HomeMy WebLinkAboutREVISION 3-27-18OFFICE US
DATE FILE
REVISION ELE:
SCANNED
BY
St Lucie coUiMy
PERMIT # 1712-0732
RECEIPT #
PLANNING & DEVELOPMENT SERVICES RE�E�p
BUILDING & CODE REGULATION DIVISION MAR 7 �01e
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652 permittil? De
(772) 462-1553 • FAX (772) 462-1578 St �uqe Cou t,,
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
I. LOCATI
ADDRESSN/ Mioridd Way
2• DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Changing to Im act Windows and Add in a 6x10 slab off rear of home
3. CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: ST. L.FiICIE COUNTY CERT. #: 8898
BUSINESS NAME: orporation
QUALIFIERS NAME
ADDRESS: NAM:
0 South U wy. ouar-tvz
CITY: L. ucie STATE:
PHONE (DAYTIME): - FAX: 772 78-7 56 ZIP:
4. OWNER/BUILDER INFORMATION:
NAME: Wynne Building Corporation
ADDRESS: out wy. ulte
CITY: .
PHONE: (7721878- 13 STATE: FL ZIP:
5.
ARCHITECT/ENGINEER INFORMATION:
,; t- y of ,f { ) r 3 A • �.,•,
ADDRESS: f
r i• F' 1t .r t'.+ �� I c r i
CITY
�ci;�.i- •e..Y�h.'�F�i�v�=dal" W=
PHONE (DA STATE: FL
Revised 07/22/2014 File Co• / • � 4 f 2Y.N�.�.�sn��C.a4C■
Rm
i, Wr,'
!• N
$ � 1v
t
�o �-Sc- -44 f-
his pirmilt
e A/c-
Ar
-4�
•
or
FORM R 05-2017
FLORdDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Flora i a Department of Business and Professional Regulation - Residential Performance Method
Project Na
e: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street:
THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State,
Zip: FT. PIEJ3CF, FL, e Permit Number:
Owner:
`
\ ` Jurisdiction:
Design Location:
FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 )
1. New construction
or existing New (From Plans)
9. Wall Types (1432.0 sqft.) Insulation Area
2. Single family
or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ftZ
b. Frame - Wood, Adjacent R=11.0 208.00 ftZ
3. Number of
units, if multiple family 1
c. N/A R= ftZ
4. Number of
Bedrooms 3
d. N/A R= ftz
5. Is this a w
rst case? Yes
10. Ceiling Types (1753.0 sqft.) Insulation Area
a. Under Attic (Vented) R=30.0 1753.00 ftZ
6. Conditione
I floor area above grade (ftZ) 1753
b. N/A R= ft2
Conditione
J floor area below grade (ftZ) 0
c. N/A R= ftZ
11. Ducts R ' ftZ
7. Windows(1
1.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic 6 225
a. U-Facto
: Sgl, U=0.63 111.36 ftZ
SHGC:
SHGC=0.25
b. U-Facto
: Sgl, U=0.65 40.00 ftZ
12. Cooling systems kBtu/hr Efficiency
SHGC:
SHGC=0.21
a. Central Unit 34.8 SEER:15.00
c. U-Facto
: N/A ftZ
SHGC:
13. Heating systems kBtu/hr Efficiency
d. U-Facto
: N/A ftZ
a. Electric Heat Pump 34.8 HSPF:8.50
SHGC:
Area Weigl
ted Average Overhang Depth: 2.850 ft.
Area Weigf
ted Average SHGC: 0.239
14. Hot water systems
8. Floor Types
(1753.0 sgft.) Insulation Area
a. Electric Cap: 40 gallons
a. Slab -On -Grade
Edge Insulation R=0.0 1753.00 ftZ
b. Conservation features EF: 0.970
b. N/A
R= ftZ
None
c. N/A
R= ftZ
15. Credits Pstat
Glass/Floor
Total Proposed Modified Loads: 53.83 PASS
Area: 0.086
Total Baseline Loads: 53.85
1 hereby certi�
that the plans and specifications covered by
Review of the plans and 4114E S7,q�,
this calculation
are in compliance with the Florida Energy
specifications covered by this ti�
Code.
calculation indicates compliance
nN
with the Florida Energy Code. n+„�% -;=; •'
PREPARE
Y:
Before construction is completed
DATE:
ui i b in t for
li S c 0
I hereby certify
that this building, as designed, is in complianc
Flo t , e
with the Florida
Energy Code.
' G'OD W16
OWNER/
BUI I L:
DATE:
M vlwuww 92 ei
- Compliance requires certification by the air handler unit manufacturer that t e air ha ler enc osure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
File®py
���.,...
