Loading...
HomeMy WebLinkAboutPROJECT INFORMATION+ wkghtsoft° Project Summary Entire:House QUICK CALCS, INC. SCANNED BY Job: Da St Lucie County By: For. THE-ROYALE WYNNE DEV., FT. PIERCE, FL Notes: �� Q Design Information Weather: Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 19898 Btuh Ducts 6092 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 25990 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heatingg Coolingg. Area (ft2) 1720 1720 Volume (ft3) 14231 14231 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 90 47 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 35 OF Backup: 8.5 HSPF 34600 Btuh @ 47OF 27 OF 1160 cfm 0.045 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible. Cooling Equipment Load Sizing Structure 18607 Btuh Ducts 9204 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 26420 sensible Btuh Latent Cooling Equipment Load Sizing Structure 2182 Btuh Ducts 2516 Btuh Central vent (0 cfm) 0 Btuh (none) . Equipment latent load 4697 Btuh Equipment total load 31117 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh. Actual air flow 1160. cfm. Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Loadsensible heat ratio 0.86 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrightsoft` 2017 Apr-1017:e I Right -Suite® Universal 201717.0.14 RSU08101 Page ..\Quick Caics%DocumentslWYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N wrigntscift Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS .AOL.COM 1 Room name Entire House BEDROOM 2 Biposed wall 180.9 ft 52.0 ft 3 Room height 8.3 ft d 8.0 ft heat/cool 4 5 Room dimensions Room area 1719.5 ft2 1.0 x 343.0 ft 343.0 ftz Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftk"F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 . V{�/-� 13A4ocs 1Ac1om 4A5.2om 0.143 1.270 . 0.770 ` h n' . n .4.00 35:56 21.56 2.55 34.77 19.31 577 16 . 38 524 0 0 2096 565 815 1333 553 .730 72 0 0 72 0. 0 288 0 0 ' 183 0 0 _ G• . 11 W VY 13A4ocs 13A4ocs 0.143 0.143 ne ..a 4,00 4.00.' 2.55 2.55 34 112 34 67 136 269 86 171 0 0 0 0 0 0 0 0 1A c1otn 11D0 • 13A4ocs 13A-0oc5 '._ 1A�1bm,,.. 1.270 O-399 0.143 0:143 1:270 a . ; e se s s -. 35:56 :: 10:9$ 4.00 4:00' 35.56 87.29 91i31 2.55 ; 2.55 . 34.77 24 21: 23 :: 456 `. 7 3 21 23 449 -.14 848 229' 91 179$ `247. . 2082 238 58 :.1143 241 0 •.: 0 0 232 0"-. : 0 - 0 0 232 0 0 0 0 ' : 929 0. 0 . 0; 0 391 0 W V�✓ 13A4ocs 1Ac1om 4A5-2om 0.143 1.270 0.770 w w w 4.00 35.56 21.56 2.55 55.25 45.63 290 33 41 .217 4 4 867 1162 880 551 1806 1862 112 33 0 79 2 0 318 1162 0 202 1806 0 .0;091 -;. 2,55 1i28 224 224. ,571 '. 287 0...: .;•0 ' •''0 : 0. C 16A-30md 0.092 - 0.90 2.32 1720 1720 1541 3989 343 343 307 796 F T. 22l�fpl '. 0:989' -'. 27.69 0.06 1120 181 �5010 0. ::.