HomeMy WebLinkAboutENERGY EFFICIENCY CODEDocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
FORM R405-2020
SCANNED
BY
St Lucie County
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional. Regulation - Residential Performance Method
Project Name: 8207 Fort Walton - 1449 B RHG - N
Builder Name: CENTURY COMPLETE
Street: 8207 Fort Walton
Permit Office: ST LUCIE
City, State, Zip: , FL,
Permit Number:
Owner: CENTURY COMPLETE
Jurisdiction: 661000
Design Location: FL, MELBOURNE_REGIONAL_AP
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type01400.0 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1096.00 ft2
b. Frame - Wood, Adjacent
R=13.0 304.00 ftz
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
11. Ceiling Types (1449.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1449.00 ft2
6. Conditioned floor area above grade (ft2) 1449
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c• NIA
R= 2
7. Windows(105.0 sqft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Main, AH: Main
R ft2
6 567
a.. U-Factor: Dbl, U=0.35 105.00 ft2
SHGC: SHGC=0.29
b. U-Factor: N/A ft2
13. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
22.2 SEER:14.50
c. U-Factor: N/A ft2
SHGC:
Area Weighted Average Overhang Depth: 1.857 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.290
a. Electric Heat Pump
22.2 HSPF:8.20
8. Skylights Area
c. U-Factor:(AVG) N/A ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (1449.0 sqft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 1449.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
16. Credits
Pstat
Glass/Floor Area: 0.072 Total Proposed Modified Loads: 45.39
PASS
Total Baseline Loads: 45.93
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
DATE: 07/29/21
Before construction is completed
this building will be inspected for
compliance with Section 553.908
C
0 a
*- °Ir
I hereby certify that this building, as d ' &jam,compliance
Florida Statutes.
with the Florida Energy Code. ��;�
OWNER/AGENT: G
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4
DocuSign Envelope ID: FOAFBD46-lE81-4B74-9CFF-6A5B81570703
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
8207 Fort Walton - 1449 B R
User
CENTURY COMPLETE
1
CENTURY COMPLETE
ST LUCIE
661000
Detached
New (From Plans)
Bedrooms: 4
Conditioned Area: 1449
Total Stories: 1
Worst Case: No
Rotate Angle: 270
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 8207 Fort Walton
County: St. Lucie
City, State, Zip: ,
FL,
CLIMATE
V Design Location TMY Site
Design Temp
97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, MELBOURNE_REGI FL_MELBOURNE_REGI 45 90
70
75 369 69 Medium
BLOCKS
Number
Name Area
Volume
1
Blockl 1449
11592
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main 1449
11592 Yes 5
4
1 Yes Yes Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 137 ft 0
1449 ft2
0.29 0 0.71
ROOF
V #
Type Materials
Roof Gable Roof
Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1527 ft2 242 ft2 Dark
N
0.3 N 0.3 No 0 18.43
ATTIC
V #
Type Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic Vented 300 1449 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1449 ft2 0.1 Wood
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
WALLS
nrnt
Adjacent Space Cavity Width
InWall Type
Height Sheathing Framing Solar Below
n Area R-N/alue Frintinn Ah u
1
2
3
4
5
N=>W
E=>N
S=>E
W=>S
-SW
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Exterior Concrete Block - Int Insul Main
Garage Frame - Wood Main
_V,pt
4.1 33 0 8
4.1 16 6 8
4.1 50 6 8
4.1 37 0 8
13 38 0 8
0 264.0 ft2 0
0 132.0 ft2 0
0 404.0 ft2 0
0 296.0 ft2 0
0 304.0 ft2 0
0 0.4
0 0.4
0 0.4
0 0.4
0.25 0.4
0
0
0
0
0
DOORS
#
Ornt Door Type Space
Storms
U-Value Width
Ft In
Height
Ft In
Area
1
2
3
E=>N Insulated Main
W=>S Insulated Main
-SW Wood Main
None
None
None
.4 3
.46 2 8
.46 2 8
6 8
6 8
6 8
20 ft2
17.8 ft2
17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 270 degrees).
v
Wall
# Omt ID Frame Panes NFRC
U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1 n=>W 1 Vinyl Low-E Double Yes
2 e=>N 2 Vinyl Low-E Double Yes
3 s=>E 3 Vinyl Low-E Double Yes
4 W=>S 4 Vinyl Low-E Double Yes
0.35 0.29 N
0.35 0.29 N
0.35 0.29 N
0.35 0.29 N
15.0 ft' 1 ft 0 in 1 ft 0 in
30.0 ft' 4 ft 0 in 1 ft 0 in
15.0 ft' 1 ft 0 in 1 ft 0 in
45.0 ft2 1 ft 0 in 1 ft 0 in
Drapes/blinds
Drapes/blinds
Drapes/blinds
Drapes/blinds
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1
418ft2 418ft2
45ft
8ft
1
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50) .000356
1352.4 74.2 139.3 .1372
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.2
22.2 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type Subtype
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/ Split
Singl SEER: 14.522.2 kBtu/hr 666 cfm
0.75 1
sys#1
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
FORM R405-2020 INPUT SUMMARY CHECKLIST RFPf)RT
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Main
0.92 50 gal
70 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
— Supply —
V
--- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1 Attic
6 567 ft2
Main
446 ft2 Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinJan Feb
Mar
Mar
[ ] Apr
[ ] Apr
May [ Jun Jul
May [ Jun JXJJul
Au
AuSep
Se
rl
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
Ventin Jan Feb
X Mar
[X] A r [
l
Ma [ Jun Jul
Aug
Se
[X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH) AM
78
78 78
78 78 78
78
78
78
78
78
78
PM
78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH) AM
66
66 66
66 66 68
68
68
68
68
68
68
PM
68
68 68
68 68 68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft2
0 ft
0.3
Main
7/29/2021 9:23 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 4
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
Florida Building Code, Energy Conservation, 7th Edition (2020)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 8207 Fort Walton Permit Number:
FL,
MANDATORY REQUIREMENTS - See individual code sections for full details.
