HomeMy WebLinkAboutREVISION 3-27-18OFFICE USE ONLY:
CANNED
DATE FILED: 3 2� hi .$ BY PERMIT # 1.712-0745
�,: St Lucie County
:.. REVISION FEE:. 7 .. RECEIPT # 'I
.R
PLANNING & DEVELOPMENT SERVICES
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982-5652
(772)-462-1553 FAX.(772) 4624578.
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1.. LOCATION/SIT '
ADDRESSc Quintana Roo. Lane
2.. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Placement of Home on Lot has Changed - Changing to Impact Windows - Adding.a 6x10
Slab Off Rear of Home
3. CONTRACTWINFORMATION:
STATE of FL-REG.:/CERT. #: ST. LUCIE COUNTY CERT. #: 8898
BUSINESS NAME: Wynnei Buildingorpora ion
QUALIFIERS NAe
ADDRESS: 0 South US Hwy. 1 Suite 402
CITY:. ort St. Lucie STA �,. „ I
3495
PHONE (DAYTIME): - 7
4. OWNERBUILDER.' INFORMATION:
i 1
NAME: Wynne.Building Corporation 5
ADDRESS: out wy. I Suffe 402
CITY: ST vWq N 34952 .
PHONE:.7721878-5513 (7 ) 8.- 5
5. ARCHITECT/ENGINEER INFORMATION:
NAME: BRADEN & BRADEN
ADDRESS. . .
CITY: STUART STATE: 'FL 34996
PHONE. (DAYTIME): (772) 287-8258
U.9
�+
Revised 07/22/2014
File
I
Not Inclu qS e l &,This Permit
He Copy
FORM R405-2017
\'I'A Va ___ (Z)n�_k '-�
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE PRAND CARLTON
Builder Name: WYNNE BUILDING COPR.
' Street: QS ,r 'NA VN)-z-J'"%'
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1250.00 ftZ
b. Frame - Wood, Adjacent
R=11.0 192.00 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1446.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft Z
6. Conditioned floor area above grade (ftZ) 1446
b. N/A
R= ftZ
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
11. Ducts
R ftZ
7. Windows(141.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor: Sgl, U=0.36 101.25 ftZ
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.65 40.00 ftZ
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ftZ
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftZ
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1445.5 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1445.50 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
15. Credits
Pstat
Total Proposed Modified Loads: 47.17
Glass/Floor Area: 0.098
PASS
Total Baseline Loads: 48.08
1 hereby certify that the plans and specifications covered by
Review of the plans and
&Z$E ST,q?,
this calculation are in compliance with the Florida EnJergy,
e ' f e b hi
,y� _O
Code.
Ic i t is a
PREPAR D BY:
DATE: -
f e tru i is I ed
t i it ins or
c li nce t cti 08
Vs
r
y
*`O
I hereby certify that this building, as designed, is in c
the Florida Energy Code.
F d
COD
with
WE
OWNER/A '
BUILDING OFFICIAL:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
File Copy
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR.
Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: ST. LUCIE COUNTY
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1446 11568
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM
301 2408 No
0
1
1 Yes
Yes
Yes
2 WIC
63 504 No
0
1 No
Yes
Yes
3 M.BATH
56 448 No
0
1 Yes
Yes
Yes
4 KITCHEN
192 1536 Yes
0
1 No
Yes
Yes
5 BATH
45 360 No
0
1 Yes
Yes
Yes
6 BEDROOM 2
204 1632 No
0
1
1 Yes
Yes
Yes
7 ENTRY
55 440 No
0
1 Yes
Yes
Yes
8 LAUNDRY
42 336 No
0
1 Yes
Yes
Yes
9 GREAT/DINING
488 3904 No
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
BEDROOM 52 ft 0
301 ft2
----
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1 ft 0
63 ft2
----
0 1
0
3 Slab -On -Grade Edge Insulatio
M. BATH 8 ft 0
56 ft2
----
0 1
0
4 Slab -On -Grade Edge Insulatio
KITCHEN 1 ft 0
192 ft2
----
0 1
0
5 Slab -On -Grade Edge Insulatio
BATH 5 ft 0
45 ft2
----
0 1
0
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 32.2 ft 0
203.5 ft2
_---
0 1
0
7 Slab -On -Grade Edge Insulatio
ENTRY 7 ft 0
55 ft2
----
0 1
0
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio GREAT/DINING 46 ft 0
488 ft2
----
0
1
0
ROOF
Roof
v
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
# Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
0.6
No
0.9
No
0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301 ft2
0.1
Wood
2 Under Attic (Vented) WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30.
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
WALLS
Adjacent Space Cavity Width
9 C)rnt In Wall Type1
Height
Sheathing Framing
Solar
Belo w
NE=>SW Exterior Concrete Block - Ext InsfflEDROOM
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
_ 2 SW=>NE Exterior Concrete Block - Ext InsiHEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.6
0
_ 3 NW=>SE Exterior Concrete Block - Ext InsIBEDROOM
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
4 SW=>NE Exterior Concrete Block - Ext InsuM. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.6
0
5 NE=>SW Exterior Concrete Block - Ext Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.6
0
6 NE=>SW Exterior Concrete Block - Ext InfiffDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
0.6
0
7 SE=>NW Exterior Concrete Block - Ext InRffDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
8 S=>N Exterior Concrete Block - Ext InMEDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.6
0
9 SW=>NE Exterior Concrete Block - Ext InfiffDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.6
0
10 SE=>NW Exterior Concrete Block - Ext Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
11 SW=>NE Exterior Concrete Block - Ext Insul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.6
0
12 SW=>NE Exterior Concrete Block - Ext InsillAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
_ 13 NE=>SW Exterior Concrete Block - Ext Ins8REAT/DINI
4.1 26
0 8
0
208.0 ft2
0
0
0.6
0
14 NW=>SE Exterior Concrete Block - Ext InsGiREAT/DINI
4.1 20
0 8
0
160.0 ft2
0
0
0.6
0
15 N=>S Garage Frame - Wood KITCHEN
11 24
8
192.0 ft2
0.23
0.6
0
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
DOORS
# Ornt
Door Type Space
Storms U-Value Width
Ft In
Height
Ft In
Area
1 SE=>NW
Insulated ENTRY
None .39 3 1
6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V # Ornt ID Frame
Panes NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW13 Metal
5 NW=>SE14 Metal
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
Low-E Single Yes
0.36 0.25 N 32.9 ft2 1 ft 0 in 1 ft 4 in
0.36 0.25 N 6.9 ft2 1 ft 0 in 1 ft 4 in
0.36 0.25 N 24.0 ft2 6 ft 0 in 1 ft 4 in
0.36 0.25 N 37.5 ft2 1 ft 0 in 1 ft 4 in
0.65 0.21 N 40.0 ft2 8 ft 0 in 1 ft 4 in
Drapes/blinds
None
None
None
Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft
11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356
1349.6 74.09 139.34 .2598
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Heat Pump/ Split
HSPF:8.5 34.8 kBtu/hr
a 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType Location
EF Cap Use SetPnt
Conservation
1 Electric
None Garage
0.97 40 gal 60.9 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume FEF
None None
ft2
4/17/2018 2:46 PM EnergyGauge@) USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
DUCTS
--- Supply
---
---- Return ----
Air
CFM 25
CFM25
HVAC #
V # Location R-Value
Area
Location
Area
Leakage Type
Handler
TOT
OUT
QN
RLF
Heat Cool
1
Attic 6
250 ft2
Attic
65 ftz
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
HeatinHJan
Feb
Feb
Mar
Mar
[
[ ]
A r [
Apr [
Ma
May
Jul.
Jun Jul
rj Jun rl
Au
AuSep
rl
Se
rl
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
Ventin Jan
Feb
X Mar
[X]
A r [
Ma
Jun Jul
Aug
Se
Oct
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78 78
78
78
80
80
80
80
PM
80
80
78
78
78 78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78 78
78
78
78
78
78
78
PM
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66 68
68
68
68
68
68
68
PM
68
68
68
68
68 68
68
68
68
68
66
66
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind n 0 Dino and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover plates and walls or ceolongs-
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/17/2018 2:46 PM EnergyGauge@) USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX` = 98
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2
7. Windows-
Description
a. U-Factor:
Sgl, U=0.36
SHGC:
SHGC=0.25
b. U-Factor:
Sgl, U=0.65
SHGC:
SHGC=0.21
c. U-Factor:
N/A
SHGC:
d. U-Factor:
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
, FT. PIERCE, FL,
New (From Plans)
9. Wall Types
Insulation
Area
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1
1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0
192.00 ft2
1
c. N/A
R=
ft2
2
d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1446.00 ft2
1446
b. N/A
R=
ft2
Area
c. N/A
R=
ft2
101.25 ft2
11. Ducts
R ft2
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
40.00 ft2
12. Cooling systems
kBtu/hr
Efficiency
ft2
a. Central Unit
34.8 SEER:15.00
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
ft2
13. Heating systems
kBtu/hr Efficiency
a. Electric Heat Pump
34.8 HSPF:8.50
3.832 ft.
0.239
Area
14. Hot water systems
1445.50 ft 2
a. Electric
Cap: 40 gallons
EF: 0.97
ft2
ft2
b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features. \
Builder Signature: Date:
Address of New Home��� `,C-\ City/FL Zip:�S`,,_.
ZHE ST.gT�oo
i- a
Md
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/17/2018 2:46 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1