HomeMy WebLinkAboutBUILDING PLAN8'-I" T.O.B.
12"
O'-O� Finished Floor
12
SLOPE
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 41101,12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" enc
laps fastened with corrosion resistant tin cape and with 5" ring shank nail
spaced 6" o.c_ at all laps and two etaggered rows 12' o.c, field. Attac
deck to trusses using attachment detail on this sheet
�UpEg t r... OMPLt�t,�
ALI -MiAs
A AND SHOE C MUST
u Coot5
rcw P 6TlEp Ey8 ANO W1No E
W
l ® 4uo AppR
thlmh^�`EcO�u ed
stucco on cal concrete
block construction
5/8" thick x 8"w cut
coral finished stucco bands
LEFT ELEVATION
SCALE: 1/4' =
Gulf Coast Supply and MFG 5v Crimp Met I roofing FL #11651.12
26 ga. Sv crimp metal roofing attached to lywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" c, max spacing over ASTM D
(type 2) 30 lb felt underlayment installed ith min. 4' side laps and 0 end
laps fastened with corrosion resistant tin ca�a and with 1.25" ring shank nails
spaced L" o.c. at all laps and two staggere rows 12" o.c. in field. Attach
deck to trusses using attachment detain on his sheet
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411651.12
26 ga. Sv crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and C end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c. at all laps and two staggered rows 12" o-q in field. Attach
deck to trusses using attachment detail on this sheet
1licSE PLANS AND ALL PROPOSED WORW
ARE SUBJECT TO ANY CORRECTIONS
RE 4UIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE C1)68'
H.
5/8" thick x 8"w cut O
coral finished stucco bands
EJT..
Finish Columns with
5/8" thick cut coral
finished stucco bands
ELEVATION NOTES:
5/8" thick light textured
stucco on typical concrete
block construction
REAR ELEVATION
- Overhangs at I'-C" unless otherwise noted on Roof Plan
- Roof pitch at 4:12 unless otherwise noted
- ,Any changes to this plan shall be submitted to the architect
for approval in writing prior to starting construction.
- Return ALL Stucco Bands Into Window or Door.
12
SLOPE 4
GoN0,l4-40,rgS
gAArHSA yAAS,
0,0NTAgCT� llybp 41r
12" 5/8" thick x 8"W cut 12"
H. coral finished stucco bands H.
3 3 5/8" thick x 8"w cut
coral finished stucco bands
�5/8" thick light textured
stucco on typical concrete
block construction
--------------_--------------------------------------- - - ---- 0'-0" = Finished Floor
Finish Columns with
5/8" thick cut coral
finished stucco bands
RIGHT ELEVATION
SCALE: 1/4" = 1'-0" tAANUF RS�� 1Na
Ul'A4fQ nnNI"coDt M41s
_ ."'Mr UW5
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, gliding Doors, Windows IN Skylights
Opening
NOA/FL
Product
Model #
Manufacturer
Glass
Attachment method
Type
NUMBER
1,2,3
MI Windows
L ipp. x tlpcona w mrt. penettpuon at maxx.
roe rach corner end L o.c. thereafter through PT Buck Into solid
FLU 11499.2
Single Hun
9 9
Series 185
and doors
m
hued CMU wall maintm xng min 2.5" edge distance in strict adherence
to the product a pr
A
16-0330.02
Overhead
Model 824/811
9'-4' max width
DAB
ant x uc to cocrste oc with i et
a ors br ve t umng a/e• x 6' WU MLC cleave anchor, n 9' ac.
h 115 da. sash". wit ea 4' wipe de ante. lnotall track to buck
Garage Door
L'-O" max height
Mail (D 5/16• x 1 5/e" full bread wg ,cries w fib,.memtemng
win or 15• edge detente - GC to amtlg adMre to product approval
rovids 1/K' bahmut Waw,e an r "te,
Elco 1/4" dia. tapcon with min 1.25" embedment at 3" max
B
FLU 14414.1
Fiberglass
Desn
Jeld-Wen
from corners and n.5" o.c, max thereafter in head and jambs.
Smooth Pro/
Sliding Glass
M+ Windows
i x �lpc-2 w m'% enatlation at Max.
roan each corner and l" o.c. all dowDls raw t�erea/ter through
C
FLU 15332.2
Door
1 Series 420
and doors
PT Suck into wild
1n strict adherence
filled CMU wall maintaining aim 2.5 edge diatancn
to the product approval.
Product
NOA/FL
Model #
Manufacturer
Attachment Method
NUMBER
For CMU use (2) 1/4' x 2 3/4' tapcons with min 1 1/4" embedment
CM-18531
MI Windows
penetration into each Mull Clip. Attach mull to clip using (4) #10 x 1.25"
Mullions
FLU 15353.8
vertical mullion
and doors
dell tapping screws per clip as shown in product approval.
Roof
FLU 11651.12
5V Crimp
Gulf Coast Supply
2L ga. 5v crimp metal roofing attached to plywood deck using a9 x 1.5"
washerspacing
Metal Roofing
and manufacturing
�toode 2) 30wlhh felt underla nstalled with minx 4' lapsrand56Men
resistant mg
laps fastened with corrosion tin caps and with 1.25" shank nails
spaced L' o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on roof plan
2" x 4" top plate
pUiration Design Pressu�6EIgIAN^ 4if �I,,L PROPOSED WORK
to of Approved T@ "cCY i'O pNY COR iECTfONS
drywall ceiling on truss bottom cord
ill D BY FIELD INSPECTORS THAT
± 60 par MAY Bi I IECESSARY IN ORDER TO
COMPI. NITH ALL APPLICABLE CODA,
-9-21 + 50.0/-60.0 psf
I/2" drywall on
+ 50.0 PSF 2" x 4" studs at 16" o.c.
+ 48.2 PSF
Aration Design Pressure
e of Approved Tests
+ 118.9 PSF
base -board / 2" x 4" P.T. bottom plate
- 108.5 PSF
Siding
Stucco on Block
Soffit
FLU 12198.3
Model T4 12" vented
Vinyl Soffit
Kaycan
Install using 2" x 2" battens at 6' o.c. screwed to soffit framing using
an each ntruss. k nails Intstall soffit
lato battens using
012 3" wood screws
d.
+ 55.0/-35.0 PSF
Hurricane
Panels
FI# ISO16,2
24 Gauge
Storm Panels
Global Protection
Products LLC
Install using 1/2" dia. solid set lead anchors with 1/4" dia.-20 x 1.5"
long SS screw head combo. with Neoprene washer at 12 1/2' o.c.
along the bottom and 13" o.c. at the top
± 45.0 PSF
I have reviewed the above and approved it by my seal below. ( Architect or Engineer I of Record )
12
SLOPE 14
a
12„
H.
