HomeMy WebLinkAboutSOIL NUCLEAR GAUGESoil Nuclear Gauge
Client:
Project: I -7
Report Date: 7/20/2018
Standard Pacific Homes, South Florida
13-0183.00
''eRNAslo`'Pv
Test Method: ASTM D 6938
825 Coral Ridge Drive
Riverbend
Port St Lucie
Coral Springs, FL 33071-4180
St. Lucie County, Florida
FBPE CA # 4930
607 NW Commodity Cove
Port St. Lucie, FL 34986
Phone: 772-924-3575 1 Fax: 772-924-3580
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
-Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
(%)
Remark
138
7/18/18
P-2
N/A
13.0
106.0
10.4
104.1
12
98
95 / 105
Pass
139
7/18/18
P-2
N/A
13.0
106.0 _
10.0
105.9
12
100
95 / 105
Pass
140
7/18H 8
P-2
N/A
13.0
106.0
10.2
106.3
1 12
1 100
95 / 105
Pass
Test
Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
138
Below Slab Grade: Foundation pad lot 5, northwest section
0-1
Troxler / T3430 / 22260 /
Monreal, Nathan
139
Below Slab Grade: Foundation pad lot 5, center section
0-1
Troxler / T3430 / 22260 /
Monreal, Nathan
140
Below Slab Grade: Foundation pad lot 5, southeast section
0-1
Troxler / T3430 / 22260 /
Monreal, Nathan
-
Remarks
Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
��IIIIIIII/�
0 632 =
P.E.
f % S2TATG f1F .'•Ll��
State`/��''Flg �� •`�•
IIII W
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
I.e 0
C
CD 03 Z
0 li rd
lli
Page 1 of 1