4/16/2018 9:09 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405i2017
PROJECT
Title:
WYNNE THE WINDSOR IM Bedrooms: 3
Address Type:
Street Address
Building Ty
e: User
Conditioned Area: 1753
Lot #
Owner Nam
:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: Yes
PlatBook:
Builder Na
e: WYNNE DEVELOPMENT Rotate Angle: 225
Street:
THE WINDSOR
Permit Offs
: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V
esign Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL,
Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area Volume
1
Entire House
1753 14024
SPACES
Number
Name
Area Volume Kitchen . Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1
MASTER BEDROO
224 1792 No
0
1
1
Yes
Yes
Yes
2
WIC
63 504 No
0
1
No
Yes
Yes
3
MASTER BATH
56 448 No
0
1
Yes
Yes
Yes
4
M. BATH
61 488 No
0
1
Yes
Yes
Yes
5
LAUDRY
36 288 No
0
1
No
Yes
Yes
6
BEDROOM 2
180 1440 No
0
1
1
Yes
Yes
Yes
7
DINING/GREAT R
588 4704 No
2
1
Yes
Yes
Yes
8
KITCHEN
209 1672 Yes
0
1
Yes
Yes
Yes
9
BATH
50 400 No
0
1
Yes
Yes
Yes
10
HALL
25 200 No
0
1
No
Yes
Yes
11
FOYER
92 736 No
0
1
Yes
Yes
Yes
12
BEDROOM 3
169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Ilab-On-Grade
Edge Insulatio
MASTER BEDRO 37 ft 0
224 ft2
____
0 1
0
2 Slab
-On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
-___
0 1
0
3 S
ab-On-Grade Edge Insulatio
MASTER BATH 8 ft 0
56 ft2
_---
0 1
0
4 S
ab-On-Grade Edge Insulatio
M. BATH 7 ft 0
61 ft2
____
0 1
0
5 S
ab-On-Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft2
____
0 1
0
4/16/2018 9:0
PM EnergyGaugeO USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 2 of 5
FORM R405-2017
FLOORS
#1
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6SIab-On-Grade
Edge Insulatio
BEDROOM 2 12 ft 0
180 ft2
----
0
1
0
7
lab-On-Grade Edge Insulatio
DINING/GREAT 50 ft 0
588 ft2
____
0
1
0
8 Slab
-On -Grade Edge Insulatio
KITCHEN 11 ft 0
209 ft2
___-
0
1
0
9 ¢lab
-On -Grade Edge Insulatio
BATH 5 ft 0
50 ft2
----
0
1
0
1
lab -On -Grade Edge Insulatio
HALL 1 ft 0
25 ft2
----
0
1
0
11
lab -On -Grade Edge Insulatio
FOYER 9 ft 0
92 ft2
__--
0
1
0
12Slab-On-Grade
Edge Insulatio
BEDROOM 3 14 ft 0
169 ft2
____
0
1
0
ROOF
/
Roof Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V #
Type Materials Area Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1
Gable or Shed
Metal 1847 ft2 292 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic
Vented 150
1753 ft2
N
N
CEILING
#
Ceiling Type
Space R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented)
MASTER BEDRO 30
Blown
224 ft2
0.1
Wood
2
Under Attic (Vented)
WIC 30
Blown
63 ft2
0.1
Wood
3
Under Attic (Vented)
MASTER BATH 30
Blown
56 ft2
0.1
Wood
4
Under Attic (Vented)
M. BATH 30
Blown
61 ft2
0.1
Wood
5
Under Attic (Vented)
LAUDRY 30
Blown
36 ft2
0.1
Wood
6
Under Attic (Vented)
BEDROOM 2 30
Blown
180 ft2
0.1
Wood
7
Under Attic (Vented)
DINING/GREAT 30
Blown
588 ft2
0.1
Wood
8
Under Attic (Vented)
KITCHEN 30
Blown
209 ft2
0.1
Wood
9
Under Attic (Vented)
BATH 30
Blown
50 ft2
0.1
Wood
10
Under Attic (Vented)
HALL 30
Blown
25 ft2
0.1
Wood
11
Under Attic (Vented)
FOYER 30
Blown
92 ft2
0.1
Wood
12
Under Attic (Vented)
BEDROOM 3 30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
SpaceEt In
Height
Et In
Aren
Sheathing Framing
R-NIallie
Solar
Below
1 NE=>W
Exterior Concrete Block - Ext In9MASTER BE 4.1 16
0 8
0
128.0 ft2
0
0
0.5
0
2 SW=>E
Exterior Concrete Block - Ext InsMASTER BE 4.1 7
0 8
0
56.0 ft2
0
0
0.5
0
3 NW=>S
Exterior Concrete Block - Ext InddWSTER BE 4.1 14
0 8
0
112.0 ft2
0
0
0.5
0
4 NE=>W
Exterior Concrete Block- Ext IndMASTER BA 4.1 8
0 8
0
64.0 ft2
0
0
0.5
0
4/16/2018 9:0S
PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page
3 of 5
FORM R405, 2017
WALLS
Adjacent Space
r)rnt Tn Wall Type
CavRAJaity Width
Height
Sheathing Framing
Solar Below
_ 5
NE=>W Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.5
0
6
NE >W Exterior
I
Concrete Block - Ext InDROOM 2
�
4.1 12
0
8 0
96.0 ft2
0
0
0.5
0
7
SW>E Exterior
Concrete Block - Ext IndbINING/GRE
4.1 30
0
8 0
240.0 ft2
0
0
0.5
0
8
NWI >S Exterior
Concrete Block - Ext InQINING/GRE
4.1 20
0
8 0
160.0 ft2
0
0
0.5
0
_ 9
SWLE Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.5
0
10
NE I>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.5
0
11
SE I>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.5
0
_ 12
SWLE Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
13
NE=�W Exterior
Concrete Block - Ext InREDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.5
0
_ 14
SWrE Exterior
Concrete Block - Ext InMEDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.5
0
15
N=>SW Garage
I
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