V,
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory)The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
❑ (Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
SECTION R402 BUILDING THERMAL ENVELOPE
❑ R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
❑ R402.4.1 Building thermal envelopeThe building thermal envelope shall comply with Sections R402.4.1.1 and
R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
❑ R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
❑ R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
❑ R402.4.3 Fenestration air leakage. Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
MANDATORY REQUIREMENTS - (Continued)
❑R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
SECTION R403 SYSTEMS
R403.1 Controls.
❑ R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system,
including the manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise
sealed during the test.
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the entire
system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code. Duct leakage testing is required for Section
R405 compliance where credit is taken for leakage, and a duct air leakage Qn to the outside of less than 0.080 (where Qn =
duct leakage to the outside in cfm per 100 square feet of conditioned floor area tested at 25 Pascals) is indicated in the
compliance report for the proposed design.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105"F (41 "C)
or below 557 (13"C) shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). If heated water circulation systems are
installed, they shall be in accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with
Section R403.5.1.2. Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return pipe shall
❑ be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited. Controls for
circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy. The
controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no
demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems shall
automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the
times when heated water is used in the occupancy.
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
DocuSign Envelope ID: FOAFBD46-1 E81-4B74-9CFF-6A5B81570703
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3'/z inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 600C).
❑ R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
❑ R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
❑ R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
❑ R403.6.1 Whole -house mechanical ventilation system fan efficacy.When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where an air handler that is integral to tested and listed HVAC equipment is used to provide whole -house mechanical
ventilation, the air handler shall be powered by an electronically commutated motor.
❑ R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment.
R408.7.1 Equipment sizing (Mandatory). Heating and cooling equipment shall be sized in accordance with ACCA Manual S based
❑ on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation
methodologies, based on building loads for the directional orientation of the building. The manufacturer and model number of the
outdoor and indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design
conditions described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other
factors that affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical
ventilation such as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have
an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is
installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMU
(CFM)
HRV or ERV
Any
1.2 cfm/watt
Any
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
MANDATORY REQUIREMENTS - (Continued)
❑R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section R403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the Florida Building Code, Energy Conservation —Commercial Provisions in lieu of Section R403.
R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
El the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
❑ R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
❑ R403.11 Portable spas (Mandatory).The energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
❑ R403.13 Dehumidifiers (Mandatory If installed, a dehumidifier shall conform to the following requirements:
1. The minimum rated efficiency of the dehumidifier shall be greater than 1.7 liters/ kWh if the total dehumidifier capacity for the house
is less than 75 pints/day and greater than 2.38 liters/kWh if the total dehumidifier capacity for the house is greater than or equal to 75 pints/day.
2. The dehumidifier shall be controlled by a sensor that is installed in a location where it is exposed to mixed house air.
3. Any dehumidifier unit located in unconditioned space that treats air from conditioned space shall be insulated to a minimum of R-2.
4. Condensate disposal shall be in accordance with Section M1411.3.1 of the Florida Building Code, Residential.
❑ R403.13.1 Ducted dehumidifiers. Ducted dehumidifiers shall, in addition to conforming to the requirements of Section R403.13,
conform to the following requirements:
1. If a ducted dehumidifier is configured with return and supply ducts both connected into the supply side of the cooling system, a backdraft
damper shall be installed in the supply air duct between the dehumidifier inlet and outlet duct.
2. If a ducted dehumidifier is configured with only its supply duct connected into the supply side of the central heating and cooling system,
a backdraft damper shall be installed in the dehumidifier supply duct between the dehumidifier and central supply duct.
3. A ducted dehumidifier shall not be ducted to or from a central ducted cooling system on the return duct side upstream from the
central cooling evaporator coil.
4. Ductwork associated with a dehumidifier located in unconditioned space shall be insulated to a minimum of R-6.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 90 percent of the lamps in permanently installed luminaires shall have an
efficacy of at least 45 lumens -per -watt or shall utilize lamps with an efficacy of not less than 65 lumens -per -watt.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
8207 Fort Walton, , FL,
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1096.00 ft2
b. Frame - Wood, Adjacent
R=13.0
304.00 ft2
3. Number of units, if multiple family
1
c. N/A
R=
ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1449.00 ft2
6. Conditioned floor area (ft2)
1449
b. N/A
R=
ft2
7. Windows" Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.35
105.00 ft2
12. Ducts, location & insulation level
R ft2
a. Sup: Attic, Ret: Main, AH: Main
6 567
SHGC: SHGC=0.29
b. U-Factor: N/A
ft2
SHGC:
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
22.2 SEER:14.50
SHGC:
d. U-Factor: N/A
ft2
SHGC:
14. Heating systems
kBtu/hr
Efficiency
a. Electric Heat Pump
22.2
HSPF:8.20
Area Weighted Average Overhang Depth:
1.857 ft.
Area Weighted Average SHGC:
0.290
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2EF:0.92
a. Electric
Cap: 50 gallons
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1449.00 ft2
Credits (Performance method)
Pstat
b. N/A
R=
ft2
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code �MtVTf6�'tures.
Builder Signature: AU"cPet- Date:
Address of New Home:
City/FL Zip:
1UE S7q
24
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1
ro�
DocuSign Envelope ID: FOAFBD46-1E81-41374-9CFF-6A5681570703
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: 8207 Fort Walton - 1449 B RHG - N Builder Name: CENTURY COMPLETE
Street: 8207 Fort Walton Permit Office: ST LUCIE
City, State, Zip: FL, Permit Number:
Y
U
Owner: CENTURY COMPLETE Jurisdiction: 661000
W
Design Location: FL, MELBOURNE_REGIONAL_AP
x
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Pytpnri behind piping and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire surenkler cover plates and walls or ceeloncis.
