Loading...
HomeMy WebLinkAboutPROJECT INFORMATION-- wrightsoft0 Project Summary Entire House QUICK CALCS, INC. SCANNED Date: BY By: St Lucip- NUMV For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db. 70 OF Inside db . 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipmentioad Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) . (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25645 Btuh Method Simplified Latent Cooling Equipment Load Sizing . Construction quality Average Fireplaces 0 Structure 2453 Btuh . Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft2) 1753 1753 Equipment latent load 5007 Btuh Volume (ft') 14741 14741 Air changes/hour 0.38 0.20 Equipment total load 30652 Btuh Equiv. AVF (cfm) 93 49 Req. total capacity at.0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 . AHRl ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47*F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800'. Btuh Actual air flow 1160 cfm Actual airflow 1160 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat: Load sensible heat ratio 0.84 Capacity balance point = 34 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -r- wrightsoft` 2017-Apr-1017:19:28 .+ Right -Suite® Universal 201717.0.14 RSU08101 Page 1 C` ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N i wrightsofts Right-.l® Worksheet Job: Entire House Date: • QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.•466-6796 Emaib QUICKCALCS AOL.COM • 1 Room name Entire, House MASTER BEDROOM 2 . Exposed wall 153.0 ft 45.0 ft 3 Room height 8.4 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 280.0 ft 5 Room area 1753.0 ft2 280.0 ft2 Ty Construction U-value Or HTM Area . (ft-) Load Area (ft-) Load number (Btuh/ftl-- F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0ocs 0.143 ne 4 00 , 2.55 488 448 1795 1141 192 192 769 489 1A-c1om 1.270 ne 35.56 7043 7 0 247 a 0 0, ;0 0 1A-c1om 11.;270 ne 355t216 i . t 70.43' . 16 0 -581 1151 0.,".: 0., 0 0 45:� 16 . ,. 0,: 0 0 0 11' 1A4ocs 0.143 se 4.00 64 41 1 165 16 105 105 0 0 0 0 se 23 23 248 257 0 0 0 0 . 13A�ocs. ; 0143 sw `sw: 4.00 _ 2.55 .. 437 • . 396 .: ;1584 :1007 : 56 56 , :. 22, 143 4A5 tom . O:T/0 : 21 56 - 27:53 41 45 893 ;. 1140 . r• 0 0 0. •: 0 13AAocs 0.143 nw 4.00 2.55 290 .217 867 551 112 79 318 202 1Ac1om 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 4A5-2omd 0.770 nw. 21.56 . 36.90 41 0 880 1505 0 0 0 0 P : ; 12C Osw>.: • - ' . .. : 0 091 .: _..... 2:55 . ..1:28 '308 :., . r308 :: `.784 , 395 , 0 > . ; 0 ... 0 ;;0 C 16A 30md 0.032 0.90 2.32 1753 1753 1571 4067 280 280 251 650 , - .. 2769 .:' 0.00 ;. •' 1753-- - - 153 : 4237 .': 0 280 r i ' : 45 6 c)AED exursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1GO01 0 Subtotal pines 6 to 13) 18467 17655 4779 3789 Less external load 0 0 0 0 Less transfer 0 . 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 340/a 53% 6196 9340 34% 53% 1602 2005 Total room load 24657 26995 6380 5794 Air required (cfm) 1160 11601 300 249 Calculations approved byACCA to meet all requirements of Manual .J 8th Ed. - wrightsoTt' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr'10 1Page1 ... k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - F wrightsoft° Right® Workshed Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name WIC M. BATH 2 Exposed wall 0 It 7.0 ft 3 Room height 8.0 It heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 1.0 x 61.0 ft 61.