�/
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
NI W=>S 3
I
Metal Low-E Single Yes
0.63 0.25
N
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2
E=>W 5
Metal Low-E Single Yes
0.63 0.25
N
6.9 ft2
1 ft 0 in
1 ft 4 in
None
None
3 IV
E=>W 6
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4
W=>E 7
Metal Low-E Single Yes
0.63 0.25
N
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5
W=>S 8
Metal Low-E Single Yes
0.65 0.21
N
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6
E=>W 13
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 WholehousIe
Proposed ACH(50) .000356 1636.1 89.82
168.92
.2698
7
4/16/2018 9:09i PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405; 2017
HEATING SYSTEM
#;
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#I
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 .
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
#1
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Celt
# Company Name
System Model # Collector Model
# Area
Volume
FEF
Nine
None
ft2
DUCTS
/
---- Supply --
---- Return ----
Air
CFM 25 CFM25
HVAC #
V/ #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1
Attic 6 225 ft2
Attic
65 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable
Thermostat: Y
Ceiling Fans:
Coolin
Heating X
Jan Feb ] Mar
Jan Feb f X] Mar
ki
Apr
Apr
Jul
May Jun Jul
Ma rj Jun rl
Au
rl Au
Sep [ ]
il Se (j
Octj
Oct
Nov
X] Nov
[ j Dec
[X] Dec
Ventin [
j Jan Feb Mar
[X
A r [
Ma Jun Jul
Aug
Se [X]
Oct
[X] Nov
j ] Dec
Thermostat Sc
�edule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD)
AM 78
78
78
78 78 78
78
78 80
80
80
80
PM 80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH)
AM 78
78
78
78 78 78
78
78 78
78
78
78
PM 78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD)
AM 66
66
66
66 66 68
68
68 68
68
68
68
PM 68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH)
AM 66
66
66
66 66 68
68
68 68
68
68
68
PM 68
68
68
68 68 68
68
68 68
68
66
66
4/16/2018 9:09IPM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project I ame:
WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street:
THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, Sta e,
Zip: FT. PIERCE, FL, Permit Number:
Owner:
Jurisdiction:
Design LI
cation: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, s
lights
The space between window/doorjambs and framing, and
and doors I
skylights and framing shall be sealed.
Rim joists I
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors I
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space I alls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penet
ations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow caviti s
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Bs.
Recessed lig
ting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and
wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/pho
a box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register{
boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a. In addition, i spection of log walls shall be in accordance with the provisions of ICC-400.
4/16/2018 9:09 M EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R406-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
THE WINDSOR, FT. PIERCE, FL,
1. New constriction or existing
2. Single family or multiple family
3. Number of J nits, if multiple family
4. Number of Bedrooms
5. Is this a wort t case?
6. Conditioned floor area (ft2)
7. Windows" Description
a. U-Factor: Sgl, U=0.63
SHGC:
b. U-Factor:
SHGC:
c. U-Factor:
SHGC:
d. U-Factor:
SHGC:
Area Weight
Area Weight
8. Floor Types
a. Slab -On-(
b. N/A
c. N/A
SHGC=0.25
Sgl, U=0.65
SHGC=0.21
N/A
N/A
Average Overhang Depth:
Average SHGC:
Edge Insulation
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0
208.00 ft2
1
c. N/A
R=
ft2
3
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1753.00 ft2
1753
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
111.36 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 225
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
ft2
13. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
34.8
HSPF:8.50
2.850 ft.
0.239
Insulation
Area
14. Hot water systems
R=0.0
1753.00 ft2EF:
a. Electric
Cap: 40 gallons
0.97
R=
ft2
R=
ft2
b. Conservation features
None
15. Credits
Pstat
I certify that thi home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signat re: Date:
Address of New Home:City/FL Zip
0� ZKE Srq�
COD WE'�4
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsuppo!rt@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/16/2018,9:09 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
�o�
R