HomeMy WebLinkAboutENERGY EFFICIENCY CODEc ,
SCANNED
FORM R405-2014 t
FLORIDA ENERGY EFFICIENCfe6DE MR BUILDING �VS TION
�thod
Florida Department of Business and Professional Reaulatlon Residential PerF '� aTce
St. Lucie UO
Project Name: WYNNE THE ROYALE
Builder Name: WYNNE
Street: WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: 2%, \JQ'C\-2�
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1688.7 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1448.70 ft2
b. Frame - Wood, Adjacent
R=11.0 240.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1720.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1720.00 ft2
6. Conditioned floor area above grade (ft2) 1720
b. N/A
R= ft2
c. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
11. Ducts
R ft2
7. Windows(155.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54 115.42 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.316 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1720.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1720.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 54.94
PASS
Total Baseline Loads: 56.22
1 hereby certify that the plans and specifications covered by
Review of the plans and
TIE ST,q?,
this calculation are in compliance with the Florida Energy
specifications covered by this
_ 0�,
Code.
calculation indicates compliance
with the Florida Energy Code.
/�n►.'"• y;'; ��
PREPA Y:
Before construction is completed
;-;
DATE:
this building will be inspected for
C
compliance with Section 553.908
"'
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
*
with the Florida Energy Code.
C�DyvE'i�
OWNER/ 5 jj��T:
BUILDING
DATE: %
OFFICIAL:
DATE:
- Compliance requires certification by the air handler unit manufant,iro.+am++i,- _;_ t____..
IdULWY-Seama in accordance with R403.2.2.1.
-- - - -•• • cilalosure qualifies as
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakag
test report in accordance with R402.4.1.2.
S
FILL
10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
Page 1 of 5
FORM R405-2014
PROJECT
Title: WYNNE THE ROYALE
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1720
Lot #
Owner:
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE
Rotate Angle: 135
Street:
WYNNE DEV.
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 2 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1720 13760
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 BEDROOM
343 2744 No
0
1
1
Yes
Yes
Yes
2 WIC
63 504 No
0
1
No
Yes
Yes
3 M.BATH
56 448 No
0
1
Yes
Yes
Yes
4 KITCHEN
172 1376 Yes
0
1
No
Yes
Yes
5 BATH
45 360 No
0
1
Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1
Yes
Yes
Yes
7 ENTRY
98 784 No
0
1
Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1
Yes
Yes
Yes
9 GREAT/DINING
528 4224 No
0
1
Yes
Yes
Yes
10 BEDROOM 3
169 1352 No
1
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
343 ftz
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ftz
----
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ftz
----
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
172 ftZ
----
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ftZ
----
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 42.6 ft 0
204 ftZ
----
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 6.3 ft 0
98 ftz
__--
0 1
0
10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
.FORM R405-2014
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
---_
0
1
0
r
9 Slab -On -Grade Edge Insulatio GREAT/DINING 48 ft
0
528 ft2
--__
0
1
0
10SIab-On-Grade Edge Insulatio BEDROOM 3 13 ft
0
169 ft2
____
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Gable or Shed Metal 1813 ft2
286 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
IRCC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
1
Full attic Vented
150
1720 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) BEDROOM
30
Blown
343 ft2
0.1
Wood
2
Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3
Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented) KITCHEN
30
Blown
172 ft2
0.1
Wood
5
Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6
Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7
Under Attic (Vented) ENTRY
30
Blown
98 ft2
0.1
Wood
8
Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9
Under Attic (Vented) GREAT/DINING
30
Blown
528 ft2
0.1
Wood
10
Under Attic (Vented) BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing
Solar
Below
Space
1
N=>SE
Exterior Concrete Block - Ext InsiHEDROOM
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
2
S=>NW
Exterior Concrete Block - Ext InsiSEDROOM
4.1 29