O'-O" _
Finish Columns with
5/8" thick cut coral
finished stucco bands
SCALE: 1/4" = 1'-0"
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6" o.c, at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
5/8" thick light textured
stucco on typical concrete
block construction
FRONT ELEVATION
SCANNEE
13Y
St Lucie COunlq
ST. LUCIE COURTy BLT?1D? IVISION
REVIEWED FOR COMP ANCE
REVIEWED BY
DATEPLANS AN PE MI S E KEPT ON JOB
SITE OR NO INSPECTION(S) WILL BE MADE
\ 4" concrete slab with fibermesh OR
6"x4" 410/10 WWM on 6 mil Vlsqueen over
clean compacted termite treated fill
Interior Nor -Bearing Partition
nts
Braden it
Braden AIA, FA
Wgnne
Building Corp.
- Planners
BTelArchitects
41
S.E. Coconut Avenue
The
Grand Carlton
: (112) 281-8258
Spanish Lakes
Fax : (112) 2 87-8283
E-mail:
bradenaia comcast. net
St. Lucre
County Florida
Stuart. FL
34994 #AACOO0032
1/8" Thick cut coral stucco over paper
backed wire lath nailed to substrate through
one layer of 15 lb felt using Bid nails. Substrate
to be 19/32" COX Plywood nailed at 6" o.c.
in field and edges with IOd ring shank galvanized
nails into truss webbing.
12
SLOPE 14
thick x 8"W cut
coral finished stucco bands
1011101111
FILE C&"','
SCALE: 1/4" = 1'-0'
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP.
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION DORM 100)
Florida Building Code Residential: 5th Edition and ASCE 1-10 for Wind Loading
Building Design is: Enclosed Risk Category: II Wind Velocity: ItS mph ultimate
Mean Roof Height: W-O" Roof Pitch: 4:12
Internal Pressure Coefficient: ±o.18
SubUectabditg to damage from: Weathering: Negligible Termites: Vertl Heavu
Width of Roof End Zone: 34", Wind Speed: 165 mph ultimate
Wind Exposure Classification. C 1.21 x 0.6 = 0.12G
Adjustment factor for Exposure Height: ASD design
Load Combination: ASCE 1-10 Section 2.4 DL+LL; DL+OA.WL; O.4DL+O.6wL
Components E Cladding Wind Pressure (NET) Roof Zone: I. +20.4/-32.6 psf
Roof Zone: 2. +20.6/-51.0 par
Roof Zone: 3. +20.6/-84.0 psf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Wall Zone: 4.+35.8/-38.1 psf
Wall Zone: 5. +35.8/-41.8 par
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3par
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided? es
Are Components an Cladding Det� Provided? Yes
Minimum Sal Bearing Pressure:2,500 psi, Presumptive: X Bg Teat: pal
This Budding Shall Have the Following:
APPROVED SHATTERS: X IMPACT GLASS: BOTH: NEITHER:
ROOF LIVE LOAD: al per ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: -AS- per FLOOR DEAD LOAD: 10 par
ITCH
0 = Roof Zone I
Walla Zone 4
ES = Roof Zone 2
Walls Zone 5
END ZONE
= Corner Zones
Roof Zone 3
JOB ADDRESS: ;\S'\c�c� `Zap
MODEL: Date Drawn Revisions : Sheet Comm #
5-9-I1
GARAGE Drawn by:
RIGHT C,C.U. 1- 12 - 2 7
Checked by:
D.R.B. OF 5
FLOOR PLAN 4 CRASH POST DETAIL
TYPICAL NOTES: SCALE 1/4" = 1'-0" N.T.S.
3L" high by 4" diameter
I. Contractor to verify ALL notes and dimensions prior t0 steel crash post. Floor
proceeding with work. Flange with 4 - 2. Contractor to STRICTLY enforce ALL OSHA Requirements. expansion bolts into
slab (3/8"t 50 ksi steel plate)
3. ALL Lumber to be used as Beam, Rafters, etc... to have
a minimum 1,400 P.S.I. fiber stress.
4. NO dissimilar metals 1.0 touch.
S. ALL Concrete used for slabs shall be min. 2,500 PSI concrete. /2
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
(o. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R�102.3.5•
-I. ALL wood in contact with concrete shall be pressure treated.
8. ALL wall dimensions are nominal and not finished wall or stud dimensions.
9. ALL plumbing fixtures to be low flow.
10, Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11. Contractor to Provide a 2'-8" wide door at one bathroom for 2., 2y,
handicap accessibility requirements. _"
12. Lowest finished floor to be set by Governing Building Department
surveyor to set in field.
13, Separation between residence and garage shall be per FBC R302.6
14. Door between garage and residence shall be 1-3/4"t 20 min, rated door
w.H. = Water Heater
15. Wall and Ceiling shall have a flame -spread classification of not greater than 200 pper FBC R302.9.1
16. Wall and ceiling finishes shall have a smoke - developed index of not greater than 450 per FBC,I R302.9.2
11. All exposed attic insulation materials installed on attic floors shall have a critical radiant I" 'x 6" P.T. Buck nail
flux not less than 0.12 watt per square centimeter. Exposed foam plastic insulation block with case harden
materials exposed on the underside of the roof deck or on the attic walls shall comply pri r to door attachme
with F.B.C. R316 - see permit info box of code edition
18. G plum board material shall conform to ASTM C36, C19, C4-15, C514, C630, C931
C`f 0, C1002, C1041,C1177, C11-18, C1218, C1395, or C1396 and shall be installed
according to the following: (FBC R-102.3.5)
Or wall
Thickness
Location
Orientation
Framing
Member
Max. spacing
of fasteners
Nail sizing options for
installation of drywall into
Spacing
Maximum
wood framing members
2" x min. thickness
Nails
Screws
Ceiling
Perpendicular
24"
121,
13ga 1 3/8" long with 19/44" head
OR
0.098" diameter x 1 1/4" long
annular —ringed or 5d cooler nail
�2
OR
Walls
Either
16"
S.
"
1L"
O.OdO" dia. xx 1 5/8" long with
15/64" headOR
Direction
G psNm board nail 0,086" dia.
x 5/e with 9/32 head.