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
7/29/2021 9:23 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
DocuSign Envelope ID: FOAFBD46-1E81-4674-9CFF-6A5B81570703
ec Prot Summary Job: 8207 FortWalton-1449 B...
wrightsofto ry Date: 07/23/20
House EV. WW
One Stop Cooling and Heating
7225 Sandscove Court, Winter Padc. FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wwwOneStopCooling.00m License: CAC1817652
-Project• •
For: CENTURY COMPLETE
8207 Fort Walton, FL
Notes:
Design Information
Weather: Melbourne Regional, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 43 OF
Outside db
91
OF
Inside db 68 OF
Inside db
74
OF
Design TD 25 OF
Design TD
17
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/Ib
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 13383 Btuh
Structure
12789
Btuh
Ducts 1296 Btuh
Duds
2698
Btuh
Central vent (0 afm) 0 Btuh
Central vent (0 cfm)
0
Btuh
(none)
(none)
Humidification 0 Btuh
Blower
0
Btuh
Piping 0 Btuh
Equipment load 14678 Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.96
Infiltration
Equipment sensible load
14806
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality Semi -tight
Fireplaces 0
Structure
3664
Btuh
Duds
739
Btuh
Central vent (0 cfm)
0
Btuh
Heating Cooling
(none)
Area (f?) 1422 1422
Equipment latent load
4403
Btuh
Volume (ft) 11378 11378
Air changes/hour 0.31 0.16
Equipment Total Load (Sen+Lat)
19209
Btuh
Equiv AVF (cfm) 59 30
Req. total capacity at 0.75 SHR
1.6
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Make Carrier
Trade
Trade
Model CH14NBO2400GOA0
Cond CH14NBO2400GOA0
AHRI ref 9162301
Coil FB4CNP025L
AHRI ref 9162301
Efficiency 8.2 HSPF
Efficiency 11.5 EER,14.5 SEER
Heating Input
Sensible cooling
16650
Btuh
Heating output 22200 Btuh @ 47°F
Latent cooling
5550
Btuh
Temperature rise 0 OF
Total cooling
22200
Btuh
Actual airflow 0 cfm
Actual airflow
740
cfm
Airflowfactor 0 cfrriBtuh
Airflowfactor
0.048
cimBtuh
Static pressure 0 in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.78
Capacity balance point = 33 OF
Backup:
Input=13 kW, Output=43093 Btuh, 100AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
- - wrig•�tsof` 2021-Jul-29 0921:30
•W .-. -� Right-Suite®Universal 2021 21.0.07 RSU21856 Page 1
ACCA ...alton Ae%8207 Fort Walton -1449 B RHG - N.rut Calc= MJ8 Front Door faces: N
DocuSign Envelope ID: FOAFBD46-1 E81-4B74-9CFF-6A5B81 570703
-�- wrightsoft° Right-J® Worksheet
House
One Stop Cooling and Heating
Job: 8207 Fort Walton -1449 B RH...
Date: 07/23/20
W. WW
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wmv..OneStopCooling.com License: CAC1817652
1
2
3
4
5
Room name
Fposed wall
Room height
Room dimensions
Room area
House
175.0 ft
8.0 ft d
1422.3 ftz
KIT
12.0 ft
8.0 ft heat/ood
16.5 x 12.0 ft
198.0 fF
Ty
Construction
number
U-value
(Btuh&k'F)
Or
HTM
(BtuhiW)
Area (fly
or perimeter (ft)
Load
(Btuh)
Area (M
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
Cool
6
11
1N -.'
13A,46cs -
4A5.2ov
11D0------ - - - -
13AAocs
4A5-2ov
4A5-2ov
-11DO _-� _
13A-4ocs
4A5-2ov --
11D.0___ ______ _
1613-30ad
--0.1.43
0.350
0.390
0.143
0.350
----0.143
0.350
_ 0_390
0.143
0.350
--- 0.091
-_0.390
0.032
' 0
n
n
a
a
s.
s
_ s
w
-. w
_ - -
.-n-
-
- 3.56
8.72
-- --9.71
3.56
8.72
--- 3.56
8.72
9.71..
3.56
8.72
-"2.27
9.71.
0.80
_- 2.8o
10.15
- -132
30
- - _82
0
20
- 292
261
_ 19_5
1385
131
--V 830
392
174
887
131
'- 64-6
_ __ 174
1133
229
304
____ ]57
1088
430
- J652
464
. 214
^ - 696
_ 430
- 413
---J4Q
2469
- - 6
0
0
- ---- 96
0
-� - 0
0
_ _ 0
--- 0
0
- - 0
_ ____-0
198
---- - -6
0
-
-- - 96
0
----i' 0
0
0
- - - -- -0
0
•------ 0
0.
198
-- -- --- 0
0
- -0 0
342
0
-- 0
0
TO
�.-_ 0
0
-' 0'
_ _0
158
-- 0
0
_0
_-- 268
0
- l- 0
0
0
^- 0
0
--- 0
--_-_0.
344
11_pG
1hU
I-G
T-_
-G
_-D
. _-_.7.82
2.80
28.65
2.80
10.31
__.-11.99
2.80
28.65
'-TA
--_7.82
1.74
---20
404
_ _ 15
- 296--
- 45
`18
T 264
15
304
_,_18
1422
_-- - -
389
0
233
40
_ 18
249
0
----- 286
---18
1422
�j
-G
L12Czw---'-----
_-D
C
F. -------
22Acpm---
.. _ 1.180
. -_-
---_29.38,
.-_--_0.00
_ _1422
----- 175
' -- _-_5142
-----_ 0
- _ 198
.----12
---• -353
6
c)AED excursion
0
-64
Envelope losstgain
11774
7685
852
548
12
a) Infiltration
b) Room ventilation
1609
0
554
0
141
0
48
0
13
Internal gains. Occupants@ 230
Applianoe-Bother
5
1150
34001
0
0
1200
Subtotal (lines 6 to 13)
13383
12789
993
1797
14
15
Lessexdemalload
Lesstransfer
Redistribution
Subtotal
Ductloads
10%
21%
0
0
0
13383
1296
0
0
0
12789
2698
10%
21%
0
0
208
1201
116
0
0
226
2023
427
Total room load
Air required (dm)
14678
0
15487
740
1317
0
2449
117
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
- wwlo"tsolFt^ 2021-Jul-29 09:21:30
_��• Right -Suite® Universal 202121.0.07 RSU21856 Page 1
alton Ate\8207 Fort Walton -1449 B RHG - N.rut Calc= MJ8 Front Door faces: N
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
-�+ wrightsoft' Right-JO Worksheet Job:
House Date`
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: vmw0neStopCooling.com License: CAC1817652