` 3' „ 52 1446.; '0 6 c)AED exursion 4651 668 Envelope loss/gain 17124 15595 4444 4245 12 a) Infiltration 2774 782 773 218 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 1 230 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 19898 18607 5218 4463 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 19898 18607 5218 4463 15 Duct loads 31% 49% 6092 9204 31% 49% 1598 2208 TTotal room load 1 25990 27810 6815 6671 AIr required (cfm) 11601 1160 304 278 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A wrightsof- Right -Suite® Universal 2017 17.0.14 RSU08101 M17-Apr-10 17::229:34 ...\Quick CalcslDocumentslWYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N Page I d Z 04) ®-A6. �+ � Y �w V RW v t is cn 000000'o'o1�yp• 000000 '- 0�o 00 000�c2 �� �N i33 aq� �� N 000 oo oo oallo�r<.00000 Cal � P rno c� 000c�u� �� p N a0 a1 N � O m O X �CO 0000000,0 �';h,0000(�(+D v a rD 0 0q, co E- 000000008i.0000c8 , O o 00000000000000�'O - "• O M 00 00 M OOOM�j 2a0 U cq p 00000000000000,Oto t� 00 OOOc�` ^cO o .. of = - _ o0000000:000000�0 - o a_ r O O CO M ffDD vC y O O O O O Oo:00M 00000,@ . - ((OO ttOO O _ f Cl) I�C92U-1 M,l�InnU NfO N.MO S (V CI fV N zg•-�z N N C4 fV'.O N sf V'ch0 �•M'a ch NfV,C,V N ccc8mmmyyH333� RL U y •V c E � tyq� N L l 'f.� O iii E a .� Rc �8 $' C?(? I1 E78EEE 8 888 {yp� Q 0 dog 'M'6 To �1I 201 o ma to COO Fla e- N m au) z �- wrightsoft° Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-4663796 Email: QUICKCALCS AOL.COM 1 Room name KrrCHEN BATH . 2 Exposed wall 0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 172.0 ft 172.0 ft' 9.0 x 6.0 ft 45.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area (ft-) Load number (Btuhfft2L-°F) (Btuh/ftz) or. perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross WP/S Heat Cool 6 13AAocs - 1A,c1om 0.143 t270 n n 4.00 35.56 Z55 34.77 0 0 0 0 0 0 0 0 40 0 40 0 166 .0 102 .0 05.2om. 0.770 . n 21.56. 19.31 0 0 0 .0 0 0 0. 0 11 W 13AAocs . 13A-4acs 0.143 0.143 ne a 4.00 4.00 2.55 2:55 0 0 0 0 0 0 0 0 0 0 0 0 0 .0 0 0 1A-cllom -11D0, 13AAoos 1Ac1om.' 1:270 0:300', 0.143 07143 `1-.270- a -e se §> . s 35.56 10.92 4.00 , 4 00 35.56, . 87.29 11.31 2.55 255 3457- 0 .0 0 - 0 0 0 0 0 0 0'- 0 0 0 0 0 0 0 0 0 0 0 0 0 , 0 0` 6 0 0 ` :0 0 0• 0 0 -0. 0 0 0 0 F--G D W �G y✓ I�-CC 13A4ocs 1Ac1om 0.143 1.270 w w 4.00 35.56 2.55 55.25 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 05-2om 0.770 w 21.56 45.63 0 0 0 0 0 0 0 0 P C F 72C 0sw.< : .. 16A30md 22A3p1 0:091 0.032 0989 - .: - ' - .. :25$ 0.90. 27:68 ': 1:28 2.32 0.00 . 64 172 ' 172 :.. 64 172 0. . 763 164 - 0 i' 82 399 0 ' : 0 45 , " 45 : 0 45 5 0 40 : " :136 104 : 0 6 c)AED excursion -176 -16 Envelope loss/gain 317 305 339 190 12 a) Infiltration 0 0 74 21 b) Room ventilation 0 01 0 0 13 internal gains: Occupants @ 230 0 0 b 0 Appliances/other 2000 .0 Subtotal Pines 6 to, 13) 317 2305 413 . 