0 8
0
232.0 ft2
0
0
0.5
0
3
W=>NE
Exterior Concrete Block - Ext Insd8EDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
4
S=>NW
Exterior 'Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
5
N=>SE
Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
6
N=>SE
Exterior Concrete Block - Ext In!EffDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
7
NE=>S
Exterior Concrete Block - Ext In&EDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.5
0
8
E=>SW
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 9
0 8
0
72.0 ft2
0
0
0.5
0
9
SE=>W
Exterior Concrete Block - Ext Ind3ffDROOM 2
4.1 2
10 8
0
22.7 ft2
0
0
0.5
0
10
S=>NW
Exterior Concrete Block - Ext InfiffDROOM 2
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
11
NE=>S
Exterior Concrete Block - Ext Insul ENTRY
4.1 1
5 8
0
11.3 ft2
0
0
0.5
0
12
E=>SW
Exterior Concrete Block - Ext Insul ENTRY
4.1 5
0 8
0
40.0 ft2
0
0
0.5
0
10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
�I
,FnRM R4nr,-gf114
WALLS
Adjacent Space Cavity Width
# ()cot In Wall lype13
Height
Sheathing Framing Solar
Below
S=>NW Exterior Concrete Block - Ext Insa AUNDRY 4.1 6 0 8
14 N=>SE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 28 0 8
15 W=>NE Exterior Concrete Block - Ext Ins9REAT/DINT 4.1 20 0 8
16 N=>SE Exterior Concrete Block - Ext InfiffDROOM 3 4.1 13 0 8
17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8
0 48.0 ft2
0 224.0 ft2
0 160.0 ft2
0 104.0 ft2
240.0 ft2
0 0 0.5
0 0 0.5
0 0 0.5
0 0 0.5
0.23 0.5
0
0
0
0
0
DOORS
# Ornt Door Type Space
Storms
U-Value Width Height
Ft In Ft In
Area
1 E=>SW Insulated ENTRY
None
.39 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Ornt ID Frame Panes NFRC
U-Factor SHGC
Overhang
Area Depth Separation Int Shade
Screening
1 W=>NE 3 Metal Low-E Single Yes
2 S=>NW 4 Metal Low-E Single Yes
3 E=>SW 8 Metal Low-E Single Yes
4 N=>SE 14 Metal Low-E Single Yes
5 W=>NE 15 Metal Low-E Single Yes
6 N=>SE 16 Metal Low-E Single Yes
0.54 0.25
0.54 0.25
0.54 0.25
0.54 0.25
0.55 0.25
0.54 0.25
32.4 ft2 1 ft 0 in
6.9 ft2 1 ft 0 in
23.2 ft2 1 ft 0 in
36.8 ft2 1 ft 0 in
40.0 ft2 10 ft 0 in
16.2 ft2 1 ft 0 in
1 ft 4 in Drapes/blinds
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
1 ft 4 in None
Exterior 5
None
None
None
None
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 300 ft2 300 ft2
30 ft
8 ft
11
INFILTRATION
# Scope Method SLA
CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356
1605.3 88.13 165.74 .2598
7
HEATING SYSTEM
# System Type Subtype
Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type Subtype
Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit Split
SEER: 15 34.8 kBtu/hr
cfm 0.85 1
sys#1
10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
._W
.FORM RAnr%-9(114
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.97 40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector
Model
# Area
Volume
FEF
None
None
ftZ
DUCTS
/
— Supply --
— Return --
Air
CFM 25
CFM25
HVAC #
V. #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic
6 325 ftZ
Attic
85 ftZ Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[ ] Jan
He H Jan
[[ ]] Feb
[Xi Feb
Mar
HX Mar
A r
jMa X Jun riJul
l Jun Jul
Aug
Aug
rl
Se
Sep
[ j Oct
)„J OOct
Nov
Nov
Dec
HDecVenting
[ ]Jan
[[ ]] Feb
Mar
Apr
May L Jun Jul
Aug
Sep
l^l
X
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
;.r
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE ROYALE Builder Name: WYNNE
Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 98
The lower the EnergyPerformance Index, the more efficient the home.
WYNNE DEV., FT. PIERCE, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Sgl, U=0.54
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55
SHGC: SHGC=0.25
c. U-Factor: N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
9. Wall Types
Single-family
a. Concrete Block - Ext Insul, Exterior
b. Frame - Wood, Adjacent
1
c. N/A
3
d. N/A
10. Ceiling Types
Yes
a. Under Attic (Vented)
1720
b. N/A
Area
c. N/A
115.42 ft2
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
40.00 ft2
12. Cooling systems
ft2
a. Central Unit
ft2
3.316 ft.
0.250
Insulation Area
R=0.0 1720.00 ft2
R= ft2
R= ft2
13. Heating systems
a. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: (. ,\\rl
Address of New Home��^�q� City/FL Zips
Insulation
Area
R=4.1
1448.70 ft2
R=11.0
240.00 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1720.00 ft2
R=
ft2
R=
ft2
R ft2
6 325
kBtu/hr Efficiency
34.8 SEER:15.00
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10/24/2017 9:20 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1