+�- wrightsoft° Project Summary SCANNED Entire -House BY QUICK CALLS, INC. St Lucie County, 317 ST.-LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796. Email: QUicKCALCS@A0L For: THE GRAND CARLTON WYNNEEDDEVELOPMENT, FT. PIERCE,.FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Job: Date: By: Summer Design Conditions 42 OF Outside db . 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 17848 Btuh Ducts 5654 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 He 1446 Co 1446 Area ft Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 94 48 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency 8.5 HSPF Heating Input Heating output 34600 Btuh @ 47°F Temperature rise 27 OF Actual air flow 1160 cfm . Air flow factor 0.049 cfm/Btuh Static pressure 0.50 in H2O Space thermostat Capacity balance point = 32 OF Backup: Input = 7 kW,, Output = 23009 Btuh, 100 AFUE 90 OF 75 OF 15 OF 50 % 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 17520 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Equipmenf sensible load 24753. Btuh .Latent Cooling Equipment Load Sizing Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5521 Btuh Equipment total load 30274 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B;F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440. Btuh Total cooling 34800 Btuh Actual air flow 1160. cfm Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 2017-Apr-11 09:29:38 104CCk Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N - wrightsok Right-JO Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft ' 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ftz 297.0 ftz Ty Construction number U-value (Btuh/ftz-°F) Or HTM (Btuhlftz) Area (ftz) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4acs; _ "'. ,4A5 tom Oc143 0;770 :n` n- : 4:00: 21;56 2,55 . 19 31. 503 . 38 465 A. 1862 815 .. ,- 1184' 730 . 72 . 0 72., 0, 288, ;0 983 0 13A4ocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 IA-c1om 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 I--D 11 11D0 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 _ W i13A4ocs 0:143 se 4.00 2.55 34 34 136 86 0 0 -0 0 . y/ 13A-4ocs 0.143 s 4.00 2.55 36D 353 1414 899 216 216 865 550 1Aclom 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 _.G ,1A�c1om 4 • w 40 :2.55 0 237 949 603 04 72 :289 183 �613A-s 1.270 : w 35.56 55.21 32 : 2 1140 1770 32 2 1140. 1i70. ,4A5r2om :. .6.716 w -21.56 - 19.31 41 . 41 880..:. 788 0-- 0.. 0 0 P 12C-0sw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C . i 10A-30md '0 032 - _ 0:90' :. . 2.32 1446 1446 1295 : 3354 297'- 297' ''689 F 22A-tpl 0.989 .- 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation' 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 20M 0 Subtotal Qines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% =41 8536 32% 49% 1601 2400 FTotal room load 23503 26056 6653 7325 Air required (cfm) 1160 1160 328 326 Calculations . A 4+11- wrightsoft' ; Right -Suite® Universal 2017 17.0.14 RSU08101 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: 2017-Apr-11 69:29:38 Page 1 - wr ghtsoft° RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@t AOL.COM 1 Room name WIC KITCHEN 2 F�q�osed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 9.0 ft 54.0 ft2 1.0 x 172.0 ft 172.0 ft2 Ty Construction number U-value (Btuh/ft'L°F). Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A flocs •` ;4A5 tom . 13AAocs l).143 :-0.770 0.143 ~n. " h" a 4,00; 21.56 4.00 2.55 19.31 2.65 0 0 0 0 0 .0 0 :. 0 0 .. .. 0 . .. p 0 , p 0 0 . .0 , - 0 0 : 0 .. :0- 0 " :0 , 6 0 11 IA-c1om 11D0 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W.. . V+/ Y-C ;13AAocs 13AAocs 0:143 0.149 se. s 4.00 4.00 2.55 2.55 0 0 0 0 0.- 0 0 0 0 0 0 0 0 0 0 0 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 V�{J-� 13A11ocs 9Ac1om - 0.143 1.270 w .w 4.00 35.56 2.55 • 55:21 0 0 0 0 0 0 0 0 0 0 0 0 0.. 0 0 0 12C-0sw 16A 30rtidc ".' 22A-tpl -0.770 0.091 0:032 0.989 .w - '= - 21.56. ' 2.55 ' A.:90 27.69 19.31 1.28 232. 0.00 0 0 54 54 0 0 54 0 0 0 . 48 0 0 0 . 125 0 0 64 .. 172 172. 0. 64 172 0 0 163 154. 0 0 82 , '.399 0 P C F 6 c)AED excursion 79 -170 Envelope loss/gain 48 117 317 311 12 a) infiltration 0 6 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less extemal load 0 0 "0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 11.7 317 2311 151 Duct loads 32% 49% 15 57 32% 49% 100 1126 Total room load 64 174 1 1 418 3437 Air required (cfm) 1 3 8 21 153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A& -�. wr7ghtsoit' . Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr=11 0 Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJB Front Door faces: N - wrilghtsoft- Right-M Worksheet Job: Entire House Date: QUICK CALLS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name BATH BEDROOM 2 2 E)q)osed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ft2 1.0 x 203.5 ft 203.5 ft2' Ty Construction U-value Or HTM Area (ft2) Load Area (ft� Load number (Btuh/ft2L°F). (Btuhlft2) or perimeter (ft) (Btuh) or, perimeter. (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 :yJ L-L' 13A-0ocs - - 4A5 2om.: 0.143 0.770 n ": .n 4[00 21 5fi 255 19;31 40 . 0 40 0 160 0 . 102 0 128 0 - 128 ' 0 :. 513 .' 326 13A-4ocs 0.143 a 4.00 2.55 0 0 0. 