211 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 317 2305 413 211 15 Duct loads 1 31% 49%1 97 1140 31% 49%1 127 104 Total room load I 1 1 414 3446 1 1 540 315 Air required (cfm) 18 144 24 13 Calculations approved byACCA to meet all requirements of Manual J &h Ed. wrightsoft' Right -Suite® Universal 201717.0.14 RSU08101 2017-Apr-101 Page 3 \Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N - - wrightsoftRigl t-lO Worksheet Job: Entire House Date: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@J\OL.COM 1 Room name BEDROOM 2 ENTRY 2 Exposed'wall 42.6 ft 6.3 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room am 1.0 x 204.0 ft 204.0 ft' 1.0 x 97.5 ft 97.5 ftz Ty Construction U-value Or HTM Area (ft� Load Area (ftj Load number (Btuh/ftk-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 1Ac1om 4A5-2om 0.143 1.270 0.770 ' n n n 4.00. 35.56 21.66 2.55 34.77 19.31 112 0 0 112 0 0 448 0 0 285 0 0 0 0 0 0 0 0 0 0 0: 0 0 0 11 W ', 13A4ocs 13A-4ocs !A-c1om• 11p0 13A4ocs 13A-0ocs.:`: 0.143 0.143 1270 '0:390 0.143 '0:143 ne .e :e - _. a- se s r._ 4.00 4.00 35:56: . 10.92 4.00 4;00 2.55 Z55 87.29 11.31 2.55 ` 23 .72 24 ; 0 M - 112 23 48 2 - . 0 23 ' . ' 112. 91 193 848. " . : - •-0 91 448 58 123 2082 0. 58 285 11 40 0 2.1 0 ". :.p 11 19 . 0 21 0 p 45 76 0 :' ''. 229 0 ,0 29 48 A . 238 0 p ���--DDD W V�! t-G :1A�1omc: 1':270 . s 35:56. ,255. 34:77 p . p 0 p p .. .0 0 0 V�✓ 13A-4ocs 1Aclom 4A5-20m 12C-0sw- : 0.143 1.270 0.770 0:091 w w w : _ . 4.00 35.56 21.56 2.55 2.55 55.25 45.63 '` T.28 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . U : 0 0 0 •- 104 0 0 0 . :104 0 0 0 :265. 0 0 0 - ` 133. P C 16A40md 0.032 - 0.96 2.32 204 204 183 473 98 98 87 226 F 22A=tpl 0:989 '. r 27:69 ` . ` 6.00 ' . ' 204 43 .. 1179 0 98 6,'.' 175 : 0 6 c)AED excursion -90 -50 Envelope loss/gain 3481 3273 878 625 12 a)Infiltration 634 179 95 27 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 1 0 0 SubtotalOines 6 to 13) 4115 3452 974 651 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4115 3452 974 651 15 Duct loads 31% 49% 1260 1708 31% 49% 298 322 Total room load 1 5376 5159 1272 974 Air required (cfm) 1 240 215 1 1 57 41 Calculations approved byACCA to meet all requirements of Manual J 8th Ed.. A -' wcightsoft' 2017-Apr-10 1 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N N Z W A W N W W WA WN-� f ��1 CL 3N mi_ wr 9c�D2N40DDOh.DDSnoDi �7 3a vcYnN�. o to .. - wC O cep' `m .. poppopoO;o 0-+ 0AA a0 c0p;+,0p a00-�'oAA - fO�''OO�O.WWOOWWOOW x� Tm CD tl1.,41, m fD. fD m. m VON -N?fn.,A O;N AA >CIIA W' o Poo`�;&�i`dirngrn.g'SN"`digg`�ii�'iS � c�2 v jt7J�. NNI CO o ppN;-+, pNrn�N�NNNN �V?I tNf�-+NV FAyIN O.NONOWNN V�� cn-W-+V � � O � A A (� ..pp NNW OOO O.OD O o 000000� O O .00o 0&000(Do Mao V �� ... .. )t OZ ;:v� rn o VO O� NON0000 O�O OtWD _ p�W.. .: OI WW y� 0000 N.00000000 _ PL m g v g ODO �A000 A 00 OCN7� (WO N O V�NOOO CJN.00.o 00000 O ONO ONO'O.•A+OOVO co O OO OO Foo(O ., - MR AA W ' . m ONo:O NOVOOOC oCoo oo— W Y o ,p t�i17 GO� xa' N ��000 � cp � = ONO OW W t0WC 00�OO.O CC 00'WO� �� pN�pp�� ^C .. - - '• .. C.WO Ot00000000 .O L K .de 0 ID .. - - wriohtsoftRight-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM 1 Room name BEDROOM 3 2 Exposed wall 13.0 ft 3 Room height 8.0 ft heat/cool 4 5 Room dimensions Room area 13.0 x 13.0 ft 169.0 ftz Ty Construction number LI-value (Btuh/ft'L°F). Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross NIP/S Heat Cool 6._ 13AAOCS 0.143 n 4.00 2.55 104 88 353. 224 1A61om 4A5 tom 1.270 0.770 n , n 35:56 21.56. 34.77 19.31 16 .0 0 0 565 0 553 0 ' 11 W 13A-4ocs 13.9ocs 0.143 0:143 ne a 4.00 4.00 2.55 2.55 0 0 0 0 0 0 0 0 AA-.c1om.. 11D0' 13AAocs 13A�ocs< VAc om ' : 13AAocs 1A-clom 4A5-2om 72C419w'-:.,. ; .. .:` 16A30md 1270 0.390 0.143 0143 1:270 0.143 1.270 0.770 ' -0:091': 0.032 a : - e se s:: ". s' w w w -: - 35.56 10:92 4.00 4:00 35 56 4.00 35.56 21.56 2.55. 0.90 87.29 :: 11:31 2.55 2.55 34.77 2.55 55.25 45.63 ' ..1,28: 2.32 0 0 0 : 0 0 0 0 0 0. 169 0 0, 6 0 0 0 0 0 0' 169 0 ' . 0 0 6 0 0 0 0 0;: 151 0 0 0 : 0 . p 6 0 0 0 392 .: w V�/ yJ ,P. C F 2214fp1r ':' : _ 0:989 ' -. 2769 ' 0.00 169 . 13 360 0 6 c)AED excursion -103 Envelope lass/gain 1430 1066 12 a) Infiltration 193 55 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 0 Subtotal pines 6 to 13) 1623 1351 Less edemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 1623 1351 151 Duct loads 31%1 49% 497 668 Total room load 1 2120 2019 Air required (cfm) 1 95 84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �A 4j:1- wcightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N Duct System Summary Job: +�- wrightsoft° y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772466-6799 Fax 772466-6796 Email: QUICKCALCS , OL.COM Project Intormation For: THE ROYALE WYNNE DEV., FT. PIERCE, FL Externalstatic pressure Pressure losses Available static pressure Supply /. return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.286 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.286 in/100ft 1160 cfm 175 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln. (ft) Ftg.Egv Ln (ft) Trunk BATH h 540 24 13 0.351 4.0 Ox 0 VIFx 27.3 115.0 st1 BEDROOM h 3408 152 139 0.286 7.0 Ox0 VIFx 40.1 135.0 st2 BEDROOM 2 h 5376 240 215 0.343 7.0 Ox 0 VIFx 30.8 115.0 st1 BEDROOM 3 h 2120 95 84 0.371 6.0 OxO VIFx 19.9 115.0 st1 BEDROOM -A h 3408 152 139 0.297 7.0 Ox 0 VIFx 33.1 135.0 st2 EIVIRY h 1272 57 41 0.485 4.0 Ox0 VIFx 8.1 95.0 GREAT/DINING-A h 3714 166 163 0.300 7.0 Ox 0 VIFx 31.7 135.0 st2 GREAT/DINING-B h 3714 166 163 0.309 7.0 Ox0 VIFx 27.1 135.0 st2 KITCHEN c 3446 18 144 0.376 7.0 Ox 0 VIFx 18.1 115.0 st1 LAUNDRY h 820 37 18 0.369 4.0 Ox0 VIFx 20.4 115.0 st1 M. BATH h 1131 50 32 0.366 4.0 OxO VIFx 21.6 115.0 st1 wlc c 203 3 8 0.309 4.0 Ox 0 VIFx 26.6 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 639 613 0.286 814 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1103 . 1119 0.286 802 16.0 0 x 0 VinlFlx wri htsoft' 2017-Apr-1017:29:35 1 9 RlghtSuite® Universal 2017 17.0.14 RSU08101 Page 1 ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) . Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 ox0 1160 1160 0 0 0 0 Ox 0 VIFx �. wri htsoft° 2017-Apr-1017:29:35 ti 9 RightSuite® Universal 2017 17.0.14 RSU08101 Page 2 �'� ...\Quick Calcs\Documents\WYNNE-ROYALE-REVISED. nip Calc = MJB Front Door faces: N