Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE4 SCANNED FORM R405-2014 BY FLORIDA ENERGY EFFICIENCY CO��'P6W9 ILDING CONSTRUCTION ,Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE-GEMINI Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PI CE , FL , Owner: �J\ Permit Number: Jurisdiction: Design Location: FL, Fort Pierce County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1774.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1550.30 ft2 b. Frame - Wood, Adjacent R=11.0 224.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 10. Ceiling Types (1839.0 sqft.) Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1839.00 ft2 6. Conditioned floor area above grade (ft2) 1839 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. R= ft2 11. Ducts R ft2 7. Windows(152.2 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 200 a. U-Factor: Dbl, U=0.63 134.42 ft2 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 17.78 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.051 ft. Area Weighted Average SHGC: 0.245 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1839.0 sqft.) Insulation Area EF: 0.970 a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 51.68 PASS Total Baseline Loads: 52.96 I hereby certify that the plans and specifications covered by Review of the plans and O� 041E ST,q?� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. nnrr'°. '-:='••:.•�� a O PREPA RED BY: DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 * °_ I hereby certify that this building, as designed, is in compliance the Florida Energy Code. Florida Statutes. COD with WE'T¢� OWNER/A T' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. F 1 717 ►arisaa � 12/14/2017 7:29 PM EnergyGauge@) USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: WYNNE-GEMINI Bedrooms: 1 Address Type: Street Address Building Type: User Conditioned Area: 1839 Lot # Owner: Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 135 Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE V IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1839 15581.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 No 0 1 No Yes Yes 5 MASTER BEDROO 256 2048 No 0 1 Yes Yes Yes 6 ENTRY 83 664 No 0 1 Yes Yes Yes 7 LAUNDRY 42 336 No 0 1 Yes Yes Yes 8 GREAT/DINING 568 5055 No 0 1 Yes Yes Yes 9 CLOSET 2 56 526 No 0 1 No Yes Yes 10 BATH 2 48 451 No 0 1 Yes Yes Yes 11 POWDER 42 395 No 0 1 No Yes Yes 12 SITTING ROOM 110 1034 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 43 ft 0 343 ft2 -_-- 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio MASTER BEDRO 51 ft 0 256 ft2 ---- 0 1 0 12/14/2017 7:29 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Valu , Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 83 ft2 U ,'• tp �— 0 • 7 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ____ ,) 11 0 G rVrt 8 Slab -On -Grade Edge Insulatio GREAT/DINING 39 ft 0 568 ft2 ---- 0 1 0 St. Lucie 9 Slab -On -Grade Edge Insulatio CLOSET 2 1 ft 0 56 ft2 ---- wrju fA FL 0 10SIab-On-Grade Edge Insulatio BATH 2 8 ft 0 48 ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulatio POWDER 1 ft 0 42 ft2 ____ 0 1 0 12Slab-On-Grade Edge Insulatio SITTING ROOM 22 ft 0 110 ft2 ---- 0 1 0 ROOF V Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1938 ft2 306 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1839 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft2 0.1 Wood 5 Under Attic (Vented) MASTER BEDRO 30 Blown 256 ft2 0.1 Wood 6 Under Attic (Vented) ENTRY 30 Blown 83 ft2 0.1 Wood 7 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 8 Under Attic (Vented) GREAT/DINING 30 Blown 568 ft2 0.1 Wood 9 Under Attic (Vented) CLOSET 2 30 Blown 56 ft2 0.1 Wood 10 Under Attic (Vented) BATH 2 30 Blown 48 ft2 0.1 Wood 11 Under Attic (Vented) POWDER 30 Blown 42 ft2 0.1 Wood 12 Under Attic (Vented) SITTING ROOM 30 Blown 110 ft2 0.1 Wood WALLS, Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S=>NW Exterior Concrete Block - Ext InsiHEDROOM 4.1 29 0 8 0 232.0 ft2 0 0 0.5 0 2 W=>NE Exterior