Loading...
HomeMy WebLinkAboutPROJECT INFORMATION..1.N - wrightsoft® Project Summary Entire:House QUICK CALCS, INC. SCANNED BY Job: Date: St Lucie CoUrItY By: 317 ST. LUCIE LN., FT. PIERCE, PL 34946 Phone: 772466-6799 Fax 772-466-6796. Email: QUICKCALCS@AQL.COM � •Iect intormation For THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL 12 Notes: Design • • Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification' 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 24753. Btuh Infiltration sensible Method Simplified Latent Cooling -Equipment Load. Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Heat" . Coolingg (none) Area (ft2) 1446 1446 Equipment latent load 5521 Btuh Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh ' Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A!030 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 10440 . Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual, airflow 1160 cfm Actual air flow 1160 cfm . . Airflow factor 0.049 cfm/Btuh Airflow factor 0.045 cfm/Btuh Static pressure 0.5.0 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved rbyACCA to meet all requirements of Manual J 8th Ed. Wrl htso$` 2017-Apr-11 09:29:38 .► 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Pagel ,OCC` ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - wr ghtsoft' Right-M Worksheet Job: Entire House Date: - By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@!AOL.COM 1 Room name Entire House BEDROOM 2 Exposed wall 156.2 ft 49.0 ft 3 Room height 8.7 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ftz 297.0 ft' Ty Construction U-value Or HTM Area (ftz) Load Area (ft-) Load number (Btuh/ffl�°F) (Btuh/ft2) or perimeter (ft) (Btuh). or perimeter (ft) (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0ocs 0,143 n 4.00' 2.55 503 465 : ' • , 1862 - 1184 72' - 72 288 183 • ;4A5 tom ", 0:770 _. n •.% 21.56 19 W 38 0 815 730 . 0 0 ". .' 0 6 13AAocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 1A-clom 1.270 a 35.56 87.29 24 2 848 2082 0 0 0 0 1 11DO 0.390 a 10.92 11.31 21 21 229 238 0 0 0 0 W Vt/ �--G 93AAocs 13AAocs 0.143 0.143 'se s 4.00 4.00 2.55 Z55 34 360 34 353 136 1414 86 899 0 216 0 216 -0 865 0. 650 1Aclom 1.270 s 35.56 34.77 7 7 247 241 0 0 0 0 0.143 w 4.00 2.55 310 237 949 603 104 72 288 183 ��A13AAocs IA-clom 1.270 -. w 3556 65.21 32 2 1140 1770 32 2 1140 17Z0. W-2orn 0:770 : w 21.56 19.31 : 41 . 41 880 ::. 788 0 , - 0 . 0. 0 P 12C-0sw 0.091 - 2.55 1.28 192 192 489 246 0 0 0 0 C iTm 30md. ' 0 032 - 0:90 :. 2.32 1446 1446 1295 =' 3354 - . 297 '. : • 297 :. , . , 266' ` 689 F . 22A-tPl 0.989 -' 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal Qines 6 to 13) 17848 17520 5053 4925 Less extemal load 0 0 6 0 Less:transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 FTTotal room load 23503 26056 7 6653 7325 Air required (cfm) 11601 1160 328 326 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Aem wrights . . Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 8 ...ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N -F- wrightsoft Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC WCHEN 2 F�osed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 9.0 ft 54.0 ft2 1.0 x 172.0 ft 172.0 ft' Ty Construction LI-value Or HTM Area (ft2) Load Area (ft-) Load number (Btuh/ftz °F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gnus N/P/S Heat Cool Gross N/P/S Heat Cool 6 U 13A46cs;:. 0.143 n,. 4.00. -2.55 p p p , .. :.0 ,0.. .p p `.0. '4 k6in ' 0.770 n - . 21.56 19:31 0 " 0 • 0 0, 0 .:0. 