Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
TRUSS
t Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. RE: M11392 - 71 Carlton ith 8 ext garage MiTek USA, Inc. Site Information-'6904 Parke East Blvd. TamaI L 33 0-4115 Customer Info: Wynne Dev Corp Project Name: M11392 Model: 70 Carlton 3 Bedroo�i ear .cNNNE® Lot/Block: Subdivision: BY Address: unknown City: 'St. Lucie County State: FL St Lucie Cot�hty Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2014/TP12007 Design Program: MiTek 20/20 7.6 Wind Code: ASCE 7-10 [All HeighIl Wind Speed: 165 mph Roof. Load: 37.0 psf Floor Load: N/A psf This package includes 15 individual, Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name I I Date 1 1 T12151408 A 9/29/17 12 1 T12151409 1 All 1 9/29/17 13 1 T12151410 1 A2 1 9/29/17 14 1 T12151411 I A3 1 9/29/17 15 1 T12151412 1 A4 1 9/29/17 6 1 T12151413 1 A5 9/29/17 7 T12_151414 ATA__ 1 9/29/17 _� 18 1 T12151415 1 B� 1 9/29/17 J 19 1 T12151416 1 BHA 1 9/29/17 110 1 T12151417 1 GRA 1 9/29/17 1 I11 I T12151418 I J1 1 9/29/17 12 I T12151419 I J3 1 9/29/17 113 I T12151420 � J5 1 9/29/17 114 I T12151421 I J7 9/29/17 115 I T12151422 1 KJ7 1 9/29/17 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Chambers Truss. Truss Design Engineer's Name: Albani, Thomas My license renewal date for the state of Florida is February 28, 2019. FILE CU. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into. the overall building design per ANSI/TPI 1, Chapter 2. fill/',I .N S •'9�i��i o 39380 STATE OF :•41J i0 4.0 R k O. �\ Thomas A. Al6anl PE No.39380 MITek USA, Inc. FL Cert 8634 6904 Parke East Blvd. Tampa FL 33610 Date: September 29,2017 Albani, Thomas 1 of 1 Job Truss Truss Type 15 1ty Ply 71 CarNon lh 8 ext garage T12151408 M11392 A HIP i 1 Job Reference (optional) �,nanroe�s nuss, rou rroi - - - . I D:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-eMn24rwiIJ2MX1 icnckyfu_ncnliZOdPRb6h41yYptM r1-0 Q 6 10 14 9-0-0 14-11-0 20-2-13 26-0-0 28-1-2 35.0-0 36� 1-0-0 6-10-14 2� 5-11-0 5-3-13 5.9-3 2-1-2 6-10-14 1-0.0 4.00 FIT 4x8 = 2x3 I I 3x6 = 2x3 11 2x3 4 24 5 6 7 25 4x8 = 2x3 8 9 Scale = 1:61.9 17 16 15 14 13 12 3x5 = 3x4 = 3x6 _ 3x4 = 3x4 = 4x6 = 3x4 = 3x6 = 20-2-13 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.49 Vert(LL) 0.58 12-14 >416 240 TCDL 7.0 Lumber DOL 1.25 BC 0.75 Vert(TL) -0.92 12-14 >262 180 BCLL 0.0 Rep Stress Incr YES WB 0.26 Horz(TL) 0.11 10 n/a rVa BCDL 10.0 Code FBC2014TrPI2007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1015/0-8-0, 15=575/0-8-0, 10=1108/0-8-0 Max Horz 2=97(LC 7) Max Uplift2=-631(LC 8), 15=-333(LC 8), 10=-685(LC 8) Max Grav2=1015(LC 1), 15=596(LC 17), 10=1114(LC 18) 35-0-0 9-" PLATES GRIP MT20 244/190 Weight: 152 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc puffins. BOT CHORD Rigid ceiling directly applied or 6-6-14 oc bracing. FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2097/1237, 3-4= 1856/1112, 4-24=-2176/1325, 5-24=-2176/1325, 5-6=-2176/1325, 6-7=-2176/1325, 7-25=-2176/1325, 8-25= 2176/1325, 8-9= 2172/1285, 9-10� 2353/1375 BOT CHORD 2-17=-1062/1941, 16-17= 865/1738, 15-16=-865/1738, 14-15=-1124/2176, 13-14=-1046/2067, 12-13=-1046/2067, 10-12=-1188/2175 WEBS 3-17= 302/283, 4-17=-112/324, 4-15=-292/681, 5-15— 498/392, 8-12=-142/358 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=631, 15=333, 10=685. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 1010312015 BEFORE USE, Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �' a muss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Cartion ith 8 exi garage T12151409 M11392 Al SPECIAL 1 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MTek Industries, Inc. Fri Sep 29 09:54:48 201, Page 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-6YKRHBxK3cAD8BHoLKFBC5W?XBcelLsZgFrFclyYptL 1-0• 8-6-0 11-0-0 14-9.0 19-8-14 24-0-0 27-4-7 35-0-0 -0-0 8-6-0 2-6-0 3-9-0 4-11-14 4-3-2 3-4-7 7-7-9 6 3x8 = 4.00 12 5x6 = 2x3 15x6 = 3x4 = 4 20 5 6 21 7 13 12 3x5 = 5x8 MT18HS = 2.00 12 Scale = 1:62.9 3x12 = 10-" 14-91 24-6-8 35-0-0 10-M 4-9-0 9-9-8 10-5-8 Plate Offsets (XY)-- f2:0-0-2 Edgel 19.0-1-15 Edgel LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TO 0.57 Vert(LL) 0.72 11-12 >579 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.89 Vert(TL) -1.51 11-12 >279 180 MT18HS 244/190 BOLL 0.0 Rep Stress Incr YES WB 0.77 HOrz(TL) 0.42 9 n/a n/a BCDL 10.0 Code FBC2014ITP12007 (Matrix-M) Weight: 155lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-7-15 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-2-8 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1366/0-8-0, 9=1332/0-8-0 Max Harz 2=-1 17(LC 6) Max Uplift2=-834(LC 8), 9=-815(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2989/1742, 3-4=-2796/1682, 4-20= 2916/1774, 5-20=-2916/1774, 5-6= 2916/1774, 6-21=-4530/2576, 7-21=-4530/2576, 7-8= 5193/2889, 8-9=-5612/3215 BOT CHORD 2-13= 1521/2769, 12-13= 1301/2515, 11-12=-2065/3799, 9-11=-2968/5344 WEBS 3-13=-317/323, 4-13_ 238/414, 4-12=-330/649, 5-12=-262/236, 6-12— 1031/619, 6-11— 332/886, 7-11=-763/1479, 8-11=-395/407 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL14.