Ceiling
Perpendicular
24"
1"
12"
13ga 1 6/8" long with 19/64" head
OR
0.098" diameter x 13/8" long
annular —ringed or 6d cooler nail
OR
e
0.092" dia. x 1 1/8" long with
1/4" head
Walls
Esther
16"
g°
16"
Direction
OR
Gypsum board nail 0.0915" dia.
x 17/8" with 19/44" head.
ee 1 O
rzl
0 0
to
Masonry Beam
/
Wads
Install SGD thru buck into q O
block with 3/16" tap -con with
1 1/2" penetration at 6" o.c, max.
from each corner and 20." o.c. ma
thereafter at head per product approval
Use SAC tap -con with
1 1/2" penetration at L" o.c. max.
from each corner and 20" o.c. I max
thereafter at sill per product approval
19, ALL ceramic tile surfaces installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
20. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C11�18 and installed I.A.W. manufacturers recommendations shall
be used as backer for the wall tile in tub areas and wall panels in shower areas.
21. Insulation including facings such as retarders or vapor permeable members installed
within floor -ceiling assemblies, roof -ceiling 8ssemblles, wall, crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanginn smoke
E 84
developed index not to exceed 450 when tested in accordance with'ASTM
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
d wooscrews with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlagment installed with min. 4' side laps and L" end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 6 o.c. at all laps and two staggered rows 12" o.c, in field. Attach
deck to trusses using attachment detail on this sheet
Simpson HETA 20 or equal
hurricane anchor at each truss 12
with (10) IOd x 1 1/2" nails PRE-ENGINEERED TRUSSES
( 24" o.c.) supporting Max. 4 at 24"o.c. TYPICAL
18IOIbs. uplift (shop drawings by manufacturer)
Aluminum Drip —� \R-30 blown fiberglass
Edge ! Fascia in bottom chord of trusses
I/2" drywall unth smooth finish
2" x 6" Sub —Fascia Two rows of beam block filled with concrete
and (1) #5 bar cont. in each raw. substitute
Kagcan full a vent vingi soffit installed precaCst lintel filled with concrete and (1) #5
using 1/8" dia shank x 15" long galv. bar ont. for bottom row over openings
roofing nails with 3/8" dia. head per
product approval — we chart sheet Ul 1/2" drywall over I" x furringg
strips at It" O.C. with R4.1 frfoll
nsulation on typical 8" Block walls
5/B" thick light textured All drgwall to be installed per FBC R102.3.1
stucco is t light
concrete i and shall meet ail pertainingASTM codes.
9P ao Mortar to be Type "M" only proportioned per FBC RL01.1
block construction and Mortar Jonts shall comply with FBC 021.21
Provide Dur-O-Rock at all wet areas (ex. showers, tubs etc...)
#5 bar vert. w/
30" overlap Fill cell with concrete and
at each filled cell,() #5 bar vert. (typical).
Max. spacing shall not exceed
Wood 48" unless otherwise noted
see foundation plan notes for
Base spacing at openings
4" concrete slab with fibermesh OR
6"x6" #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
Grade
IIII=IIII=�II„i�I11-
IIII _ III IIII1111—
114" x� 14" Concrete footing
14° with (2) 45 bars cant. and #5
TY F I C A L S E C T f O N transverse bars at 48" o.c.
Scale : 1/2"
Head
fixed door
sliding door
1 1/2,
Bottom Track It
Sill
SIiding Door Detall
At Masonry Wall NTS
AREA CALCULATIONS
Living A/C
= 144�
sq.
ft.
Front Porch
= 141
Sq.
ft.
Rear Porch
= 200
sq.
ft.
Garage
= 321
sq.
ft.
Total Under
Roof= 2108
sq.
ft.
Total Cubic
Ft = 11,548
2' VTR
AIL
I
I
I
I
21' VTR
I JAL
Master
Bath 1
2
ILay..
2• �
Lay.
I
I
I
�• 2" VTR
3. 1
�L
I I
2' 3•
Shur. 1
Kit. sink I
I
Kitchen 2
I
Lev. 1
3"
W.C.
Bath #2 Shur.
3`
C.O. To Septic
PLUMBING RISER
I" x 0 P.T. Buck nailed to
block with case hardened nails
prior to door attachment ,
Masonry Wall
al Flooring
Install SGD thru buck into
block with 3/14" tap —con with
1 I/2" penetration at 6" o.c. max.
from each corner and 20." o.c. max
thereafter at Jambs per product approval Jamb
Window
Schedule
lark
Size
Rou h O en.
Window Description
PRESSURE ZONE
I.
4'-
%'x 5'-3%"
54%e"x 634'
Single Hung
ZONE 4
2,
G'-%"x
5'-3 %°
15" x 63 %4'
Single Hung
ZONE 4
3.
2'-:!"
x V-2 1/2"
2l%2"x 38%"
Single Hung
ZONE 4
%"x 4'-2%8"
54%s"x 54%"
Single Hung
ZONE 4
ALL I.Lindows
and mullions
ALL w
ALL W
All ro
with m
t0 be aluminum windows W/ tint
per elevations.
ndows to withstand pressures in permit info box on sheet i
ndows in bathrooms to be tempered
gh opening dimensions to be verified bg contractor
nuf acturer s specs prior to construction
Door
Schedule
lark
Size
Rough O ening
Door Description
PRESSURE ZONE
A
9'
0" X 1'-0"
108" x 84"
Overhead Garage Door
ZONE 4
B
3'
O" X 6'-8"
41 %4'x 83%"
Fiberglass Panel - Inswing
ZONE 4
C
6'-10"
X C-8"
i4" x 81 %' ;i ::Hi
Sliding Glass Door
I ZONE 4
D
2.7'0"
X 6'-8"
Solid Core -
Wood - 6-Panel-Bi-Fold Finished 24" x 81 %2"
E
2'�6"
X 6'-s"
Solid Core -
Wood - 6-Panel
F
5'rt0"
X 6'-8"
Solid Core -
Wood - 6-Panel - Bi-Fold
G
2'-
" x 6'-8" x 1 %4'
Solid Core Wood, Steel, or Masonite Door
H
2`
8" X 6'-8"
Solid Core -
Wood - 6-11anel
1
2'
6" X 6'-8"
Solid Core -
Wood - 6-Panel - Bt-Fold
K
7
8" X 6'-8"
Solid Core -
Wood - 6-Panel - Bi-Fold
a
V
EE El EE EE
z
_
EGRESS
12" x 12" concrete column block filled
with concrete and (2) 41 bars vert. tied
into lintels above
0
o
Covered Porch
12'-8"
O
O
O N
E O° Oo I
EE E E ° Oo
c l]
O
MASTER
_
BEDROOM_
i
8'—O" to 9'—S" A.F.F.
Vaulted ailing 8'—O" A.F.F.
nm
Flat Ceiling
tnu_
GR AT
E
ROM
o
E I
Rod Shelf
E
19'-8" L'-4" 4' 6'-0"
Vanity to e °
I
v- I 34 Y2"high
!V
_
N
I t
N to I p— I
H.B.
to
E I r
L SET
E
8'-0" to T-8" A.F. . 2" x 6" knee —wall o
below top IV O M
Vaulted Ceiling I counter 111rr r
I
DiNiNG
ROOML LINEN
I F 8 Rod Shelf ABINET
6
O ro
O
Q
2 � r
W
0.