0 p 13A4ocs 0.143 a 4.00 2.65 0 .0 0 0 0 0 0 0 -G 1A-c1om 1.270 a 35.56 87.29 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 11.31 0 0 0 0 0 0 0 0 W. ,13A4ocs 0.:143 se. 4.00 2.55 0 0 0.1 0 0 0 0 0 V�/ 13A4ocs 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 L--G 1A-c1om 1.270 s 35.56 34.77 0 0 0 0 0 0 0 0 13A-46cs 0.143 w 4.00 2.55: 0 0 0 .0. 0 0 0. 0 1Aclom - 1.270 w 35.56 55.21 0 0 0 0 0 0 0 0 m'6 4A5-2om .0.770 w 21.56 19.31 0 0 0 .0 0 0. 0 0 P 12C-0sw 0.091 - 2.55 1.28 0 0 0 0 64 64 163 82 C " 16A rrid::: 0.032 `- t0:90 2.32 ` .54:'. 54 _ 48 ;+ 125,.. • 172 172 154: 1 '. , .399 F 22A tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 01 2000 Subtotal Oines 6 to 13) 48 117 317 2311 Less extemM load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 32% 49% 15 57 32% 49% 100 1126 Total room load 64 174 418 3437 Air required (cfm) I 1 3 8 21 153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 44- wrightsoft' RightSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 Page 2 ...uick Calcs%Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N - - wrightsofta Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS @I AOL.COM 1 Room name BATH BEDROOM 2 2 F)q)osed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ft2 1.0 x 203.5 ft 203.5 ft2. Ty Construction number U-value (Btuh/Wt-°F): Or HTM (Btu ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat. Cool 8 13A 4ocsr. 4A5 tom • :' 0.143 0.770 n' rn ; 4:00 '2158 255 19;31 .:. • 40 0 40 - 0 160 . 0 ; . 102 0 128 ' 0 ,. 128'. 0 -513 . ' '0 326 ": 0 . V)I 13A4ocs 0.143 a , 4.00 2.55 0 0 0 0 80 56 225 143 11 L�-_Gp 1A-c1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 W 13A4ocs 0.143 se .4.00 Z55 0 0 0 0 34 .34 136 86 Y_G0.143 13A4ocs 1A-clom 1.270 s s 4.00 35.56 2.55 34.77 0 0 0 0 0 0 0 0 32 0 32 0 128 0 81 0 13A-0ocs 1A�.Mom . 4A5 tom 12C-0sw .0.143 1.270 0:770 0.091 w •..w ' w 4.00 35.56 2158 2.55 2.55 55.21 . 19 31 1.28 : 0 0 0 0 ,. 0 0 - 0 0 0 0 0 0 .0 0 0 0 0 0 0 0 0 .0 0 '0 0 0 0 0 0, 0 0 . P C _ ;:18A 30md ,- 0:032 _- - 0.90 Z32 45 . 45 40 104 ; 204 -204 ..._ `,182 472 F 22A tpI 0.989 - 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED exursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 01 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Less external load 0 0 0 0 Less .transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15I Duct loads 1 32%a 49%1 135 104 32% 49% 1131 1704 Total room load I 1 1 560 318 4702 5203 Air required (cfm) 28 14 1 232 232 Calculations approved byACCA to meet all requirements of. Manual J 8th Ed. 411- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 3 ...ulck Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N + wrightsoft' RighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING 2 Exposed wall 6.0 ft 47.0 ft 3 Room height 8.0 ft heat/cool 9.8 ft heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ftz Ty Construction U-value Or HTM Area (ft.) Load Area (ftz) Load number (Btuh(ftl�-"F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WPM Heat Cool 6 A G: *1 Aocs ' . `4AS.2om - 13A-4ocs 0.143 O:T/0 0.143 n' • ri'` a 4.00 2156 4.00 2 55 19:31: 2.55 0. 0 0 0 D 0 0 , 0 0 0 0 0 ., 255 . m 0 ; " 217, ` ` '0. 0 869 815 0 552 730 0 . 11 1Ac1om 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 t-D W tUdl 13A-4ocs 13A-4ocs IA-c1om 0.143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 255 34.77 0 48 0 0 48 0 0 192 0 0 122 0 0 0 0 0 0 0 0 0 0 0 0 0 -a 1�i13A4ocs 0.143- w 4'00 2.55 0 0 0 0 206 165 661 420 1A-clom 1.270, w 35.56. 