HomeMy WebLinkAboutTRUSS TOE-NAIL CONNECTIONARROW ON THE TRUSS REPRESENTS ITS LEFT END
TOE -NAIL CONNECTION FROM JACKS TRUSS'S PER MITEK CONNECTION DETAIL
1,324#'s
SCANNED
BY
St Lucie County
�BuRders
FirstSource
1602 INDUSTRIAL PARK DR
PLANT CITY FL
Phone:(813) 759-5922
Fax:(813) 752-1532
http://www.bldr.com
- All "Truss to Wall'
connections are the responsibility of the Building
Designer, not the Truss Manufacturer.
- Dimensions are Feet -Inches- Sixteenths.
- Trusses are to be 24" o.c. unless noted
otherwise (U.N.O.)
- Trusses are not designed to support brick U.N.O.
- Do not cut or modify trusses without first
contacting Builders FirstSource.
- Immediately contact Builders FirstSource if
trusses are damaged.
Connection Notes:
- All hangers are to be Simpson or equivalent
U.N.O.
- Use Manufacturer's specifications for all hanger
connections U.N.O.
- Use 10d x 1 1/2" Nails in hanger connections to
single ply roof girder trusses.
Floor Truss'Notes:
- Shift truss as required to avoid plumbing traps.
- Installation Contractor and/or Field Supervisor
are to verify all dimensions, trap locations, and
options prior to installation
Dimension Notes:
- Drawing not to scale. Do not scale dimensions
ENCLOSED BUILDING
(COND. 1)(CAT. II)
160 MPH
EXPOSURE C
TCLL: 20 PSF
TCDL: 7 PSF
BCLL: 10 PSF
"Non -Concurrent"
BCDL: 10 PSF
DURATION: 1.25
Only reactions greater
than 5,000 Ibs & uplifts
greater than 1,000 Ibs
are noted on the truss
placement page
Century Complete
1449
FBC2020ITP12014
Elevation B
Lot Swing Right
Layout: 1449_B_
Date: 06/07/19
Revision History:
Rev1: 07/19/19
Rev2:
Rev3:
TO SCALE
loft