I B A
O
E
O
Vanity to be i �� °
W
1
34 %2„high I ✓
I
O
High Wall
E
KjITCHEN
"-u
Vent
C ryer
Ov I-I/2"_ _ O
throug
wall
_ I
— — Cver-hang 8'-0" A.F.F.
N L
° Flat Ceiling — ILJI °
O Upper cabinets to
8'-I" 4"3'-O" extend over Ref. -
iv
N I
" fillerN
A T H _ — Rar.
fQfTa�nw ayq �s. .a
4'-O"
WoaxVlaY Penina
E O _ Rod _!_Shelf _
N _ N ® N . —II Batts wlati
O
I
A/ C
O
4"KV Steel Ballard
r3e�
r!1
rJgtad, Qn this sheet
W I $ I,„
c`l
22" x 54° I
F p j Attic Access Provide auto
1 with light I closer
E a d L_-__--
E
8'-O" A.F.F. [ _ _ 22" a
-1
W
Uc
Flat Ceiling
Ln 4„ 150 Amp
s
L, O„
a Panel
Meter
rLT
SECOND © m
IL
a
E N BEDROOM E Y GARAGE
lJII GRESS
EEI PT 1 EE 8'-4" A.F.F. O
E
E E Flat Ceiling
174
° O
N
E
EGRESS r----------------- I
O
Vir
if
E Block wall in I
EE ai E E O _ I garage to be I
-
struck block 1
O
COVERED I I
O
12" x 12" concre a column block filled
o
O
ith concrete and (2) #'1 bars vert. tied QRC I 14'-6" I
into h tels above I i
:a
6" II'—L" 6' 2" t
I i
I I
O
O
a
2' 8„ j
2'—e„
3,_5„ 91_01.
34'—O"
FI!-E
COP
Install windows thru buck into
block with 3/16" tap —con with
1 1/2" penetration at L" o.c. max
from each corner and 20." o.c. max
thereafter at iambs and 20" o.c. max.
Exterior face at head and sill per product approval
of wall --\ / \ Buck to be I" x 4" PT
ALL -xterior doors to withstand pressures stated in permit info varies
box OI sheet #1
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTj ND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET 41
All rough opening dimensions to be verified bg contractor Detail at Windows
with manufacturer s specs prior to construction
I Braden t Braden AIA. FA
Architects - Planners
411 S.E. Coconut Avenue
Tel : (112) 281-8258
Fax : (712) 281-8283
E-mail: bradenaiaOcomcast.net
Stuart. FL 349% #AACOO0032
I"x4" P.T. Buck nailed to
block with case hardened nails
briar to window attachment
NTS
Wgnne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
SILL BLOCK PRIOR TO BUCK
INSTALLATION
Attach buck to block wall with
Y
1/4" dia. Elco conc screws with min.
1 114" penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2" x 6" PT Buck
of wall
snag
#8 y
crews thru jamb into buck
at each hinge and 15" o.c. max and
a t r i nnr• prior to door attachment
MODEL: Date Drawn Revisions
5-9-11
GARAGE Drawn by:
RIGHT C.C.U.
Checked by:
D.R.B.
NTS
Sheet I Comm #
2. 112-21
OF 5
2
3
4
S.
6
1
TFUCIJFAL
AOTE5:
ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2,500 PSF SOIL
9.
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSi AT 28 DAYS
10
ALL COLUMNS, FILLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4,000 PSI GROUT MIX AT 28 DAYS
POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
IL
GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WIRE MESH REINFORCING ON 6 MIL. POLYETHYLENE VAPOR
12.
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FiBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT IN. FILL TO BE SPREAD IN 12" LAYERS AND
MACHINE COMPACTED TO A MINIMUM OF 2500 PSI IN AREA OF
13
BUILDING CONSTRUCTION
TEST FOR FILL COMPACTION MINIMUMS PRIOR TO FORMING SLAB.
14.
GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
is.
ATTENTION OF THE ARCHITECT.
16.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
I'l
F-OuAD/470N FDL/4N
SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
DESIGN LOADS ARE AS FOLLOWS:
ROOF (D,L+LL) = 41 PSF
WIND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
ALL REINFORCING STEEL SHALL BE GRADE 60, MEETING ASTM A-16, t
A-35 SPEC FICATIONS. ALL ANCHOR TO BE A - 30� STEEL.
ALL DOWEL SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AN FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENI GS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCH( ECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING#( 3"
BEAMS: 1-1/2"
LAP ALL R INFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS,
USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
ALL STANC�ARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO. SOUTHERN PINE, UNLESS NOTED OTHERWISE.
ALL LUMBE IN CONTACT WITH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
1. Any changes to plans must be submitted to the architect
for approval before proceeding with construction.
2. Contractor shall be responsible for verification of all
notation and dimensions before starting construction.
3. Soil conditions assumed to be 2800 psf. Should any other conditions ae
encountered, the architect shall be notified in writing for revision
4. Verify all recess thickness at showers, tile, etc....
S. Contractor to provide filled cell with concrete and 1 45 bar vert. at 48"
o.c. max. Provide (1) filled cell on each side of openings up to g'—I1" wide.
Provide (2) filled cells on each side of openings from 6'—O" to 9'-11"
and Provide (3) filled cells on each side of openings from 10'-0" and up
Contractor to see plans for any other condition used. Foundation Walls
shall have filled cells at 24" O.C. unless otherwise noted (see section)
b. Contractor to provide for Form Board Survey — Form Board Survey
to be provided to Truss Company prior to truss construction
1. Contractor to provide for soil test prior to construction and provide
a copy of soil test to architect for review prior to construction
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-16 and
A-35 specifications. ALL Anchors to be A-30-1 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
45 bar vert. w/
30" overlap —
at each filled cell
4" concrete slab with fibermesh OR
11 #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
Grade
00
i I= III I I I I- 14"111 x 14'd concrete monolithic
footing with (2) 3*5 bars cont.
14"
TYPICAL FOOTING DETAIL
J SCALE 1/2" = I'-o"
4" concrete slab with fibermesh OR
L"x6" #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fill
#5 bar cont.
Step per
o foundation plan
10"
12"
TAIL AT C
12" x 12" concrete column
block filled with concrete
and (2) #1 bars vert. teed
into lintels above
Top of footer
IC' below finished floor
(2) #5 bars cont. bottom steel
ARAGE STEPDOWN
SCALE 1/2" = 1'-0"
Verify house slab
height in Field
30"
COLUMN FOOTING DETAIL
1/2" = 1'-0"
Thicken edge to 8"x8"
with concrete and
one 45 bar continuous
GRADE
SCALE: 1/4" = 1'-0"
Termite Protection for New
Construction.
