HomeMy WebLinkAboutPROJECT INFORMATION-- wrightsoft° 317 ST. LUCIE LN., FT. PIERCE, Project Summary Entire House QUICK CALCS, INC. SCANNED Job: Date: BY By: St Lucie County FL 34946 Phone: 772-466-6799 Fax 772A66-6796 - Email: QUICKCALCS@AOL.COM. For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: `�ZoKNQfCN;4z�l Design Information Weather: Winter Design Conditions Outside db 42 OF Inside db. 70 OF Design TD 28 OF Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Fort Pierce, FL, US Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range L . Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipmentload Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data Rate/swing multiplier n 0.95 Equipment sensible load 25645 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolin (none) Area (W) 1753 175 Equipment latent load 5007 Btuh Volume (ft3) 14741 14741 Air changes/hour 0.38 0.20 Equipment total load 30652 Btuh Equiv. AVF (cfm) 93 49 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow. Airflow factor Static pressure Space thermostat. Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 470F 27 0 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual. air flow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible -heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. � _ + wrightsoft- age I .+ Right -Suite® Universal 2017 17.0.14 RSU08101 -Apr-10 17:Page ..k CalcslDocuments%WYNNE-THE WINDSOR-REVISED.rup Calc = M2017 J8 Front Door faces: N wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 3 . Exposed wall Room height 153.0 ft 8.4 ft d 45.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 1753.0 ftz 1.0 x 280.0 ft 280.0 ft' TY Construction number U-value (Btuh/ft'-°F) Or HTM (Btuh/f2 Area (ft-) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat I Cool Gross N/P/S Heat Cool 6 11 ' -jM4ocs; 1Xc1om 1Ac1om :. 1A-c1om . 13A-4ocs 0.143 1.270 1270 1.270 0.143 ne .ne. ne ne. se 4.00 35:56 35.56 35,56 4.00 2.55 70.43 70.43 45.24 2.55 . 488 7 16 16 64 448 0 0 . 0 41 1795' 247. 581 581 165 1141 488 1151 739 105 - 192 0 . 0 0 0 192 0: 0 , '0 0 769 ;0 0 '0 0 489. 0 0 D 0 y! �D 11DO 13A4ocs 0.390 . 0.143 se ; sw 10.92 :400 11.31 2.55 23 :. .. .437 23 . 396 248 - 1584 257 _ 1007 0 56 0 " 56 0 224 0 143 r, G :4A5-tom 0:770 ' sw- 21 58 27 53 41 45 893 1140 0 0 . A 0 13AAocs 1Aclom 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 290 33 217 0 867 1162 551 1478 112 33 79 0 318 1162 202 1478 P ' ; C 4A5.2omd '.12C-0§w 16A-30md 0.770 0.091 0.032 -nw . - - 21.56 255 0.90 36.90 1;28 2.32 41 308 1753 0 $08 1753 880 ' 784 1571 1505 395 4067 0 0 280 0 0 280 0 0 251 0 0 650 'F " 22Artpl" . _ . - 0.989 . - . 27.69 0.00 1753 . - 153 4237 ' -0 ... 280 . ".. . 