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=834, 9=815. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MiTekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Carlton Rh 8 ext garage T12151410 M11392 A2 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL r •640 � A'+9 16 2C- " - i — ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-6YKRHBxK3cADBBHoLKFBC5WzKBb?IKkZgFrFciyYptL 1-0- 8-6-0 13-0-0 14.9-0 22-0-0 27-4-7 35-0-0 6.0 -0-0 8-6-0 4•fi-0 1-9-b 7.3-0 5.4.7 7-7-9 1-0-0 5x6 = 3x4 = 5x6 = 4.00 F12 4 20 5 21 6 12 3x4 = 5x8 = 4x5 = 2.00 F12 35-0-0 3x12 Scale = 1:62.9 Plate Offsets (X Y)-- f2'0-2-14 Edge) (8.0-1-15 Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Vdetl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.64 Vert(LL) 0.70 10 >600 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(TL) -1.14 10-19 >369 180 MT18HS 2441190 BCLL 0.0 Rep Stress Incr YES WB 0.84 HOfz(TL) 0.40 8 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight: 160 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-7-10 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=1366/0-8-0, 8=1332/0-8-0 Max Horz2=136(LC 7) Max Uplift2=-834(LC 8), 8=-816(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3004/1748, 3-4= 2812/1694, 4-20=-2493/1570, 5-20=-2493/1570, 5-21=-3293/1951, 6-21= 3293/1951, 6-7=-5114/2850, 7-8— 5625/3250 BOT CHORD 2-13=-1527/2783, 12-13=-1183/2322, 11-12=-1314/2540, 10-11=-1708/3355, 8-10— 3001/5355 WEBS 3-13= 346/350, 4-13= 308/539, 4-12= 296/568, 5-12=-767/515, 5-11=-418/924, 6-11=-392/253, 6-1 0=-1 159/2216, 7-10=-495/499 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=7011; L=35ft; eave=5ft Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate, capable of withstanding 100 lb uplift at Joint(s) except Qt=lb) 2=834, 8=816. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE 111I1-7473 rev. 10/0=015 BEFORE USE. Design valid for use only with Milek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a in= system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' prevent Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 6904 Parke East Blvd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPl1 Quality Criteria, DSB-89 and BCSI Building Component VA 22314. Tampa, FL 33610 Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria. Job Truss Truss Type Qty Ply Carlton ith 8 ext garage T12151411 M11392 A3 SPECIAL i 1 171 Job Reference (optional) Chambers Truss, Fort Pierce, FL r.o,+u s Aug 16 eu r r mi i art muu--, mu. y — 0-4.5, c, , . ye ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-3xSBityabEQxOVRBSkHfHWcL1?HcmG9r8ZKMhdyYptJ 1-0 8-6-0 15-0-0 20-D-0 24-6-8 27-4-7 35-0-0 6-0- -0- 8-6-0 6-6-0 0 4.6-5 2-9-15 7-7-9 -0-0 �1 O 4.00 FIT 5x6 = 4x4 = Scale: 3/16°-1' 14 13 3x6 = 2x3 II 5x6 = 3x12 = 2.00 12 20-" 0 to r Im O LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2014/TPf2007 CSI. TC 0.56 BC 0.93 WB 0.72 (Matrix-M) DEFL. in (loc) I/defl Ud Vert(LL) 0.72 11 >586 240 Vert(TL) -1.18 11-20 >357 180 Horz(TL) 0.43 9 n/a rVa PLATES MT20 MT18HS Weight: 160lb GRIP 244/190 244/190 FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-7-7 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-12 REACTIONS. (lb/size) 2=1364/0-8-0, 9=1334/0-8-0 Max Harz 2=155(LC 7) Max Uplift2=-834(LC 8), 9=-816(LC 8) FORCES. (lb) - Max Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3052/1733, 3-4=-2934/1743, 4-5=-2349/1415, 5-6=-2610/1602, 6-7= 2757/1637, 7-8=-5200/2923, 8-9=-5590/3202 BOT CHORD 2-14=-1525/2830, 13-14=-1525/2830, 12-13=-1091/2205, 11-12=-2608/4988, 9-11=-2954/5319 WEBS 4-14=0/283, 4-13=-746/496, 5-12=-282/657, 6-12= 285/598, 7-12=-2676/1489, 7-11=-956/1895, 8-11= 377/352 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 9 considers parallel to grain value using ANSVTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=834, 9=816. 9) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11-7473 rev. 10/03/2015 BEFORE USE Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not Bet a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, ereellon and bracing of trusses and truss systems, seeANSi/TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type ty Ply 71 Carkon iih 8 ext garage T121514t2 M11392 A4 SPECIAL 1 i Job Reference o tional ' k i d I F I S 29 09:54:51 2017 Pace 1 Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mire n ustries, nc. ri Se g _ ID:_kfiGCA6bx7J2Syl HDXFw7ye3KX-X70ZVDzDMXYo?eONOSoupkBWoPcvVfi?MD4vD3yYptl 1.0 8-6-0 14-9-0 17-0-0 8-0-0 24 6.8 27-4-7 36.0-0 6-0- -0-0 8-6-0 6-3-0 2-3-0 1-0-0 6-fi-8 2-9-15 7-7-9 -0-0 Scale: 3/16°=1' 4.00 12 5x6 = 4x6 = 16 15 4X8 2x3 I 5x8 = 3x12 3x6 = 2.00 12 8-6-0 14-9-0 18-0-0 24-6-8 35-0-0 8-6-0 63-0 33-0 6-6-8 10-5-8 Plate Offsets (X Y) - (2:0-0-10 Edqel f9'0-3-0 Edgel f11:0-1-15 Edgel LOADING (psf) SPACING- 2-0-0 CSL DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.56 Vert(LL) 0.78 13 >542 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.92 Vert(TL) -1.26 13-22 >333 180 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.96 Horz(TL) 0.46 11 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight: 172lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-7-7 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 8-14 REACTIONS. (lb/size) 2=1365/0-8-0, 11=1333/0-8-0 Max Horz2=-175(LC 6) Max Uplift2= 834(LC 8), 11=-815(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3042/1732, 3-4=-2359/1412, 4-5=-2303/1426, 5-6=-2334/1509, 6-7=-2154/1376, 7-8=-2314/1391, 8-9= 5195/2958, 9-10=-5237/2955, 10-11= 5582/3192 BOT CHORD 2-16=-1513/2819, 15-16=-1513/2819, 14-15= 991/2102, 13-14=-2654/5036, 11-13=-2944/5310 WEBS 3-16=0/288, 3-15=-724/464, 5-15= 272/266, 7-14=-136/409, 6-14= 292/605, 6-15=-293/403, 8-14= 3088/1750, 8-13= 937/1901, 10-13=-330/293 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) Ail plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 11 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection'(by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) except Qt=lb) 2=834, 11=815. 9) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERANCE PAGE M1I.7473 rev. 1010312015 BEFORE USE Design valid for use only wlih MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Carton ith 8 ext garage T12151413 M11392 A5 SPECIAL 16 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MiTek industries, Inc. Fri Sep 29 09:54:52 2017 rage 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-?Jax7Z_r6rgfdobZa9J7Mxhd4oyXEBQBbtpSlWyYptH y r,-0-0 8-6-0 i 14-9-0 ,71-0 24-6-8 27-4-7 35-0-0 $6-0-0 -0-0 8-6-0 6-3-0 2-9-0 7-0-8 2-9-15 7-7-9 1-040 Scale=1:61.8 4.00 r12 5x8 11 14 13 2x3 11 5x,0 = 3x12 = 3x6 = 2.00 12 LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.79 TCDL 7.0 Lumber DOL 1.25 BC 0.90 BCLL 0.0 ' Rep Stress Incr YES WB 0.61 BCDL 10.0 Code FBC2014frP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP M 31 `Except' 1-4,8-11: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 `Except' 6-12: 2x4 SP M 30 REACTIONS. (lb/size) 2=1365/0-8-0, 10=1333/0-8-0 Max Harz 2=179(LC 7) Max Uplift2=-834(LC 8), 10= 815(LC 8) DEFL. in (loc) 11defl Ud PLATES GRIP Vert(LL) 0.78 12 >540 240 MT20 244/190 Vert(TL)-1.5912-13 >265 180 MT18HS 244/190 Horz(TL) 0.43 10 n/a n/a Weight: 159 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 4-2-9 oc bracing. WEBS 1 Row at midpt 6-12 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3035/1734, 3-4=-2371/1407, 4-5=-2314/1421, 5-6=-2329/1492, 6-7= 5329/3094, 7-8=-5231/2969,8-9= 5273/2968,9-10=-5598/3190 BOT CHORD 2-14=-1515/2812, 13-14= 151512812, 13-21= 997/2050, 21-22=-993/2058, 12-22=-989/2072, 10-12= 2942/5328 WEBS 3-14=0/256, 3-13=-704/472, 6-13= 235/512, 6-12=-1924/3461, 7-12=-327/336, 9-12_ 308/278 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Bearing at joint(s) 10 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=834, 10=815. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek" Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/iPil Quality Criteria, DSB-89 and BC51 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Carlton ith 8 ext garage T12151414 M11392 ATA COMMON 5 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mi rek Industries, Inc. Fri Sep 29 09:54:53 201, Page 1 I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-TV8KKv?Tt9oW FyAm7tgMu9DvDCO DzgclgXZ0lyyYptG 1-0Q 8-4-0 12-11-0 17 6-0 22-1-0 26.8-0 35-0.0 $6-0-0 r1-0-0 8-4-0 4-7-0 4-7-0 4-7-0 4.7-0 8.4-0 1-0-0 �1 0 4.00 12 4x4 = Scale = 1:60.8 17 .