HomeMy WebLinkAboutENERGY EFFICIENCY CODEbUANINIvU
BY
FORD - R405-2014
St Lucie County
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
;Flori&,Department of Business and Professional Regulation - Residential *Performance Method
Pr,kject Name: WYNNE THE WINDSOR
Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERPE, FL
')n C_Q
Permit Number:
Owner: S
Jurisdiction:
Design Location: FL, Fort Pierce
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
10. Ceiling Types (1753.0 sqft.)
Insulation Area
5. Is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
a. U-Factor: Sgl, U=0.54 111.36 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1753.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 53.74
PASS
Total Baseline Loads: 53.87
I hereby certify that the plans and specifications covered by
Review of the plans and
S'P
this calculation are in compliance with the Florida Energy
specifications covered by this
O��$E
Code.
calculation indicates compliance
yrt+ 4q '' , , - _
with the Florida Energy Code.
m„'% •.;;::. ,•;.,,ti O
PREPARED BY:
DATE: 734#!_A7T7
Before construction is completed
this building will be inspected for
compliance with Section 553.908
c
OBI
* 1i
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
COD
OWNER/A
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM.R405-2014
Title`
WYNNE THE WINDSOR
Building Type:
User
Owner:
# of Units:
1
Builder Name:
WYNNE DEVELOPMENT
Permit Office:
ST. LUCIE COUNTY
Jurisdiction:
Family Type:
Single-family
New/Existing:
New (From Plans)
Comment:
PROJECT
Bedrooms:
3
Conditioned Area:
1753
Total Stories:
1
Worst Case:
Yes
Rotate Angle:
225
Cross Ventilation: No
Whole House Fan: No
Address Type:
Street Address
Lot #
Block/SubDivision:
PlatBook:
Street:
THE WINDSOR
County:
ST. LUCIE COUNTY
City, State, Zip:
FT. PIERCE,
FL,
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO BEACH MUNI 2 39 90 70 75 299 62 Low
BLOCKS
Number Name
1 Entire House
Area Volume
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil.ID
Finished
Cooled Heated
1
MASTER BEDROO
224 1792
No
0
1
1
Yes
Yes
Yes
2
WIC
63 504
No
0
1
No
Yes
Yes
3
MASTER BATH
56 448
No
0
1
Yes
Yes
Yes
4
M.BATH
61 488
No
0
1
Yes
Yes
Yes
5
LAUDRY
36 288
No
0
1
No
Yes
Yes
6
BEDROOM 2
180 1440
No
0
1
1
Yes
Yes
Yes
7
DINING/GREAT R
588 4704
No
2
1
Yes
Yes
Yes
8
KITCHEN
209 1672
Yes
0
1
Yes
Yes
Yes
9
BATH
50 400
No
0
1
Yes
Yes
Yes
10
HALL
25 200
No
0
1
No
Yes
Yes
11
FOYER
92 736
No
0
1
Yes
Yes
Yes
12
BEDROOM 3
169 1352
No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 37 ft 0
224 ft2
----
0
1
0
2 Slab -On -Grade Edge Insulatio
WIC
1 ft
0
63 ft2
----
0
1
0
3 Slab -On -Grade Edge Insulatio
MASTER BATH
8 ft 0
56 ft2
----
0
1
0
4 Slab -On -Grade Edge Insulatio
M. BATH
7 ft 0
5 Slab -On -Grade Edge Insulatio
LAUDRY
1 ft
61 ft2
zi
0
36 ft2
I
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
FORM. R405-2014
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value Tile.
Wood
Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2
12 ft
0
180 ft2
---- 0
1
0
I
7Slab-On-Grade Edge Insulatio
DINING/GREAT
50 ft
0
588 ft2
---- 0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN
11 ft
0
209 ft2
---- 0
1
0
9 Slab -On -Grade Edge Insulatio
BATH
5 ft
0
50 ft2
---- 0
1
0
10SIab-On-Grade Edge Insulatio
HALL
1 ft
0
25 ft2
---- 0
1
0
11SIab-On-Grade Edge Insulatio
FOYER
9 ft
0
92 ft2
---- 0
1
0
' 12Slab-On-Grade Edge Insulatio
BEDROOM 3
14 ft
0
169 ft2
---- 0
1
0
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Metal 1847 ft2 292 ft2 Light 0.6 No 0.9 No 0 18.4
ATTIC
# Type Ventilation Vent Ratio (1 in) Area RBS
1 Full attic Vented 150 1753 ft2 N
CEILING
# Ceiling Type Space R-Value Ins Type Area
1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2
2 Under Attic (Vented) WIC 30 Blown 63 ft2
3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2
4 Under Attic (Vented) M. BATH 30 Blown 61 ft2
5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2
6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2
7 Under Attic (Vented) DINING/GREAT 30
$ Blown 5ss ft2
Under Attic (Vented) KITCHEN 30
Blown 209 ft2
9 Under Attic
(Vented) BATH 30
10 Under Attic (Vented) Blown 50 ft2
11 HALL 30
Under Attic (Vented)
FOYER 30 Blown 25 ft2
12 Under Attic (Vented) Blown 92 ft2
BEDROOM 3 30
Blown 169 ft2
WALLS
Adjacent
