HomeMy WebLinkAboutPROJECT INFORMATION>r ' - - wrightsoft, Project Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. SCANNED BY Job: St LLACIe COWnty Date: By: 772466-6799 Fax 772-466-6796 Email: For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: � qt Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db. Design .TD Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatingg Cooling Area (ft2) 1753 1753 Volume (ft3) 14741 14741 Air changeWhour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 90 OF 75 OF 15 OF L 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17655 Btuh - Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multi tier Equipment load 0.95 Sensible 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Bfuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 8.5 HSPF Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh 34600 Btuh @ 47°F Latent cooling 10440 Btuh 27 OF Total cooling 34800 Btuh 1160 cfm Actual air flow 1160. cfm 0.047 cfm/Btuh Air flow factor 0.043 cfm/Btuh 0.50 in H2O Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. „ wrightsoft® 2017-Apr-10 17:19:28 Right -Suite® Universal 2017 17.0.14 RSUD8101 Page 1 m ACM ...k CalcslDocuents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N AL Fr wrightso , Right-J® Worksheet Job: Entire House'Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 153.0 ft 45.0 ft -3 Room height 8.4 ft d 8.0 ft heat/cool 4 5 Room dimensions Room area 1753.0 ft2 1.0 x 280.0 ft 280.0 ft2 Ty Construction number U-value Btuh/ft2-°F ( ) Or HTM (Btuhlft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-4ocs 1Ac1om ' 1A-clom 1Ac1om 13A4ocs 0.143'he 1270 1270 1.270 0.143 ne, ne he. se 4.00l.2.65 35.56 35.56 35.56 4.00 70.43: 70.43 45:24 2.55 486 7 16 16 64 448 0 0 0 41 1795 247 581, . 581 165 - 1141 488 1151 739 105 192 : 0 0 : - 0. 0 . 192 0` "0 `0 0 766 ;0 0 ; . 0 0 489 0 0, U 0 yJ �D 11DO 3A4oes 4A5 tom :, 0.390. 0143 0.770 se sw. -sw; 10..92 4:00 2156 11.31 2.55 2753 23 : ; 437 •: 41 23 . 396 45 248 ' 1584 893 257 : 1007 1140 _ 0 56 0 0 56 0 . 0 22 . 4 0 0 "1 0 0 ViJ 13A-40cs IA-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 290 33 217 0 867 1162 551 1478 112 33 79 0 318 1162 202 1478 4A5-2omd J; C-Osw 16A30md 0.770 0.091' 0.032 nw ,. - . - 21.56 2.551 0.90 36.90 1 28 2.32 41 308 1753 0 '.. 308 1753 880 784 1571 1505 395 4067 0 0 280 0 0 280 0 .. 0 251 0 : 0 650 P ; C F ' . ... -22A-tpl 0 989 , - :- 27.69 ." 0.00 > 1753 153 -' 4237 .: 0 . ` 280 45 ..1221 6 c)AED excursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1 1000 0 Subtotal (lines 6 to 13) 18467 17655 4779 3789 Less a denial load 0 0 0 0 Less transfer 0. 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Ductloads 34% 53% 6190 9340 340/o 530/o 16021 2005 Total room load 24657 26995 6380 5794 Air required (cfm) 11601 1160 300 249 AMA -F Wrightsoft' Right -Suite@ Universal 201717.0.14 RSU08101 ... k Calcs\DocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: 2017-Apr-10 17:19:28 Page 1 + - wrightsoftRight.-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46M796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 F�giosed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ft2 61.0 ft2 Ty Construction U-value Or HTM Area (ft Load Area 2 number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A floc's . " 0143 ne , 4;00 2:55 - 0 0 0 0 56 49 196. 125 1Ac1om 1 270 .rie'` 35:Sfi 70?43 0 U 0 0 7. 0 . 247 ' 488' 1A c1om -. 1.270 he 35:56 70.43 0 0 0 0. 0 0 0 0 `.-Ix 6ff ;. 1.270 ne 35.56 45r24 0 . 0 6 0 0 0. 0 . 0 11 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 �-D 11D0 0390 se 10.92 11.31 0 0 0 0 0 0 0, 0. 13A flocs > 0143 - sw 4.00; 255 0 :.. 0 - . 0 . . 0 0 0 ,. 0 0 4A5 tom ..; 0.776 " sw. 21.58 . 27.53 0 0 0, 0 0 p ' 0 0. yJ 13A-4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 I�---GG 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5.2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P ..12C-0siv: 0:091 .- 2.55 1:28 , 0 0' 0 0 0 0. 0 -.0 C 16A 30md 0.032 - 0.90 2,32 63 63 56 146 61 61 55 142 F 22A:tpl.: 0:989 - 27.69 ` 0.00 63 0 0 . 0 :61 . .7 194 : 0. 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pins 6 to 13) 56 141 817 . 