Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
• .�CArNN��` ® Project Summary B� Job: - - wrightsoft Entire House St Lucie COLAY Date: By: QUICK CALCS, INC. 317 sT. LUCIE.LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796. Email: QUICKCALCW0L.COM. For: THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 - Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 24753 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Ducts 2318 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cool ingg % (none) Area (ftz) 1446 14 Equipment, latent load 5521 Btuh Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment total load 30274 Btuh Equiv. AVF (cfm) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 Cond 25HBC536A*030 AHRI ref 7914585 Coil FX4DN(B;F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 47OF Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling . 34800 Btuh Actual air flow. 1160 cfm Actual air flow 1160 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.5.0 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft` 38 Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:ge Page 1 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N wr ghtsoft Right-M Worksheet Dat Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email; QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM .2 3 Exposed wall Room height 156.2 ft 8.7 ft d 49.0 ft 8.0 ft heat/cool 4 Room dimensions 1.0 x 297.0 ft 5 Room area 1445.5 ft2 297.0 ft2 Ty Construction number U-value (Btuh/ftk°F) Or HTM (Btuh/ft') Area (ft2) or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) . Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 " �1 13A�ocs 13AAocs 0,143 0 770 0.143 . n • w a ,4:00' 21.56 4.00 6.5 19.31. 2.55 503 38 128 465 '..0 83 1862 " 815 333 ` 1184 730 212 ". 72 ' 0 0 72 '.' 0 0 .. 288 . ;0 0 ;183 0 0 11 � L- 8 1Aclom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 W "";93Aflocs W L-G 13A4ocs 1Ac1om 0.143 0.143 1.270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 34 360 7 34 353 7 136 1414 247 86 899 241 0 216 0 0 216 0 0 865 0 (Y 550 0 13A4ocs 1Ac1om 0.143 1.270 w " w 4.00 35.56 ". 2.55 55.21 310 32 237 2 949 1140 603 1770 104 32 72 2 288 1140" " 183 . 1770 P 4A5 2om:.:. 12C-0sw .6.776 0.091 ' w - 21.66 2.55. 19.31 1.28 41, 192 _ 41 192 .. 880. 489 ". 788 246 0 0 " - " . 0, 0 0 0 ... 0 0 ;C S16A30md - 0.032 - 0 90' . 2.32 1446 1446 1295 .: 3354 .. 297 , _" 297 266 `: 689 F . 22A-tp1 0.989 - 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c)AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration . 2887 791 848 232 b) Room ventilation 0 0 0 0 131. Internal gains: Occupants @ 230 6 1380 3 690 Appliances/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Less .transfer 0 0 0 0 Redistribution 0 0 0 0 14 "Subtotal 17848 17520 5053 4925 15 Duct loads 32% 49% 5654 8536 32% 49% 1601 2400 FTTotal room load 23503 26056 6653 7325 Air required (cfm) 1160 1160 328 326 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -JA- wrightsoft- 2017-Apr-11 06:29:38 ��eA Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N + wrightsoft Right4l& Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC KrrCHEN • 2 E)posed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 9.0 ft 64.0 ft2 1.0 x 172.0 ft 172.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross • WP/S Heat Cool Gross N/P/S Heat I Cool 6 tom 13AAocs 0.143 0.770 0.143 . -. n'. ' n' a . 4:00. 21.56 4.00 2:55 19:31 2.65 6. 0 0 p 0 .0 '0.- • 0 0 p :0 0 .p 0 0 . 0. ' 0 0 . : , p 0 0 . • p 0' 0 .:4AS 11 --G L-D IA-clom 11DO 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W - . W L-G 13AAocs 13A-4ocs IA-clom 0.143 0.143 1.270 se . s s 4.00 4.00 35.56 2.55 2.55 34.77 0 0 0 0 0 0 0.1 0 0 0 0 0 0 0 0 0 0 0 -0 0 0 0 0 0 13A4. 