Space Cavity Width
1 NE=>W Exterior Concrete Block - Ext InsMIgSTER BE Height
2 SW=>E Exterior Concrete Block - Ext In�WSTER BE 4.11 16 p 8 0 128 0 ff2
3 NW=>S Exterior Concrete Block - Ext InsUASTER BED 4.1 14 0 8 0 56.0 ft2
4 NE=>W Exterior Concrete Block - Ext InSUASTER BAD 4.1 0 8 0 112.0 2
8 0 8 0 64.0 ft22
7/6/2017 2:37 PM
EnergyGaugee USA - FlaRes2014 Section R405.4.1 Comniimni
IRCC
N
Framing Frac
Truss Ty
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
0.1
Wood
.ai
Wood
0.1
wood
0.1
Wood
0.1
Wood
$heathi�9 Fca
rni
0 0
0 0
0 0
0 0
Solar Belo0-5�4w
0
0.5 0
0.5 0
0.5 0
Page 3 of
WALLS
Adjacent
Cavity ity Width
Height
Sheathing Framing Solar
Below
-� 5
NE=>W Exterior
Concrete Block - Ext InsuM. BATH
4.1 7
0
8
0
56.0 ft2
0
0
0.5
0
6
NE=>W Exterior
Concrete Block - Ext InfiffDROOM 2
4.1 12
0
8
0
96.0 ftz
0
0
0.5
0
7
SW=>E Exterior
Concrete Block - Ext In§XlNING/GRE
4.1 30
0
8
0
240.0 ftz
0
0
0.5
0
8
NW=>S Exterior
Concrete Block - Ext In9WNING/GRE
4.1 20
0
8
0
160.0 ft2
0
0
0.5
0
9
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8
0
88.0 ft2
0
0
0.5
0
10
NE=>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8
0
40.0 ft2
0
0
0.5
0
11
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8
0
64.0 ft2
0
0
0.5
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8
0
8.0 ft2
0
0
0.5
0
13
NE=>W Exterior
Concrete Block - Ext InflffDROOM 3
4.1 13
0
8
0
104.0 ft2
0
0
0.5
0
14
SW=>E Exterior
Concrete Block - Ext InfiffDROOM 3
4.1 1
0
8
0
8.0 ft2
0
0
0.5
0
15
N=>SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft2
0.23
0.5
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
V
Wall
Overhang
# Ornt ID
Frame Panes NFRC U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single Yes
0.54 0.25
32.4 ft2
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5
Metal Low-E Single Yes
0.54 0.25
6.9 ft2
1 ft 0 in
1 ft4 in
None
None
3 NE=>W 6
Metal Low-E Single Yes
0.54 0.25
16.2 ft2
1 ft 0 in
1 ft 4 in
None
None
4 SW=>E 7
Metal Low-E Single Yes
0.54 0.25
39.8 ft2
1 ft 0 in
1 ft 4 in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.55 0.25
40.0 ft2
8 ft 0 in
1 ft 4 in
None
None
6 NE=>W 13
Metal Low-E Single Yes
0.54 0.25
16.2 ft2
1 ft0 in
1 ft4 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82
168.92
.2598
7
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
1., 7
FORM. R405-2014
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit
Split
SEER: 15 34.8 kBtu/hr cfm
0.85
1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftZ
DUCTS
V
— Supply —
---- Return ----
Air
CFM 25
CFM25
HVAC #
#
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6 325 ftZ
Attic
95 ft2 Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[[ �Jan
Heatin[X]
Feb Mar
Jan Feb Mar
A r
Apr
May X Jun [X Jul
May 4 Jun [ Jul
Au
rl Au
X Se
Sep
Oct
Oct
Nov
Dec
XDec
Ventin [ ]
Jan Feb X Mar
X
[X A r [
Ma [ Jun [ Jul
Aug
[ Se
[X
Oct
XNov
X Nov
[ Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM 78
78 78
78 78 78
78
78
80
80
80
80,
PM 80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78
78
78
78
78
78
78
PM 78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces -shall have
gasketed doors
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
0-
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ftZ
7. Windows"
Description
a. U-Factor:
Sgl, U=0.54
SHGC:
SHGC=0.25
b. U-Factor:
Sgl, U=0.55
SHGC:
SHGC=0.25
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
THE WINDSOR, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1224.00 ftz
b. Frame - Wood, Adjacent
R=11.0
208.00 ft
1
c. N/A
R=
ftZ
3
d. N/A
R=
ftZ
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1753.00 ftZ
1753
b. N/A
R=
ft2
c. N/A
R=
ftZ
Area
111.36 ftZ
11. Ducts
R ftZ
a. Sup: Attic, Ret: Attic, AH: Attic
6 325
40.00 ftZ
12. Cooling systems
kBtu/hr
Efficiency
ftZ
a. Central Unit
34.8 SEER:15.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ftZ
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.8 HSPF:8.50
2.850 ft.
0.250
Area
14. Hot water systems
1753.00 ftZ
a. Electric
Cap: 40 gallons
EF: 0.97
ftZ
ftZ
b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. "
Builder Signature: Date:
Address of New Home: �`� �j S S City/FL Zip:,
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
7/6/2017 2:37 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1