0 80 56 225 143 11 1Ac1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 w T-G ,•13A-4bcs 13A4ocs 1A-c1om 0.143 0.143 1.270 se s s .4.00 4.00 35.56 2.55 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 34 32 0 34 32 0 136 128 0 86 81 0 13A4ocs ' 1A�1om _4A52om 12C-0sw. 16A:36md- :: .0.143 1i270 0i770 0.091_ 0.032 w w :w" ,- - - 4.00 35.56 21:56 2.55 - 0.90 2.55 55.21 . 19;31 1.28 Z32 0' 0, - 0 0 45: 0 0 -0 0 45 0 0 U 0 40 .0 0 0' 0 104 0 0 U'. 0 - :. 204 0 0 0: 0 204 . '0, 0, 0: 0 : 182: 0 0 0: 0 '_ 472 P C F 22A-tpl 0.989 - 27.69 0.06 45 5 138 0 204 34 946 0 6 c)AED excursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 01 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct oa 1 32% 1 490/o 135 104 32% 49% 1131 1704 Total room load I I 1 560 318 1 4702 5203 Air required (cfm) 28 14 232 232 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -- wrightsoft, 2017-Apr-11 09:29:38 �eA Right -Suite@ Universal 2017 17.0.14 RSU08101 Page.3 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJB Front Door faces: N - - wrightsoft Right ® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 3 Exposed wall Room height 6.0 ft 8.0 ft heat/cool 47.0 ft 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btu 2) Area (ft2) or perimeter (ft) Load (Btuh). Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool j Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 •V►/ G. 13A�ocs - . '4A5 tom; "• 13AAocs Oi143 0 770 0.143 n ": n; a 4:00 21;56 4.00 255 19:31. 2.55 0 6 0 0 0 0 0 0 0 `. 0 0 0 255 . 38 0 .:. 217. - 0 0 869 : 815 0 :552 730: 0 11 1Ac1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W. yJ �G 13A-46cs 13AAocs 1Ac1om 0143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 0 48 0 0 48 0 .0 192 0 0 122 0 0 0 0 0 0 0 0 0 0 0 0 0 v{�-� �-c 13A�1ocs : 7Ac1om 0.143 1.270 w , .w 4.00 35.56 2.55 55.21 0 0 .0 0 0 0. 0 0 206 0 165 .0 661 0, 420 0 ,4A5 tom; 12C-0sw 0770 0.091 : w. - -21.56 2.55 19:31 1.28 0 56 0 56 .. 0 143 . .0 72 41 0 41 0 880' .0 ... 788 0 • P '0 032 =. � = 0.90 : 2.3.2 42 42 _ 38 . 97 526 . 526 . 47,f .; - . 1220 F 22A-tpl 0.989 27.69 0.00 42 6 166 0 526. 47 1302 0 6 c) AED excursion -22 668 Envelope loss/gain 539 276 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 32% 49% 1899 2490 Total room load 846 443 7892 7602 Air required (cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements Of Manual J 8th Ed. 1 -- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 AMA, ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 4 wrightsoft° RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC.By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-0796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 Eq)osed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 50.0 ft 50.0 ft2 7.0 x 8.0 ft 56.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft22F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 M 4bc. ~=. :4A5 tom ', . 13A-4ocs 0143 0r770 0.143 :rt .. ri' . a 4:00' 29i56 4.00 2 55 19.3T 2.55 8 0 48 8 0 27 32 0 108 - 20 0 69 , 0 0 0 :. 0. - 0 0 0 0 p. 0 11 1A-clom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 W V!/ L-G 13A46cs 13A4ocs 0:143 0.143 se s 4.00 4.00 2.55 2.55 0 0 0 0 0. 0 0 0 0 64 0 57 0 228 0 145 1A-clom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13A�Iocs 1A c1om :_ .0.143 1.270 w, w 4.00 35:56 2.55 55:21 0 0 0 0 0 0. 0 0 0 0 .0 0 0 P_ C 12C-0sw 16A 30md' " Or770 6.091 0.'032 . ,w: - . - '_ 21:.56 2.55 0:90 . 49 31 _. 1:28 .. 232 r 0 72 50 : 0:-- 72 : 50 6 . 163 45 0 92 '. 116 : 0 0 - 56 ` 0: 0 .56. . 0'.. 0 .. 50 0. 0 . 130 F 22A tpl 0.989 - 27.69 6.00 50 7 194 0 56 8, 222 : 0 6 c) AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 885 516 Less extemal.load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32%1. 49% 280 251 Total room.load 1202 787 1 1166 768 Air required (cfm) 59 35 58 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 p� Page 5 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N -�- wrigho tsft® Duct System Summary pat Entire House By: • QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:.772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM Froject intormation For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL External static pressure Pressure losses Available. static pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating. 0.50 in H2O 0 in H2O .0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl . Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox 0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 OxO VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 OxO VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115..0 st1 M. BATH -A h 768 58 34 0 0 Ox0 VIFx 0 0 wlc c 174 3 8 0.309 4.0 Ox0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (In) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx htsoft' 9 wri Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-1109:29:38 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 1 Return Branch Detail Table Name Grille Size (in) Htg (cfm) clg (cfm) TEL (ft) Design FR Veloc (fpm) Qiam (in) H x W (in) Stud/Jdist Opening (in). Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx 2017-Apr-11 09:29:36 14 k. wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ..uick CalcsWocuments\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N