764 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 1 34% 53% 19 75 349/6 53% 274 404 Total room load I 75 216 1091 1168 Air required (cfm) 1 14 9 51 50 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page age 2 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - - wrightsofr RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,ACL.COM 1 Room name LAUDRY BEDROOM 2 2 Exposed wall 0 ft 12.0 ft •3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ft2 15.0 x 12.0 ft 180.0 ft' Ty Construction number U-value (Btuh/ft2 °F) Or HTM (Btuh/ftz) Area or perimeter (ft) (Btuh) = orperimeter(ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A4bcs. - 1A c1om :1Ac1om 0.143 1.270 1.270 ne rie:. he . 4.00 35:56 35,56 2.55 70.43 70:43 - 0 0 : 0 0 0 0 0 0 0 0 0 0 96 0: 16 80 0:.,0 .0 , 319 581 203 0' 1151 11 AA-c1om 13AAocs .1.270 0.143 . ne se 35.W 4.00 45.24 2.55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 b 0 VY t-D 1100 13A4 cs; 4A5 tom ". , 13A-4ocs 1A-c1om 0.390 0.143 0170 0.143 1.270 se sw+: ,. sw nw nw 10.92 4.00 .21.56 4.00 35.56 11.31 2.65 . 27:53 2.55 45.24 0 '. 0' 0 0 0 0 0 ' 0 0 0 0 0 0 0 0 0 ..0 0 0 0 0 0 0 0 0 0 0 ' 0 0 0 0 _ -.0 - ``0 0 0 0 0 0 0 V�✓ I--G I-G• 4A5.2omd 12C Osw 16A30md 22A-tpL : 0.770 0:001 0.032 0.989 nw - - .: - 21.56 `�2:55 0.90 27.69 36.90 -1i28 2.32 ` 0.06 0 0 36 36 0 A 36 0 0 0 32 0 0 0 84 0 0 0 180 180 0 0- 180 . - .12 0 0 161 332 0 0 418 :: 0 "P.. C F 6 c)AED excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 16.15 1786 15 Duct loads I 340/o 53% 13 50 340/. 53% 541 94.5 Total room load 51 145 2156 2730 Air required (cfm) 2 6 101 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -IF14- wrigFrtsoft. 2017-Apr-10 17:19:28 AMA . . Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3 ...k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N wriohtsoft° Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name DINING/GREAT ROOM KrrCHEN 2 Exposed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft' 209.0 ft2 Ty Construction U-value Or HTM Area 2 (ft� Load number (Btuh/ft' °F) (Btuh/ftz) or perimeter (ft) (Btuh) oorperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 _W 13A4ocs 0;143 •ne 4.00 2:55 0 0 0 0 0. 0 0 .0 1Ac1om. . 1:270`'ne' 3556 70.43' p 0 p p: p p, 0.. 0 1Aclom ne 35:56 70.43 0 0 0. 0 0 0 0 ` ' 0 1'Ac1om : .1.270,' 1.270 ne' 35:56 45:24 0 _ 0 0 0 0 0 0 0 11 VL-D 13A-4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11D0. 0.390 , se 10.92 11.31 0 0 0 0 0 0 0 0 W 1.3A-4ocs 0.143 . sw 4:0(Y ' 2.55 267 226 903 574 98 98 392 - 249. a: 4A5.2om 0:770 'sw 21.56. 27.53 41 22 893 > 1140 0 p p. 13AAocs 0.143 nw 4.00 2.55 178 137 549 349 0 .0 0 0 0 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56. 36.90 41 0 880 1505. 0 0 0 0 P 12G-0sw 0,091 .- 2.55.: 1:28 0 0 0 : 0 116 :' 116 � -. . ' 295: > . " 148 C 16A-30md 0.032 - 0.90 2:32 588 588 527 1364 209 : 209 187 485 ;F 22A tpl:`:.... 0989 .. _ <' 27:69 . 0.00 588 .. 50 ". . '1385 .: 0 209 , 11 .305' :`0. 6 c)AED excursion 1004 -64 Envelope loss/gain 5136 59371 1179 818 12 a). Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal Qines 6 to 13) 6136 6679 1399 . 1880 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 151 Duct loads 341/6 53%1 2058 3541 34% 53% 4691 995 Total room load 8200 10234 1867 2875 Airrequired (cfm)' 3861 440 88 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fp-' wrightsofft- 2017-Apr-10 17:19:28 .A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N -�+ wrightsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC: By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH HALL 2 .3 EJ(posed wall Room height 5.0 ft 8.0 ft heat/cool 0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x ' 5.0 ft 50.0 ftz 5.0 x 5.0 ft 25.0 ft2 T Y Construction number U-value (Btuh/ft2L-"F) Or HTM (13tuh/ft2) Area t2) or perimeter (ft) Load (Btuh) Area t2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 11 N 13A-4ocs 1A-clom 1Ac19m °: 1Ac1om , 13A-4ocs 0143 1 270 1 270 1.276 0.143 no ne' he,35.56 ne se 4 00. 35 56: 35.56 4.00 2,55 70.43 70.43 45.24 2.55 40 0 , ,0 0 0 40 0. 0 . 0 0 160 0 0 0 0 :. 1012 0 , - 0 0= 0 . 0 0 0 0 0 ' 0'. 0 ' 0 0- 0 0 0 0 0 : 0' l) 0 V�J 11DO 13A flocs :: °4A5 zom 13A-4ocs 1Aclom 4A5-2omd 12C-0sw . 