45 1246 0 6 c) AED excursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal pines 6 to 13) 18467 17655 4779 3789 Less external load 0 0 0 0 Less.transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 DUctloads 340/o 53% 6190 9340 34% 53% 1602 2005 Total room load 24657 2699577 6380 5794 Air required (cfm) 1160 1160 300 249 P A 1� -- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 ...k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: 2017-Apr-10 17:19:28 Page 1 - wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-0796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M. BATH. 2 3 4 5 Exposed wall Room height Room dimensions Room area 0 ft 8.0 ft heat/cool 7.0 x 9.0 ft 63.0 ft2 7.0 ft 8.0 ft heat/cool 1.0 x 61.0 ft 61.0 ftz Ty Construction number U-value (Btuh/ft2L-°F) Or HTM (Btulff) Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-0ocs 1Ac1om 1Ac1om : ' 51Ao1om :. ' 13AAocs 11D0 13A 4acs; ,�4A5.2om " , 13A4ocs 1Aclom 4A5-2omd `12C-0sw; 16A-30md '22Aetpl.: 0.143 1.270 1.270 1.270 0.143 0:390 0:143 0:770 0.143 1.270 0.770 0.091 0.032 0:989 ne -he' ne . ne se se 'sw sw. nw nw nw "..-' - - 4 00 35.56 35.56 35:56 4.00 10.92 4.00 21.56 4.00 35.56 21.56 "2.55:'' 0.90 27,69 2 55 7043 70.43': 45.24 2.55 11.31 2:55 . 2753 2.55 45.24 36.90 1:28 2.32 0.00 0 0 0 0 0 0 0- ' 0 0 0 0 .` 0 63 " 63 0 0 0 . 0 0 0 0 0 0 0 0 0` 63 0 0.1 0. 0' ' 0 0 0 .0 0. 0 0 0 0 56 0 0 0 01 0 0 0 . 0 0 0 0 0 0 146 . 0 56 7 0 0 0 0 0 0 0 0 0 0 61 ' . 61 49 "0.: 0' ' 0 0 0 0 0 0 0 0 61 . 7 • 196. ':247,11 0 : 0 0 0 . 0 0: 0 0 0 55 194 125 488 0: 0 0 -':0 , 0 0 0 0 142 ': 0 �1 I--G �--G P C F 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1 0 Subtotal (lines 6 to 13) 56 141 817 . 764 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 754 151 Duct loads 1 34% 53% 19 75 34% 53% 274 404 Total room load 75 216 1091 1168 Air required (cfm) 4 9 51 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �A wrigFttsoTt' Rlght-Suite® Universal 2017 17.0.14 RSU08101 2017-Apr 10 1 Page 2 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cato = MJ8 Front Door faces: N - wrightsofta Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 2 3 EAposed wall Room height 0 ft 8.0 It heat/cool 12.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ftz 15.0 x 12.0 ft 180.0 ftz Ty Construction number U-value Btuh/ftz-°F ( ) Or . HTM (Btu Area (ftz) or perimeter (ft) Load (Btuh) Area (ft z) or perimeter (ft) Load (Btuh) Heat I Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 11 " VN - I-p 13AAccs 1Ac1om 1X616m 1A�1onr 13A-4ocs 0.143 1.270 1.270:..nb .1.270 0.143 .ne ne: . ne se 4.00 35:56 35.56. 35.56 4.00 . Z55 70.43 70.43. 45.24 2.55 0 0 0 - 0 0 0 0 0 0 0 0 0 0 0 0 0 ` 0 0 .0 0 96 " 0 .. 16 0 0 80 0. .. 0 0 0 . 319 0. , 581' .0 0 20$ 0 1151 0" 0 11D0 13A�ocs,....."' 4A5 tom°. 0.390 ;Q.143 0 770 se sw+ : sw 10.92 -00 .21.56 11.31 2.55 .. 27.53 0 ' - 0. . 0 0 . " 0 0 0 . 0 U 0 : " 0 o 0 `. 0 01 0 :..' 0., 0 ::0 0 ;0 . 13AAocs lAmc1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5.2omd ;12C-0sw 16A-30md 22/ktpl?:: r 0.770 0091 0.032 0:989 nw "- - . - 21.56 '255 0.90 27.69 36.90 128 2.32 0.06 0 0 36 36 0 .0 36 0 0 0 32 0 0 0.." 84 0 0 0 180 • 180 0 0 180 . 12 0 0 161 332 0 0 418 0 P C F 6 c)AED excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) . Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 17.72 Less exfemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads .34% 53% 13 50 34% 530/0 541 945 Total room load 51 145 2156 2730 Air required (cfm) 21 61 1011 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -Fl=,- wrightsoft- 2017-Apr-10 17:19:28 .10M Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - - wrlotsofe Right4@ Worksheet Job: Entire House Date: QUICK CALLS, INC. By: 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area DINING/GREAT ROOM 50.0 ft 8.9 ft heat/cool 1.0 x 588.0 ft 588.0 ft' KITCHEN 11.0 . ft 8.9 ft heat/cool 19.0, x 11.0 ft 209.0 ft' Ty Construction number U-value. (Btuh/fV-°F) Or HTM (Btuh/ft2) Area (ft2)Load or perimeter (ft) (Btuh) Area (W) o perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 y! ' 13A4ocs X06rii 1A-c1om " 9Ac1am`. 13A4ocs 11D0 13A floes- .. 13A4ocs " 1A-c1om 4A5-2omd 12C .-Osw' 16A30md ;22A tpl,' .. 0A43 1:270 1.270 1:270 0.143 0.390 0.143 0.143 1.270 0.770 0.091 0.032 0:989 .ne ne ne nw se se sw nw nw nw •-: 4:00 35:56. 35.56 35.56 4.00 10.92 4.00' 56 . 4.00 35.56 21.56, Z55' 0.90 27.69 2.55 7.0.43; _ 70.43 45:24 2.55 11.31 .. 2.55 5 2.55 45.24 36.90 ". ..1i28 2.32 - 0.00 0 0 - 0 0 0 0 267 178 0 41 . 0 588 5M 0 0 0 0 0 0 226 137 0 0 ' 0 588 50 0 0 0. 0 0 0 903 . 549 0 880. 0 527 :, 1385:: 0 0. 0 0- 0 0 574 . 349 0 1505 0 1364 0 0 0 0 0 0 0 98. 0 0 0 : 116 209 .: 209 0 0 ; -0 0; 0 0 98 0 0 0 0 r:. ' � 116`.295' 209 0 ;0 0 0_ 0 0 392 :0 0 0 0 187 0 0 0 0 0 0 249�G 0, 0 0 0 148' 485 . P C ,F 6 c)AED excursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a). Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13) 6136 6679 1399 . 1880 Less Wemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 6 6142 0 14 6693 0 0 1399 0 0 1880 15 Duct loads 34% 53% 2058 3541 340/a 53% 469 995 FTTotal room load 8200 10234 1867 2875 Air required (cfm) 386 440 88 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Apr-10 17:19:28 .��A Right -Suite® Universal 2017 17.0.14 RSU08101 Page:4 ..k Cm alcs\Docuents\WYNNE-THE WINDSOR-REVISED.rup .Galt = MJ8 Front Doorfaces: N + wr ghtsoft- Right-JO Worksheet Job: Entire House Date: • QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name BATH HALL 2 Exposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heattcool 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 5.0 ft 50.0 ftz 5.0 x 5.0 ft 25.0 ft2 Ty Construction number U-value (Btuh/ft'-'F) Or HTM (Btuh/ft2) Area (ftz) or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Btuh) Heat Cool I Gross N/P/S Heat Cool Gross N/P/S Heat cool 6 11 At. 1Ac1om ` 1Ac1om .: 1A-01cm : 13A4ocs 0.143 1.270 1:270 1,270 0.143 ne:4.00_*-,2,55 rie' ne ne' se 35.56 35.56 35.56 4.00 70.43 70.43 45.24 2.55 . 40 0 : .0 0 0 40 0 0 . 0 0 . 160 0 0 0 0 _ 102 • 0 0 0. 0 .: 0 0:. 0 0 0 0 :0. 0 0. 0 ., 0 ;0 0 0 0 0 0. 0'. ,.. 0 0 1N l-D 11DO 13AAocs : ;4A5 tom ° 0.390 0:143 -0.77o se :sw : sw 10.92 ;4200, 21:56 11.31 ..2.55 . 27.53 0 .. 0 0 0 0 ` - 0 0 .. 0 0 0 0 0 0 0 0 0 0 ` 0 0 .0 :U; 0 6 ViJ 13A-4ocs IA-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 LG 4A5-2omd :12C=0sw 16A-30md 0.770 6.091 0:032 nw - - 21.56 2.65 0.90 36.90. 1128 2.32 0 0 50 0 0 50 0 0 45 0. 0 116 0 0 25 0 0 25 0 0 22 0 0 58 P- C F ...::22A-tpl 0:989 . - - . 