Loading...
HomeMy WebLinkAboutPROJECT INFORMATION+wirlghtsaft- Project Sulmlmary Job: Enure House ISCANNED Date: y e QUICK CALCS,INC. BY St Lucie 10MRAY 317 ST. LUCIE LN., FT. PIERCE, FL 34946. Phone: M-466-6799 Fax 772-466.6796 Email: QUICKCALCS@!AOL.COM. Project• • For., WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatingg Coolin Area (ft2) 1753 1759 Volume (ft3) 14741 14741 Air changefhour 0.38 0.20 Equiv. (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating.output Temperature rise Actual airflow. Airflow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 47OF 27 OF 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE 90 OF 75 OF 15 OF L. 50 % 61 gr/lb Sensible Cooling Equipmentioad Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Bfuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AH R1 ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling. 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual. air flow . 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft" 2017-Apr-1017:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ..k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - wrightsoft^ Right.40 Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat1cool 4 5 Room dimensions Room area 1753.0 ft2 1.0 x 280.0 ft 280.0 ft2 Ty Construction U-value Or HTM Area 2 b (ft2) Load number - (Btuh/ft2°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 VjJ I—D 43A flocs ' 1Ac1om 1Ac1om •'' 1Ac1om " 13A-4ocs 0143 1270 1.270 1.270 0.143 ne tie' ne- ne- se 4.00.2.65. . 35:56 35.56 35.56 4.00 70:43 70.43 45.24 2.55 488 7 . 16 16 64 44t3 ' 0 0 0 41 1795 247 581 581 165 1141 , 488 ; 1151 739 105 - 192 0 0 0 0 192 ' 0. 0 , 0 0 769 0 �0 0 0 489 0 D . U 0 11DO ,.. 13A4ogs. 4A5 tom 0390 0:143 0.770 se ; sw -W . 10.92 4;00 21:56 11.31 2:55 27 53 23 " : .. -437 • 41 23 _.. 396 -' 45, 248 1584 893 257 1007 1190 0 56' 0 0 .56 0 0 224 . 0. 0 143 " 0 Val F— G 13A-4ocs 1Aclom 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 290 33 217 0 867 1162 551 1478 112 33 79 0 318 1162 202 1478 I� .4A5.2omd 12C 0sw 16A-30md 0.770 0.091 0.032 nw ;. -. - 21.56 2:55 0.90 36.90 C28 2.32 41 308 1753 0 308 1753 880 784 1571 1505 ` 395 4067 0 0 280 0 '. 0 280 0 0 251 0 : - 0 650 P. C F 2Z4 tpl '' 0:989 _ . 27.69. 0:00 ; 1753 : 153 : 4237 . " 0 . " 280 45 1246 ,. . ,. 0 6 c)AED moursion 1360 600 Envelope loss/gain 15594 153851 3970 3561 12 a) Infiltration 2873 810 809 226 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 18467 17655 4779 3789 Less exfemal load 0 0 0 0 Less transfer 0, 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 340 53% 6190 9340 34% 53% 1602 2005 Total room load 7— 24657 26995 1 6380 5794 Air required (ofm) 11601 11601 300 249 ._R. ->d- wrightsoft• Right -Suite® Universal 2017 17.0.14 RSUD8101 ..k CalcslDocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: 2017-Apr-10 17:19:28 Page 1 Ir wri htsoft® Ri ht-M Worksheet Job: s 9 Entire House Date:. QUICK CALCS, INCBy: . 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM 1 Room name WIC M. BATH. hwall Oft 7 0 ft 3 Rm height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ft2 61.0 ft2. Ty Construction U-value Or HTM Area Load Area (ft2) Load number (Btuh/ft2-°F) (Btu ft2) or perimeter ft O (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WPM Heat Cool 6 13A�ocs . U.143 ne . 4.06 2.55 0 0 0 :. 0 56 49 . 196 125 1A-clom " 9:270 66 3556 70.43 0 0 U 0 Z '0.: 247 488. 1Ao1om 1;270 ne- 35:56: M.43 0 0` 0 . 0 0 :: 0 0 A 7Ac1om . 1.270 'ne 35.56 45.24 0 . 0 6, 0 0 0 :. 0 0 11 Vy 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 : 0 L--D 11DO 0.390 se 10.92 1131 0 0 0 0 0 0 0 0_ 13A�ocs- 0143 sw 4.00' 2 55 p 0 p p. p 0 ,, p . 0. 0.'" sw/ 21.56 27 53 0 _ 0 0 . - 0 , . p 0 0 r0 13A flocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-o1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0. 