55.21 0 0 0 0 0 0"0 -- 0 °4A5-26m , .0:770 w 21.56; : 1931 0 0 0 . .0. 41 : 41 ; 880 1._ .. 788 P 12C-0sw 0.091 - 2.55 1.28 56 56 143 72 0 0 .0 0 C :,16A 30md : ' 0 032 " - '0.90 : 232 42 42 _ 3li . 97 ;. - 526. " .. 526 . 471; .: ; , ,1220 F 22A tpl 0.989 - 27.69 0.00 42 6 166 0 526 47 1302 0 6 c) AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 15 Duct loads 32% 49% 204 145 49% 1 1899 2490 Total room load 846 443 1 7892 7602 Air required (cfm) 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J.8th Ed. �P. -�- wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page 4 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door Faces: N - wrightsoft° Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER M. BATH 2 Exposed wall 7.0 ft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 50.0 ft 50.0 ft2 7.0 x 8.0 ft 56.0 ft2 Ty Construction Ll-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2--'F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 '18A-4ocs 4A5 tom: ': _0.143 0.770 , n ' , ri" 4.00, 2,1.' 2.55 19.31 8 0 `- . 8 0 32 U - 20 0 0 ' 0 0 .. 0: : 0 0 0 :0 13A-4ocs 0.143 a 4.00 2.55 48 27 108 69 0 0 0 0 11 - � S IA-clom 11D0 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 W VN 13A4ocs 13A4ocs 0.143 0.143 se s 4.00 4.00 2.55 2.55 0 0 0 0 0. 0 0 0 0 64 0 57 0 228 0 145 t-G 1A-clom 1.270 s 35.56 34.77 0 0 0 0 7 7 247 241 13A-4ocs 1A-clbm ;- 0.143 1.270 .,0.770 _ w w .,w.' 4.00. 35.56 . 21.56 2.55 55.21 : 19.3l 0 0 0 0 0 . 0 0 0 0 0 0 :0 0. - 0 :, 0 0 0.1 . .0 .0 '0' 0 0 0 . 0 P. C . 12C-0sw 16A-30ind.-` 0.091 0.032. - :< _ ; 2.55 0:90: 1.28 , 232 72 50 72 .50 183 45 92 . _ 116 0 .,. .56 0 ' 56 0 : - 5.0 0 F 22A-tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 0 6 c)AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 01 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 913 529 885 . 516 Less extemal.load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 132% 49% 289 258 32%1. 490/6 280 251 Total room load 1202 787 1166 768 Air required (cfm) 1591 35 58 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �A wtightsoft- 2017-Apr-11 0 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 ...dick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N -- wrightsoft- Duct System Summary Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email; QUICKCALCS AOL.COM itroject intormation For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL External static pressure Pressure losses Available. static pressure Supply! return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating. 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Job: Date: By: Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mati . Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox0 VIFx 22.4 115.0 st1 BEDROOM 2 h 4702 232 232 0.360 7.0 OxO VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 Ox0 VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox 0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BATI-I-A h 768 58 34 0 0 Ox 0 VlFx 0 0 wlc c 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 _ 1091 0.285 1020 14.0 0 x 0 VinlFlx wri MSOfta RightSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-1109:29:38 �� � 9 1CA ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 1 Return Branch Detail Table Name Grille Size (in) . Htg (cfm) clg (cfm) TEL (ft) Design M Veloc (fpm) Diam (in) H x W (in) . Stud/Joist Opening (in) Duct Mat[ Trunk rb1 Ox 0 1160 1160 0 0 0 0 Ox 0 VIFx t F1tSOft' 2017-Apr-11 09:29:38 WI'1 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N