HomeMy WebLinkAboutENERGY EFFICIENCY CODE7 SC ANN90 FORM R405-2014 BY FLORIDA ENERGY EFFICIENCY CObEt' I1%b1LDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL , Owner: ': 3 \QlJ C_Q et"N k-QS Permit Number: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1753.0 sqft-) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor: Sgl, U=0.54 111.36 ft2 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1753.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.74 PASS Total Baseline Loads: 53.87 I hereby certify that the plans and specifications covered by Review of the plans and OF 1E SPA F this calculation are in compliance with the Florida Energy specifications covered by this ,y _ Off, Code. calculation indicates compliance with the Florida Energy Code. PREP ARED BY: DATE: i Before construction is completed this building will be inspected for compliance with Section 553.908 ` I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. 0-0 COD WEB OWNER/A N BUILDING OFFICIAL: DATE. DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. py� " l,4 � u v 10/24/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: WYNNE THE WINDSOR Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner: Total Stories: 1 Block/Su bDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes • FLOORS # Floor Type Space Perimeter Perimeter R-Valup Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft2 ---- 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 ---- 0 1 0 10/24/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 • FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 ---- 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 ___- 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft' 0 50 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 ft 0 25 ft2 _--- 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 ---- 0 1 0 12Slab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested . Tested Insul. (deg) 1 Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>W Exterior Concrete Block - Ext InddASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.5 0 2 SW=>E Exterior Concrete Block - Ext InsMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 3 NW=>S Exterior Concrete Block - Ext InMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 4 NE=>W Exterior Concrete Block - Ext Ins)AIASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 10/24/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 -FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space le Et In Et In Area R-Vahle Eraction Ahsor Grarle% 5 NE=>W Exterior Concrete Block - Ext InsuM. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.5 0 6 NE=>W Exterior Concrete Block - Ext InQEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.5 0 7 SW=>E Exterior Concrete Block - Ext InQINING/GRE 4.1 30 0 8 0 240.0 ft2 0 0 0.5 0 8 NW=>S Exterior Concrete Block - Ext InQINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.5 0 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.5 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.5 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.5 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 13 NE=>W Exterior Concrete Block - Ext IndIffDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 14 SW=>E Exterior Concrete Block - Ext InfiffDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 _ 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single Yes 0.54 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.54 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.54 0.25 39.8 ft2 1 ft 0 in 1 ft 4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.55 0.25 40.0 ft2 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.54 0.25 16.2 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2598 7 10/24/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 ,. -FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftZ DUCTS / -- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft2 Attic 95 ftz Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[ ] Heatin[ Jan ] Feb Jan f X] Feb Mar Mar Apr Apr f May X Jun Jul Jul May f Jun �Xj� Au �Xj Au Sep rj Se E Oct Oct Nov X Nov Dec HDec Ventin [ ] Jan [ ] Feb X Mar [X] A r [ Ma [ Jun Jul Aug Se [X Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/24/2017 10:15 AM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRJER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt.insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/24/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 