Soil treatment used for subterranean termite prevention
inside the foundation perimeter shall be done after all
excavation, backfilling and compaction is complete.
If soil area is disturbed after initial chemical soil treatment
area shall be re -treated with a chemical soil treatment
including spaces boxed or framed.
Treatment must be in accordance with the rules and laws
established bg the Florida Department of Agriculture and
consumer services.
Protective sleeves around metallic piping penetrating
concrete slab on grade floors shall not be of cellulose
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
4'1 concrete slab with Fibermesh OR
4"x4410/10 WWM on 10 mil Visqueen over
clan compacted termite treated fill
PORCH SLAB E
45 bar vert. w/
30" overlap
at each felled cell
Adjust curb height
based on gar. floor
slope.
#5 bar in curb \
L-
11-
14"
GE DETAIL
SCALE 1/2" = 1'-0"
= (TYPICAL
C IONS
4" concrete slab with fibermesh OR
Cxb'l #10/10 WWM on 10 mil Visqueen over
clean compacted termite treated fell
®I pp At'\ I
14"w x 14"d concrete monolithic
footing with (2) #5 bars cont.
Tj) GARAGE CURB( DETAIL
SCAI
/2" = 1'-0"
Filled Cell Masonry Column With One
45 From Footing To Tie Beam
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Single Filled Cell Column
NTS
Filled Cell Masonry Column With One
#5 From Footing To Beam Each.
Conc. Fill To Be 3000 PSi
See Floor Plan For Location
34'-O"
20'-0" 14'-0"
— r— —
° 00 OO i�i ���� 00 OE
° ------
J------- 4
J
Filled cell under -
girder above FI
I
E
I
O
I Rear Patio/Slab
—
I t'o be poured separate L ,
From the house slab.
I O In
IE
Thicken footingg to
I
24"w x 14"d x 24"L
a E I under filled cell PI I
EE IEI I I I I El EE under girder bearing.
Or — — — —— —i----- — — ---_J iO
Rear Patio/Slab to I
m
° I be flush with bottom of
�U
a sliding door recess.
Slope 1/2"
�_
v
I I
NIL
-a
-i
I
of I
I FI I
I IE
I
I
H.B.
E I 4" concrete slab with fibermesh OR I
6"x4" 410/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill C)l
E
I F11
-
0
�I I
I
I
-i ° IE
F-
B.
I
°
�I
E
FI
I
O
`—
° — --AAko --
ol
�r l0
o
A/C
r — — 4"0 Steel Ballard
W# I I ®felled w/ Concrete N
° owl I
F I07
#I
v
E
uVu
I m
a
4J
I IIQv I
E
r FI— — J I E�
OE I °,0= 3 I
E
E E °to
I � to
-
° Ir-
/ E lCD
°O
EL-------J ID N "ZIL I
= cO U
I LH v#= aI
iL
O X
r——F4
I n I F5 I
r Recess for _
——--— Et----
° 00 EE Garage Door 00 EO
0
t-
3 F
9'
N2" x 12" concrete column block filled
with concrete and (2) 41 bars vert. tied
into lintels above
Double Filled Cell Column
NTS
2" x 6" PT wood secured witn I Braden f�11H, i—J'-'t
3/e dia. x 6 anchor bolt at 18' o.4. Braden 6nn 5gilding UOrp.
v rl"GAl lIAA rrarL !'ur Pll I'A IIInA� Illll� A __L.i „�4 .. —nlalw lnnnG w �„v ✓ V11 \V 11 1 vvl
lvernearP door trac% secure` to wood h'
amb per manufacturer's product approval Architects — Planners
C_;aracLe Door Jamb L_)etaill
GARAGE DOOR TO WITHSTAND (PRESSURES STATED
IN PERMIT INFO BOX ON SHEET#I. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
NTS
11 S.E. Coconut Avenue
Teell (112) 281-8258 t he U r a n d C a r I t oh
Fax : (7 12) 281-8283 Spanish Lakes
E-mail: bradenaia8comcaot.net P
Stuart_ FL 34996 #AAC000032 St. Lucie County Florida
a
FILE COPY
FOOTING
SCHEDULE
Mark
size
Description
FI
14"W
x 14"D
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS
F
I2"W
X 12"D
MONOLITHIC FOOTING
WITH (2) #5 BARS CONTINUOUS
30"
x 3o" x 16"D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
F
8"W
x 8"D
THICKEN SLAB EDGE
WITH 1 #5 BAR CONTINUOUS
F5
14"W
With
x 1400
Curb at Garage
MONOLITHIC FOOTING
WITH 2 #5 BARS CONTINUOUS - CURB a 0'-0"
I A-M—A—
I- 1.1omm
� +«
.- � 6-9-I1 - Lomm 4
GARAGE Drawn by:
RIGHT C.C.U. 3 _ 12 — 2 1
Checked by:
D.R.B. OF 6
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nall Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = 1*8 x 2"
3. Minimum Sheathing Thickness I9/32" COX Plgwood
4. Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Ke
Area
Edge
Field
Fastener
Pressure
Zone 1
6"
6"
8d ring shank
45 psf
Zone 2
4"
6"
8d ring shank
16 psf
Zone 3
4"
4"
8d ring shank
84 psf
** Zone 3a
6"
6"
48 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Concrete
/ Lintel
Column
Verlfg with Plain
12"x i2"
1 Column Block
-z,#7
Rebar
Reber 148 gar Dia.
Min. Overlap
Provide 45 bars with min. 48 bar
diameters overlap into beam. Tie
Filled cell steel Into continuous
beam block steel.
Provide Cast -Crete
8118-OB/OT precast -- - -'
lintel set in mortar _
Min. 8" Bearing ---
4" Pre
Sill
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calls for it.
Buck I r<;';{ Poured Filled Cell
jamb Si:'al
Provide #5 bars with min. 48 bar
diameters overlap in filled cell. Tie
filled cell steel into continuous
tooter steel.
I Concrete Footing
J' (see tooter schedule
•-
For exact sues)
DETAIL AT WINDOW OPENING IN
CBS WALL Scale: 1/2" = I'-O"
v-
N
SINGLE PLY REAR GIRDER TRUSS
Nail 2" x 4" blocking to vert. leg of
truss with IOd x 1.5' nails at 4" o.c.