8207 Fort Walton -1449 B RH...
07/23/20
WW
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
BED 4
29.5 It
8.0 ft heat/000l
1.0 x 145.5 It
145.5 fF
MBED
27.0 ft
8.0 it heaV000l
14.5 x 12.5 It
181.3 fly
Ty
Construction
number
U-value
(Btuh11F2F)
Or
HTM
(Btu h
Area (W)
or perimeter (ft)
Load
(Btuh)
Area (T)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cod
6
11
-
'13A-4ocs - - -
4A5-2ov
13A-4ocs
4A5-2ov --
13A-as
4A5-2ov
11D0._4-- _
13A4ocs -
4A5-2ov -
,12C-Osw
11Do--- --
16B-30ad
- 0.143
0.350
-----0.390
0.143
0.350
--43
0,1
0.350
0.390
0.143
- 0_350
0.091
-----0.390
0.032
-----+
n
n
- n=
a
a
-s
s
5
w
- w
.-
.-_n.-
T
3.56
8.72
---9,71
3.56
8.72
_ 3.55--
8.72
9.71
-- 3.56
8.72
2.27
---.-9.71.
0.80
-2.80
10.15
- - -77.882
2.80
28.65
2,80
10.31
11.99
2.80
28.65
1.44
- 7.82
1.74
- -- - 96
30
-__ _ _ O
112
0
O -
0
-_-_.0
- 28
0
0
-- 0
146
66
0
--- -
112
0
0.
- 0
0
28
0
0
- ----0
146
. 235
261
- --0
399
0
_ 0
0
_.._ _ 0
- 100
0
- --185
304
. - --0
313
0
0
0
_ 0
78
0
0
- - 0
253
-- 0
0
-- - 0
0
0
116--
15
0
100
0
0
-
181
0
- - - -
0
0
101
.13
_:0
- - 100
0
0
181
0
- = - -
0
0
_--360
131
0
0
--- -0
0
0
_ 282
155
fWf -
-i
W
G
LL--DD_
1qJ
- 356
0
0
144
_0_
280
0
0
315
_-GG
_
C
--
0
- - -
116
----_ 1.180
-- _
,_ _..29.38
----
_ - _0.00
----
_146
-
. -- -_ 30
- --
-----867
--
._ _ -- -0
-.----181
: _. -- 27
_-- -_793_
--- ----- 0-
6
c)AED excursion
-51
42
EnWopelosslgain
1978
1082
1784
989
12
a) Infiltration
b) Room ventilation
346
0
119
0
317
0
109
0
13
Internal gains: Occupants@ 230
Appliances/other
1
230
0
2
460
0
Subtotal (lines 6 to 13)
2324
1431
2101
1558
14
15
Less extemal load
Less transfer
Redistribution
Subtotal
Ductloads
10%
21%
0
0
525
2849
276
0
0
358
1790
378
10%
21%
0
0
0
2101
203 1
0
0
0
1558
329
Total room load
Air required (dm)
3125
0
2168
104
2305
0
1887
90
Calculations approved WACCA to meet all requirements of Manual J 8th Ed.
-4 - wr7ghtsoft^ 2021-Jul-29 09:21:30
�� Right-SuiteeOUniversal 202121.0.07RSU21856 Paget
alton A/e\8207 FortWalton -1449 B RHG - N.rut Calc= W8 Front Door faces: N
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
wrightsoft• Right-M Worksheet
House
One Stop Cooling and Heating
Job: 8207 Fort Walton -1449 B RFL..
Date: 07/23120
7225 Sandscove Court, Wnler Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: vAwvOneStopCooling.com License: CAC1817652
WW
1
2
3
4
5
Room name
E)qxosed wall
Room height
Room dimensions
Room area
0 ft
8.0 ft heaV000l
3.5 x 3.5 ft
12.3 fF
I MBA
6.0 ft
8.0 ft heaVcool
14.5 x 6.0 ft
87.0 T
Ty
Construction
number
U-value
(BhuhAF-°F)
Or
HTM
(BiuhAF)
Area (fF)
or perimeter (ft)
Load
(Btuh)
Area (fF)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
NIPS
Heat
Cool
Gross
N/P/S
Heat
Cod
6
11
-
C
13A-0ocs
4A5-2ov
13AA=
4A5-2ov
-- - -- - -
13A�ocs
4A5-2ov
:11D0
0.143
0.350
0_390
0.143
0.350
- ---
0.143
0.350
0.3.90
n
n
.- n
a
a
-- -
s
s
s__
3.56
8.72
- -9.71
3.56
8.72
------
3.56
8.72
-- . 9.71_
3.56
8.72
-227
- 9.T1:'
0.80
2_30
10.15
. --2.80 7.82
28.65
------
2.80
10.31
. �_11.99
2.80
28.65
- -- .6
0_
- 2
0
--- 0
0.
0
= P
d
0
- - 0___
6
0
---- -
0
0_
-- - 9
0
0
- -- 0
-- -0
12
- 0
0.
- -- 0
6
0
- -- -- -
0
' 0
.-- -- 9
0
_ - 0
0
- - -
10
... 0
0
- - 0
6
0
- - - -
0
0
-- - --p
0
-- 0
0
- -0
21
0
0
-- -0
6 0
0
- --
0
0
- - __2
48
0
0
- - -0
87
0
-
- 0
0
- -- --
0
0
. - - -- 0
48
- _ 0
0
- - _0
B7
0
0
0
- - - -
0
0
-- 0
171
0
0
_ _ _..-0
69
0
6
0
-----
0
D
-- 0
134
!- 0
0
Q -----
151
! D
W
�
- -
---
�j
-G
-__
13A�
4A5-2ov
12C-Osw --- - -- -
11D0- -�_-.-
168-30ad
0.143
0.350
- -- 0.091
- -- 0,390
0.032
_-
w
w
--n.