Concrete Block - Ext InsfiIEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 3 S=>NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 _ 4 N=>SE Exterior Concrete Block - Ext InEMASTER BE 4.1 24 0 8 0 192.0 ft2 0 0 0.5 0 12/14/2017 7:29 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 10 Wall Typepace SOrnt 'lie Et In Pt In Area R-1/aIlle Erartoon AhSor Grarle% 5 E=>SW Exterior Concrete Block - Ext InEIIAASTER BE 4.1 13 0 8 0 104.0 ft2 0 0 0.5 0 + 6 S=>NW Exterior Concrete Block - Ext InEI1AASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.5 0 7 E=>SW Exterior Concrete Block - Ext Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 8 S=>NW Exterior Concrete Block - Ext Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.5 0 9 S=>NW Exterior Concrete Block - Ext InsLIIAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.5 0 10 N=>SE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 30 0 8 11 267.5 ft2 0 0 0.5 0 11 W=>NE Exterior Concrete Block - Ext InsGREAT/DINT 4.1 9 0 8 11 80.3 ft2 0 0 0.5 0 12 N=>SE Exterior Concrete Block - Ext Insul BATH 2 4.1 8 0 9 5 75.3 ft2 0 0 0.5 0 13 N=>SE Exterior Concrete Block - Ext InsSITTING RO 4.1 10 0 9 5 94.2 ft2 0 0 0.5 0 14 S=>NW Exterior Concrete Block - Ext InsSITTING RO 4.1 1 0 9 5 9.4 ft2 0 0 0.5 0 15 W=>NE Exterior Concrete Block - Ext InsSITTING RO 4.1 11 0 9 5 103.6 ft2 0 0 0.5 0 _ 16 N=>SE Garage Frame - Wood BEDROOM 11 28 8 224.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W=>NE 2 Metal Low-E Double Yes 0.63 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 2 S=>NW 3 Metal Low-E Double Yes 0.63 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 3 E=>SW 5 Metal Low-E Double Yes 0.63 0.25 32.4 ft2 1 ft 0 in 1 ft 4 in None None 4 N=>SE 10 Metal Low-E Double Yes 0.63 0.25 37.5 ft2 1 ft 0 in 1 ft 4 in None None 5 W=>NE 11 Metal Low-E Double Yes 0.65 0.21 17.8 ft2 10 ft 0 in 1 ft 4 in None None 6 N=>SE 12 Metal Low-E Double Yes 0.63 0.25 6.9 ft2 1 ft 0 in 1 ft 4 in None None 7 W=>NE 15 Metal Low-E Double Yes 0.63 0.25 18.4 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 384 ft2 28 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000377 1817.8 99.79 187.68 .2751 7 12/14/2017 7:29 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply --- -- Return ---- Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 40 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan He H Feb Jan H Feb Mar Mar HX Apr Jul Ma X Jun ri iI Jun Jul Au Aug rl Se Sep ri Oct Oct Nov Nov Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/14/2017 7:29 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 y FORM R405-2014 TABLE 402.4.1. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE-GEMINI Builder Name: WYNNE DEVELOPMENT Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 12/14/2017 7:29 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEV., FT. PIERCE, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1550.30 ftz b. Frame - Wood, Adjacent R=11.0 224.00 ft 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 1 d. N/A R= ftZ 10. Ceiling Types Insulation Area 5. Is this a worst case? Yes a. Under Attic (Vented) R=30.0 1839.00 ftz 6. Conditioned floor area (ftz) 1839 b. N/A R= ftz 7. Windows- Description Area c. R= z a. U-Factor: Dbl, U=0.63 134.42 ftz 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft z 6 200 SHGC: SHGC=0.25 b. U-Factor: Dbl, U=0.65 17.78 ftz SHGC: SHGC=0.21 12. Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a. Central Unit 34.8 SEER:15.00 SHGC: d. U-Factor: N/A ftz 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average Overhang Depth: 2.051 ft. Area Weighted Average SHGC: 0.245 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1839.00 ft z a. Electric EF: 0.97 b. N/A R= ftz c. N/A R= ftz b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. sr-,,r Builder Signature: Date: Address of New Home: �'� 2,J City/FL Zip: �(,Q ��D WE %) *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 12/14/2017 7:29 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1