Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
- - wrightsoft- Project Summary Ent►re House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL,34046 For: Notes: Fax 772-466-6796 Email: SCANNED Job: Date: BY By: St Lucie County tUlCKCALCS AOL.COM. WYNNE DEVELOPMENT jTHE WINDSOR; FT. PIERCE, FL Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipmentioad Sizing Structure 18467 Btuh Structure 17655 Btuh Ducts 6190 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Use manufacturer's data n Rate/swing multiplier Equipmenf 0.95 Infiltration sensible load 25645 Btuh Method Simplified Latent Cooling Equipment1oad Sizing. . Construction quality Average Fireplaces 0 Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cool* Area (none) (W) 1753 175% Equipment latent load 5007 Btuh Volume (ft3) 14741 14741 Air changes/hour 0.38 0.20 Equipment total load 30652 Btuh Equiv. (cfm) 93 49 Req. total capacity at 0.70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 470F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual air flow. 1160 cfm Actualair flow . 1160 cfm. Airflow factor 0.047 cfm/Btuh Airflow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0:50 in H2O Space thermostat. Load sensible heat ratio 0.84 Capacity balance point = 34 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ACCP. + wrilghtsoft` Right2017-Apr-10 17:19:28 . Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N - wrightsoft' Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Exposed wall 153.0 ft 45.0 ft 3 Roam height 8.4 ft d 8.0 ft healfcool 4 Room dimensions 1.0 x 280.0 ft 5 Room area 1753.0 ft' 280.0 ftz Ty Construction U-value Or HTM Area s (ft-) Load number (Btuh/ft? °F) (Btuh!ft2 or perimeter (ft) (Load orperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 1 13A flocs 0.143 ne 4.00 165 488 448 1795 , 1141 . 192 .192 769 489 1A-Wri 1.270 ne 35.56 70:43 7 0 .247, 488 , • 0 0: :0 0 %c1om 1.270 ne 35.66 .. 70.43 16' 0 581 1151 0 0 0 0 :1A�1om 1.270 ne 35'56 45.24 18. 0 581 739 0 0 6' 11 y/ 13A-4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 �D 11DO 0.390 se 10.92 11.31 23 23 248 257 0 0 0 0, .f0& oc.s 0.1- : sw. m 2.55 ; 437 . - 396 1584 1007 56' 56 .- 224 - 143 G :4A5-2om 0.770 sw 21:56 . 27 53 41 45 893 1140 0 _. 0 • 0 16 13A4ocs 0.143 nw 4.00 2.55 290 217 867 551 112 .0 79 318 202 IA-c1om 1.270 nw 35.56 45.24 33 0 1162 1478 33 0 1162 1478 4AS-2omd 0.770 nw 21.56 36.90 41 0 880 1505 0 0 0 0 P ' ; :120--0sw D:091, - 2:55 1628 308 308 784 _ 395 0-. 0 0 ` 0 C 16A30md 0.032 - 0.90 2.32 1753 1753 1571 4067 280 280 251 6.0 :F 22A tpl '" 0.989 • - . 27.69 0.00 1753, 153 4237 0 286 -45 1246 ..' _ p 6 c) AED excursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal Qines 6 to 13) 18467 17655 4779 3789 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 34% 53% 6190 9340 34% 530/6 1602 2005 Total room load 24657 26995 6380 5794 Air required (cfm) 1160 1160 300 249 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A - - wrightsoft Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 8 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N wrightsoft Right-,J® Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@!AOL.COM Job: Date: By: 1 Room name WIC M. BATH 2 E)posed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ft2 61.0 ft2 Ty Construction U-value Or HTM Area (ft-) Load Area (ft2) Load number (Btuh/ft2--°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter O ft (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 A 13A4ocs 0.143 ne 4A0 2:65 " 0 0 0" 0 56 49 996 ' 125 IXcldm " 1.270 ne' 35l66 70i43 0 0 0 0 7 0 247 488 1 ,.clom 1.270 he 35:56 70.43 A 0 0 0.' 0: 0 0 0. 1Ac1om :. 1.270 ne 35:56 45.24 " 0 . 0 0. .0 0 0. 0 , 0. 11 Y-D 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11D0 0.390 se 10.92 11.31 0 0 0 0 0 0 0 0 13AAocs -. . .0:143 . sw - 4:00! 2:55 0 :., 0 - 0 . 0 0. • 0 " 0. 0.770 `sw•' 21:56' . 27.'M 0 6 0 0. .0 0 :0 ` '-0' V+/ 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 _'0 0 0 0 IA-clom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P 12C-0sw 0.091 - ' 2.55 . 1:28 _ 0 0 0 0 0 -0 0 - : 0 C 16ASOmd 0.032 - 0.90 2.32 63 63 56 146 61 61 . 55 142 :F : 22 tpl, : 0:980 - . 