HomeMy WebLinkAboutENERGY EFFICIENCY CODEBY -
St Lucie 0601Y
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR
Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: \� Z 5\
Jurisdiction:
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
Design Location: FL, Fort Pierce
1. New construction or existing
New (From Plans)
9. Wall Types a: Concrete(Block 0 Extftnsul, Exterior
Insulation Area
R=4.1 1224.00 ft2
2. Single family or multiple family
Single-family
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
d. N/A
R= ft2
4. Number of Bedrooms
3
10. Ceiling Types (1753.0 sqft.)
Insulation Area
5. Is this a worst case?
Yes
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2)
1753
R= ft2
R= ft2
c. N/A
Conditioned floor area below grade (ft2)
0
11. Ducts
R ft2
7. Windows(151.4 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54
111.36 ft2
SHGC: SHGC=0.25
12. Cooling systems
kBtu/hr Efficiency
b. U-Factor: Sgl, U=0.55
40.00 ft2
a. Central Unit
34.8 SEER:15.00
SHGC: SHGC=0.25
c. U-Factor: N/A
ft2
13. Heating systems
kBtu/hr Efficiency
SHGC:
N/A
ft2
a. Electric Heat Pump
34.8 HSPF:8.50
d. U-Factor:
SHGC:
Area Weighted Average Overhang Depth:
2.850 ft.
14. Hot water systems
Area Weighted Average SHGC:
0.250
a. Electric
Cap: 40 gallons
8. Floor Types (1753.0 sqft.)
Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation
R=0.0 1753.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 53.74
PASS
Glass/Floor Area: 0.086
Total Baseline
Loads: 53.87
I hereby certify that the plans and specifications covered by
this calculation are in compliance vyith the Florida Energy
Code.
PREPARE BY:
DATE:
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
OWNER/ T:
DATE:
Review of the plans and
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
Before construction is completed
this building will be inspected for
compliance with Section 553.908
Florida Statutes.
BUILDING OFFICIAL:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report' in accordance with R402.4.1.2.
•'' 6
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4. Ft�jiliant S�oflw� re Page 1-of 5
'FORM F
4
� \ L
PROJECT
Title:
WYNNE THE WINDSOR
Bedrooms:
3
' Building Type:
User
Conditioned Area:
1753
Owner:
Total Stories:
1
# of Units:
1
Worst Case:
Yes
Builder Name:
WYNNE DEVELOPMENT
Rotate Angle:
225
Permit Office:
ST. LUCIE COUNTY
Cross Ventilation:
No
Jurisdiction:
Whole House Fan:
No
Family Type:
Single-family
New/Existing:
New (From Plans)
Comment:
CLIMATE
Address Type:
Street Address
Lot #
Block/SubDivision:
PlatBook:
Street:
THE WINDSOR
County:
ST. LUCIE COUNTY
City, State, Zip:
FT. PIERCE,
FL,
IECC Design Temp
Int Design Temp
Winter Summer
Heating
Degree Days
Design Daily Temp
Moisture Range
Design Location TMY Site
Zone 97.5 %
2.5 %
FL, Fort Pierce FL VERO_BEACH_MUNI
2 39
90
70
75
299
62
Low
BLOCKS
Number
Name Area Volume
1
Entire House 1753 14024
SPACES
Number
Name Area Volume
Kitchen Occupants
Bedrooms
InfilID Finished
Cooled
Heated
1
MASTER BEDROO 224 1792
No
0
1
1
Yes
Yes
Yes
2
WIC 63 504
No
0
1
No
Yes
Yes
3
MASTER BATH 56 448
No
0
1
Yes
Yes
Yes
4
M.BATH 61 488
No
0
1
Yes
Yes
Yes
5
LAUDRY 36 288
No
0
1
No
Yes
Yes
6
BEDROOM 2 180 1440
No
0
1
1
Yes
Yes
Yes
7
DINING/GREAT R 588 4704
No
2
1
Yes
Yes
Yes
8
KITCHEN 209 1672
Yes
0
1
Yes
Yes
Yes
9
BATH 50 400
No
0
1
Yes
Yes
Yes
10
HALL 25 200
No
0
1
No
Yes
Yes
11
FOYER 92 736
No
0
1
Yes
Yes
Yes
12
BEDROOM 3 169 1352
No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEDRO
37 ft 0
224 ftZ
____
0
1
0
2SIab-On-Grade Edge Insulatio WIC
1 ft 0
63 ftZ
0
1
0
3 Slab -On -Grade Edge Insulatio MASTER BATH
8 ft 0
56 ftZ
____
0
1
0
4 Slab -On -Grade Edge Insulatio M. BATH
7 ft 0
61 ftz
____
0
1
0
5 Slab -On -Grade Edge Insulatio LAUDRY
1 ft 0
36 ft2
____
0
1
0
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
Page 2 of 5
'FORM R405-2014
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
' 6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
----
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft2
----
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft
0
209 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio
HALL 1 ft
0
25 ft2
----
0
1
0
11SIab-On-Grade Edge Insulatio
FOYER 9 ft
0
92 ft2
----
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft2
----
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V # Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 1847 ft2
292 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Belo
10 Wall Type1
Space
w
NE=>W Exterior Concrete Block - Ext InsMWSTER BE
4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