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft'�-°F) (Btuhlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 1' 13A-4ocs 1A-c1om 1A c1om :: 1Ac1om `. 13A4ocs 11DO 13A�7ocs 4AS2om ::; 0.143 1;270 1.270 1:270 0.143 0.390 0143 0:770 ne ne : ne ne se se, sw: sw:• 4 00, 35 56 35 56 3556', 4.00 10.9.2 '. 4 00 21 56 255 70 43 ': 70 43 .45:24' 2.55 11.31. ' 255 : .27:53 A 0 . 0: 0 0 0 - _ ,0 0 0 0 0 0, 0 0. 0 0 0 0 0 0: 0 0 0 0 0 .0 0 �.p 0 0. 0 0 56 7 0 p' 0 0 0 0 49 '0 i 0 p': 0 0 0 : 0 198 ; 247, 0 0 0 0 . -0. 125 488 0 0 0 0 _:0. 0. ,. L-D 1=G \Q! 13A4ocs 1A-clom 0.143 1.270 nw nw 4.00 35.56 255 45.24 0 0 0 0 0 0 0 0 0 0 0 0 -.,0 0 0 0 0 4A5-2omd °12C-0sw' 16A 30md 0.770. 0.091 0.032 nw ". - 21.56 ..'2.55 0.90 36.90 `' 128 2.32 0 . 0 63 0 0 63 0 6 56 0 0 146 0 0- 61 0. 61 0 55 0 142 P C F 2: AMpt : `.: ,: • 0 .489. - _ 27i69::' 0.00 .. 63 . 0 0': 0 61 _ 7 194' :` '0. 6 c)AM excursion -5 -26 Envelope loss/gain 56 1411 692 729 12 a) Infiltration 0 0 126 35 b) 'Room ventilation 0 0 01 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pins 6 to 13) 56 141 817 764 Less e)demal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 56 . 0 0 141 0 0 817 0 0 764 15 Duct loads 34% 1 539/6 1 19 75 34% 53% 274 404 Total room load 75 216 1091 1168 Air required (cfm) 41 9 51 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 :119:28 .:k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N 9 - wrightsoft RighW@ Worksheet Date: Da t Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS !AOL.COM 1 Room name LAUDRY BEDROOM 2 2 Exposed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaVcool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 W 15.0 x 12.0 ft 180.0 ftz Ty Construction U-value Or HTM Area (ft) Load Area (ft2) Load number (Btuh/ft' °F) (Stuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 11 13A40cs 1A cloro 1A-c1om _ A clam , 13A4ocs 0.143 1270 1270 1.270 0.143 ne ne ne ne se .400, ;, 35 56 35 56 . 35 56 4.00 . 2.55 : 70.43 70.43 45.24 2.55 0 .. 0 : 0 U 0 0 - 0 0 . 0 0 0 0 0 U 0 0 . 0 ' 0 .0 0 96 p 16 - 0 0 80 : - 0 ,. 0 0 0 319 0, ` 581, _ 0 0 203 0 1151'. 0 0 11DO 13A-0ocs :. 4A5 tom 0.390 0.143 0 770 se sw : . sw, 1092 4 00 :.. 21.56 11.31 : 2.55 :: 27 53 0 " - :0 0 0 0 0 0 0 0 0 0 0 0 ` 0 .. 0 0 . 0 0: 0 .. 0 0 0 0 0 y! �-G �G 13A4ocs 1Ac1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 r-G. P C F ,4A5.2omd `72C-0sw' , ' ....: 16A-30md 22A tpl 0.770 0:091 0.032 0:989 nw • . - .:.. - : - . 21.66 2 55 0.90 -' .27:69 36.90 ` 1:28 2.32 :;. 0.00 0 0 36 36 0 .0 36 0 0 ` 0 32 , 0 0, 0 84 .. 0 0 := 0 180 180 0 ... 0 180 ; ... 12 0 , 161 332 0 ;0 418 6 c)AED excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a)Infiltration 0 0 216 61 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53% 13 50 34% 53% 541 945 7 Total room load 51 145 2156 2730 Air required (cfm) 21 61 1 1 101 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Arm - wrighisoft- . Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 3 ... k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N + wrightsoft Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST, LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.46"799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name DINING/GREAT ROOM KrrCHEV 2 E)q)osed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 5 Room dimensions Room area 1.0 x 588.0 ft 588.0 ft2 19.0 x 11.0 ft 209.