1A-clom 0.143 1.270 w w 4.W 35.56 2.55 55:21 0 0 0 0 0 0 0 0 0 0 0 0 0. 0- 0 -0 P 4A5.2orn . 12C-0sw .0.770 0.091 w - 21.56 2.56 19.31 1.28 0 0 0 0 0 0 .0 0 0 64 .0. 64 0 163 0 82 C .. , ' :16A30md 0.032 --- 0.90 -2 32 54 ,.. 54 48 125 172 172 . -154 ..399 F 22Atpl 0.989 - 27.69 0.00 54 0 0 0 172 0 0 0 6 c)AED excursion -9 -170 Envelope loss/gain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Duct loads 1 32% 49% 15 57 32% 49% 100 1126 Total room load 64 174 418 3437 Air required (cfm) 3 8 21 153 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 :229:38 ...uick Calcs\Documents\THE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N 9 - wrightsoft, Right-M Worksheet Job: Entire House Date: By: QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 •2 Eq3osed wall 5.0 ft 34.2 ft 3 Room height 8.0 ft heat/cool 8.0 ft heaNcool 4 5 Room dimensions Room area 9.0 x 5.0 ft 45.0 ft2 1.0 x 203.5 ft 203.5 ft2 Ty Construction Ll-value Or HTM Area (ft2) Load Area (ft� Load number (Btuh/ft2L°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter. . (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-0ass 0.143 . -. n 4:00 ,_ 2.55 40 40 160 ,102 128 ,- 128 . 519 326 0;770 ' n .. Z.56 19.31 0 0. 0 0' 0 0 . :6- 0 13A4ocs 0.143 a 4.00 Z55 0 0 0. 0 80 56 225 143 11 1A-c1om 11130 1.270 0.390 a a 35.56 10.92 87.29 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 VV W L--G .13A4ocs 13A4ocs 1Ac1om 0.143 0.143 1.270 se s s 4.00 4.00 35.56 Z55 Z55 34.77 0 0 0 .0 0 0 0 0 0 0 0 0 34 32 0 34 32 0 136 128 0 86 81 0 13A flocs ` 1Ac1om 4A5-26m 12C-0sw .0.143 1.270 .0.770 0.091 w , w 'w - 4.00 35.56 ' 21:56 2.55 255 55.21 , 19.31 1.28 . 0' 0 0 0 0 0 0 0 0 % 0 0 .0 ; 0 0 0 0 0 6: 0 0. -0 6. 0 0 . - 0 0 0 0 - 0, 0 0 P C `; ... '. 16A=30md� 0.032 - 0.90 2.32 45. 45, 40. 104 _ 204 -264 . - . :.182 412' F 22A tpl 0.989 - 27.69 0.00 45 5 138 0 204 34 946 0 6 c)AED exursion -16 -85 Envelope loss/gain 339 190 2978 3106 12 a) Infiltration . 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances/other 0 1 0 Subtotal (lines 6 to 13) 425 214 3571 3498 Less exfemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Duct loads 32°/u 49% 135 104 32% 49% 1131 1704 Total room load 560 318 4702 5203 Air required (cfm) 1 1 28 14 232 232 Calculations approved bvACCA to meet all reQuirements of Manual J 8th Ed. -Fkwrightsoft, 2017-Apr-11 09:29:38 ,GZA Right -Suite@ Universal 2017 17.0.14 RSU08101 Page 3 ...uick CalcstDocuments\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N - - wrightsoft- Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY GREAT/DINING • 2 3 Exposed wall . Room height 6.0 ft 8.0 It heat/cool 47.0 ft 9.8 It heat/cool 4 5 Room dimensions Room area 7.0 x 6.0 ft 42.0 ft2 1.0 x 526.0 ft 526.0 ft2 Ty Construction number U-value (Btuh/ft22F) Or HTM (Btu ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 6 11 yJ V�[:7G �---D 13A-0ocs . - -4A5 2orri 13AAocs 1Ao1om 11130 .13AAocs 13AAocs 1Aclom 1Ac1om ,4AS-2om. 12C-0sw 16A 30mti: - 0.143 0770 0.143 1.270 0.390 0143 0.143 1.270 0.143 1.270 0.770 0.091 0.032 - n'- ri.: a a a se s s w w w - . = 4,00 2156 4.00 35.56 10.92 4.00 4.00 35.56 4.00 35.56 -21.56 2.55 0.90 255, 19:31 2.55 87.29 11.31 2.55 2.55 34.77 2.55 55.21 19.31 1.28. : � 232 . 0 0 0 0 0 0 48 0 0 0 0: 56 ` 42 0 : 0 0 0 0 0 48 0 0 0 0.. 56 ` 42 0 0 0 0 0 0 192 0 _ 0 0 ..0 143. . 38 ! 0 0 0 0 0 0 122 0 0 0 0 72 :. 97 255 :38 0 0 0 0 0 0 206 0 41 0 :526 217 ' 0 0 0 0 0 0 0 ' 165 0 41' 0 526 869 : �:815 0 0 0 0 0 0 661' 0 880 .0 . -471; 552 730 0 0 0 0 0 0 420 0 788 0 --, ..1220 W W L-G U13AAocs P :C F 22A tpl 0.989 - 27.69 0.00 42 6 166 0 526. 