.
0
0
- 0
__---0
12
q--
L-D
1.44
_._7.82
1.74
C
F---
-22A-cpm- -
--1.180..
- _
...29.38
0.00
----12.--
- .0
___0.
- 0
87
-- 6.
- _-1.76..-
-_0.
6
c)AED excursion
1
11
Envelopeloss(gain
10
21
417
275
12
a) Infiltration
b) Room ventilation
0
0
0
0
70
0
24
0
13
Internal gains: Occupants@ 230
Appliances/other
0
0
0
0
0
0
Subtotal (lines6 to 13)
10
21
487
299
14
15
Less external load
Lesstransfer
Redistribution
Subtotal
Duct loads 1
10%
21%
0
0
-10
0
0
0
0
-21
0
0
10%
21%
0
0
2
489
47
0
0
86
384
81
Total room load
Air required (dm)
0
0
0
0
537
0
465
22
Calculations approved WACCA to meet all reouirements of Manual J 8th Ed.
wrightsoR� 2021-Jul-2909:21:30
- ^ Right -Suite® Universal 2021 21.0.07 RSU21856 Page 3
alton A e\8207 Fort Walton -1449 B RHG - N.rut Calc= NUS Front Door faces: N
DocuSign Envelope ID: FOAFBD46-lE81-4B74-9CFF-6A5B81570703
wrightsoft° Right-M Worksheet
House
One Stop Cooling and Heating
Job: 8207 Fort Walton -1449 B RH...
Date: 07/23/20
By: WIN
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: vww 0neStopCooling.com License: CAC1817652
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
MWIC
4.5 ft
8.0 ft heattcod
4.5 x 9.0 ft
40.5 fP
LAUN
0 ft
8.0 ft heall000l
6.0 x 3.0 It
18.0 fF
Ty
Construction
number
U-value
(fthff-F)
Or
HTM
(B
Area (fF)
or perimeter (ft)
Load
(Btiuh)
Area (fF)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cod
6
11
Val
IL-(p
13A-4ocs
4A5-2ov
11D0_-- --
13A-4ocs
4A5-2ov
13A-4ocs -' - --
4A5-2ov
0.143
0.350
- 0.390
0.143
0.350
- -- - 0.143
0.350
0_390
n
n
n
a
a
s
s
�s
3.56
8.72
---9.71-
3.56
8.72
3.56
8.72
-= 9--T
3.56
8.72
- --
2.27
- - 9.7.1.:__-7.62
0.80
2.80
10.15
- 7.82
2.80
28.65
-- 2.80
10.31
-=11_99
2.80
28.65
- - ---
1.44
1.74
0
0
-- ---0
0
0
- 36
0
- 0
0
- - --- o
0
0
-- 36
0
-- 0
0
- -- - 0
0'
-- ---- o
41
0
0
- ' ---0
0
0
- - 128
0
-. 0
0
0
- - -
0
--0-0
32
- 0
0
- 0
0
0
V 101
0
--
0
----- 0
0
70
- 0
0
---
0
-- - - 0
0
--0
0-----.-0
0
---- --
0
----- 0
18
' - 0
0
- -
0
- --- 0
0
---- D
0
0
.--.. -_-
0
-------0.
18
. - 0
0
0
0
- - 0
0
---0
0
0
-_-.-----
0
-'--
14
0.
0
0
0
- -- U
0
- 0
0
- 0
� 0
--- -0.
31
- ---
1l�
L--G
V,U
--
V41
t-G-G
_11,D0- -- - --
13A�
4A5-2ov
12C-0sw
1613-30ad
-_
0.143
0.350
-
0.091
0.390
0.032
w
w
- -
-
--n-
-
. -..�-�
0
-. 0
- -
0
- - ---0
41
. _
C
F . _ -_
.22A-cpm.- .- -- -
- - -- -1.180
._ -
. _. _ 29.38.
._ _0.00
- - - - -41
- - .-----5
---- --j 32
. ------0
-- _ - 18
--- ---
. -- - - - - 0-
- -- -- -0.
6
c)AED excursion
-0
-18
Envelope loss/gain
293
164
14
13
12
a) Infiltration
b) Room ventilation
53
0
18
0
0
0
0
0
13
Internal gains: Occupants@ 230
Appliances/other
0
0
0
0
0
500
Subtotal (lines6 to 13)
346
183
14
513
14
15
Less exdemalload
Lesstransfer
Redistribution
Subtotal
DUQloads
10%
21%1
0
0
0
346
33
0
0
0
183
39
10%
21%1
0
0
-14
0
0
0
0
-513
0
0
Total room load
Air required (dm)
379
0
221
11
0
0
0
0
Calculations approved NACCA to meet all requirements of Manual J 8th Ed.
�}� wr➢ghtsoiFt^ 2021-Jul-29 0921.30
'4CCA Right-SuiteO Universal 202121.0.07 RSU21856 Page 4
alton Are18207 Fort Walton -1449 B RHG - N.rut Calc= NU8 Front Doorfaces: N
DocuSign Envelope ID: FOAFBD46-1E81-41374-9CFF-6A51381570703
wrightsoft' Right-J® Worksheet
House -
One Stop Cooling and Heating
Job: 8207 Fort Walton -1449 B RH...
Date: 07/23/20
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wmv.OneStopCooling.com License: CAM 817652
WW
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
BA2
0 ft
8.0 ft heat/000l
6.0 x 9.0 It
54.0 fF
BED 2
22.0 ft
8.0 ft heat/cool
1.0 x 135.0 ft
135.0 ft
Ty
Construction
number
U-value
(Btuty 'F)
Or
HTM
(B
Area (ft�
or perimeter (ft)
Load
(Btuh)
Area (fF)
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
Cod
6
11
V�J
IL--pG
13A4ocs
4A5-2ov
11D0 -
13A-4ocs
4A5.2ov
13A-40cs
4A5-2ov
11D0 - -- --
13AAocs
4A5.2ov
11D0- -- ---
16B-30ad
0.143
0.350
- 0.390,
0.143
0.350
0.143
0.350
-- 0.390.