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-'F) (Btuh/ft2) or perimeter (ft) (Btuh). or perimeter (ft) (Btuh) Heat 7CO01 Gross N/P/S Heat Cool Gross WPM Heat Cool 6 13A torn 1A�1om 1%Ac1om 0:143 1:270 1.270 ne ne . nw. .4.00- , 35 56 35 56 2.55 - 70.43 ' 70.43 . 0 0 0. 0 0 0 0 0 0- 0 0 0 0 0 0 0 0 .0 0 .0 0 0 0 0 1 i 1A�1om : 13A4ocs 1(270 0.143 ne se .35.56 4.00 45.24 2.55 0 0 0 0 : 0 0 :. 0. 0 .:, 0 0 U 0 0. 0 0 0 V)I -D LVI/ -p DO 13A�ocs - 4A5 tom. 0:390 0:143 0:770 se sw ; • sw. 10 92 4 00 2156 - 11 31 2,65 ;. 27.53 0 ` . 267 ' 41 0 .226 22 0 , 903 893 0 ' S74 ; . 1140 0 98 .. 0 0 ' 98 : 0 -,392 '' ;0 I249: 0' 13A4ocs 1Ac1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 178 0 137 0 549 0 349 0 0 0 0. 0 0 0 _ 0 0 4A5-2omd 16A-30md 22A,tp1' = ,.. 0.770 0091 0.032 0.989 nw :- - .. _ 21.56. 2:55` 0.90 27:69. . 36.90 128 2.32 0.00 41 0 588 588 0 U 588 50 880 0.. 527 , ' 1385 1505 6 1364 ; 0 0 ,:116'. 209 ; 209 0 116.. 209 11 0 `•295. 187 305 0 148' 485 0 �-G C F 6 c)AED excursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 1000 282 220 62 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal Pines 6 to 13) 6136 66791 1399 . 1880 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 151 Duct loads I 34°/u 531/o 1 2058 3541 34% 53% 469 995 Total room load 8200 10234 I I 1867 2875 Air required (cfm) 386 440 I ffil 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. >✓A -- wrightsoTt' RightSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page ae 4 k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N 9 -9+ wr 0tsoft Right-M Worksheet °b Entire House Date' By. QUICK CALLS, INC. 317 ST..LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name BATH HALL 2 Exposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 5.0 ft 50.0 ftz 5.0 x 5.0 ft 25.0 ft2 Ty Construction number lJ-value BtuWftk*F ( ) Or HTM (Btuh/ftz) Area (ftz) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1 T V.. �! t-D 13AAocs 1A-clom 1Ac1am 1A c1om !. 13A-0ocs 0.143 1:276 1;270 1.270 0.143 ne ne ne . ne. se 4 00 35.56 35 56 35.56 4.00 : 2.56 70.43 : 70.43 45.24 2.55 40 '0 . .0 0 0 40 iO 0 . 0 0 160 0 -0 0 0 102 0 _ 0 0 0 0 . 0. A . :. 0 0 0. .0: s :. 0 ' . 0 0 0 -0. =0 , 0 0 0 0 : 0 ._ . :. -Po 0 11DO 13A�tocs :: 4'A5 tom q.., . 0.390 0;143 0.770 se sw'. sw) , 10 92 4;00:. 215s 11.31 2:55 _. 27.53 0 ". 0 0 0 0 .. 0 0 _ . 0 0 0 0 0 0 p 0 0 ° 0 ... 0 . 0 :0 ` : 0 0 ;0 0 0 13AAocs 1Aclom 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2omd '12C-0sw: -. 16A30md 0.770 0:091 0.032 nw = - 21.56- 2:55.. 0.90 , 36.90 .1:28 2.32 . 0 0 50 0 .0. 50 0 10 45 0 0': 116 0 0. 25 0 0 25 0 .: 01: 22 0 0 58 P C F 0 989 • = : 27.69 ..0:00 :. ,:. ' S0 5 138 ': 0 .. 25, :..: ' :0. . • . p 0 6 c)AED excursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Pines 6 to 13) 433 235 22 56 Less extemal load 0 0 0 0 Less .transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 134% 53% 147 . 132 349/6 53% .0 0 Total room load 586 381 0 0 Air required (cfm) 28 16 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. - -Fp- wrightsoft' 2017-Apr-10 17:19:28 AWP. Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 ..:k Calcs\DocumentslWYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N + vi r gksofr Right-JO Worksheet Jab: Entire House Byte: QUICK CALCS, INC. 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER BEDROOM-3 2 Exposed wall 9.0 ft . 