- 15 -- -- 14 -- 12 4x5 = 2x3 I I 4x6 = 3x8 = 2x3 11 4x5 = 3x8 = 4x6 = LOADING (pst) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.38 Vert(LL) 0.29 14-15 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.55 Vert(TL) -0.76 14-15 >550 180 BCLL 0.0 Rep Stress Incr YES W B 0.48 Horz(TL) 0.15 10 n/a n/a BCDL 10.0 Code FBC2014rrP12007 (Matrix-M) Weight: 166 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-9-2 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-3-9 oc bracing, Except: WEBS 2x4 SP No.3 8-6-0 oc bracing: 14-15. REACTIONS. (lb/size) 2=1399/0-8-0, 10=1399/0-8-0 Max Horz2=179(LC 7) Max Uplift2=-775(LC 8), 10=-775(LC 8) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3164/1575, 3-4=-2677/1331, 4-5 2606/1342, 5-24=-2680/1409, 6-24=-2629/1432, 6-25= 2629/1432, 7-25=-2680/1409, 7-8= 2606/1342, 8-9= 2677/1331, 9-10= 3164/1575 BOT CHORD 2-17= 1366/2936, 16-17=-1366/2936, 15-16= 1366/2936, 15-26=-745/1961, 26-27=-745/1961, 14-27=-745/1961, 13-14=-1366/2936, 12-13=-1366/2936, 10-12=-1366/2936 WEBS 6-14= 459/928, 7-14= 264/197, 9-14= 531/397, 6-15= 459/928, 5-15=-264/197, 3-15=-531/397 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) 1 OO.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 1 O.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=775, 10=775. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING -Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIF7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for on Individual building component, not �� a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek� Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery• erection and bracing of trusses and truss systerps, seeANSi/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Insfifute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply 71 Carhon ith 8 ext garage T72151415 M11392 B COMMON 2 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 Mi f ek MdusU�as, i �„ �o� ��, , ,tea= ID:_kfiGCA6bx7j2SylHDXFw7ye3KX-xiiiYF?5eSwMs6lyhaMbRMm5gcogi6 'R2AIZgOyYptF 1-0- Q 8-3-5 14-0-0 17-6.0 21-0-0 26-8-11 35-0-0 VMf 1-0-0 8-3-5 5-8-11 3-6-0 5-8-11 8-3-5 1-0-0 �1 6 Scale = 1:60.8 4.00 12 3x6 = 3x4 = 2X3 11 3x6 = 3x4 = 3x4 = 3x6 = 2x3 11 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.26 Vert(LL) -0.11 14-15 >768 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.27 Vert(TL) -0.18 12-23 >938 180 BCLL 0.0 Rep Stress Incr YES WB 0.54 Horz(TL) 0.03 10 n/a n/a BCDL 10.0 Code FBC2014fTP12007 (Matrix-M) Weight: 149lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0. (lb) - Max Horz2=-179(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 2=-385(LC 8), 15= 440(LC 8), 14=-440(LC 8), 10=-385(LC 8) Max Grav All reactions 250 lb or less at Joint(s) except 2=625(LC 1), 15=822(LC 13), 14=817(LC 14), 10=625(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-854/407, 9-10=-854/407 BOT CHORD 2-17=-262l771, 16-17=-262f771, 15-16=-262/771, 13-14=-262/751, 12-13=-262l751, 10-12= 262l751 WEBS 3-17=0/269, 3-15=-708/485, 5-15= 291/268, 7-14� 291/268, 9-14= 708/485, 9-12=0/269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 385 lb uplift at joint 2, 440 lb uplift at joint 15 , 440 lb uplift at joint 14 and 385 lb uplift at joint 10. 6) "Semi -rigid pitchbreaks Including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII-7473 rev. 101032015 BEFORE USE Design valid for use only with MiTek®conneclors. This design is based only upon parameters shown, and Is for an individual building component, not �� a truss system. Before use, the building designer must verily the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing WeW Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Carhon hh 8 ext garage T72151416 M11392 BHA BOSTON HIP 1 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL r.ovu s mug i P 201 r M, I eR muusnros, I—. aga ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-PuG4laOjPm2DUGKBFltq_aJCbO4rRYxaHg27MryYptE 15-6-0 21-6-0 1.0. 7-0-0 9-6-0 11-6-0 13-6-0 1 -0 0 17-6-0 19-6-0 21-0.0 23-6-0 25-6-0 28-0.0 35-0-0 6-0. 