CORM R405-2014 ' - ENERGY PERFORMANCE LEVEL (EPL) • DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. THE WINDSOR, FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- Ext Insul, Exterior R=4.1 1224.00 ftz b. Frame - Wood, Adjacent R=11.0 208.00 ft 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 3 d. N/A R= ftz 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1753.00 ftz 6. Conditioned floor area (ftz) 1753 b. N/A R= ftZ 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Sgl, U, 0.54 111.36 ftz 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ftz 6 325 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 40.00 ftz SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ftz 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.250 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft z a. Electric EF: 0.97 b. N/A R= ftz c. N/A R= ftz b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: \*1cl\11 Address of New Home:wj-s \_Q .-A C �SiS City/FL Zip`%..� %e. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/24/2017 10:15 AM EnergyGauge@ USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 + wrightsoft° 317 ST. LUCIE LN., FT. PIERCE, Project Summary Entire House QUICK CALCS, INC. Phone: 772-466-6799 Fax Email: For: WYNNE DEVELOPMENT THE WINDSOR FT. PIERCE, FL Notes: S Ca 9 S Desi n Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: Date: By: Summer Design Conditions 42 OF Outside db 70 OF Inside.db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatingg Coo" Area (ft2) 1753 17 Volume (ft3) 14741 14741 Air changesthour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow. Airflow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 470F 27 0 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE 90 OF 75 OF 15 OF 50 % 61 gr/lb Sensible Cooling EquipmentLoad Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf load 0.95 sensible 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AAHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow . 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible -heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoftRight- 2017-Apr-10 17:19:28 Suite® Universal 2017 17.0.14 R$U08101 Page 1 'C� ...k CalcsCDocumentslWYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N wriylhtscifr� Right-J® Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/\OL.COM 1 Room name Entire House MASTER BEDROOM 2 Bqposed wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 280.0 ft 5 Room area 1753.0 ft2 280.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhlft2-°F) (BtuWft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 : .13AAocs 0.143 •ne i.4.00' : 2.65 488 448 1795 : 1141 192 .192 769 ' 489 1A-c1om 1.270 ne 35.56 70.43 7 0 247. 488 Of 0. ;0 0 1Ac1om . ' 1.270 sne 35.56 70.43 16 ' 0 581 : 1151 .. 0, 0 0 0 1TAc1om . 1:270 ne. 35.56 45.24 16 . 6 581 739 0. 10.- .0'. 0 11 yJ 13AAocs 0.143 se 4.00 2.65 64 41 165 105 0 0 0 0 -D 11130 0.390 se 10.92 11.31 23 23 248 257 0 0 0 0 13AAocs .. 0.143 ; sw 4:00 2.55 . 437 396 1584 1007 56 56 . 224 :.- 143 ;4A5 tom 0.770 sw: 21;56 27.53 41 45 893 '1140 0 0 . 0 0 13A-4ocs 0.143 nw 4.00 2.55 290 217 867 551 112 79 318 .. 202 IA-c1om 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 4A5-2omd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P 12C-0sw 0.091 .:- 2:55 ; T28 308 - 308 784 395 0-. 0 0 . 0 C 16AS0md 0.032 - 0.90 2.32 1753 1753 1571 4067 280 280 261 650 F` ' , _22A-tpl':' .. 0:989 -: 27:69 . ` 0:00 : 1753:. 153 4237. - 0 .' 280 , .... 45 1246 0 6 c)AED erxursion 1360 600 Envelope loss/gain 15594 15M 39701 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliancestother 1000 0 Subtotal pines 6 to 13) 18467 17655 4779 3789 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 341/o 53% 6190 9340 34% 53% 1602 2005 Total room load 24657 26995 6380 5794 Air required (cfm) 1160 1160 300 249 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .4CC A wrigl7tsoTt' 2017-Apr-10 1 Right-SulteO Universal 2017 17.0.14 RSU08101 Page 1 k Calcs%Documents%WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N wrightsoft°" Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 Exposed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ftz 61.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area number (Btuh/ft2�-°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 613AAocs : 0.143 ; ne " A06 2:55 0 0 0 0 56 49 . - 196. 125 1Ac1om " - 1270 "ne' 35:55 7043:' 0 0 0 _ 0 " 7 0. 24Z 4813. 