14.0 ft 3 Room height 8.0 ft heat1cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 92.0 ft 92.0 ft2 13.0 x 13.0 ft 169.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area(ft2) Load number (Btuh/ft�°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13AAocs 1Aclom 1Ac1drn .. ,. 0.143 1:270 1;270 ne ne ne; : .4.00: 3556 , 35 56 2.55 7043 : 70 43 0 0 : 0 0 0 0 0 0 0 0 0 . 0 104 0 0 88 0 - 01 35.1 .0 0 223 0 0 1 f Y. 1A clom ; 13AAoos 1.270 0.143 ne se 35m 4.00 45 24 2.55 ' . 0 64 ; 0 41 U 165 < 0 105 1'6 0 0. 0 : 581 0 .. 739 0 11D0 13A�ocs 4A5 tom 0.390 0143 0. se sw.' sw: 10.92 4:00: 21.56' 11.31 l 2 55 : -27.63 23 8 0.. 23 8 0- 248 .. 32 0 . 257 .. .. 20 0 0 8 - 0'; 0 ,. $ 0 0 _ 32 0 0 2p D 13AAocs 1A-clom 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2omd 1:12C-0sw; .. 16A30md 22A tpl ' 0.770 0:091 0.032 0:989 nw s .= . - . - 21.56 2;55: 0.90 : , ' 27:69 36.90 1:28 Z32 -: 0.00 0 88 92 . :. = 92 0 88 92 - .. .9 0 224 82 249 0 113 213 .' 0 0 , 104 169 . : ; 169 0 `... 104- 169 14 0 - 265 151 : :388. 0 133 392 ... ; ; 0. P . C F 6 c)AED excursion -25 52 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 .252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1163 730 2020 1527 Less exfemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 . Subtotal 1163 730 2020 1527 151 Duct loads 1 34% 53%1 390 386 341/o 53%1 677 808 Total room load 1553 . 1116 2697 2335 Air required (cfm) 73 48 127 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A&-ik wrightsofY 2017-Apr-10 17:19:28 k Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 ... k Calcs\DocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N -- wrightsoftDuct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 7.72-466-6799 Fax 772-46676796 Email:. QUICKCALCS@AQL.COM e-roject Intormation For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Job: Date: By: • Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available.static pressure 0.50 in H2O 0.50 in H2O Supply /: return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.273 in/100ft 0.273 in/100ft Actual air flow 1160 cfm 1160 cfm Total effective length (fEL) 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (n) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox0 VIFx 19.5 115.6 st1 BEDROOM c 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM C 3411 129 147 0.292 7.0 Ox 0 VIFx 36.5 135.0 st2 DINING/GREAT ROOM-8 C 3411 129 147 0.371 7.0 Ox 0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 OxO VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox0 VIFx 7.0 95.0 KITCHEN C 2875 88 124 0:366 6.0 Ox0 VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 Ox0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM, A h 3190 150 124 .0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 W1O c 216 4 9 0.292 4.0 Ox 0 VIFx 36.0 135.0 st2 Trunk Name Type HtgE(clg (cfm)fm) Design FR Veloc (fpm) Diam H x W Duct (in) (in) Material Trunk st2 Peak AVF st1 Peak AVF 612602 10871112 0.273 0.273 780 12.0 0 x 0V►NFIX st1 796 16.0 0 x 0 VinlFlx IQ- CA + wrightsoft® Right -Suite® Universal 201717.0.14 RSU08101 k Ca1cslDocumentslWYNNE 2017-Apr-10 17:19:29 -THE WINDSOR-REVISED.rup Calc = MJ8 Front Door (aces: N Page 1 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft). Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft' 2017-Apr-1017:19:29 Lw� 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ..k CaicslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N