1.0-0 7-0-0 2.0.0 2-0-0 6• 1-6-0 2-0-0 2-0-D 1-6-00-6- 2-D-0 2.0.0 2-6-0 7.0-0 Scale: 3/16"=1' TOP CHORD MUST BE BRACED BY END JACKS, 4.00 12 4X4 = ROOF DIAPHRAGM, OR PROPERLY CONNECTED PI — — DC CPFr.1F1Pn 35 33 ... ._ .. ._ 32 3x6 = 6x8 = 6x8 = 3X6 = 3x4 = 30 3x4 = 10-0 14-0-0 21-0-0 28-0-0 35-" 7-0-0 7-0-0 7-0-0 7-" 7-" Plate Offsets (X Y)-- f32:0-3-8 0-3-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.09 35-38 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(TL) -0.18 33-35 >953 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.62 Horz(TL) 0.04 28 n/a n/a BCDL 10.0 Code FBC2014ITP12007 (Matrix-M) Weight: 208 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-6-13 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32 JOINTS 1 Brace at Jt(s): 11, 19, 16, 7, 23 REACTIONS. All bearings 0-8-0. (Ib) - Max Harz 2=179(LC 7) Max Uplift All uplift 100 lb or less at joint(s) except 2=-579(LC 8), 33=-1255(LC 8), 32= 1005(LC 8), 28=-446(LC 8) Max Grav All reactions 250 Ito or less at joint(s) except 2=833(LC 17), 33=1803(LC 1), 32=1510(LC 1), 28=646(LC 1) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-52=-1607/1042, 3-52=-14411984, 3-53=-108/258, 27-63=-906/619, 28-63=-1056/658, 3-5= 439/531, 5-7=-433/524, 7-10— 433/524, 10-11=433/524, 11-13=-433/524, 13-14_ 433/524, 14-16=-433/524, 16-18= 433/524, 18-19— 433/524, 19-21=-378/423, 21-23=-378/423, 23-25=-378/423, 25-27=-383/429 BOT CHORD 2-35— 880/1473, 3542= 855/1390, 4243=-855/1390, 34-43=-855/1390, 3444=-855/1390, 33-44=-855/1390, 33-45=-386/402, 45-46=-386/402, 46-47=-386/402, 47-48=-386/402, 32-48=-386/402, 32-49=-525/923, 31-49=-525/923, 31-50=-525/923, 50-51=-525/923, 30-51=-525/923,28-30=-514/952 WEBS 3-35=-168/626, 27-30=0/430, 3-33=-1994/1462, 11-33=-815/786, 19-32=-777/748, 27-32= 1400/992, 9-10=-465/455, 20-21= 464/455 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft B=70ft; L=3511; eave=6ft Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tail by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 579 Ib uplift at joint 2, 1255 ib uplift at joint 33, 1005 lb uplift at joint 32 and 446 lb uplift at joint 28. 8) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 9) Graphical pudin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord. Continued on page 2 ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MTFEK REFERANCE PAGE MII.7473 rev. 10/03J2015 BEFORE USE Design valid for use only with MITek® connectors. This design is based only upon parameters shown. and Is for an Individual building component not �' a truss system. Before use• the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing 6VliTW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems. seeANSi/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Carhon ith 8 ext garage T12151416 M11392 BHA BOSTON HIP 1 1 Job Reference (optional) Chambers Truss, Fort Pierce, Fl- i.oyo s —W . - H A H.M. I -, ov ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-PuG41a0lPm2DUGK8Fltq_aJCb04rRYxaHg27MryYptE NOTES- 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 (b up at 7-0-0, 158 lb down and 206 lb up at 9-0-12, 158 Ib down and 206 Ib up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 1581b down and 2061b up at 15-0-12, 156 lb down and 206 Ib up at 17-0-12, 158 lb down and 206 Ib up at 17-11-4, 158 lb down and 206 lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 Ib down and 206 Ib up at 25-11-4, and 158 lb down and 206 lb up at 27-11-4 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, 69 lb down at 11-0-12, 69 lb down at 13-0-12, 69 Ib down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at 19-11-4, 69 lb down at 21-11-4, 69 lb down at 23-11-4, and 69 lb down at 25-11-4, and 69 Ib down at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 36-39= 20, 1-3=-54, 3-15= 54, 15-27=-54, 27-29=-54 ConcentratedLoads (lb) Vert: 35=-373(F) 30=-23(F) 42_ 23(F) 43= 23(F) 44= 23(F) 45=-23(F) 46=-23(F) 47=-23(F) 48=-23(F) 49= 23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53=-118(F) 54=-118(F) 55= 118(F) 56=-11B(F) 57=-118(F) 58=-11B(F) 59=-118(F)60=-118(F) 61=-118(F) 62=-118(F) 63=-118(F) A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. 1010312015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use. ]he building designer mast verify the applicabhity, of design parameters and properly Incorporate this design Into the overall building design. Bracing indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Sulte 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Carkon ith a ext garage T12151417 M11392 GRA HIP 1 1 Job Reference (optional) cnamoers truss, ron rierce, M ,. , ..,.. . - ..._.... -- _-.-..-- __.. . ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-t4pSzw1 LA4A46QuLp?03W nrHtQO_AvEkW UnguHyYptD 1-0 7.0.0 14-11-0 21.5.2 28-0-0 35-0-0 36-0-0 -0-0 7-0-0 7-11-0 6-6-2 6-6-14 7-0.0 -0-0 �d 6 4.00 12 5x8 = 3 22 23 2x3 11 3x6 = 3x6 = 4x8 — 24 25 4 26 27 5 28 629 30 31 32 7 Scale = 1:61.8 33 U4 14 JO 6x10 = JO Jr J8 ou 1. Iry vi 3x4 = 2x3 11 3x6 = 3x4 = Us = 2x3 II 3x5 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TO 0.94 Vert(LL) 0.21 10-12 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.26 BC 0.67 Vert(TL) -0.39 10-12 >623 180 BOLL 0.0 Rep Stress Incr NO WB 1.00 Horz(TL) 0.11 8 n/a n/a BCDL 10.0 Code FBC2014/TPI2007 (Matrix-M) Weight: 153 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-1-10 oc puffins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-11-6 oc bracing. WEBS 2x4 SP No.3 `Except` WEBS 1 Row at midpt 3-13, 6-13 4-13: 2x6 SP No.2 REACTIONS. (lb/size) 2=774/0-8-0, 13=3177/0-8-0, 8=1246/0-8-0 Max Horz2=78(LC 7) Max Uplift2=-516(LC 8), 13=-1909(LC 8), 8= 799(LC 8) Max Grav2=778(LC 17), 13=3177(LC 1), 8=1246(LC 18) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1467/855, 3-22=-747/1318, 22-23=-747/1318, 23-24=-747/1318, 24-25=-747/1318, 4-25=-747/1318, 4-26=-747/1318, 26-27=-747/1318, 5-27=747/1318, 5-28=-747/1318, 28-29=-747/1318, 6-29=-747/1318, 6-30=-1920/1225, 30-31= 1920/1225, 31-32=-1920/1225,7-32=-1920/1225,7-8=-2869/1716 BOT CHORD 2-15=-723/1342, 15-33=-732/1382, 33-34=-732/1382, 14-34= 732/1382, 14-35=-732/1382, 13-35=-732/1382, 13-36=-1107/1920, 36-37=1107/1920, 37-38=-1107/1920, 12-38=-1107/1920, 12-39=-1524/2706, 11-39=-1524/2706, 11-40=-1524/2706, 40-41 =-1 524/2706, 10-41= 1524/2706, 8-1 0=-1 513/2668 WEBS 3-15=-155/711, 3-13=-2806/1663, 4-13=-848/795, 6-13=-3446/2082, 6-12=-87/648, 7-12=-835/507, 7-10_ 177/660 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 516 lb uplift at joint 2, 1909 lb uplift at joint 13 and 799 lb uplift at joint 8. 7) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. Continued on page 2 ® WARNING- Verily design parameters and READ NOTES ON THIS AND INCLUDED MFTEK REFERANCE PAGE MJI-7473 rev. 1010312015 BEFORE USE Design valid for use only with MITek6 connectors. This design Is based only upon parameters shown. and Is for an Individual building component, not � a truss system. Before use. the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information avallabie from Truss Plate Institute. 218 N. Lee Street, Suite 312, Alexandria. VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty ilh 8 ext garageT12151417 M11392 GRA HIP 1 �PP17y71arhon Reference (optional) Gnambers truss, tort mercer hr. ,.vvva w iv cvi, rvni vn uiv vo, noo, .— . or. ... ... I D:_kfiGCA6bx7j2Sy1 H DXFw7ye3KX-t4pSzw1 LA4A46QuLp?03 W nrHfQO_AvEkW UnguHyYptD NOTES- 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(S) 203 lb down and 329 lb up at 7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-11-4, 90 lb down and 155 lb up at 19-11-4, 90 lb down and 155 lb up at 21-11-4, 90 Ito down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-11-4, and 203lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 Ib down and 3 lb up at 9-0-12, 63 lb down and 3 lb up at 11-0-12, 63 lb down and 3 lb up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 Ito up at 17-0-12, 63 lb down and 3 lb up at 17-11-4, 63 lb down and 3 lb up at 19-11-4, 63 lb down and 3(b up at 21-11-4, 63 lb down and 3 lb up at 23-11-4, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-11-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads .(plf) Vert: 1.3=-54, 3-7==54, 7-9=-54, 16-19=-20 Concentrated Loads (lb) Vert: 3= 147(B) 7= 147(B) 15=-452(B) 13=-40(B) 4=-90(B) 10= 452(B) 22=90(B) 23=-90(B) 24=-90(B) 26=-90(B) 27=-90(B) 28— 90(B) 30=-90(B) 31=-90(B) 32= 90(B) 33= 40(B) 34=-40(B) 35= 40(B) 36=-40(B) 37= 40(B) 38=-40(B) 39= 40(B) 40=-40(B) 41=-40(B) Q WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MrrEK REFERANCE PAGE M11-7473 rev. 1010312015 BEFORE USE. Design valid for use only with NSTek® connectors. Tills deslgn Is based only upon parameters shown, and Is for an Individual building component, not �' IM a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type City Ply 71 Carton ith 8 ext garage T12151418 M11392 it MONO TRUSS 8 1 Job Reference (option 1 Chambers Truss, Fort Pierce, FL /.aqu s Aug i o 26i r Mr r ek inaunnes, mc. Fn oep cc ve.54.00 20F.U. . I D:_kfiGCA6bx7j2Sy1 H DXFw7ye3KX-t4pSzw1 LA4A46QuLp?03W nrUbQYHA8vkW UnguHyYptD -1.0-0 1-0-0 1-0-0 1-0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) -0.00 5 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.01 Vert(TL) -0.00 5 >999 180 BCLL 0.0 Rep Stress lncr YES WB 0.00 HOrz(TL) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014ITP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=10/Mechanical, 2=113/0-8-0, 4=4/Mechanical Max Horz 2=48(LC 8) Max Uplift3_ 5(LC 5), 2= 127(LC 8), 4=-2(LC 5) Max Grav3=11(LC 13), 2=113(LC 1), 4=11(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. Scale = 1:6.2 PLATES GRIP MT20 244/190 Weight: 5 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpl=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 5 lb uplift at joint 3, 127lb uplift at joint 2 and 2 lb uplift at joint 4. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MIfEK REFERANCE PAGE 1,111-7473 rev. 10103/2015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �' a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the 6904 Parke East Blvd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Carhon Rh 8 ext garage T72151419 M11392 J3 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 1-0-0 3x4 = 7.640 s Aug 16 2017 Mir ek Industries, Inc. Fri Sep 29 09:54:57 2017 rage 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-MHNgAG2zxNixkZTXMivl3?OtKpslvb9tl8XDRjyYptC Scale = 1:9.6 3-0-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/detl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) -0.00 7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(TL) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014[TP12007 (Matrix-M) Weight: 11lb FT=O% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=58/Mechanical, 2=184/0-8-0, 4=31/Mechanical Max Horz2=85(LC 8) Max Uplift3= 53(LC 8), 2= 149(LC 8), 4=-3(LC 8) Max Grav3=58(LC 1), 2=184(LC 1), 4=44(LC 3) FORCES. (lb) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 53 lb uplift at joint 3, 149 lb uplift at joint 2 and 3 lb uplift at joint 4. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII.7473 rev. 10/03/2015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the appllcabfllty of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTe'k' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information avallable from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Carlton fth 8 ext garage T12151420 M11392 J5 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Fort Pierce, FL 3x4 = "M s n 9 r o cu i i m i en i iuusuros, a c. eN �o ��.��.�. ga , ID:_kfiGCA6bx7j2SylHDXFw7ye3KX-MHNgAG2zxNlxkZTXMivl3?6b6Wp vb9tl8XDRjyYptC 5-0-0 5-0-0 Scale = 1:12.9 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) -0.02 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.28 Vert(TL) -0.04 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES W B 0.00 Horz( L) 0.00 2 n/a n/a BCDL 10.0 Code FBC2014fFP12007 (Matrix-M) Weight: 17lb FT=0% LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 REACTIONS. (lb/size) 3=100/Mechanical, 2=274/0-8-0, 4=47/Mechanical Max Horz 2=123(LC 8) Max Uplift3= 96(LC 8), 2= 194(LC 8) Max Grav3=100(LC 1), 2=274(LC 1), 4=75(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (ib) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=1511t; B=70ft; L=35ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 96 lb uplift at joint 3 and 194 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. A WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MTTEK REFERANCE PAGE MI17473 rev. 1010312015 BEFORE USE. � Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verity the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTeW Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabricatlon, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quallty Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street. Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply Carlton ith 8 ext garage T12151421 M11392 J7 MONO TRUSS 24 1 171 Job Reference (optional) 29 095457 2017 P 1 Chambers Truss, Fort Pierce, FL 7.640 s Aug 16 2017 MT ek Industries, Inc. Fri Sep age ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-MHNgAG2zxNlxkZTXMivl3?Od6pkbvbgtlBXDRjyYptC -11 0 7-0-0 1-0-0 7-0-0 Scale = 1:16.5 3x4 = 7-0-0 7-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.25 Vert(LL) -0.06 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.58 Vert(TL) -0.16 4-7 >520 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.01 2 n/a n/a BCDL 10.0 Code FBC2014/TP12007 (Matrix-M) Weight: 23 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 3=144/Mechanical, 2=365/0-8-0, 4=60/Mechanical Max Horz 2=161(LC 8) Max Uplift3= 140(LC 8), 2=-240(LC 8) Max Grav3=144(LC 1), 2=365(LC 1), 4=103(LC 3) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 3) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1401b uplift at joint 3 and 240 lb uplift at joint 2. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. WARNING - verily design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MII-7473 rev. 101=015 BEFORE USE. Design valid for use only with MITek® connectors. This design Is based only upon parameters shown. and Is for an Individual building component not o truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MOW Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB•89 and BCSI Building Component 6904 Parke East BNd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply 71 Carlton ith 8 ext garage T12151422 M11392 KJ7 MONO TRUSS 4 1 Job Reference (option 1 Chambers Truss, Fort Pierce, FL 7.640 a Aug 16 2017 MI I eK Incustrles, mc. Hi sep 28 U8:54:66 2017 rage 1 I D:_kfiGCA6bx7j2Sy1 H DXFw7ye3KX-gTxDNc3cihQoLj2jwQQXbCxp4DAAe?u1 zoGnz9yYptB -1-5-0 6-8-12 i 9-10-1 1_" 6-8-12 3-1-5 ' Scale = 1:21.1 3x4 = «� 5 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.03 7-10 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.24 Vert(TL) -0.07 7-10 >999 180 BCLL 0.0 ' Rep Stress Incr NO WB 0.22 Horz(TL) 0.01 5 n/a n/a BCDL 10.0 Code FBC2014fTP12007 (Matrix-M) LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 4=134/Mechanical, 2=392/0-11-5, 5=440/Mechanical Max Harz 2=192(LC 8) Max Upiift4=-133(LC 8), 2= 266(LC 8), 5= 232(LC 8) Max Grav4=161(LC 13), 2=392(LC 1), 5=442(LC 13) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-769/349 BOT CHORD 2-7=-469/746, 6-7— 469l746 WEBS 3-7=0/285, 3-6=-860/541 PLATES GRIP MT20 244/190 Weight: 38 lb FT = O% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft L=35ft eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 133 lb uplift at joint 4, 266 lb uplift at joint 2 and 232 lb uplift at joint 5. 6) "Semi -rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Veit: 1-2= 54 Trapezoidal Loads (pit) Vert: 2=0(F=27, B=27)-to-4=-133(F= 39, B=-39), 8=0(F=10, B=10)-to-5=-49(F=-15, B=-15) ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mil-7473 rev. 10703&015 BEFORE USE. Design valid for use only with MlfekO connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not �' a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate tits design into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Addiflonal temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI l Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Symbols PLATE LOCATION AND ORIENTATION 3/4' Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths, Apply plates to both sides of truss and fully embed teeth. 0-'/1 d' - -I- For 4 x 2 orientation, locate plates 0-1/0 from outside edge of truss. This symbol indicates the required direction of slots in connector plates. ` Plate location details available in Mii 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate Connected Wood Trusses, Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 2 TOP CHORDS 0 JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR- 1311, ESR- 1352, ESR 1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 Trusses are designed for wind loads in the plane of the truss unless otherwise shown. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: MII-7473 rev. 10/03/2015 ® General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, Individual lateral braces themselves may require bracing, or alternative Tor I bracing should be considered. 3. Never exceed the design loading shown and never stack materials on Inadequately braced trusses. 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1. 7. Design assumes trusses will be suitably protected from the environment In accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 1 W. at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Camber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions Indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and In all respects, equal to or better than that specified. 13. Top chords must be sheathed or purlins provided at spacing Indicated on design, 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15, Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless Indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front, back, words and pictures) before use. Reviewing pictures alone Is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.