Install Simpson MGT into wall usin®®
5/8" dia. threaded rod set min. 12"
into wet beam and (22) IOd nails into truss
TRUSS BLOCKING DETAIL
t0 Lintel �ttachm&nt - ,4T iRDER STR,4PPiNG
,4T ENTER BEARiNG POINT
NTS
1/8" thick light textured stucco installed per
ASTM C 424 over ASTM D type 2 paper backed
wire lath nailed to substrate through one layer of
ASTM D Tgype 2 felt paper using 8d nails. Substrate
to be 19/32' CDX Plywood nailed at 6" o.c. in field
and edges wlth IOd ring shank nails into studs.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #I LE
26 ga. Sv crimp metal roofing attached to plywood deck using
wood screws with selr sealing washer at 12" o.c. max spacing', o
(type 2) 30 lb felt underlayment installed with min. 4' side la
laps fastened with corrosion resistant tin caps and with 1.25"
spaced 6' O.C. at all laps and two staggered rows 12" o.c, in
deck to trusses using attachment detail on this sheet
Additional Precast Lintel Lintel Bar Clear "A"B')
#5 bare
`'e'' CLEAR Length Length Span Bars Bars
2'-10" 2'-8" I'-6" 2,#3 none
i i f
3'-4" 2'-2" 2,93 none
BPS-OB/IT arS-IB/IT BF8-IS/2T
Additional 4'-O" 3'-1011 2'-8" 2,93 none
#5 bars
CLEAR ".i �: 4'-6" 4'-4" 3'-2" 2,#3 none
L.me Row of "H" :',;
4 Block Above 5'-4" 5'-2" 4'-0" 2,#3 none
r ` y Precast Lintel r 5'-8" 4'-6" Z44 none
Additional 1 6'-6" 6'-4" 5'-4" 2,#4 none
!�__--�, #5 bars �___�
1'-6" 7'-0" 6'-2" 2,45 none
8FIL-IBAT BPIL-IB/2T 8'-4" 7-10" T-O" 2,#5 none
NOTES:
I. inn. coverage of 5teel=1.5"
2. min. bearing required a ea. end=8" ALL reinforcing steel is grade 40,
3. standard for reinf, steel=ASTM A415
TYPICAL LINTEL SECTION
( PRECAST CONCRETE )
LINTEL SCHEDULE
Mark
Window
or Doo
Unit
Width
Lintel
Size
Cast -Crete
S ecificatlon
Rows of
"H" Block
Above
Bottom
steel
S'�
Top
Steel
StZs'
Max
Gravitg
Load
(PLF)
Max
Uphfi
Load
(PLF)
Max
Lateral
Load
(PLF)
L22
2'-2"
3'-P
eF8-OB/IT
1
#5
3069
1549
1024
L31
T-0
T-So
4'-O"
81128-OBAT
I
#5
256I
1343
163
L45
4'-5"
5'-10"
BPS-OB/IT
i
#5
1105
909
334
L50
5'-O"
L'-L"
SP8-OB/IT
1
#5
1238
835
121
L40
4'-8.
T-go
BPS-OB/IT
1
#5
1011
121
534
LBO
e'-On
T-4"
SFS-IB/2T
I
#5
4
#5
152
591
512
L90
9'-O"
10'-L"
SPB-IB/2T
I
#5
2
#5
443
530
401
L90B
9'-0'
10'-L"
81cIL-6/27'
ONE
1
#5
2
#5
1533
1183
401
1-I00
10'-O"
II'-4"
1 8F8-IS/2'r
I
#5
1 2
1 #5
582
494
452
LIOOB
10'-0'
II'-4"
8FIL-IB/2T
ONE
1
#5
2
#5
131.1.
1028
452
L120
12'-0"
13'-4"
BPS-IB/2T
1
#5
2
#5
411
1 426
324
L120B
IT-0"
13'-4"
8FIL-8/27'
ONE
1
#5
2
45
101S
110
324
1_140
14'-0"
15'-4"
811aIL-I15/2T
ONE
1
#5
2
#5
1250
409
259
LILO
IL'-O"
IT-4"
BPS-IB/2T
I
#5
2
#5
300
192
194
LIOOB
IL'-O"
11-4"
BFIL-IB/2T
ONE
I 1
#5
2
#5
950
Boo
194
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATIOiN. AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
hurricane anchor at each truss
with (10) IOd x 1 1/2" nails -
( 24" o.c.) supporting Max.
1810lbs. uplift
Aluminum Drip
Edge t Fascia
2" x 6" Sub-F
1.12
#9 x 1.5"
ter ASTM D
:is and 6" end
ing shank nails
field. Attach
12
4
,"— thick stucco on
attached to honzanti
2"O r
o
nails framing with nao
nIsar than ails r
horizontal wood framir
into vertical wood In
Kagcan full o vent vinyl soffit installed
using 1/8' dia shank x 15" long galv.
roofing nails with 3/8" dia. head per
product approval — eve chart sheet #1
12' x 12" concrete column
block filled with concrete
and (2) 41 bars vert. tiedT—
into lintels above
thicken edge to 8"x8"
with concrete and
one #5 bar continuous
BEYOND
Top of footer
IL" below Finished floor
a
Aluminum Drip
Edge t Fascia
Flash and Counter
flash
Nail ledger to
gable end truss
with (2) IOd is
at each web
hi —rib lath
vertical wood
s to provide
.ration into
3/4" penetration
members
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#S bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be Flush with bottom of
sliding door recess.
Step per foundation plan
Slope per foundation plan
Co crete Anchors Per
Poured Concrete
Me uracturers Specs concrete Mack wall
I/9"Mex,
N
I
Aluminum Panel
I Sizes per manufacturer
See Typical Stud Detad
x
I
I
I
' v 7/s" x 3/32" Wing Nut w/
i v appropnate washer and spacing
I ? per manurscturer's Details
o m
71o
IL v .OLe"
I s e
c o9q'
s
J
I
a m
I L
I
i
' I
I I ler5"
I
Stud Detail
Poured Concrete or "Ta
concrete block wall '\ Stud w/ Die Cast Zinc
\L Nickel Plated wing Not
Concrete Anchors PA
2.
Manuracturers Specs
Flush Mounted Shutter Detail
nt5
Brace Gable end
with 2" x 4" SYP 42
8ft back nailed to bottom
of top chords using 12) IOd
nails at each truss
PRE-ENGINEERkIED WOOD TRUSSES
8 24"o.c. TYPICAL
( shop drawings by manufacturer )
"\R-30 blown fiberglass
in bottom chord of trusses
1/2" drywall with smooth finish
Two rows of beam block filled with concrete
and (U #5 bar cont. in each row. Substitute
precast lintel filled with concrete and (U #5
bar Cont. for bottom row over openings
1/2" drywall over I" x furringg
strips at 14" o.c. with R4.1 fl-foll
insulation on typical 8" Block walls
All drywall to be installed per FBC R102.3.1
and shall meet all pertaining ASTM codes.