2 SW=>E Exterior Concrete Block - Ext InEMASTER BE
4.1 7
0 8
0
56.0 ft2
0
0
0.5
0
3 NW=>S Exterior Concrete Block - Ext InEMASTER BE
4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
4 NE=>W Exterior Concrete Block - Ext InsMASTER BA
4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
7/6/2017 2:37 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 /
FORM R405-2014
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Belo
w
Space
R--Val-le Et In
Et
In
Area
RAW-
Eractmon
AhSor
5
NE=>W Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8
0
56.0 ft2
0
0
0.5
0
6
NE=>W Exterior
Concrete Block - Ext InEEDROOM 2
4.1 12
0
8
0
96.0 ft2
0
0
0.5
0
7
SW=>E Exterior
Concrete Block - Ext IndWNING/GRE
4.1 30
0
8
0
240.0 ft2
0
0
0.5
0
8
NW=>S Exterior
Concrete Block - Ext IndNNING/GRE
4.1 20
0
8
0
160.0 ft2.
0
0
0.5
0
9
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8
0
88.0 ft2
0
0
0.5
0
10
NE=>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8
0
40.0 ft2
0
0
0.5
0
11
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8
0
64.0 ft2
0
0
0.5
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8
0
8.0 ft2
0
0
0.5
0
13
NE=>W Exterior
Concrete Block - Ext Ind3ffDROOM 3
4.1 13
0
8
0
104.0 ft2
0
0
0.5
0
14
SW=>E Exterior
Concrete Block - Ext InEBffDROOM 3
4.1 1
0
8
0
8.0 ft2
0
0
0.5
0
15
N=>SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.5
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated FOYER
None
.39
3
3
6 8,
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V
# Ornt ID
Frame Panes NFRC U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single Yes
0.54 0.25
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5
Metal Low-E Single Yes
0.54 0.25
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3 NE=>W 6
Metal Low-E Single Yes
0.54 0.25
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4 SW=>E 7
Metal Low-E Single Yes
0.54 0.25
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.55 0.25
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6 NE=>W 13
Metal Low-E Single Yes
0.54 0.25
16.2 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82
168.92
.2598
7
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FnRM R4o5-2n14
'
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
-- Supply ----
--- Return ---
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6 325 ftZ
Attic
95 ftZ Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
Feb Mar
Apr
X Jun X Jul
Au
X Se
Oct
Nov
Dec
HeatinHJan
HFeb f X� Mar
E APr f
jMa
May 4 j Jun 4 Jul
Auf
rl
Sep
Oct
Nov
Dec
H
Ventin
Jan Feb X Mar
[ A r [
Ma [ Jun [ Jul
Aug
L Se
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM 78
78 78
78 78 78
78
78
80
80
80
80
PM 80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78
78
78
78
78
78
78
PM 78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
ENERGY
PERFORMANCE LEVEL
(EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
THE WINDSOR, FT. PIERCE, FL,
1. New construction or existing
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
a. Concrete Block - Ext Insul, Exterior
Single-family
R=4.1
1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0
208.00 ft2
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. Number of Bedrooms
3 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
Yes a. Under Attic (Vented)
R=30.0
1753.00 ft2
6. Conditioned floor area (ft2)
1753 b. N/A
R=
ft2
7. Windows- Description
Area c. N/A
R=
ft22
a. U-Factor: Sgl, U=0.54
111.36 ft2 11. Ducts
a. Sup:. Attic, Ret: Attic, AH: Attic
R ft
6 325
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55
40.00 ft2
SHGC: SHGC=0.25
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2 a. Central Unit
34.8 SEER:15.00
SHGC:
d. U-Factor: N/A
ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC:
a. Electric Heat Pump
34.8
HSPF:8.50
Area Weighted Average Overhang Depth:
2.850 ft.
Area Weighted Average SHGC:
0.250
8. Floor Types Insulation Area 14. Hot water systems
Cap:
40 gallons
a. Electric
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2EF:
0.97
b. N/A R=
ft2
c. N/A R=
ft2 b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date:
Address of New Home: \CIN City/FL Zip
:�>\-kS
Olt
im.
o*6
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
""Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:.
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks. or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
framing shall be sealed.
• Rlm joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditionedspace shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated. and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1