0.143
0.350
-----0.39D
0.032
-�
n
-n
a
a
s_
s
5----
w
w
.._n
.. - 3.56
8.72
-- 9-71
3.56
8.72
3.56
8.72
971
3.56
8.72
2.27
-- -9.71
0.80
2.80
10.15
- 7.82
2.80
28.65
2.80
10.31
` - - -�
0
. -=--�
0
0
0-
0•
0
- -_ 0
-- _. __D
54
-
0
-- -- Q
0
0
0
0
0
- 0
=--- 0
54
-0
0
---- 0
0
0
0
0
- -- 9
0
- - - 0
- --- o
43
- 0
0
- -
0
0
0
0
- -
0
-- - 0
- ---0
94
p
0
-- - 9
0
0
0
0
-- ----Q
88
15
-- - 8B
- - -0
135
p
0
- -0.
0
0
0
0
------0
73
0
- - 88
-- 0
135
-
0
- 0
0
0
0
0
_
- - -�
260
131
- -199
------- 0-
108
- 0
0
- -
0
0
0
0
- -- Q
204
430
- - 127
- --0.
234
- -
W
�
-__-
W
- D
C
-__11.99------=-
2.80
28.65
- 1.44
- 7.32
1.74
m-- _ ._ _ . _
, _ - _ 1.180
.. - _ _
-- ---29.38
_ __ 0.00
. ----- _-54
..-.; 0
- -- _ _ 0
-- _ - - _ 0.
-__-- _135
_ - _ _ 22
- _ -• _ _646
- -- --- -_0.
6
c)AED excursion
-31
197
Envelope losstgain
43
91
1344
1192
12
a) Infiltration
b) Room ventilation
0
0
0
0
129
0
44
0
13
Internal gains. Occupants@ 230
Appliances(other
0
0
0
1
230
0
Subtotal (lines 6 to 13)
43
911
1473
1467
14
15
Less e&mal load
Lesstransfer
Redistribution
Subtotal
Dudloads
10%
21%
0
0
282
325
31
0
0
365
455
96
10%
21%
0
0
166
1640
159
0
0
123
1589
335
Total room load
Airrequired (dm)
357
0
552
26
1798
0
1925
92
Calculations approved NACCA to meet all reouirements of Manual J 8th Ed.
w"Olh s'9 FM- 2021-Jul-2909:21:30
- ^• - -- Right -Suite@ Universal2021 21.0.07 RSU21856 Page 5
..alton AreT207 Fort Walton -1449 B RHG - N.rut Calc= MJ8 Front Door faces: N
DocuSign Envelope ID: FOAFBD46-lEB1-4B74-9CFF-6A5B81570703
wrightsoft• Right-M Worksheet
House
One Stop Cooling and Heating
Job: 8207 Fort Walton -1449 B RH...
Date: 07/23/20
-- Tr�rri
7225 Sandsoove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax. (407) 629 - 9307 Web: www.OneStopCooling.com License: CAM 817652
1
Room name
BED 3
FOY
2
E)posed wall
10.5 ft
31.5 ft
3
Room height
8.0 it heaU000l
8.0 ft heat/ood
4
Roomdimensions
1.0 x 136.5 it
1.0 x 139.8 It
5
Room area
136.5 fF
139.8 f
Ty
Construction
U-value
Or
HTM
Area (fF)
Load
Area (ft�
Load
number
(BtuWF)
(B
or perimeter (it)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cod
I Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cod
6
V�J�(
1 MA:xi
(Y143
n
3.66
' 2.80
- _ -�
- _ -
- --0-
6
- 36
16
57
- 44
4A5-2ov
0.350
n
8.72
10.15
0
0
0:
0
0
0
0
0
I-D
11Do
0.390
n
9.71
_ 7.82
0
._ 0
0
0
20
20
195
1_57
IL-(
13A-4ocs
0.143
a
3.56
_
2.80
_
84
69
246
193
0
0
_
0
0
11
4A5-2ov
0.350
a
8.72
28.65
15
0
131
430
0
0
0
0
w
- -
13A-flocs
-- --
0.143
- -
s
-- - --
3.56
..-- - -
2.80
- - - - -
0
--------
0
----- _
0
--0
- 0
0-
v 0--
0
4A5-2ov
0.350
s
8.72
10.31
0
0
0
0
0
0
0
0
�--G
_' : o..11Do
_� _-0.390
- _ s -
_ _ 7.1
_ __-
_ 0
_.
0
0
V,U
13A-0ocs
0.143
w
--9
3.56
2.80
0
__ --
0
_ _ _0
- -
0
__ _
0
__ _0
--
0
_ _0_
---
0
- ---0
0
--- --�
0
GG
4AS2ov
0.350
8.72
28.65
0
0
0
0
0
0
0
0
--
R
-- - - - - --
12C-0sw
- - -
0.091
_w
-
.... _. , .
2.27
_- -
1.44
- -
0
--- -
0
- - -- -
0
- --
0
- -- -
216
- --
198
-- ---
449
286
-D..11D0.
--- - - =
-----0.390
:n--
----- 9.71
---7.82
-- 0
--- 0
- -- -0
-- --- p
-- -
--174.
140-
C
16B-30ad
0.032
-
0.80
1.74
137
137
109
237
---18
140
----18
140
111
-- -
243
-F-. .---22A-cpm----_-
_ __ _
. _ _ 1.180
-- _-.29.38
--_0.00
--- _-- 137.
------___11
_ 309
---- ._0.-_
--.-140
.___-- 32.
_ .. _ 926..
