _ 13 N=>SW Exterior Concrete Block - Ext InaITTING RO 4.1 10 0 9 5 94.2 ft2. 0 0 0.5 0 14 S=>NE Exterior Concrete Block - Ext InsSITTING RO 4.1 1 0 9 5 9.4 ft2 0 0 0.5 0 15 W=>SE Exterior Concrete Block - Ext InsSITTING RO 4.1 11 0 9 5 103.6 ft2 0 0 0.5 0 16 N=>SW Garage Frame - Wood KITCHEN 11 32 8 256.0 ft2, 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>NW Insulated ENTRY None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W=>SE 2 Metal Low-E Double Yes 0.63 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S=>NE 3 Metal Low-E Double Yes 0.63 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 E=>NW 5 Metal Low-E Double Yes 0.63 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in None None 4 N=>SW 10 Metal Low-E Double Yes 0.63 0.25 36.8 ft2 1 ft 0 in 1 ft 4 in None None 5 W=>SE 11 Metal Low-E Double Yes 0.63 0.25 17.8 ft2 10 ft 0 in 1 ft 4 in None None 6 N=>SW 12 Metal Low-E Double Yes 0.63 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 7 W=>SE 15 Metal Low-E Double Yes 0.63 0.25 18.4 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 320 ft2 320 ft2 32 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1716.4 94.23 177.21 .2598 7 3/5/2018 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts y 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V — Supply — -- Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic - 6 185 ftZ Attic 55 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programabl[e Y Ceiling Fans: v ]Thermostat: Cooling H Jan [] Feb HX Mar Apr Apr I May Jun Jul i May ri Jun rl Jul Aug rl Aug Sep rl S Oct Oct Nov ki Nov Dec H Dec Venting [[ ]] Jan Feb Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/5/2018 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: GEMINI Builder Name: WYNNE BUILDING CORP. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 3/5/2018 11:36 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 ` FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2 7. Windows- Description a. U-Factor: Dbl, U=0.63 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: , FT. PIERCE, FL, New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1550.30 ftz b. Frame - Wood, Adjacent R=11.0 256.00 ft 1 c. N/A R= ft2 2 d. N/A R= ft2 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1839.00 ft2 1839 b. N/A R= ft2 Area c. N/A R= ft2 151.46 ft2 11. Ducts R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 185 ft2 12. Cooling systems kBtu/hr , Efficiency ft2 a. Central Unit 34.8 SEER:15.00 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= ft2 13. Heating systems a. Electric Heat Pump 2.056 ft. 0.250 Area 14. Hot water systems 1839.00 ft2 a. Electric ft2 ft2 b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home:Q�.Ci /FL Zi \ . � t p �i�` kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.95 Pstat THE STgTFo.� QDD *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/5/2018 11:36 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1