1Ac16M 1.270 ne 35,56 70.43 0 ": 0 0 0 0 0' 0 0 "W 1Ac1om :; 1.270 . ne 35:56 45 24 0 . 0 0 0 0 0 0:. `0 11 -D 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 . 0 0 1100 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A flocs 0:143 isw 4:00' " .2:55 0 - p p . 0 0 0 " 0 0 �4A5.2om _: 0.776 %sw-" 21A • 27.53 0 0 0" 0 0 D 0! 0 yJ 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770, nw 21.56 36.90 0 0 0. 0 0 0 0 0 P. :12M* 0.091 .- 2 55 1:28 0 0 0 0 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 61 61 55 142 f _ 22A=tpl : 0:989 - 27.69 0.00 63 0 0 : 0 61 7 194 0. 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 56 141 817 764 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 34% 53%01 19 75 34% 53%1 274 404 Total room load 75 216 1091 1168 Air required (cfm) 4 9 51 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. P. wcigF�tsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 2 ..k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N wrilightsoft Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. ay. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name LAUDRY BEDROOM 2 2 3 . E)(posed wall Room height 0 ft 8.0 ft heat/cool 12.0 ft 8.0 ft heat1cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ft2 15.0 x 12.0 ft 180.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btu ft2) Area (ft2) or perimeter (ft) Load (Btuh) (ft2) oorperimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A flocs 1A c1am. 1A-c1om 0.143 1.270 1.270 ne ne. ne 4.00 35:56 35.56. 2.55' 70:43 70.43. 0 0 0 0 0 0 0 0 0 0 0 0 96 0 16 80 = 0 .. .0 319 : 0. '68114 2U3; 0 1151 W 11 1A�1om '. 13AAocs .1.270 0.143 . ne se 35.56 4.00 4524 2.55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11DO 1.3A flocs `. 4A5.2om 13A4ocs 1A-c1om 0.390 0:143 0:770 0.143 1.270 se sw ; sw nw nw 10.92 4.00, 21.56 4.00 35.56 11.31 2.55-. . 27:53 2.55 45.24 0 - :0 : - 0 0 0 0. Q 0 0 0 0 _ 0 0 0 0 0 ;.. 0 0 0 0 0 .. 0 .. 0 0 0 0 ., 0 ` 0 0 0 0 ,0: '.... 0 0 0 0 0 U 0 0 -D VjJ �-C �-G 4A5-2omd 12&0sw 16A-30md 0.770 AM 0.032 nw .- - 21.56 2:55 0.90 36.90 128.. 2.32 0 0 36 0 -0, 36 0 0 32 0 0 84 0 0 180 0 0:: 180 0. 0 161 0 0 418 P C F 22A tptr: 0'98927.69 : 0.001 36 0 0 " 01. 180 12 332 0 61 c)AED excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 10 Subtotal (lines 6 to 13) 32 81 1609 17.72 Less exfemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1015 1786 15 Duct loads 1 34% 53% 13 50 34% 53% 541 945 Total room load 51 145 1 2156 2730 Air required (cfm) 2 6 101 117 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. wrisjhtsoft. 2017-Apr-10 17:19:28 ��A Right -Suite@ Universal 2017 17.0.14 RSU08101 Page 3 ...k CalcslDocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: N -- wrightsoft Right-J® Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS !AOL.COM 1 Room name DINING/GREAT ROOM KITCHEN 2 F�osed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft2 209.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P(S Heat Cool Gross N/P/S Heat Cool 6 0. 143 ne 1.270 ne 35:56 70.43 1A-c1om -. 1.270. 1.270 ne 35.56 7043 70.43 0 0 0 0. 0 . 0 0 0 7`Ac1oms.. ne . 35.56 . 0 0 0 0 .:. 0 0: 0 0 11 Y 13A-toes 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �D 11DO 0.390 . se 10.92 11.31 0 0 0 0 0 0 0 0 ' . 93A flocs DA43 sw 4:00 255 267 226 903 574 : 98 98 392 249 L—G 4A52om 0.770 sw 21.56 : 27.53 : 41' 22 . 893 _: 1140 0 0 0 --:,0' 'L—G 13A4ocs 0.143 nw 4.00 2.55 178 137 549 349 .. 0 0 0 _ 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-29md 0.770 nw 21.56, 36.90 41 0 880 15.05 0 0 0 0 P " "12C Osw: 0;091 ,:- 2:55 ' 128 0 0 0 0 :=; 116 , , 116 ` 295' _ ' 148 C 16A30md 0.032 0.90 2.32 588 588 527 1364 209 : 209 . 187 485 Ftpl; 27:69 .. 0:00 .. 588 50 0 : i 209 ' :'' ; 11, 3Q5 <<'0 6 c)AED exursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a): Infiltration 10001 282 220 62 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13) 6136 6679 1399 . 1880 Less e#emal load 0 0 0 0 Less transfer 0, 0 0 6 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53% 2058 3541 34% 53% 469 995 Total room load 8200 10234 1867 2875 Air required (cfm) 386 440 881, 124 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. .� -d- wrightsoft- 2017-Apr-10 17:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N + wr ghtsoft' Right46 Worksheet Entire House QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL:COM Job: Date: By: 1 Room name BATH HALL 2 F�osed wall 5.0 ft 0 ft 3 Room height 8.0 ft heattcool 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 50.0 ft2 x 5.0 ft 5.0 25.0 ft2 x 5.0 ft Ty Construction number U-value (Btuh/ft'-'F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh orb (ft2) perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 .13A-0ocs 0.143 ne 4.00: 2055. 