ID Mortar to be Type "M" only proportioned er FBC R601.1
and Mortar joints shall comply with FBC �601.2.1.
Provide Dur-O-Rock at all wet areas (ex, showers, tubs etc...)
Simpson
HETA 20
Strap
truss to
wall using Simpson
MGT with
hurricane anchor at each truss
5/8" dia.
threaded
rod with min 12"
embedment
( 24" o.c.)
supporting Max.nto
pp g aX.
(22)
beam either
IOd nails
wet set or in
into truss, Add
epoxy with
blockingto
1810
lbs. uplift ETA 20
truss
leg per detail on
this sheet
•
N
L90
L90
LLO
BI
BI
0
L90 BI
N
>
BI
J
Y
LLO
W
L
I
12
L g i I— L I W ..
— _
2„
U I
I I— U BI
W=3
I I
I WEE
S OPE _ toZI
�t I
U
i W77
W oa up
z
�
I Q
W
W
p
I
I U)
;L
I
BI L31
B
I
�
w
-nn -
n
f
eW
N
_ __
___ --
_—
N
Gulf Coast Supplu. and MFG 5
Crim Metal roorin FL 411651.12
woog screws with self sealing w
Sher at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayme
t installed with min. 4' side laps and 6" end
la s fastened with corrosion re
scant tin caps and with 1.25" rin shank nails
eck to trusses using attachma
t detai on this sheet
BI
#IC
G
u
Q 1
I unth fight
L SLOPE 4
BI I I I U up
I ( P
ted
T
I
a'-O" MAX.
I
witha
I ( T S.
S
back
of top chc
I I
T1
I
^ I
r
I
Z
2
_
I L
I ...
1
p I
oL
i I
i
I I BI L317
BI I BI I
I
I
O
BI L45
N
=
BiLSO
on
hurrica anc
HET
r a
2
eac
trus
JL&O
BI
~ in
c.)
uppo
ting
ax.1810
bs. u
lift
BI
m
L9B0B
(EiETA 20
Brace Gable end
4" SYP #2 min.
nailed to bottom
rds using (2) IOd
ails at each truss
I
FIII cell with concrete and
#5 vent. (typicaU.
O C
F F
L-4(I)
Max. sppbar
exceed
Wood
48" unlessnotherrlwiseo noted
see foundation plan notes for
— OVERHANGS
AT 1'-0" UNLESS OTHERWISE
NOTED ON THiS SHEET
Base
spacing at openings
4" concrete slab with fibermesh
— ROOF
PITCH
AT -4:12 UNLESS OTHERWISE
NOTED ON THIS SHEET
6"x6" #10/10 WWM on 6 mil en
mil ViVlsqueen over
- TRUSS
SHOP
DRAWINGS TO BE PROVIDED BY MANUFACTURER
clean compacted termite treated fill
- ANY CHANGES TO THIS PLAN SHALL BE
SUBMITTED TO THE
1 m
=1 I IIIIIIIII1 IIII I1 IIIII1 IIII IIII I-
11111 IIII-IIII ; , :s��n1111��11111„.IIII till-till=till 11111 li��- "FI
II„IIII111111 1�i1_�i Tublcal Section at Front
ARCHITECT FOR APPROVAL iN WRITING PRIOR TO STARTING CONSTRUCTION.
— ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
— ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
F OrCi1 — CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
>" = I'—o" FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
PANEL
"A"
arc# Description Wire Load BR Pales
2 AHU #10 3.5 kw 30 2
4
Poles
BR
Load
Wire
Description
arc#
2
40
1.0 kw
#8
A/C camp
1
3
2
30
4.5 kw
#lo
40 gal. water HTR
5
Ran ®
#G
12.0 kw
5o
2
1
8
�-
I
20
1 1.8 kw
tt12
Pump
9
10
Dr er
#10
5.0 kw
30
2
11
12
1
20
1.5 kw
#12
13
14
Dishwasher
412
1.2 kw
20
1
1
20
1.5 kw
#12
Microwave
15
16
Refrigerator
#12
1.2 kw
20
1
I
20
1.5 kw
#12
Kitchen S.A.C.
11
18
Recepts
412
20
1
I
20
LS kw
#12
Kitchen B.A.C.
19
20
Recepts
#12
20
1
I
20
1 1.2 kw
#12
Clothes Washer
21
22
Recepts
#12
20
1
1
20
0.81 kw
#12
Garage Door Opener
23
24
Recepts
#12
-
20
1
1
20
1.4 kw
#12
25
24
Recepts
#12
-
20
1
1
20
1.92 kw
#12
2-1
28
Recepts
#12
-
20
1
1
20
#12
General Lighting
29
30
Recepts
Recepts
Exterior GFCI
#12
20
1
I
20
#12
General Lighting
31
32
#12
20
I
I
20
#12
General Lighting
33
34
#12
20
1
1
20
#12
General Lighting
35
3(.
Bathroom GFI
#12
20
1
I
120
#12
smoke Detectors
31
38
General Lighting
#12
20
1
I
20
#12
Bathroom GPI
39
40
General Lighting
#12
20
1
spare
41
42
spare
PANEL "A" LOAD CALCULATION SHEET
Load Description Qt .
Watts
Total(Watts)
General Lighting l3, .watts
Small_ A.gpliance, Crcuit(s)..
Range
Refrigerator ...
Microwave
Dish Washer .............. ................................
............
Clothes ,Washer..... _ ..
Clothes ,Dryer. _ .... _ ,
Water Heater
Water, .Pump ................................................
.Garage Door,Opener.
sq.. ft.)
_ . . . ........ ..
_ .... . _ .
. ..
...
1135
3
5,205
2
1,500
3.000
1
12,000
12,000
1
1,200
1.200
1
1,500
1.500
1
4200
1,200
1
1,200
1,200
1
5,000
5,000
1
4.500
4,500
1
1,800
1,800
1
810
810
First 10000 Watts
Remainder
Electric Heat or A/C
e100%
21,415 040%
10,000 945%
Total
1
1
1
Watts
10,000
0
10,000
31415
10,000
10,944
10,000
Calculated Load
Calculated Wattage Divided bg voltage = Total
Watts
Voltage
Amps
fsanel Size Required =
30,966
240
129.03
150 Ampsl
Electrical S mbol Legend
S
Single Pole Switch
®
Recessed Can Light
S3
Double Pole Switch
®
Eyeball Recessed
L
Pe
Push Button Switch
Exhaust Fan
Duplex Outlet
Ceiling Mounted Light
Special Receptacle
o-
Wall Mounted Light
=E)
Grc
Waterproof ground fault circuitJ.P.
interrupter
Light with Pull Chain (attic)
®
Floor Duplex Outlet
©
Computer Connection Jack
Fc-ml
Carbon Monoxide Detector
'�&
Flood Light
TQ
Thermostat
m
Electrical Panel
©
Central Vac
Electrical Meter
®
Smoke Detector
Ceiling fan
©
Television Jack
FYI
Telephone Jack
AC
A/C Disconnect
®
I x 4 Florescent Light
®
2 x 4 Florescent Light
SPKR
Speaker Hook -Up
0
Intercom
H.B.