6
c)AED excursion
111
-48
Envelope lossigain
794
970
1911
822
12
a) Infiltration
123
42
53
18
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
1
230
0
0
Appliances/other
300
500
Subtotal (lines 6 to 13)
917
1543
1964
1340
Less erdemalload
0
0
0
0
14
Lesstransfer
Redistribution
Subtotal
0
799
1716
0
546
2088
0
-1964
0
0
-1340
0
151
Dudloads I
10%
21%1
166
441
10%
21%
0
0
Total room load
1882
2529
0
0
Air required (dm)
0
121
1
10
0
Calculations approved NACCA to meet all reouirements of Manual J 8th Ed
i9CC-r�.f !=12 sort^ 2021-Jul-290921:30
F. -� -� Right-Suite®Universal2021 21.0.07 RSU21856 Page 6
alton Are\8207 Fort Walton -1449 B RHG - N.rut Calc= MJ8 Front Door faces: N
DocuSign Envelope ID: FOAFBD46-lE81-4B74-9CFF-6A5B81570703
wrightsof-t Right-J® Worksheet
House
One Stop Cooling and Heating
Job: 8207 Fort Walton -1449 B RH...
Date: 07/23/20
7225 Sandsoove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: vwuwOneStopCooling.com License: CAC1817652
WW
1
2
3
4
5
Room name
Exposedwall
Room height
Room dimensions
Room area
LIV
32.0 ft
8.0 ft heaVcool
1.0 x 274.5 ft
274.5 fF
Ty
Construction
number
U-value
(BtuhAt�-"F)
Or
HTM
(Btu
Area (fly
or perimeter (ft)
Load
(Btuh)
Area
or perimeter
Load
Heat
Cod
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cod
6
11
---- --
13A�ocs ---- - _-
4A5-2ov
11 D0 - _ _ _-- •- _---
13A-4ocs
4A5-2ov
13; �466 -� .
4A5 2ov
13A-4as
4A5.2ov y- -
12C-Osw
------
16B-30ad
- -
- -0.143
0.350
'----_0.390
0.143
0.350
- - 0.143
0.350
0.143
0.350
- -. -.
0.091
---0.390-n_--.9.71.---7.82
0.032
-
n
n
, __rn_
a
- —
3.56
8.72
-- _9.71
3.56
- ---
2.80
10.15.
_ 7.82
2.80
28.65
- - -
0
0
0
112
0
- -- _
0
0
0
112
0
. " - 96
26
-- 18
0
0
- -- -
0
- --0
275
� _- -- - i)
0.
399
0
- _- - 342
_ 261
174
- - 0
0
- -- -
0
----0
219
-- - 'd
0
_0
313
0
-_ -269
309
214
-� 0
-- - - 0
0
-- 0
477
- - - -
"
------
- -- - -
- --
-- - - ---
--- --
- - - -
---
- ---- -
-
-- -
- -- -,
- -- --
- - - -- -
- --
------
-- --
W
�
' G
_ _e
s.
s
w
w
-
-
_8.72
— Y96
8.72
9.7
- 2.80
10.31
. _! 11.99
2.80
28.65
. --. -
1.44
1.74
144
30
_ _A_. _ 18
0
0
. -_ _.-
0
—0
275
W ,
3.56
8.72
_—_G-
R
------
2.27
0.80
:-D..11D0-
C
F_ ---12Amcpm__----.__--_,...
1.180_�_.
29.38.0.00.--____275.__...32.----9.40--
-0.----.-------.--_----
6
c)AED excursion
-64
Envelope loss/gain
2335
1518
12
a) Infiltration
b) Room ventilation
376
0
129
0
13
Intemalgains: Occupants@ 230
Applianceslother
0
0
900
Subtotal (lines 6 to 13)
2711
2547
14
15 1
Less extemal load
Lesstransfer
Redistributon
Subtotal
Ductloads 1
10%
21%
0
0
5
2716
263
0
0
171
2718
573
Total room load
Air required (clm)
2978
0
3292
157
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2021-Jul-2909:21:30
Aft •-•1• - Right- G - N. ut Universal W 1 2 ront orface 56 Page 7
alton N08207 Fort Walton -1449 B RHG - N.rut Calc= MJ8 Front Doorfaces: N
DocuSign Envelope ID: FOAFBD46-1E81-4B749CFF-6A5B81570703
Duct System Summary Job: 8207 Fort Walton -1449 13
wrightsoft° Date: 07/23/20
House By: WW
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: www.OneStopCooling.com License: CAC1817652
For. CENTURY COMPLETE
8207 Fort Walton, FL
Heating
Cooling
External static pressure
0 in H2O
0.50 in H2O
Pressure losses
0.16 in H2O
0.16 in H2O
Available static pressure
-0.2 in H2O
0.34 in H2O
Supply/ return available pressure
-0.080 /-0.080 in H2O
0.170 / 0.170 in H2O
Lowest friction rate
-0.12 in/100ft
0.260 in/100ft
Actual airflow
0 cfm
740 cfm
Total effective length (TEL)
131 ft
Name
Design
(Btuh)
Htg
(clm)
Clg
(cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mati
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BA2
c 552
0
26
0.321
4.0
Ox0
VIFx
10.8
95.0
st2
BED2
c 1925
0
92
0.284
6.0
Ox0
VIFx
24.7
95.0
st1
BEDS
c 2529
0
121
0.294
6.0
Ox0
VIFx
15.7'
100.0
st2
BED4
c 2168
0
104
0.260
6.0
Ox0
VIFx
26.0
105.0
st2
KIT
c 2449
0
117
0.309
6.0
Ox 0
VIFx
15.0
95.0
st2
LIV
c 3292
0
157
0.277
7.0
Ox 0
VIFx
27.5
95.0
st1
MBA
c 465
0
22
0.292
4.0
Ox 0
VIFx
16.4
100.0
st1
MBED
c 1887
0
90
0.303
6.0
Ox 0
VIFx
17.1
95.0
st1
MWC
c 221
0
11
0.302
4.0
Ox0
VIFx
17.7
95.0
st1
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Dud
Name
Type
(Cfm)
(cfm)
FR
(fpm)
(in)
(in)
Material
Trunk
st1
PeakAVF
0
372
0.277
474
12.0
0 x 0
VinlFlx
st2
PeakAVF
0
368
0.260
674
10.0
0 x 0
VinlFlx
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat!