47 1302 0 6 c)AED excursion -22 668 Envelope loss/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal Qines 6 to 13) 643 298 5994 5112 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 643 298 5994 5112 151 Duct loads I 321/0 49% 204 145 32% 49% 1899 2490 Total room load I 146 443 7892 7602 Air required (cfm) 1 1 42 20 390 338 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. ��� -- wrightsoft- Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 0 Page ae 4 ...uick Calcs%DocumentslTHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N 9 - wrightsoft' Right-M Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN.. FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@/10L.COM 1 • 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area FOYER 7.0 ft 8.0 It heat/cool 1.0 x 50.0 ft 50.0 ft2 M. BATH 8.0 ft 8.0 ft heat/cool 7.0 x 8.0 ft 56.0 ft2. Ty Construction number U-value (Btuh/ft2�_1F) Or HTM (Btulff) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Stuh) Heat I Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 11 ;4A5 tom. ` :' 13A4ocs 1A-c1om 11DO 13A4ocs 13A4ocs 1Aclom 13A4ocs 1A-clom ,_ 4A�r2om':, 12C-0sw 0,143 0.770 0.143 1.270 0.390 0.143 0.143 1.270 0.143 1.270 -.0.770 0.091 0.032 .. n' -' 6' a a a se s s _ w w •..:w. - - 4.00' 21.56 4.00 35.56 10.92 4.00 4.00 35.56 4.00 35.56 21.56 2.55 0.90 . 255 19.31 2.55 87.29 11.31 2.55 2.55 34.77 2.55 - 55.21 p 19.31 1:28 2.32 8 . 0 48 0 21 0 0 0 0 0 0 72 50 8 0 27 0 21 0 0 0 0 0 . 0: 72 '50 32 0 108 0 229 0 0 0 0 0 0 183 45 .. 20 0 69 0 238 0 0 0 0 0- :0- 92 .. 116 .. 0 '0 0 0 0 0 64 7 0 0 0 0 56 0 . p 0 0 0 0 57 7 0 0 0:- 0 56, : 0 "0 0 0 0 0 228 247 :0 0 0 0 56 .0 . 0 0 0 0 0 145 241 0 0 0, 0 ,130 VI/ W Vi/ t--G P F 22A tpl 0.989 - 27.69 0.00 50 7 194 0 56 8 222 . 0 6 c)AED excursion -39 -38 Envelope loss/gain 792 496 747 478 12 a) Infiltration b) Room ventilation 121 0 33 0 138 0 38 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 p 0 0 Subtotal (lines 6 to 13) 913 529 8851. 516 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 32% 49% 0 0 0 913 289 0 0 0 529 258 32%1. 49% 0 0 0 885 280 0 0 6 516 251 Total room load Air required (cfm) 1202 59135 787 1166 58 768 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A -Fk wrighltsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 ...ulck Calcs%Documents\THE GRAND CARLTON-1446.rup Cale = MJ8 Front Door faces: N Page 5 r -�+ wrightsoft° Duct System Summary Dab: Entire House By: QUICK CALCS,INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM o For. THE GRAND CARLTON WYNNE DEVELOPMENT, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O .0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 NO VIFx 22.4 115.0' st1 BEDROOM 2 h 4702 232 232 0'360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163 0.300 6.0 Ox0 VIFx 31.8 135.0 st2 BEDROOM-B h 3327 164 163 0.285 6.0 OxO VIFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 OxO VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox0 VIFx 31.8 135.0 st2 KITCHEN c 3437 21 153 0.379 6.0 Ox 0 VIFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 VIFx 0 0 WIC c 174 3 8 0.309 4.0 ox0 VIFx 27.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 721 672 0.285 918 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx ACAwrightsoft@ Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 ...uick CaicsIDocumentSITHE GRAND CARLTON-1446.rup Calc = MJ8 Front Door faces: N Page 1 Name Grille Size (in) . Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) . H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 NO 1160 1160 0 0 0 0 Ox 0 VIFx AL f'" wrightsoft' Right -suite® Universal 2017 17.0.14 RSU08101 2017-Apr-11 09:29:38 Page 2 )IM ...uick Calcs\Documents\THE GRAND CARLTON-1448.rup Calc = MJ8 Front Door faces: N