Vent thru___
-offit
PATIO/SLAB
I
I
CAR AT
Rg0M
I
I
CM
169 C MCenter Reglsters
IOxI xl on ceiling fan I 160xlOxl
DINING
ROOM
~ 18 x4 I
I
Y2oxoWI ¢ I
T
I
I
14' I
I
232 CFM '
12 4x1 '
I
LJ6- _
SECOND
BEDROOM
1
12xl2x8 i lFF
B/A �-
12"
91
163 CFM
IOxIoxL
MASTER
BEDROOM
163 CFM
IOxIOxb
B/A
s r - - - �12x12x9
LOSET B/A
8 CF
i I 1
°
° I 10"
Attic Accom
with light
COVERED
PORCH
= JUNCTION BOX TO SUPPORT A FAN � N I C � L L � Y C u T
O = THERMOSTAT LOCATION
B/A = BALANCED AIR SCALE: I/+' = P-0"
Electric Notes:
I. Use copper wire onlyg, no aluminum. I1. It Is not the Intent of these plans o show every minor detail
2. Provide and were all required smoke detectors. of construction. The contractor shall furnish and install
3. Contractor to verify location of electrical all items for a complete electrical system and provide all
service and provider. the requirements necessary for the quipment to be placed in
4. ALL paddle fans shall be on a rheostat. proper working order.
S. ALL bath and kitchen receptacles to be GFI protected. 18, All work shall be done in accordant with the N.E.C. and
6. ALL exterior outlets to be WP/GFI protected. shall comply with all local codes and ordinances, and shall
8. AFCI receptacleess are required In all rooms except . Recessed cans be installed per NFPA requirements. meet all standard requirements of the local electric utility
and telephone company.
Kitchen, Bathrooms, and Garage.
9. A/C Return Air Balance Must comply w/ FBC RMI402 Iq, The electrical system shall be completely and effectivel
P
sleeved In PVC y
10. A/C RefrigVC lines that are run thru slabs must be grounded as re the latest edition of the N.E.C.
required b y
11. ALL A/C Equipment shall comply with energy calculation 20. All material shall be new and shall bear underwriters'
12. All work shall be performed by a licensed electrical labels where applicable.
contractor, the completed system shall be fully operative.
13. Contractor shall pay for all fees, permits, testing, and 21. All equipment and panel sizes shall be verified before
inspections including blower testing where required ordering. The contractor shall provide circuit routings to
A. All work shall be coordinated with other trades to avoid suit the job conditions.
interference with the progress of construction.
15. All required insurance shall be provided for protection 22. Furnish and install all fixtures as called for on the plans
against the public liability and property damage for the or as selected by others.
duration of the work.
16. Contractor shall guarantee all materials and workmanship 23. All raceways and pipes placed In o through any concrete
free of defects for a period of not less than two years from slab shall be spaced a minimum of three diameters of the
the date of acceptance or certificate of occupancy, or one largest conduit or pipe from any other service.
year from closing sale of house.
Correction of defects shall be completed (without additional 24. All exposed wire below 9'-1" shall a installed in metal EMT
charge and shall include replacements or repair of any conduit.
other phase of installation that may have been damaged. 25. Dryer Vents to be installed per ABC RM1502
■
PATIO/SLAB
- - - - - _ \
/IGovered Porch `\
541
�
MASTER
if BEDROOM
I �
1
LIP GFCI /
V
v v /
I ,
I /
GrtR IAT
Smoke / Carbon - - -
RO M Monoxide Detector
Combo
I \
I S 0
M
I
I _
I -
I �-
I II 0 I I
II LQSET
N II I
Vent-thru I I I
Soffit I
DINING I I GFCI
ROOM I F---p
I
G CI IGFCI GFCI
° °
I
\� I KITCHENISS
1
- smQka / CXbet2 - J
Monoxide Detector
CI Hines n / Combo
3'-2" 3'-2" 24" \
H.B.
A/C 5o M
#I Exhaust Duct F
Thru Soffit \ Fcl
150 Amp I I k1'1eter
Panel
GARAGE
r-----------------
I I
I I
I I
I I
I I
I I
I I
I 1
I I
I I
I I
I I
A/C disc.
SO
iK2/O Aluminum feed AMP
MCB
I `/2' Conduit � PANEL
M TE
AHU
2" PVC ( FPL
2" rigid service FPL Iar:e 1cont ppe�aw, a slab
ELECTRICAL RISER
- Contractor shall use AL-CU Landing lugs. NTS
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
Braden it
Braden AIA, FA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: (112) 281-8258
Fax
: (112) 281-8283
E-mail:
bradenaia8comcast.net
Stuart. FL
34994 #AAC000032___
-I�------ �-- Aq6,
�w----
enter >22" x 54"Attic Access
usth light
S�COND
BEDROODA , lyo A
/ y S
a i\
I / \
Wire For
Front Post
Light WP GFCI \
4\- \
\ tQVERED
P OTC F1 � F-1
u
Optional mp
panel location l / Panel
Pull chain /
light in attic /
42"h GFCI
GARAGE
Garage
Door
Opener
r----------------- i
I I
I I
I I
I I
I I
I I
I I
I I
I 1
I 1
I I
I I
ELEC7�IC/4L PL/4N
Post Light with
I Photo cell
Wynne Building Corp.
The Grand Carlton
Spanish Lakes
St. Lucie County Florida
Exhaust Duct
Thru Soffit
4" Exhaust
Duct Thru
Wall
WP GFCI
Install oulet
N "\under disc.
o) not shown for
clarity
A/C #I
eter
SCALE: 1/4" = 1'-0"
Attic Venting Calculations FBC 2309.1
Total Attic Space = 2124 sq. ft.
Venting Ratio 1/150 = 14.16 sq. ft. required
Provide A Continuous Vented Soffit
MODEL:
Date Drawn
5-9-11
GARAGE
Drawn raven by:
RIGHT
C.C.U.
Checked by:
D.R.B.
Revisions
Sheet Comm #
E 1 12-27
OF 5