27.69 0.06 ' 50 5 138 : 0 :25 0 0 0 6 c)AED excursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 433 235 22 .56 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 6 439 0 14 249 0 -22 0 0 -56 0 15 DuctlOads 34% 53% 147 132 34% 53% .0 0 Total room load 586 381 ---V-0 0 0 Air required (cfm) 28 16 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 411- wrightsoft2017-Apr 10 17:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 k Calcsk0ocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N wrightsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-166-6799 Fax 772466-6796 Email: QUICKCALCS@/AOL.COM 1 Room name FOYER BEDROOM-3 2 3 Exposed wall Room height 9.0 ft 8.0 ft heat/cool 14.0 ft 8.0 ft heattccoi 4 5 Room dimensions Room area 1.0 x 92.0 ft 92.0 ft2 13.0 x 13.0 ft 169.0 ft2 Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 G.1 1.13A-4ocs 1Ac1cm " 1Ac1am .' Ac1om 13AAocs 0.143 1:270 1.270 1.270 0.143 ne_ ne iie. ne se 4;00 35.56 35.56 35. 58' 4.00 255 70.43 7043: . 45:24 2.55 0. 0 0 0 64 0 0 0 0 41 0 0 0 0 165 0 0 0 0 105 104 : 0 0 16 0 88. : 0 0 0: 0 351: '. •0 0' 581 0 223. 0 0 739. 0 W -D 11DO ., 13A�ocs 4A526m - 0.390 •0.143 0:770' .se sw sw 10.92 4.00 21.56 11.31 255 . 27:53 23 . 8 0 23 8 0 . 248 32 0. 257 20 0 0 8 0 0 8 0 0 - 32 6'. 0 -20 0 V�/ I-f 13A-4ocs 1A-c1om 4A5.2omd 12C-0sw- 16A-30md 22A-tpli - 0.143 1.270 0.770 0.091 0.032 0.989 nw nw nw ', = - - - 4.00 35.56 21.56 2.55 0.90 27.69 2.55 45.24 36.90 .1.28 2.32 ,. 0.06 0 0 0 ` ;88 92 92 0 0 0 88 92 9 0 0 0 224 82 249 0 0 0 113 213 0 0 0 0 104 169 169 0 0 0 -104 169 14 0 0 0 265 151 . !388 0 0 0 133 392 '.. .0 F ' C -F 6 c)AED excursion -25 -52 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1163 730 2020 1527 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 1163 0 0 730 0 0 2020 0 0 1527 1151 Duct loads 34% 53% 390 386 34% 53%1 677 808 Total room load Air required (cfm) 1553 73 1116 48 2697 127 2335 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. .� -F- wrigFrtsoft- 2017-Apr-10 17:19:28 P. Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 ... k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N -- wrightsoft° Duct System Summary Dab Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS ,AOL.COM P • ject Intormation For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox 0 VIFx 19.5 115.6 st1 BEDROOM 2 c 2730 101 117 0.384 7.0 OxO VIFx 15.0 115.0 SO BEDROOM 3 h 2697 127 100 0.353 6.0 Ox 0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 Ox 0 VIFx 36.5 135.0 st2 DINING/GREAT ROOM-8 C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox 0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 OxO VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 Ox0 VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 Ox 0 VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 1.50 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 .0.284 6.0 Ox 0 VIFx 40.9. 135.0 st2 WIC c 216 4 9 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx wri htsoft° 2017-Apr-1017:19:29 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...k CalcMDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) clg (cfm) TEL (ft). Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl . Trunk rb1 Ox0 1160 1160, 0 0 0 0 Ox 0 VIFx wri htsoft° 2017-Apr-1017:19:29 f 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N