Trunk
rb1
Ox 0
0
740
0
0
0
0
Ox 0
VIFx
- wrightsoft- 2021-,u1-29 0921:30
Right -Suite® Universal 202121.0.07 RSU21856 Page 1
AC0% ...alton Aver8207 Fort Walton -1449 8 RHG - N.rut Calc= MJ8 Front Doorfaces: N
DocuSign Envelope ID: FOAFBD46-1E81-4674-9CFF-6A51381570703
W rlghtsoft° Static Pressure and Friction Rate Job: 8207FortWalton-1449B...
Date: 07/23120
House W. ww
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax: (407) 629 - 9307 Web: wwv.OneStopCooling.com License: CAM 817652
--iL,roject intormation
For: CENTURY COMPLETE
8207 Fort Walton, FL
Available Static Pressure
Heating
Cooling
(in H2O)
(in H2O)
External static pressure
0
0.50
Pressure losses
Coil
0
0
Heat exchanger
0
0
Supply diffusers
0.03
0.03
Return grilles
0.03
0.03
Filter
0.10
0.10
Humidifier
0
0
Balancing damper
0
0
Other device
0
0
Available static pressure
-0.2
0.34
Total Effective Length
Supply Return
(ft) (ft)
Measured length of run -out 18 0
Measured length of trunk 8 0
Equivalent length of fittings 105 0
Total length 131 0
Total effective length 131
Supply Duds
Return Duds
Friction Rate
Heating
(in/100ft)
-0.122 <0.06
-0.122 <0.06
Fitting Equivalent Length Details
Supply 1 1A=20,4X=35,11 G=5, 11 G=5, 1A=35, 11 G=5: TotalEL=105
Return TotalEL=O
Cooling
(in/100ft)
0.260 > 0.18
0.260 > 0.18
.� wri-ghtsoft'°
2021-Jul-29 09:21:30
m Right -Suite® Universal 202121.0.07 RSU21856 Page 1
...alton Are\8207 Fort Walton -1449 B RHG - N.rut Calc= MJ8 Front Doorfaces: N
DocuSign Envelope ID: FOAFBD46-1E81-4B74-9CFF-6A5B81570703
Manual S Compliance Report Job: 8207FortWalton-1449B...
WrlghtSoftg Date: 07/23120
House Br ww
One Stop Cooling and Heating
7225 Sandscove Court, Winter Park, FL 32792 Phone: (407) 629 - 6920 Fax (407) 629 - 9307 Web: wmv.0neStopCooling.mm License: CAC1817652
For: CENTURY COMPLETE
8207 Fort Walton, FL
Cooling Equipment
Design Conditions
Outdoor design DB:
90.6°F
Sensible gain: 15487
Btuh Entering coil DB: 74.0°F
Outdoor design WB:
77.8°F
Latent gain: 4403
Btuh Entering coil WB: 61.7°F
Indoor design DB:
74.0°F
Total gain: 19890
Btuh
Indoor RH:
50%
Estimated airflow: 740
cfrn
Manufacturer's Performance Data
at Actual Design Conditions
Equipmenttype:
SpIitASHP
Manufacturer.
Carrier
Model: CH14NBO2400GOAO+FB4CNP025L
Actual airflow:
740 cfm
Sensible capacity:
16806 Btuh
109% of load
Latent capacity:
4990 Btuh
113% of load
Total capacity:
21796 Btuh
110% of load SHR: 77%
Design Conditions
Outdoor design DB: 43.1 OF Heat loss: 14678 Btuh Entering coil DB: 68.0°F
Indoor design DB: 68.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SpIitASHP
Manufacturer: Carrier Model: CH14NBO2400GOAO+FB4CNP025L
Actual airflow: 0 cfm
Output capacity: 22200 Btuh 151 % of load Capacity balance: 33 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type:
Manufacturer:
Actual airflow:
Output capacity:
Elec strip
Model:
0 cfm
12.6 kW 294% of load Temp. rise: 50 OF
Meets all requirements ofACCA Manual S.
Wr ghtsoft- 2021-Jul-2909:20:57
Right -Suite® Universal 202121.0.07 RSU21856 Page 1
ACCA ...alton AreN8207 FortWalton -1449 B RHG - N.rut Calc= W8 Front Doorfaces: N
DocuSign Envelope ID: FOAFBD46-1 E81 -4B74-9CFF-6A5B81570703
N
199
4" Dryer Duct to Roof KIT
Cap wJDryer Vent Box 11
4" Bath Dud to Roof
W/Fan
Broan 50CFM
I T
Level 1
MWIC
8x4
11 cfm
10x6
10x8 4 SRB 2 i 90 cfm
157 cfm 24 x 4
7"
6"
117 cfm
10x6
121 cfm
BED 24x4
10x6
104 cfm
4
IMI
6 " 6 cfm 10x6
10 " 92 cfm
SRBtON
T 740 cfm
24x14RA
24x4
n W/5KW @240V 1 PH
4 PlenETAL STAND
24x4
FOY
Job #: 8207 Fort Walton -1449 B RHG - N One Stop Cooling and Heating
Performed by WW for:
CENTURY COMPLETE 7225 Sandsoove Court
8207 Fort Walton Winter Park, FL 32792
FL Phone: (407) 629 - 6920 Fax (407) 629 - 9307
www.OneStopCooling.00m
MBED
4" Bath Dud to Roof
W/Fan
Broan50CFM
MBA
BED 2
GAR
A/C-1: 2.0 TON
14.0 SEER H.P.
AC Slab By Builder
2' From Wall
Scale:1 : 98
Page 1
Right Suite Universal 2021
21.0.07 RSU21856
2021-Jul-29 09:22:00
FortWalton -1449 B RHG - N.rut