27.69 0.00 63 0 0 . 0, :61 7 194! : 0. 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal olnes 6 to 13) 56 141 817 764 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 34% 53% 19 75 34% 53% 274 404 Total room load 75 216 1091 1168 Air required (cfm) 4 9 51 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wF� rigtsoTt' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Pg a A&k e 2 ...k CalcslDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N 9 - - wrightsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: - 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUDRY BEDROOM 2 2 3 Eq)osed wall Room height 0 ft 8.0 ft heat/cool 12.0 ft 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ft2 15.0 x 12.0 ft 180.0 ft' Ty Construction number U-value (Stuh/ftz °F) Or HTM (Btuh/ftz) Area or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 . 13AAocs" 1Ac1om " IA;cldm 7A c1orrr 13AAocs 11D0 1�3A-flocs :. `4A5 tom . 13AAocs 1A-c1om 0.143 1.270 1.270 1:270 0.143 0.390 0.143 0770 0.143 1.270 : ne `ne: ne ne se se sw aw nw nw 4.00 35.56 36.56 35.56 4.00 10.92 4:00 21 i56. 4.00 35.56 2.55 . 70.43 . 70.43 45.24 2.55 11,31 2.55 27:53 2.55 45.24 0 0 ; 0 0 0 0 0 : 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1) 0 0 0 0 . 0 0 0 0 0 0 0 0 0 0 0 0 0 0 96 0: 16 0 0 0 . 0 0 0 0 80 0. 0 0 0 0 ; " � :0 ` 0 0 0 . 319 0. 581 0 0 0 . 0 ". . " :.0 0 0 203 0 1151 0 0 0 -0, ; 0 0 0 y✓ -D 14. 4A5-2omd 12C-0sinr 16A-30md 0.770 0:091 0.032 nw .- - 21.56 2c55 0.90 36.90 -1:28 2.32 0 . 0 36 0 0 36 0 0 32 0 0 84 0 0 180 0 0 180 0 0 161 0 0 418 P C F 22A tpl.: _ 0.989. - : 27.69 0.00 36 0 0 : 0 180- 12 332 '. - 0 6 c)AED excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 %15 1786 15 Duct loads 1 34% 53% 13 0 34o�a W% mi M Total room load 51 145 2156 2730 Air required (cfm) 2 6F 101 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. L`A 410- wrighirsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 3 k Calcs1Document6\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N AL FF wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name DINING/GREAT ROOM KrrCHEN 2 Ecposed wall 50.0 ft 11.0 ft 3 Room height 8.9 ft heat/cool 8.9 ft heat/cool 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft2 209.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ftZ- °F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 -, 13A-0ocs 0:143 ne 4.00 _ 2,55 0 0 0 0 0. 0 0 0 Xo6m ' - ' ' 1:270 'ne ' 35 56 70.43 0 0 0 0 ° 0 9 0 0 1A clom 1.270 ' ne 35.56 70.43 0 0 0. 0 0 0 0 0 1Ac1om . 1.270' nee 3556 45:24 0 0 0 0 0 0 0 0 11 V�/ 13AAocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 I-D 11DO 0.390 se 10.92 11.31 0 0 - 0 0 0 0 0 0 y/ 13A-0ocs '4A5.20m 0.143 - sw 4:00 2.55 267 226 903 574 98 392 - 249. L-G' 0:770 • sw 21.56 , 27:53 41 22 893 ; 1140 0 .98 0 0 0 V{j1--� 13A4ocs 0.143 nw 4.00 2.55 178 137 549 349 0 0 0 0 :::2 1Ac1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5.2omd 0.770 nw 21.56. 36.90 41 0 880 1505 0. 0 0 0 P 12C-0sw- .. 0.091 .- 2:55 1:28 0 0 - 0 0 ° 116 • 116:• . .295 148 C 16A.90md 0.032 - 0.90 2:32 588 588 527 1364 209 - 209 187 485 0:989 . _.; 27.69 0.00 588 50 : 1365 ': ' 0 .: .209 1.1 3q5' 0 6 c)AED e:xursion 1004 _64 Envelope loss/gain 5136 5937 1179 818 12 a). Infiltration 1000 282 220 62 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 0 1000 Subtotal (lines 6 to 13) 6136 6679 1399 1880 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 15 Duct loads 34% 53"/0 2058 3541 34% 53% 469 995 Total room load 8200 10234 1867 2875 Air required (cfm) 386 440 88 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A Z5fi - wrightsoft' 2017-Apr-10 1 Right-Sufte® Universal 2017 17.0.14 RSU08101 Page 4 ... k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - - wrilghtsoft' Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH HALL 2 Exposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 6.0 ft 5 Room area 50.0 ft2 25.0 ft2 TY Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-`F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 bA-0ocs • : '.. 0.143 . ne ,. " , 4 00' . 2.5Q : 40 40 160 - 102 0 <0 0. ' 0 1Ao1om . ' 9.270 ne' . 35.56 70..43 0 .' . 0 . `. 