0 P 12C 0sw;- 0:0911 ' ',2.55 128 : `0 A ` 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 63 63 56 146 61 61 55 142 F 22A=tpl ` 0 989 27.69 0.00 63 0 :0 ; 0 ' :61, 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration • 0 0 126 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 56 141 817 . 764 Less exiemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 34% 531/o 1 19 75 34% 53% 274 404 Total room load 75 216 1091 1168 Air required (cfm) 4 9 . 51 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2017-Apr-10 17:19:28 A& Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MA Front Door faces: N - - wrightsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 2 Eosed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool - 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ftz 15.0 x 12.0 ft 180.0 ft' Ty Construction U--value Or HTM Area t- Load number (Btuh/ftz'F) (Btuh/ftz) or perimeter (ft) (Btuh) oreaperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6: 11 �!. 13A1locs 1A clorri 1A�1om 1A-clom: 13A-4ocs 0.143 1.270 1.270 .1.270 0.143 ne : ne: . ne . ne se 4:00 3555.6 35i56 35:56 4.00 Z55 70.43 70.43 45.24 2.55 0 0 ; 0 0 0 0 0 0 0 0 0 0. 0 0 0 0 0 0 6 0 96 " 0* 16 0 0 80. 0 " 0 0 0 319 : 0 581 6 0 203 .: 0. 1151 6 0 IL 11130 13A-0ocs 4A5 tom+ : 0.390 0.143 ' 0770 se sw'.: aw 10.92 4i00 21s56 11.31 - 2.55 27:53 0 ;. :0 '. 0 0 0 . 0 0 , 0 0 0 ` 0 0 0 . 0 0 0 ; 0 ' 0 0 _ 0 0 0 0 0 13A4ocs IA-clom 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P C 4A5-2omd 12C 0sw 16A,30md 0.770 0:091 0.032 nw ` - - 21.56 2E55 0.90 36.90 ' 1.28 2.32 0 0 36 0 A 36 0 0 32 0 0 84 0 0 180 0 0 180 0 . " 0 161 0 0 418 0:989 : - 27.69 ' 0.00 36 0 0 ' 0 180, 12 332 ` . U 6 c)AED...!on -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal' 38 95 1615 1786 15 Duct loads 1 34% 53% 13 50 34% 53%1 541 945 Total room load 51 145 2156 2730 Air required (cfm) 2 6 101 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A -�- wrightsoft' RightSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 3 ..k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - wrightsoftRight-M Worksheet Job: Entire House Date: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCSa1l�1OL.COM 1 Room name DINING/GREAT ROOM KITCHEN 2 EVosed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft' 209.0 ft2 Ty Construction U-value Or HTM Area 2) Load (ft-) Load number (Btuh/ft' °F) (Btuh/ft2) or perimeter (ft) (Btuh) oorperimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 0.143 :ne 4.00 - 2.55 0 0 0 0 0: 0 0 0 1Ac1om 1:270 ne 3556 7043 0 0 0 0: 0 0 ;0 0 3A clom 1.270 , ne 35 56 : 70.43 : 0. 0 0. 0 0 0 0' 0 1A�1om . 1:270 ne4 35.56 45;24 .0 0 0 0 0 0 0 0 11 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11DO , 0.390 . se 10.92 11.31 0 0 0 0 0 0 0 0 13A-0ocs 0.143 -.sw 4:00' : -2.55 267 • 226 903 574 98 98 392 249: G. 4A5-2om 0:770 -sw 21:56 ; 27:53 41 22 - 893 - 1140 _ .0 0 0 0 13A4ocs ' 0.143 nw 4.00 2.55 178 137 549 349 0 0 0 0 F-.G tt-1 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 41 0 880. 1505. 0 0 0 0 --(GG` P 'VC-0sw :.. .12 0.00f .- ` 2:55 " 1.28 - 0 , 0- 0 0 ' '116 , . :.116 • ' 295 - - C 16A30md 0.032 - 0.90 2.32 588 588 527 1364 209 209 187 ,148 485 'F 22Akpl`' 0:989 27.69 0.00 588 .. 50 '. 1385 209 6 c)AED excursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a). Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13) 6136 6679 1399 1880 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53% 2058 3541 34% 53% 469 995 FTTotal room load 8200 10234 1867 2875 Air required (cfm) 386 440 86 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �A. -fl- wrightsoft- 2017-Apr-10 1 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 k CaicsIDocuments%WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N -�- wrightsoft' Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-486-6796 Email: QUICKCALCS AOL.COM 1 Room name BATH HALL 2 EVosed wall 5.0 ft 0 ft 3 Room height 8.0 ft heat1cool 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 5.0 ft 50.0 ftz 5.0 x 5.0 ft 25.0 ftz TY Construction number - U-value (Btuhlftz-°F) Or HTM (Btuh/ftz) Area (ftz) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 , 13A-4o6s 1A61om 1Ac1om :; 1Ac1orn 13A-4ocs 0.143 1.270 1.270 1.270 0.143 ne rie .ne se 4 00 35.56: 35.56 35.56 4.00 2,55 70.43 70,43 45.24 2.55 . 