40 40 160 102 - 0 . 0 0 0 1A-c1om 1 270 ne 35.56 70.43 0 A 0 0 0 :, 0. '0 0. 1Ac1om 1:270 He:35.56 70.43 .0 0 0 0 0 0 , 0 0' 1Ac1om , 1276 ne 35;564 45.24 0. 0 0 - 0 0, 0... -6 VN �p 11 13A4ocs 0.143 se 4.00 2.55 0 0 0 .0. 0 0 0 0 0 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13A flocs :.. 0.1W , sw 4.00; 2 55 0 0 ` .. 0 : 0 . 0 0. '. 0 0 -0 tom ' , :. 0.770 . sw 21.55„ 27..53 0 `_ 0 0 ., 0 _ 0 `. 0 0. 0 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 T-C 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P 12C-0sw. 0:091 - 2.55 1:28 0 0 0 0 0 .0. 0. -0 C 16A30md 0.032 - 0.90 2.32 50 50 45 116 25 25 22 58 %F ::k A tpi A.90 - . 27.69 0.00. 50 5 i 138 : 0 25 ' :0 ' 0 0 6 c)AED woursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 01 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 433 235 22 56 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 34% 53% 147 132 34% 53°/u 0 0 Total room load 686 381 0 0 Air required (cfm) 28 16 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -- wrightsoft• 2017-Ap00 17:19:28 Awk - Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 :k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N wrightsoft° Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM -1 Room name FOYER BEDROOM-3 2 3 4 5 Fgosed wall Room height Room dimensions Room area 9.0 ft 14.0 ft 8.0 ft heat/cool 8.0 ft heat/cool 1.0 x 92.0 ft 13.0 x 13.0 ft 92.0 ftz 169.0 ftz Ty Construction number U-value (Btuh/ftl-°F) Or HTM (Btuh/ftz) Area (ftz) or perimeter (ft) Load Area (ftz) (Btuh) or perimeter (ft) Load (Stuh Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat Cool 6 11 13A-0ocs 1Ac1om ' 1A�1om 1Ac1om 13A4ocs 11DO „ . . + 13A�4ccs. 4A5 tom 13AAocs IA-c1om 4A5-2omd 12C-0sw� 16A 30md 22Atpf` 0.143 1;270 1.270 1:270 0.143 0.390 -0:143 0:770 0.143 1.270 0.770 0.091 0.032 0.989: ne. ne ne :. •ne se . .se sw . sw. nw nw nw . -` - 4.00 35.56 35.56' 35:56' 4.00 10.92 4.00 21.56' 4.00 35:56 21.56, 2.55 0.90 27.69.. . 2.55 70.43 70.43 45-24 2.55 11.31 ' 2:55 : 2753 2.55 45.24 36.90 , .1:28 Z32 0.00 0 -. 0 . 0 0 64 23 8 0 0 0 0 88 92 92 . 0 0 0 0 41 23 8 0 0 0 0 88 92 9 0 0 0 :'. 0 165 248 32 : 0 0 0 0 224 82 249. 0 .. 1.04 0 0 0 0 16 105 0 257 0 : 20 . 8 . 0 0 0 0 0 0 0 0 113 104 213 .169 0 169 SS 0 0 0 0 :8 0 0 0 0 104 169 14. ; 351. 0 581:: 6 0 - 32: 0 0 0 0 265 151 386 223 : 0' a. 739' 0 0 20 0 0 0 0 133 392 . 0 W D V�J �L-_-!G' P' r C rF 6 c)AF_D excursion -25 -52 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 1163 730 2020 . 1527 Less extemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 1163 0 0 730 0 0 2020 0 0 1527 15 Duct loads 1 34% 53% 390 386 341/16 53% 677 808 Total room load Air required (cfm) 1553 73 1116 48 1 -T 2697 127 2335 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. � wrightsof't• 2017-Apr-10 17:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 ...k Calcs\Documents%WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N Duct S stem Summary Job.. - - wrights* y Date: Entire House ft: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AQL.COM ?�'roject Intormation For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in.H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox 0 VIFx 19.5 115.0 st1 BEDROOM 2 C 2730 101 117 0.384 7.0 OxO VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 . 0.353 6.0 Ox0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 Ox 0 VIFx 36.5 135.0 st2 DINING/GREATROOM-B C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox 0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 OxO VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 Ox 0 VIFx 19.9 115.0 SO M. BATH h 1091 51 50 0.282 6.0 Ox 0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 WIC c 216 4 9 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct dame Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 St1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx .� wri htsoftg 2017-Apr-1017:19:29 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...k Calc"s\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox 0 1160 1160. 0 0 0 0 Ox 0 VIFx wri htsoft° 2017-Apr-1017:19:29 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 k Calcs\Documents%WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N