16A-30md 22A-tpl 0390 0143 :0.770' 0.143 1.270 0.770 6.091 0.032 0.989 se : sw sw nw nw nw - - - 10.92 4:00 21:56 4.00 35.56 21.56 2.55 0.90 27.69 11.31 2.55 : 27.53 2.55 45.24 - 36.90 .1:28 2.32 0.00 0 0 0 0 0 0 0 50 50. 0 0 0 0 0 0 0 50 5 0 .. 0 0 0 0 0 0 45 138 0 0 0 0 0 0 0 116 : 0 0 0 0 0 0 0 0. 25 25 0 .0 0 0 0 0 0 25 0 0 Q; Q 0 0 0 . 0 22 0 0 .0 , -0 0 0 0 " -0 58 0. 1� F-C �G P. C F 6 c)AED excursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 433 235 22 56 Less e:Qemal load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 134% 53% 147 132 340/6 53% 0 0 Total room load 586 381 0 0 Air required (cfm) 28 16 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ,=, -FjA- wrightsoft 2017-Apr-10 17:19:28 Aaek Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 ...k CalcslDocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - wrightsoft. Right.4@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 311 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER BEDROOM 3 2 Exposed wall 9.0 ft 14.0 ft • 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 92.0 ft 13.0 x 13.0 ft 5 Room area 92.0 ftz 169.0 ft' Ty Construction U-value Or HTM Area number (BtulVft'L-°F) (BtuWftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S • Heat Cool Gross N/P/S Heat Cool 6 13AAocs 1Ac1om " 'X.1:270 0.143 ne. 4.00 2.55 0, ' , 0 0 0 104 88 ':: 351 223. ne' 35.56: 70 43 0 0 Q 0 0 ` Q : 0 0 1Ac1om .' 1:270, ne, 35.56 70.43. .. 0 M. _ 0 0'. 0 p 1Ac1om 1.270 ne 35:56' 45'24 0 0: 0 '0 16 0 -:,,581, _. - 739 11 Val 13A4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 ­13 11D0 0.390 .se 10.92 11.31 23 23 248 257 0 0 0 0 13A flocs, . 0.143 sw 4t00 2;55 ­ 8 . 8 - 32 20' 8 8 32 20 i4A5-26m 0:770 : sw: 21.56 27.53 ' .0 6 : 0 .. 0 0, . 0 ' 0 -0 Val 13-c om 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 �G 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 �-( 4A5-2omd 0.770 nw 21.56, 36.90 0 0 0 0 0 0 0 0 P 12C-0 w 0.091 „ - 2:5.5' 1:28 88 88 224 113 104 , 104 .265 138 C 16A-30md 0.032 - 0.90 2.32 92 92 82 213 169 169 151 392 F 22AApl: 0.989 _ ' 27.69 .: 0.00 92 9 249 A -.169 14 •388 : - 0 6 c)AED excursion _25 -62 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 p Subtotal (lines 6 to 13) 1163 730 2020 . 1527 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1527 15 Duct loads 34% 1 53%1 390 386 340/6 53% 677 808 Total room load 1553 1116 2697 2335 Air required (cfm) .73 48 127 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .� 41&- wcigthtsoft1 2017-Apr-1017:19:28 P. Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: N Duct System Summary Job: -- wrightsoft Y Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 7.72-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AQL.COM Project Intormation For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Extemalstatic pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox0 VIFx 19.5 115.6 st1 BEDROOM 2 c 2730 101 117 0.384 7.0 Ox 0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 OxO VIFx 26.8 115.0 st1 DINING/GREAT ROOM c 3411 129 147 0.292 7.0 Ox 0 VIFx 36.5 135.0 st2 DINING/GREAT ROOM-B C 3411 129 147 0.371 7.0 Ox0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox 0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48, 0.490 4.0 Ox 0 VIFx 7.0 95.0 KITCHEN C 2875 88 124 0.366 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 Ox0 VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 Ox 0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox0 VIFx 40.9. 135.0 st2 wlc c 216 4 9 0.292 4.0 Ox 0. VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 612 602 0.273 780 12.0 0 x. 0 VinIFIX st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx .` wri htsoft° 2017-Apr-1017:19:29 - f Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ..k Calc";%Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N n Return Branch Detail Table Name Grille 'Size (in) Htg (cfm) clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl . Trunk rb1 NO 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft° 9 Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:19:29Page 2 k Calcs%Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N