40 0 : 0 0. 0 40 0 0 0 0 160 0 0 0 0 . 102 0 0 0. 0 0 0: 0 0 0 .0- 0 0. 0. 0 0 :0. 0 0,.. 0 0 0. 0' 0. 0 N! �p 11DO 13A�ocs 4P&26m :.. 0.390 0:143 0.770 se ; sw : sw 10.92 4:00. 21.56 11.31 2 55 . 27.63 0 0 - 0 0 0 0 0 0 0 0. 0 0 0 0 0 0_ 0 : 0 0 U Q 0 0 • 0 13A4ocs IA-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P.-- C 4A5-2omd 12C-0sw 16A-30md 0..770 0:091 0.032 nw = - 21.56 2.55 0.90 36.90 1:28 2.32 0 0 50 0 . 0 50 0 0 45 0 0 116 0 0- 25 0 0. 25 0 0 22 0 " 0 58 F ,22A-tpl 0.989 - _ 27.69 0.00 50 5 138 0 25' 0 0 0. 6 c)AED excursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 433 235 22 .56 Less extemal load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 34% 63% 147 132 34% 530% 0 0 Total room load 586 381 0 0 Air required (cfm) 28 16 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A " wrightsaft' Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 5 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N wrohtsoft° Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466.6796 Email: QUICKCALCS@,10L.COM 1 Room name FOYER BEDROOM-3 P Exposed wall 9.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area . 1.0 x 92.0 ft 92.0 ftz 13.0 x 13.0 ft 169.0 ftz Ty Construction number U-value (Btuh/ft� °F) Or HTM (Btuh/ftz) Area(ft2) or perimeter (ft) B (tuh) ors perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A flocs 1Ac1om .' 1Ac1om :' 13AAocs 0.143 1:270 1:270 1.270 0.143 ne.. rie°: ne - ne se .4.00 35.56: 35.56 35:56' 4.00 2 55 70 43 70.43.' .4524 2.55 0 0 0 0 64 . 0 0 0 0 41 0 0 0 0 165 0 0 .0 '0 105 104 0 0 16 0 88 ` ` Q 6 0: 0 :, 351 0.1 581:. 0 223 0' 739 0 7.7Aclom T �D 11DO 13A400s:- `4A52om - 0.390 0.143 0:770 .se • sw : aw. 10.92 4.00 21.56 11.31 255 27.53 23 . 8 -- .0 23 8 6 248 32 . 0 257 20 . 0 0 8 0 0 8 .0 0 - 32 U. 0 20 1.0 4 V�/ I-� 13AAocs 1A-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TG 4A5-2omd �.12C-0sw.-. 16A 30md 0.770 0.091 0.032 nw .- - 21.56 2:5.5 0.90 36.90 .1:28 2.32 0 - 88 92 0 98 92 0 224 82 0 113 213 0 104 169 0 . .104 169 0 265 151 0 1M 392 P' C F 2 Xtpl:' 0.989 - 27.69 0.00 : 92 9 240 0: 169 14 304 , 0' 6 c)AED excursion �y _52 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1163 730 2020 1527 Less wdemal load 0 0 .0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1527 15 Duct loads 34% 53% 390 W6 34% WON 6" 808 Total room load 1553 1116 1 2697 2335 Air required (cfm) .73 48 127 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .� _ A.,—wrightsoft• 2017-Apr-1017:19:28 �� Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 ...k CalcslDocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N wrightsoftDuct S stem Summary Job: y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 OxO VIFx 19.5 115.0 st1 BEDROOM 2 C 2730 101 117 0.384 7.0 Ox 0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 . 0.353 6.0 OxO VIFx 26.8 115.0 st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 Ox 0 VIFx 36.5 135.0 st2 DINING/GREATROOM-B C 3411 129 147 0.371 7.0 Ox0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox 0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox0 VIFx 7.0 95.0 KITCHEN C 2875 88 124 0.366 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 Ox 0 VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 1.50 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 wlc c 216 4 9 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Cig Design • Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx wri htsoft• 2017-Apr-1017:19:29 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Cig (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct. Matl . Trunk i rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsofta 2017-Apr-10 17:19:29 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N