0 D 0'- :0 0 . '0 1A c1om 1276 ne 35.56 70.43 . 0 0 0 0 0 .0 . 0 0' 1Ac1om . 1'.270 ne. 35.56. 45.24. 0 0 0 0 0. 0'.. 0 11 y! t-D 13AAocs 0.143 se 4.00 2.55 0 0 0 .0." 0 0 0 0 0 11DO 0.390 se 10.92 11.31 0 0 0 0 0 0. 0 0 13A�ocs, : 0.143 sw M 2:55 .. 0 0 .. 0 0 . 0 ; 0 0 0 4A5 tom ': 0.770 • sw 21.56 . 27:53 0 0 0.- 0 0 . . 0 0 0 13AAocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 1A-c1om 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A5.2omd 0.770 nw 21.56. 36.90 0 0 0 0 0 0 0 0 P: - .12C Ogw. . 0.091 - 2.55 .1.28 0 0 0 0 0- 0 . 0' 0 C 16A30md 0.032 - 0.90 2.32 50 50 45 116 25 25 22 58 %F 22A pl 0.989 - 27.60 0 00 50 5 138 : 0 :25 0 . 0 0 6 c)AED excursion -8 -2 Envelope loss/gain 343 210 22 56 12 a) Infiltration 90 25 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pins 6 to 13) 433 235 22 56 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 340/o 530/a 147 132 34% 53% 0 0 Total room load 586 381 0 0 Air required (cfm) 28 16 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigFhtsoft• 2017-Apr-10 17:19:28 .A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 :k Calcs\Documents\WYNNE-THE WIND SOR-REVI SED. rup Calc = MJ8 Front Door faces: N -- wrohtsoft° Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By: • 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name FOYER BEDROOM-3 sed l �m 9.0 ft 14.0 ft 3 h height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 92.0 ft 13.0 x 13.0 ft 5 Room area 92.0 ft2 169.0 ft' Ty Construction U-value Or HTM Area (ft2) Load number (Btuh/ft' °F) (Btuh/ft2) or perimeter (ft) (Btuh) or�pedmeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y✓ 13A-0ocs. 0.10 ne. 4.00 2.65 0 0 0 0 104 88 351 223 ;1A c1om ,' 1 270 ne>: 35 56 70 43 " 0 _ 0 0 . 0 `. 0 0 ,: . 0 = 0 1A�1om Tr270 ne:. 35.56; 7043 0 0 0 0'. 0. ;0 0 0' 7A clom 1.270 ne 35.56 A5.24 ' 0 . 0 0 .0 ` 16 0 581 M6 11 13A-4ocs 0.143 se 4.00 2.55 64 41 165 105 0 0 0 0 11D0 0.390 .se. 10.92 11.31 23 23 248 257 0 0 0 0 13A�ioos:: 0:143 'sw 4:00 2 55 - 8 8. 32 : 20 8 8 - 32' -20 4A5 tom 0770 sw. 21-56 2Z:53 0 U . 0 : 0 0 0 p . - 0 V�/ 13A flocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 {--G 1A clam 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 4A6.2omd 0.770 nw 21.56 36.90 0 0 0 0 0 0 0 0 P VC-0sw- 0.091 . == 2:55 .1:28 88 98. 224 113 104 104 - 265 14 C 16A-30md 0.032 - 0.90 2.32. 92 92 82 213 169 169 151 392 F 22/ktpt%` 0.989 - - 27.69 0i00 92 9 249 :' 0 169 14 -388 , A 6 c)AED excursion -25 -52 Envelope loss/gain 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1163 730 . 2020 . 1527 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1527 15 Duct loads 34% 53% 390 386 34% 53% 677 808 Total room load 1573 11 2697 2335 Air required (cfm) 73 8 48 127 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A= 2017-Apr-10 17:19:28 P. Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 ... k CalcslDacumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: N -�- wrightsoft Duct System Summary Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@10L.COM P • ject Intormation For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox 0 VIFx 19.5 115.6 st1 BEDROOM 2 c 2730 101 117 0.384 7.0 Ox0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox 0 VIFx 26.8 115.0 st1 DINING/GREAT ROOM c 3411 129 147 0.292 7.0 Ox 0 VIFx 36.5 135.0 st2 DINING/GREAT ROOM-B C 3411 129 147 . 0.371 7.0 Ox 0 VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 OxO VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox 0 VIFx 7.0 95.0 KITCHEN C 2875 88 124 0.366 6.0 OxO VIFx 21.8 115.0 st1 LAUDRY c 145 2 6 0.371 4.0 Ox 0 VIFx 19.9 115.0 stl M. BATH h 1091 51 50 0.282 6.0 Ox0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 1.50 124 0.273 6.0 Ox0 VIFx 48.4 135.0 st2 MASTER BEDROOM -A h . 3190 150 124 0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 wlc c 216 4 9 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx .� wri htsoft° 2017-Apr-1017:19:29 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 k CalcMDocuments\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft° 2017-Apr-9017:19:29 'I'm+ 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ..k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N